Advertisement for orthosearch.org.uk
Results 1 - 20 of 1325
Results per page:
Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims

Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.

Methods

Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m2 (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 19 - 19
1 Nov 2021
Schreurs B Kuijpers M van Steenbergen L Hannink G
Full Access

The increasing number of total hip arthroplasty (THA) used in young patients will inevitably lead to more revision procedures at younger ages, especially since the outcome of primary THA in young patients is already inferior compared to older patients. However, these data are lacking in literature. The aim of this study was to determine the survival of both acetabular and femoral components placed during primary and revision hip arthroplasty in patients under 55 years using Dutch Arthroplasty Register (LROI) data. All primary THA registered in the LROI between 2007–2018 in patients under 55 years were selected (n=25,682). Subsequent cup- and stem revision procedures were included. Kaplan-Meier survival analyses were used to estimate the survival probability of primary and revised cup- and stem components. Mean follow-up of primary cups and stems was 5.8 years (SD 3.2) and 5.9 years (SD 3.2), respectively. In total, 659 cup revision procedures and 532 stem revision procedures were registered. Most common reason for cup revision was acetabular loosening (n=163), most common reason for stem revision was femoral loosening (n=202). Primary cup survival for any reason at 10 years follow-up was 96.1% (95%CI: 95.7–96.4). For primary stems, 10 year survival for any reason was 97.1% (95%CI: 96.7–97.3). Mean follow-up of all revision procedures was 4.1 years (SD 2.9). Out of 659 cup revisions, 113 cup re-revisions were registered. Survival of revised cups, with end-point cup re-revision for any reason was 82.2% (95%CI: 78.8–85.1) at 5 years follow-up. Out of 532 stem revisions, 89 stem re-revisions were registered. For revised stems, survival at 5 year follow-up, with endpoint stem re-revision for any reason was 82.0% (95%CI: 78.2–85.2). The outcome of revised acetabular and femoral components is worrisome, with a survival of 82% at 5 years follow-up. This information is valuable to provide realistic expectations for these young patients at time of primary THA


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 32 - 35
1 Nov 2014
Mirza AJ Lombardi Jr AV Morris MJ Berend KR

Direct anterior approaches to the hip have gained popularity as a minimally invasive method when performing primary total hip replacement (THR). A retrospective review of a single institution joint registry was performed in order to compare patient outcomes after THR using the Anterior Supine Intermuscular (ASI) approach versus a more conventional direct lateral approach. An electronic database identified 1511 patients treated with 1690 primary THRs between January 2006 and December 2010. Our results represent a summary of findings from our previously published work. We found that patients that underwent an ASI approach had faster functional recovery and higher Harris hip scores in the early post-operative period when compared with patients who had a direct lateral approach The overall complication rate in our ASI group was relatively low (1.7%) compared with other series using the same approach. The most frequent complication was early periprosthetic femoral fractures (0.9%). The dislocation rate in our series was 0.4% and the prosthetic joint infection rate was 0.1%. We suggest that the ASI approach is acceptable and safe when performing THR and encourages early functional recovery of our patients. Cite this article: Bone Joint J 2014;96- B(11 Suppl A):32–5


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 261 - 268
1 Mar 2023
Ruhr M Huber G Niki Y Lohner L Ondruschka B Morlock MM

Aims. The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure. Methods. Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans. Results. Overimpaction reduced primary acetabular component stability (p = 0.038) but did not significantly increase strain release after implantation (p = 0.117) or plastic deformations (p = 0.193). Higher press-fits were associated with larger polar gaps for the 1 Hz reference impaction (p = 0.002, R. 2. = 0.77), with a similar trend for overimpaction (p = 0.082, R. 2. = 0.31). High-frequency impaction did not significantly increase primary stability (p = 0.170) at lower impaction forces (p = 0.001); it was associated with smaller plastic deformations (p = 0.035, R. 2. = 0.34) and a trend for increased acetabular component relaxation between strokes (p = 0.112). Higher press-fit was not related to larger polar gaps for the 6 Hz impaction (p = 0.346). Conclusion. Overimpaction of press-fit acetabular components should be prevented since additional strokes can be associated with increased bone damage and reduced primary stability as shown in this study. High-frequency impaction at 6 Hz was shown to be beneficial compared with 1 Hz impaction. This benefit has to be confirmed in clinical studies. Cite this article: Bone Joint J 2023;105-B(3):261–268


