Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 51 - 51
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Outcomes for guided motion primary total knee arthroplasty (TKA) in obese patients are unknown. 1,684 consecutive patients underwent 2,059 primary TKAs with a second-generation guided motion implant between 2011–2017 at three European and seven US sites. Of 2,003 (97.3%) TKAs in 1,644 patients with BMI data: average age 64.5 years; 58.4% females; average BMI 32.5 kg/m2; 13.4% had BMI ≥ 40 kg/m2. Subjects with BMI ≥ 40 kg/m2 had longest length of hospital stay (LOS) at European sites; LOS similar at US sites. Subjects with BMI ≥ 40 kg/m2 (P=0.0349) had longest surgery duration. BMI ≥ 40 kg/m2 had more re-hospitalizations or post-TKA reoperations than BMI < 40 kg/m2 (12.7% and 9.2% at five-year post-TKA, P<0.0495). Surgery duration and long-term complication rates are higher in patients with BMI ≥ 40 kg/m2, but device revision risk is not elevated


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 13 - 13
1 Apr 2012
Al-Janabi Z Basanagoudar P Nunag P Springer T Deakin AH Sarungi M
Full Access

The routine use of a fixed distal femoral resection angle in total knee arthroplasty (TKA) assumes little or no variation in the angle between the anatomical and mechanical femoral axes (FMA angle) in different patients. The aims of this study were threefold, firstly to investigate the distribution of FMA angle in TKA patients, secondly to identify any correlation between the FMA angle and the pre-operative coronal mechanical femoro-tibial (MFT) angle and in addition to assess post-operative MFT angle with fixed or variable distal femoral resection angles. 277 primary TKAs were performed using either fixed or variable distal femoral resection angles (174 and 103 TKAs respectively), with intramedullary femoral and extramedullary tibial jigs. The variable distal femoral resection angles were equal to the FMA angle measured on pre-operative Hip-Knee-Ankle (HKA) digital radiographs for each patient. Outcomes were assessed by measuring the FMA angle and the pre- and post-operative MFT angles on HKA radiographs. The FMA angle ranged from 2° to 9° (mean 5.9°). Both cohorts showed a correlation between FMA and pre-operative MFT angles (fixed: r = -0.499, variable: r = -0.346) with valgus knees having lower FMA angles. Post-operative coronal alignment within ±5° increased from 86% in the fixed angle group to 96% when using a variable angle, p = 0.025. For post-operative limb alignment within ±3°, accuracy improved from 67% (fixed) to 85% (variable), p = 0.002. These results show that the use of a fixed distal femoral resection angle is a source of error regarding post-operative coronal limb malalignment. The correlation between the FMA angle and pre-operative varus-valgus alignment supports the rational of recommending the adjustment of the resection angle according to the pre-operative deformity (3°-5° for valgus, 6°-8° for varus) in cases where HKA radiographs are not available for pre-operative planning


Bone & Joint 360
Vol. 9, Issue 2 | Pages 46 - 48
1 Apr 2020
Evans JT Whitehouse MR


Bone & Joint Research
Vol. 7, Issue 1 | Pages 12 - 19
1 Jan 2018
Janz V Schoon J Morgenstern C Preininger B Reinke S Duda G Breitbach A Perka CF Geissler S

Objectives

The objective of this study was to develop a test for the rapid (within 25 minutes) intraoperative detection of bacteria from synovial fluid to diagnose periprosthetic joint infection (PJI).

Methods

The 16s rDNA test combines a polymerase chain reaction (PCR) for amplification of 16s rDNA with a lateral flow immunoassay in one fully automated system. The synovial fluid of 77 patients undergoing joint aspiration or primary or revision total hip or knee surgery was prospectively collected. The cohort was divided into a proof-of-principle cohort (n = 17) and a validation cohort (n = 60). Using the proof-of-principle cohort, an optimal cut-off for the discrimination between PJI and non-PJI samples was determined. PJI was defined as detection of the same bacterial species in a minimum of two microbiological samples, positive histology, and presence of a sinus tract or intra-articular pus.