We present minimum 20 year results of a randomized, prospective double blinded trial (RCT) of cross-linked versus conventional polyethylene (PE), using a computer assisted method of PE wear measurement. After Ethics Committee approval, 122 patients were enrolled into an RCT comparing Enduron (non cross-linked PE) and highly cross-linked Marathon PE (DePuy, Leeds, UK). Other than the PE liners, identical components were used, a Duraloc 300 metal shell with one screw, a 28mm CoCr femoral head and a cemented Charnley Elite femoral stem. All patients were followed with anteroposterior (A∼P) and lateral radiographs at 3 days, 6 weeks, 3 months, 6 months, 1, 2, 3, 4, 5, 10 and 20 years. PE wear was measured with PolyMig, which has a phantom validated accuracy of ± 0.09mm. At minimum 20 year follow-up, 47 patients had died, 5 of which had been revised prior to their death. Another 32 patients were revised and alive, leaving 43 patients unrevised and alive (15 Enduron, 28 Marathon). No patients were lost to follow-up, but 2 were not able to be radiographed (dementia), leaving 41 patients (15 Enduron, 26 Marathon) available for PE wear measurement. After the bedding-in period, Enduron liners had a wear rate of 0.182 mm/year, and Marathon liners had a wear rate of 0.028 mm/year. At 20 years follow-up, 37 patients had required revision. Patients with conventional PE had three times the revision rate (28/37) of those who received XLPE (9/37). This is the longest term RCT showing substantially improved clinical and radiological results when XLPE is used as the bearing surface.
A randomized trial was designed to compare the outcome of ceramic-on-ceramic with ceramic on conventional polyethylene. These patients have been followed for 15 years. 58 hips in 57 patients under 60 years of age were randomized into one of two groups. Patients were blinded to the type of hip they received. Both groups of patients were treated routinely with prophylactic peri-operative antibiotics and low molecular weight Heparin. All patients were seen at six weeks, three months and annually after surgery. Clinical and radiologic assessment was carried out at each visit. Fifty-eight hips were available for analysis, 28 in the CoP group and 29 patients in the CoC group. Mean age of both groups was less than 45 years. There were seven revisions (16%) among the 58 patients enrolled in the study. In the CoP group four patients underwent revision with head and liner exchange for eccentric polyethylene wear 16 years post-implantation. In the CoC group one patient had a cup revision at 15 years for acute aseptic instability of the acetabulum; two additional patients in the CoC group had femoral head exchange, one for fracture and one for trunnion corrosion. Both occurred 14 years after the index surgery. Functional outcome scores showed no difference between the two groups at 15 years. Radiographically there was a statistically difference in wear between the two groups. This study demonstrates that both ceramic-on-ceramic and ceramic-on-polyethylene produce satisfactory functional results with low revision rates in young patients.
Aims. Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR). Methods. In this
Introduction. The purpose of this study was to evaluate the long term changes in bone mineral density (BMD) following implantation of a low-modulus composite femoral component designed to closely match the stiffness of the proximal femur and minimize stress shielding. Specifically, we asked: 1) How does BMD in the proximal femur change with time and with Gruen zone location; 2) Does BMD in the proximal femur stabilize after two years of implantation?. Methods. We retrospectively reviewed a subgroup of sixteen patients who had preoperative and postoperative DEXA scans in an FDA multi-center
Introduction. Patient related outcome measures (PROMS) are now routinely undertaken in patients undergoing hip arthroplasty. These are in the form of the Oxford Hip Score (OHS) and EQ5D questionnaires pre-operation and at 6 months' post operation. MYMOPS is a patient specific outcome measure that allows patients to list their individualised symptoms and activities that are limited and is used is other medical specialities but not currently within orthopaedic surgery. The aim of this study was to validate the MYMOPS questionnaire for use in hip arthroplasty by comparing it to the OHS. Patients/Materials & Methods. At a single centre, 50 patients were recruited to our
Aims. To compare the in vivo long-term fixation achieved by two acetabular components with different porous ingrowth surfaces using radiostereometric analysis (RSA). Methods. This was a minimum ten-year follow-up of a
Hip arthroscopy (HA) has become the treatment of choice for femoroacetabular impingement (FAI). However, less favourable outcomes following arthroscopic surgery are expected in patients with severe chondral lesions. The aim of this study was to assess the outcomes of HA in patients with FAI and associated chondral lesions, classified according to the Outerbridge system. A systematic search was performed on four databases. Studies which involved HA as the primary management of FAI and reported on chondral lesions as classified according to the Outerbridge classification were included. The study was registered on PROSPERO. Demographic data, patient-reported outcome measures (PROMs), complications, and rates of conversion to total hip arthroplasty (THA) were collected.Aims
Methods