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 50 - 50
23 Jun 2023
Zagra L D'Apolito R Tonolini S Battaglia AG
Full Access

Stem loosening can be associated with a wide spectrum of bone loss and deformity that represent key factors for choosing the most appropriate revision implant. The aim of this study was to evaluate the clinical outcomes and the survivorship of a consecutive series of THA revisions using a taper rectangular cementless stem for primary implants (Alloclassic® Zweymuller®, Zimmer Warsaw US) at medium-term follow-up. We retrospectively evaluated 113 patients (115 revisions) who underwent femoral revision with Zweymuller stem with a preoperative Paprosky I (86) or II (29) defects from January 2011 to December 2020. The mean follow up was 6 years (2–10). The median age at time of surgery was 71(41–93) with 60 males and 53 females. Osteolysis/radiolucency were observed in the following Gruen zones: I (91), II (3), III (2), VII (15), V (3), VI (1). Clinical assessment was performed by means of Harris Hip Score (HHS) and Visual Analogic Scale (VAS), whereas for the radiological analysis we used conventional x-rays of the hips. The statistical analysis was performed using Graphpad Prism v5.0 and data distribution was assessed by Shapiro-Wilk test, and Wilcoxon matched paired test was used to test the differences between preoperative and postoperative score. 9 patients were lost to fu (deceased or not available), 104 (106 hips) were evaluated. The mean HHS and VAS significantly improved at final follow-up, going from 33,84 and 5,78 preoperatively to 66,42 and 2,05 postoperatively, respectively. 28 patients (25%) showed unprogressive radiolucent lines in Gruen zones 1 and 7 with no other radiological nor clinical signs of loosening. One patient suffered from recurrence of the infection. The survivorship with stem revision as endpoint was 100%. Alloclassic Zweymüller primary stem showed good medium-term results and survival rate in revision THA for aseptic loosening and second stages of two stage revisions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 39 - 39
2 May 2024
Saroha S Raheman F Jaiswal P Patel A
Full Access

In this study, we examined the impact of dual-mobility (DM) versus fixed-bearing (FB) implants on outcomes following total hip arthroplasty (THA), a common and successful operation. We examined all-cause revision, revision due to dislocation, postoperative complications and functional scores in patients undergoing primary and revision THA. A systematic review was performed according to PRISMA guidelines, and was registered in PROSPERO (ID CRD42023403736). The Cochrane Library, Embase, MEDLINE, Web of Science, and Scopus were searched from inception to 12th March 2023. Eligible studies underwent meta-analysis and methodological assessment using the ROBINS-I tool. Data were pooled using a random-effects maximum-likelihood model. Eight comparative, non-randomised studies involving 2,810 DM implants and 3,188 FB implants were included. In primary THA, the difference in all-cause revision was imprecise (OR 0.82, 95% CI 0.25–2.72), whilst the DM cohort had a statistically significant benefit in revision due to dislocation (OR 0.08, 95% CI 0.02–0.28). In revision THA, the DM cohort showed significant benefit in all-cause revision (OR 0.57, 95% CI 0.31–1.05) and revision due to dislocation (OR 0.14, 95% CI 0.04–0.53). DM implants were associated with a lower incidence of implant dislocation and infection. Functional outcome analysis was limited due to underreporting. No intraprosthetic dislocations were observed. The results suggest that contemporary DM designs may be advantageous in reducing the risk of all-cause revision, revision due to dislocation, and postoperative complication incidence at mid-term follow-up. Further high-quality prospective studies are needed to evaluate the long-term performance of this design, especially in revision cases


