Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 18 - 18
1 Mar 2014
Al-hadithy N Furness N Patel R Crockett M Anduvan A Jobbaggy A Woods D
Full Access

Cementless surface replacement arthroplasty (CSRA) is an established treatment for glenohumeral osteoarthritis. Few studies however, evaluate its role in cuff tear arthopathy. The purpose of this study is to compare the outcomes of CSRA for both glenohumeral osteoarthritis and cuff tear arthopathy.

42 CSRA with the Mark IV Copeland prosthesis were performed for glenohumeral osteoarthritis (n=21) or cuff tear arthopathy (n=21). Patients were assessed with Oxford and Constant scores, patient satisfaction, range of motion and radiologically with plain radiographs.

Mean follow-up and age was 5.2 years and 74 years in both groups. Functional outcomes were significantly higher in OA compared with CTA with OSS improving from 18 to 37.5 and 15 to 26 in both groups respectively. Forward flexion improved from 60° to 126° and 42° to 74° in both groups. Three patients in the CTA group had a deficient subscapularis tendon, two of whom dislocated anteriorly.

Humeral head resurfacing arthroplasty is a viable treatment option for glenohumeral osteoarthritis. In patients with CTA, functional gains are limited. We suggest CSRA should be considered in low demand patients where pain is the primary problem. Caution should be taken in patients with a deficient subscapularis due to the high risk of dislocation.


Reverse Total shoulder arthroplasty (RTSA) was initially introduced to treat rotator cuff arthropathy. With proven successful long-term outcomes, it has gained a noteworthy surge in popularity with its indications consequently being extended to treating various traumatic glenohumeral diseases. Several countries holding national registries remain a guide to the use the prosthesis, however a notable lack of epidemiological data still exists. More so in South Africa where the spectrum of joint disease related to communicable diseases such as HIV and tuberculosis may influence indications and patient demographics. By analysing the epidemiology of patients who underwent RTSA at our institution, we aimed to outline the local disease spectrum, the patients afflicted and indications for surgery. A retrospective review of all patients operated within the sports unit between 1 January 2019 and 31 December 2022 was conducted. An analysis of the epidemiological data pertaining to patient demographics, diagnosis, indications for surgery and complications were recorded. Included in the review were 58 patients who underwent primary RTSA over the 4-year period. There were 41 females and 17 male patients, age <55 years (n= 14) >55 years (n=44). The indications included 23 rotator cuff arthropathy (40%), 12 primary glenohumeral osteoarthritis (OA) (20%), 10 avascular necrosis (AVN) humeral head (17%), 7 inflammatory OA (12%), 4 chronic shoulder dislocation (7%) and 2 sequalae of proximal humerus fractures (4%). The study revealed RTSA being performed in patients older than 55 years of age, the main pathologies included rotator cuff arthropathy and primary OA, however AVN and shoulder dislocations secondary to trauma contributed significantly to the total tally of surgeries undertaken. This highlights the disease burden of developing countries contributing to patients presenting for RTSA


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 10 - 10
1 May 2019
Iannotti J
Full Access

Introduction. The degree of glenoid bone loss associated with primary glenohumeral osteoarthritis can influence the type of glenoid implant selected and its placement in total shoulder arthroplasty (TSA). The literature has demonstrated inaccurate glenoid component placement when using standard instruments and two-dimensional (2D) imaging without templating, particularly as the degree of glenoid deformity or bone loss worsens. Published results have demonstrated improved accuracy of implant placement when using three-dimensional (3D) computed tomography (CT) imaging with implant templating and patient specific instrumentation (PSI). Accurate placement of the glenoid component in TSA is expected to decrease component malposition and better correct pathologic deformity in order to decrease the risk of component loosening and failure over time. Different types of PSI have been described. Some PSI use 3D printed single use disposable instrumentation, while others use adjustable and reusable-patient specific instrumentation (R-PSI). However, no studies have directly compared the accuracy of different types of PSI in shoulder arthroplasty. We combined our clinical experience and compare the accuracy of glenoid implant placement with five different types of instrumentation when using 3D CT imaging, preoperative planning and implant templating in a series of 173 patients undergoing primary TSA. Our hypothesis was that all PSI technologies would demonstrate equivalent accuracy of implant placement and that PSI would show the most benefit with more severe glenoid deformity. Discussion and Conclusions. We demonstrated no consistent differences in accuracy of 3D CT preoperative planning and templating with any type of PSI used. In Groups 1 and 2, standard instrumentation was used in a patient specific manner defined by the software and in Groups 3, 4, and 5 a patient specific instrument was used. In all groups, the two surgeons were very experienced with use of the 3D CT preoperative planning and templating software and all of the instrumentation prior to starting this study, as well as very experienced with shoulder arthroplasty. This is a strength of the study when defining the efficacy of the technology, but limits the generalizability of the findings when considering the effectiveness of the technology with surgeons that may not have as much experience with shoulder arthroplasty and/or the PSI technology. Conversely, it could be postulated that greater improvements in accuracy may be seen with the studied PSI technology, when compared to no 3D planning or PSI, with less experienced surgeons. There could also be differences between the PSI technologies when used by less experienced surgeons, either across all cases or based upon the severity of pathology. When the surgeon is part of the method, the effectiveness of the technology is equally dependent upon the surgeon using the technology. A broader study using different surgeons is required to test the effectiveness of this technology. Comparing the results of this study with published results in the literature, 3D CT imaging and implant templating with use of PSI results in more accurate placement of the glenoid implant when compared to 2D CT imaging without templating and use of standard instrumentation. In previous studies, this was most evident in patients with more severe bone deformity. We believe that 3D CT planning and templating provides the most value in defining the glenoid pathology, as well as in the selection of the optimal implant and its placement. However, it should be the judgment of the surgeon, based upon their experience, to select the instrumentation to best achieve the desired result


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 319 - 319
1 Dec 2013
Galasso O Gasparini G Castricini R Mastroianni V
Full Access

BACKGROUND:. Few studies have evaluated at a medium-term follow-up the use of semiconstrained reverse shoulder arthroplasty (RSA) for primary glenohumeral osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy excluding any other shoulder disease. Moreover, data on patients' quality of life after this surgery are lacking. METHODS:. In this prospective cohort study, 80 patients were evaluated after an RSA for either primary osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy with the Constant-Murley score (CMS), ROM, and Short Form Health Survey (SF-36). A radiologic assessment was performed pre- and postoperatively. RESULTS:. At a mean 5-year follow-up, the cumulative survival rate was 97.3% and significant improvements in the CMS and ROM were observed when compared with the baseline values. The CMS was 93.2% of the sex- and age-matched normal values. The postoperative SF-36 scores showed no significant differences compared with normative data. Younger patients and subjects with worse preoperative conditions achieved the greatest benefit after RSA. A 70% scapular notching rate was noted and the length of follow-up was found to be associated with the severity of scapular notching. CONCLUSIONS:. This study introduces new predictors for surgical outcomes, and it shows that patients who had undergone RSA a mean of 5 years earlier exhibit similar functionality and health-related quality of life with respect to healthy controls