Outcomes following different types of surgical intervention for femoroacetabular impingement (FAI) are well reported individually but comparative data are deficient. The purpose of this study was to conduct a systematic review (SR) and meta-analysis to analyze the outcomes following surgical management of FAI by hip arthroscopy (HA), anterior mini open approach (AMO), and surgical hip dislocation (SHD). This SR was registered with PROSPERO. An electronic database search of PubMed, Medline, and EMBASE for English and German language articles over the last 20 years was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We specifically analyzed and compared changes in patient-reported outcome measures (PROMs), α-angle, rate of complications, rate of revision, and conversion to total hip arthroplasty (THA). A total of 48 articles were included for final analysis with a total of 4,384 hips in 4,094 patients. All subgroups showed a significant correction in mean α angle postoperatively with a mean change of 28.8° (95% confidence interval (CI) 21 to 36.5; p < 0.01) after AMO, 21.1° (95% CI 15.1 to 27; p < 0.01) after SHD, and 20.5° (95% CI 16.1 to 24.8; p < 0.01) after HA. The AMO group showed a significantly higher increase in PROMs (3.7; 95% CI 3.2 to 4.2; p < 0.01) versus arthroscopy (2.5; 95% CI 2.3 to 2.8; p < 0.01) and SHD (2.4; 95% CI 1.5 to 3.3; p < 0.01). However, the rate of complications following AMO was significantly higher than HA and SHD. All three surgical approaches offered significant improvements in PROMs and radiological correction of cam deformities. All three groups showed similar rates of revision procedures but SHD had the highest rate of conversion to a THA. Revision rates were similar for all three revision procedures.
Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and anatomical loading. A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. This single cohort was then retrospectively compared with previously reported randomized cohorts of cemented monoblock (cemented) and trabecular metal (trabecular) acetabular implants. The primary outcome measure was periprosthetic bone density using dual-energy x-ray absorptiometry over two years. Secondary outcomes included radiological and clinical analysis.Aims
Methods
It has been suggested that the direct anterior approach (DAA) should be used for total hip arthroplasty (THA) instead of the posterior approach (PA) for better early functional outcomes. We conducted a value-based analysis of the functional outcome and associated perioperative costs, to determine which surgical approach gives the better short-term outcomes and lower costs. This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) protocol and the Cochrane Handbook. Several online databases were searched. Non-stratified and stratified meta-analyses were conducted to test the confounding biases in the studies which were included. The mean cost and probability were used to determine the added costs of perioperative services.Aims
Methods
Aims. Using a systematic review, we investigated whether there is an
increased risk of post-operative infection in patients who have
received an intra-articular corticosteroid injection to the hip
for osteoarthritis prior to total hip arthroplasty (THA). Methods. Studies dealing with an intra-articular corticosteroid injection
to the hip and infection following subsequent THA were identified
from databases for the period between 1990 to 2013. Retrieved articles
were independently assessed for their methodological quality. Results. A total of nine studies met the inclusion criteria. Two recommended
against a steroid injection prior to THA and seven found no risk
with an injection. No
Although periarticular injection plays an important role in multimodal pain management following total hip arthroplasty (THA), there is no consensus on the optimal composition of the injection. In particular, it is not clear whether the addition of a corticosteroid improves the pain relief achieved nor whether it is associated with more complications than are observed without corticosteroid. The aim of this study was to quantify the safety and effectiveness of cortocosteroid use in periarticular injection during THA. We conducted a prospective, two-arm, parallel-group, randomized controlled trial involving patients scheduled for unilateral THA. A total of 187 patients were randomly assigned to receive periarticular injection containing either a corticosteroid (CS group) or without corticosteroid (no-CS group). Other perioperative interventions were identical for all patients. The primary outcome was postoperative pain at rest during the initial 24 hours after surgery. Pain score was recorded every three hours until 24 hours using a 100 mm visual analogue scale (VAS). The primary outcome was assessed based on the area under the curve (AUC).Aims
Methods
Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure.Aims
Methods