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 9 - 9
1 Aug 2021
Farrow L Gaba S Ashcroft G
Full Access

The rising prevalence of osteoarthritis, associated with an ageing population, is expected to deliver increasing demand across Scotland for arthroplasty services in the future. Understanding the scale of potential change to operative workflow is essential to ensure adequate provision of services and prevent prolonged waiting times that can cause patient harm. This future service demand for primary and revision hip arthroplasty across Scotland, and the rest of the U.K., is hitherto unknown. We set out to provide projections of future primary & revision hip arthroplasty out to 2038 utilising historical trend data (2008–2018) from the Scottish Arthroplasty Project. All analyses were performed using the Holt's exponential smoothing projection method with the forecast package in R statistics. Results were adjusted for projected future population estimates provided by National Records of Scotland. Independent age & sex group predictions were also performed. All results are presented per 100,000 population at-risk per year (/100k/year). The predicted rise of primary hip arthroplasty for all ages is from 120/100k/year in 2018 to 152/100k/year in 2038, a 27% increase. Based on a static 3 day length of stay average this would see 4280 additional patient bed days required for primary hip arthroplasty patients per annum. The number of revision hip arthroplasty procedures for all ages is projected to fall from 14/100k/year to 4/100k/year based on historical trend data. This does not however take into account the suspect increase in primary arthroplasty numbers that is likely to influence future revision rates. Anticipated future demand for primary hip arthroplasty will require significant additional resource and funding to prevent deterioration in quality of care and an increase in patient wait times. Demand for revision arthroplasty is set to decrease, likely on account of improved implant materials, technique, and understanding of best practice to minimise complication risk. This doesn't however take into account the impact of the complex interaction between an increasing primary arthroplasty rate and revision risk. Understanding presented projections of changes to arthroplasty demand is key to future service delivery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 61 - 61
2 May 2024
Shah JZ Bubak S Sami WA Quraishi S
Full Access

Alcohol hand rubs, endorsed by WHO and NICE guidelines, are integral to modern surgical practices. Our objective was to assess how different scrubbing methods impact overall water usage by the surgical team, shedding light on variations among team members and their environmental implications. Over three consecutive arthroplasty lists spanning a week, water usage during scrubbing was observed for the operating team. Blinding all team members, including the anesthetist, consultant surgeon, orthopaedic registrar, orthopaedic SHO, and scrub nurse, during water usage calculations was implemented. Automated taps, using motion sensors, posed a challenge due to variable water quantity, necessitating water flow calculations per sensor movement. The senior surgeon, with over 20 years of experience, follows a traditional approach, starting with a morning prescrub and using an alcohol tub for each case, except when hands are soiled. We observed a total of 14 cases of lower limb primary arthroplasty. The cumulative water usage for scrubbing by the entire team was 193 liters, yielding a mean of 13.8 liters (±1.85) per case. The anaesthetist demonstrated the most conservative water usage, utilizing a total of 11.85 liters with a mean of 0.84 liters per case. Notably, alcohol rub was employed for half of the observed time, contributing to this efficient use. The senior operating surgeon used a total of 15.6 liters, averaging 1.1 liters per case. In contrast, the SHO and the registrar exhibited the highest water consumption, totaling 121.6 liters and yielding a mean of 5.7 liters per case. The nurses’ collective water usage for scrubbing amounted to 44.8 liters. Adopting alcohol rub, as endorsed by WHO, results in a remarkable 10-fold reduction in water usage, aligning with global health guidelines. This highlights significant potential for resource conservation in surgical procedures, presenting a practical and environmentally conscious approach to surgical scrubbing practices


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 12 - 12
19 Aug 2024
Zagra L Ding B Sciamanna L D'Apolito R
Full Access

This study aimed to verify the hypothesis that an antibiotic loaded hydrogel, defensive antimicrobial coating (DAC), reduces overall complication and infection rates when used for high-risk primary and revision total hip arthroplasty (THA). This was a retrospective study matched cohort study of 238 patients, treated with cementless implants with and without DAC. A sub-group analysis of patients undergoing 2nd stage revision THA for prosthetic joint infection (PJI) was also conducted. Re-infection rates within 2 years, complications necessitating surgical intervention and radiographic analysis for aseptic loosening was assessed. The mean age was 68.3±11.5 years, with 39 (32.8%) Macpherson class A, 64 (53.8%) class B and 16 (13.4%) class C patients. 4 (3.4%) patients in the DAC group developed complications including 1 PJI and 1 delayed wound healing, while 13 (10.9%) patients in the control group developed complications including 5 PJIs and 3 delayed wound healing (p=0.032). PJI rates (p=0.136) and delayed wound healing rates (p=0.337) were not statistically significant. For 2nd stage revision THA for PJI there were 86 patients in the DAC group and 45 in the control group. 1 (1.2%) patient in the DAC group developed complications with no recurrences of infection or delayed wound healing, while 10 (22.2%) patients in the control group developed complications including 4 recurrent PJI and 1 delayed wound healing (p=0.003). Recurrent PJI rates were statistically significant (p=0.005) while delayed wound healing rates were not (p=0.165). Patients treated with DAC also had lower rates of aseptic loosening (0% vs 6.7%; p=0.015). Antibiotic impregnated hydrogel coatings on cementless implants showed decreased complication rates after complex primary or revision THA. In 2nd stage revision THA for PJI, it was associated with reduced risk of re-infection and aseptic loosening


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 28 - 28
2 May 2024
Coward A Stephen A Dokic K
Full Access

Within an ageing population, the morbidity and mortality burden of neck of femur fractures will only worsen. Financially incentivising acute Trusts via the Best Practice Tariff for inpatient care has yielded good results(1,2,3,4) but post-discharge care is still variable. Most importantly, restoring patients to their pre-fracture mobility is key to their quality of life(5,6) and reducing both readmissions to hospital(7,8) and expensive local authority residential care. Unfortunately, physiotherapist vacancies are in their thousands(9,10) leading to waiting times of around three months once discharged(11). In 2019, the Royal Derby Hospital created a novel Hip Fracture Patient Advocate (HFPA) to observe those who have fallen through gaps in community services. It involves monitoring patients’ progression, signposting to appropriate services, flagging issues to the responsible consultant and assisting in physical mobilisation. A retrospective review examined data from patients discharged to their own homes. This included demographics, residential status and mobility, both pre-fracture and at 120 days post-fracture. Mobility was classified into five categories, in line with the national hip fracture database. In 2018, of 238 patients, 41.2% returned to their baseline or increased mobility, and, after the introduction of the HFPA in 2019, this figure increased to 48.2%. In one year, there was a 7% increase in patients recovering their baseline mobility. This is a cost-effective intervention that can successfully improve mobility, leading to improved long-term outcomes. This includes the potential to reduce acute readmissions and the need for residential care, appealing to Integrated Care Boards. It also bridges the gap to primary care to optimise medical management and after further development, could be financially-incentivised via the Best Practice Tariff. Rather than thinking more expensive clinicians are required, this study proposes that a HFPA can garner better outcomes for both the patient and the wider system


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 56 - 56
19 Aug 2024
McCalden RW Vasarhelyi EM Howard JL Lanting BA Naudie DD MacDonald SJ
Full Access