We studied the safety and efficacy of multimodal thromboprophylaxis in patients with a history of venous thromboembolism (VTE) who undergo total hip arthroplasty (THA) within the first 120 postoperative days, and the mortality during the first year. Multimodal prophylaxis includes discontinuation of procoagulant medications, VTE risk stratification, regional anaesthesia, an intravenous bolus of unfractionated heparin prior to femoral preparation, rapid mobilization, the use of pneumatic compression devices, and chemoprophylaxis tailored to the patient’s risk of VTE. Between 2004 to 2018, 257 patients with a proven history of VTE underwent 277 primary elective THA procedures by two surgeons at a single institution. The patients had a history of deep vein thrombosis (DVT) (186, 67%), pulmonary embolism (PE) (43, 15.5%), or both (48, 17.5%). Chemoprophylaxis included aspirin (38 patients), anticoagulation (215 patients), or a combination of aspirin and anticoagulation (24 patients). A total of 50 patients (18%) had a vena cava filter in situ at the time of surgery. Patients were followed for 120 days to record complications, and for one year to record mortality.Aims
Methods
The aim of this randomized trial was to compare the functional outcome of two different surgical approaches to the hip in patients with a femoral neck fracture treated with a hemiarthroplasty. A total of 150 patients who were treated between February 2014 and July 2017 were included. Patients were allocated to undergo hemiarthroplasty using either an anterolateral or a direct lateral approach, and were followed for 12 months. The mean age of the patients was 81 years (69 to 90), and 109 were women (73%). Functional outcome measures, assessed by a physiotherapist blinded to allocation, and patient-reported outcome measures (PROMs) were collected postoperatively at three and 12 months.Aims
Patients and Methods
The custom triflange is a patient-specific implant
for the treatment of severe bone loss in revision total hip arthroplasty
(THA). Through a process of three-dimensional modelling and prototyping,
a hydroxyapatite-coated component is created for acetabular reconstruction.
There are seven level IV studies describing the clinical results
of triflange components. The most common complications include dislocation
and infection, although the rates of implant removal are low. Clinical
results are promising given the challenging problem. We describe
the design, manufacture and implantation process and review the
clinical results, contrasting them to other methods of acetabular
reconstruction in revision THA. Cite this article:
Tranexamic acid (TXA) has been used to reduce
blood loss during total hip arthroplasty (THA), but its use could increase
the risk of venous thromboembolic disease (VTE). Several studies
have reported that TXA does not increase the prevalence of deep
vein thrombosis (DVT), but most of those used routine chemical thromboprophylaxis,
thereby masking the potential increased risk of TXA on VTE. We wished
to ascertain whether TXA increases the prevalence of VTE in patients
undergoing THA without routine chemical thromboprophylaxis. We carried
out a retrospective case-control study in 254 patients who underwent
a primary THA, 127 of whom received TXA (1 g given pre-operatively)
and a control group of 127 who did not. All patients had mechanical
but no chemical thomboprophylaxis. Each patient was examined for
DVT by bilateral ultrasonography pre-operatively and on post-operative
days 1 and 7. TXA was found to statistically significantly increase
the incidence of total DVT on post-operative day 7 compared with
the control group (24 (18.9%) and 12 (9.4%), respectively; p <
0.05) but most cases of DVT were isolated distal DVT, with the exception
of one patient with proximal DVT in each group. One patient in the control
group developed a non-fatal symptomatic pulmonary embolism (PE).
The use of TXA did not appear to affect the prevalence of either
proximal DVT or PE. Cite this article:
Patient safety is a critical issue in elective
total joint replacement surgery. Identifying risk factors that might
predict complications and intensive care unit (ICU) admission proves instrumental
in reducing morbidity and mortality. The institution’s experience
with risk stratification and pre-operative ICU triage has resulted
in a reduction in unplanned ICU admissions and post-operative complications
after total hip replacement. The application of the prediction tools
to total knee replacement has proven less robust so far. This work
also reviews areas for future research in patient safety and cost
containment. Cite this article:
We performed a case–control study to compare
the rates of further surgery, revision and complications, operating time
and survival in patients who were treated with either an uncemented
hydroxyapatite-coated Corail bipolar femoral stem or a cemented
Exeter stem for a displaced intracapsular fracture of the hip. The
mean age of the patients in the uncemented group was 82.5 years
(53 to 97) and in the cemented group was 82.7 years (51 to 99) We used
propensity score matching, adjusting for age, gender and the presence
or absence of dementia and comorbidities, to produce a matched cohort
receiving an Exeter stem (n = 69) with which to compare the outcome of
patients receiving a Corail stem (n = 69). The Corail had a significantly
lower all-cause rate of further surgery (p = 0.016; odds ratio (OR)
0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further
surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating
time was significantly less for the Corail group than for the cemented Exeter
group (59 min [12 to 136] Cite this article:
Direct anterior approaches to the hip have gained
popularity as a minimally invasive method when performing primary
total hip replacement (THR). A retrospective review of a single
institution joint registry was performed in order to compare patient
outcomes after THR using the Anterior Supine Intermuscular (ASI)
approach Cite this article