For over a decade, modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. The aim of this study was to report the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years follow-up. We identified 126 patients who received a single monoblock TFT stem - 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous prosthetic joint infection (PJI), 42 for aseptic loosening, 9 for trunnionosis, 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3 months follow-up were determined. We evaluated the number and indications for re-operations. The mean time from surgery was 3.9 years (range 2.0 to 6.9 years). A paired t-test analysis showed significant improvement from pre-operative versus post-operative clinical outcome scores (p<0.001) for HHS (38.76 +/- 15.24vs. 83.42 +/- 15.38), WOMAC (45.6 ± 19.0 vs. 69.9 ± 21.3) and SF-12 Physical component (31.7 ± 8.1 vs. 37.8 ± 11.3) and SF-12 Mental component (48.2 ± 12.2 vs. 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%) and Grade 4 (1.6%) cases. There were 18 re-operations (14.7%) with 13 for PJI (7 treated with implant retention, 6 treated with a two-staged revision), 4 for instability and one for acetabular aseptic loosening. There were no aseptic failures of the stem. This novel modern monoblock TFT stem provided reliable femoral fixation and has increasingly supplanted the use of modular TFT stems for complex primary and revision surgery in our institution


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 85 - 89
1 Jul 2020
Barrack TN Abu-Amer W Schwabe MT Adelani MA Clohisy JC Nunley RM Lawrie CM

Aims. Routine surveillance of primary hip and knee arthroplasties has traditionally been performed with office follow-up visits at one year postoperatively. The value of these visits is unclear. The present study aims to determine the utility and burden of routine clinical follow-up at one year after primary arthroplasty to patients and providers. Methods. All patients (473) who underwent primary total hip (280), hip resurfacing (eight), total knee (179), and unicompartmental knee arthroplasty (six) over a nine-month period at a single institution were identified from an institutional registry. Patients were prompted to attend their routine one-year postoperative visit by a single telephone reminder. Patients and surgeons were given questionnaires at the one-year postoperative visit, defined as a clinical encounter occurring at nine to 15 months from the date of surgery, regarding value of the visit. Results. Compliance with routine follow-up at one year was 35%. The response rate was over 80% for all questions in the patient and clinician surveys. Overall, 75% of the visits were for routine surveillance. Patients reported high satisfaction with their visits despite the general time for attendance, including travel, being over four hours. Surgeons found the visits more worthwhile when issues were identified or problems were addressed. Conclusion. Patient compliance with follow-up at one year postoperatively after primary hip and knee is low. Routine visits of asymptomatic patients deliver little practical value and represent a large time and cost burden for patients and surgeons. Remote strategies should be considered for routine postoperative surveillance primary hip and knee arthroplasties beyond the acute postoperative period. Cite this article: Bone Joint J 2020;102-B(7 Supple B):85–89


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 5 - 5
1 Nov 2021
DeMik D Carender C Glass N Brown T Bedard N Callaghan J
Full Access

Reported incidence of blood transfusion following primary and revision total hip arthroplasty (pTHA, rTHA) has decreased considerably compared to historical rates. However, it is not known if further adoption of techniques to limit transfusions has resulted in further reduction on a large scale. The purpose of this study was to assess recent trends in blood transfusions and contemporary risk factors for transfusions using a large, national database. The American College of Surgeons National Surgical Quality Improvement Program was queried to identify patients undergoing pTHA and rTHA between 2011 to 2019. pTHA for fracture, infection, tumor, and bilateral procedures were excluded. Only aseptic rTHA were included. Annual incidence of transfusions and proportion of patients with optimized preoperative hematocrit (HCT) (defined as ≥33%) were assessed. Risk factors for transfusion were evaluated with 2018 and 2019 data using multivariate analyses. 234,352 pTHA and 16,322 rTHA were included. Transfusion following pTHA decreased from 21.4% in 2011 to 2.5% in 2019 and from 33.5% in 2011 to 12.0% in 2019 for rTHA (p<0.0001). Patients with optimized HCT increased for pTHA (96.7% in 2011 vs 98.1% in 2019, p<0.0001) and did not change for rTHA (91.5% in 2011 vs 91.6% in 2019, p=0.27). Decreased HCT was most strongly associated with transfusions, with each three-point change corresponding to odds ratio of 1.90 and 1.78 for pTHA and rTHA, respectively. Increased age, female sex, history of bleeding disorders or preoperative transfusion, ASA score ≥3, non-spinal anesthesia, and longer operative times were also associated with increased odds for transfusion. Incidence of blood transfusion has continued to decrease following pTHA and rTHA. Despite care improvements, transfusions still occur in certain high-risk patients. While transfusion in pTHA may have reached the lower asymptote, further reduction in rTHA may be possible through further improvements in preoperative optimization and surgical technique


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 34 - 34
1 Oct 2020
Lombardi AV
Full Access

Background. Ultraporous metals have now been used in acetabular reconstruction for two decades with excellent survival. The purpose of this study is to evaluate a newer porous metal made from Ti6Al4V titanium alloy in complex primary and revision hip arthroplasty. Methods. A retrospective review as performed on all total hip arthroplasty (THA) procedures in which a G7 Osseo-Ti (Zimmer Biomet, Warsaw, IN) acetabular component was used between 2015 and 2017. Patients with 2-year minimum follow-up or failure were included, yielding a cohort of 123 patients (126 hips). There were 50 male patients (41%; 51 hips) and 73 females (59%; 75 hips). Mean age was 65 years (range, 43–88) and mean BMI was 30.7 kg/m. 2. (range, 18–56). Indications for ultraporous metal components were in hips with compromised bone stock or severe acetabular deformity. Procedures were 35 complex primary THA and 91 revision THA that included 12 conversions and 24 reimplantations as part of 2-staged exchange for treatment of infection. Results. With an average 3.3-year follow-up (range, 2–5 years), 1 hip in the primary series (2.9%) and 4 hips in the revision series (4.4%) were revised for aseptic loosening of the acetabular component. Three of these re-revisions required custom triflange devices. Five patients (4%) failed for periprosthetic infection, which included 1 primary THA done for rheumatoid arthritis and post-radiation necrosis, and 4 second-stage reimplantation revision THAs for prior infection. Two revision patients, one done for active instability and one multiply revised, subsequently dislocated and required liner revision to constrained constructs. Kaplan-Meier analysis to endpoint of acetabular revision for aseptic loosening was 96.6% (±3.4%) in the primary series and 95.3% (±2.3%) in the revision series. Conclusion. This three-dimensionally printed ultraporous titanium acetabular component demonstrated promising early results in complex primary and revision total hip arthroplasty


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 31 - 31
2 May 2024
Stedman T Hatfield T McWilliams A
Full Access

Arthroplasty in patients who are intravenous drug abusers presents a complex challenge, frequently requiring intervention at a younger age. The cohort suffer increased complication rates due to significant co-morbidities and poor engagement in medical services, in comparison to other patients undergoing lower limb arthroplasty. Multiple small studies show arthroplasty in this patient cohort is associated with high complication and mortality rates.

A search of electronic databases were undertaken with the assistance of the library services from the Rotherham NHS Foundation Trust, including Chocraine, SCOPUS and PubMed.

Abstracts were reviewed and relevant studies extracted for full review. Full text articles were reviewed based on strict inclusion and exclusion criteria.

Searches identified Two thousand and forty-four papers; twenty-seven studies were identified for full review of the paper based on the inclusion criteria above. From this, nine studies were deemed appropriate to for data extraction.

These nine papers present one hundred and thirty-two cases of lower limb arthroplasty, fifty nine Total Knee Arthroplasty and seventy three Total Hip Arthroplasty. From this the authors examined incidences of implant failure due to infection, revision, mortality, dislocation, aseptic loosening, peri-prosthetic fracture, or other causes. Of these, 58% of patients (n = 77) with a history of intravenous drug abuse suffered some form of significant complication; 4% of this cohort (n = 5) were lost to follow up. Infection was reported in 32% of cases and a mortality rate of 4.7%.

The rising demand of lower limb arthroplasty for intra-venous drug abusers presents a very real problem for the modern Orthopaedic surgeon. Within the studies examined, more than half report implant failure. This study synthesises the available literature regarding treatment of these patients to help facilitate decision making and informed consent.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 13 - 13
1 Jul 2020
Stone M Smith L Kingsbury S Czoski-Murray C Judge A Pinedo-Villanueva R West R Wright J Smith C Arden N Conaghan P
Full Access

Follow-up of arthroplasty varies widely across the UK. The aim of this NIHR-funded study was to employ a mixed-methods approach to examine the requirements for arthroplasty follow-up and produce evidence-based and consensus-based recommendations. It has been supported by BHS, BASK, BOA, ODEP and NJR. Four interconnected work packages have recently been completed: (1) a systematic literature review; (2a) analysis of routinely collected National Health Service data from four national data sets to understand when and which patients present for revision surgery; (2b) prospective data regarding how patients currently present for revision surgery; (3) economic modelling to simulate long-term costs and quality-adjusted life years associated with different follow-up care models and (4) a Delphi-consensus process, involving all stakeholders, to develop a policy document to guide appropriate follow-up care after primary hip and knee arthroplasty. We will present the following Recommendations:. For ODEP10A∗ minimum implants, it is safe to disinvest in routine follow-up from 1 to 10 years post non-complex hip and knee replacement provided there is rapid access to orthopaedic review. For ODEP10A∗ minimum implants in complex cases, or non-ODEP10A∗ minimum implants, periodic follow-up post hip and knee replacement may be required from 1 to 10 years. At 10 years post hip and knee replacement, we recommend clinical, which may be virtual, and radiographic evaluation. After 10 years post hip and knee replacement, frequency of further follow-up should be based on the 10-year assessment; ongoing rapid access to orthopaedic review is still required. Overarching statements. These recommendations apply to post primary hip and knee replacement follow-up. The 10-year time point in these recommendations is based on a lack of robust evidence beyond ten years. The term complex cases refer to individual patient and surgical factors that may increase the risk for replacement failure


Implants in total hip replacement (THR) are associated with different clinical and cost-effectiveness profiles,. We estimate the costs and outcomes for NHS patients in the year after THR associated with implant bearing materials using linked routinely collected data. We linked NJR primary elective THR patients for osteoarthritis to HES and National PROMs. We estimated health care costs, health-related quality of life indices, and revision risks, in the year after primary and revision THRs overall. We used generalised linear models adjusting for patient and hospital characteristics and estimated 10-year cumulative probability of revision. We imputed utilities using chained equations for half the sample with missing PROMS. We linked 577,973 elective primary THRs and 11,812 subsequent revisions. One year after primary THR, patients with the cemented THRs using cobalt chrome or stainless steel head with HCLPE liner/cup cost the NHS, on average, £13,101 (95%CI £13,080,£13,122), had an average quality-of-life score of 0.788 (95%CI 0.787,0.788), and a 10-year revision probability of 1.9% (95%CI 1.6,2.3). Compared to the reference, patients receiving a cemented THR with delta ceramic head and HCLPE liner/cup, hybrid THR with delta ceramic head and HCLPE liner/cup, and hybrid THR with alumina head and HCLPE liner/cup had lower 1-year costs (-£572 \[95% CI -£775,-£385\], -£346 \[-£501,-£192\], -£371 \[-£574,-£168\] respectively), better quality of life (0.007 \[95% CI 0.003,0.011\], 0.013 \[0.010,0.016\], 0.009 \[0.005,0.013\] respectively), and lower 10-year revision probabilities (1.4% \[1.03,2.0\], 1.5 \[1.3,1.7\], 1.6%\[1.2,2.1\] respectively). Implant bearing materials are associated with varying mean costs and health outcomes after primary THR. Ours is the first study to derive costs and health outcomes from large, linked databases using multiple imputation methods to deal with bias. Our findings are useful for commissioning and procurement decisions and to inform a subsequent cost-effectiveness model with more granular detail on THR implant types


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 20 - 20
1 Aug 2018
Ohashi H Yo H Ikawa T Minami Y Teraoka T
Full Access

Reconstruction of massive acetabular bone defects in primary and revision THA is challenging for reconstructive joint surgeons. The use of porous metal augments is one of the options. The advantages of porous metal augments are easy to use, modularity and lack of resorption. We investigated the radiological results of porous metal augments used for massive acetabular bone defects in primary and revision THA. Forty-one hips in forty patients had porous metal augments between 2011 and 2016. Thirty of the procedures were revision arthroplasties and 11 were primary procedures (Crowe type III in 5 hips, Crowe type IV in 3, septic hip sequalae in 2 and RA in one). Four of the revisions were second-stage reimplantation after infection. The Paprosky classification for revision was 2B in 4 hips, 2C in one, 3A in 3 and 3B in 22. Regenerex augments were used in 39 hips and trabecular metal augments were used in 2. Thirty-six cups were cemented and 5 cups were uncemented. Mean follow-up was 37.6 months (range, 1–82). Radiographic findings of osteointegration between host bone and the porous metal augments were assessed. The presence or absence of radiolucent lines between cement or cup/host bone and augment/host bone interface was noted. Two revisions were performed due to infection, one month and 66 months after operation. The other implants were stable without any complications. Osteointegration between host bone and the porous metal augments were recognized in 36 hips. Radiolucent lines between cement/host bone interface, less than 1 mm in width, were visualized in 2 hips. Porous metal augments are convenient and our short-term results showed excellent radiological results for massive acetabular bone defects in primary and revision THA


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 71 - 77
1 Jul 2020
Gonzalez Della Valle A Shanaghan KA Nguyen J Liu J Memtsoudis S Sharrock NE Salvati EA

Aims. We studied the safety and efficacy of multimodal thromboprophylaxis in patients with a history of venous thromboembolism (VTE) who undergo total hip arthroplasty (THA) within the first 120 postoperative days, and the mortality during the first year. Multimodal prophylaxis includes discontinuation of procoagulant medications, VTE risk stratification, regional anaesthesia, an intravenous bolus of unfractionated heparin prior to femoral preparation, rapid mobilization, the use of pneumatic compression devices, and chemoprophylaxis tailored to the patient’s risk of VTE. Methods. Between 2004 to 2018, 257 patients with a proven history of VTE underwent 277 primary elective THA procedures by two surgeons at a single institution. The patients had a history of deep vein thrombosis (DVT) (186, 67%), pulmonary embolism (PE) (43, 15.5%), or both (48, 17.5%). Chemoprophylaxis included aspirin (38 patients), anticoagulation (215 patients), or a combination of aspirin and anticoagulation (24 patients). A total of 50 patients (18%) had a vena cava filter in situ at the time of surgery. Patients were followed for 120 days to record complications, and for one year to record mortality. Results. Postoperative VTE was diagnosed in seven patients (2.5%): DVT in five, and PE with and without DVT in one patient each. After hospitalization, three patients required readmiss-ion for evacuation of a haematoma, one for wound drainage, and one for monitoring of an elevated international normalized ratio (INR). Seven patients died (2.5%). One patient died five months postoperatively of a PE during open thrombectomy. She had discontinued anticoagulation. One patient died of a haemorrhagic stroke while receiving Coumadin. PE or bleeding was not suspected in the remaining five fatalities. Conclusion. Multimodal prophylaxis is safe and effective in patients with a history of VTE. Postoperative anticoagulation should be prudent as very few patients developed VTE (2.5%) or died of suspected or confirmed PE. Mortality during the first year was mostly unrelated to either VTE or bleeding. Cite this article: Bone Joint J 2020;102-B(7 Supple B):71–77


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 103 - 110
1 Jul 2021
Chalmers BP Lebowitz JS Chiu Y Joseph AD Padgett DE Bostrom MPG Gonzalez Della Valle A

Aims. Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions. Methods. We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model. Results. A discharge prescription of < 400 MMEs was not a risk factor for opioid represcribing in the entire population (p = 0.772) or in opioid-naïve patients alone (p = 0.272). Procedure type was the most significant risk factor for narcotic represcribing, with unilateral TKA (hazard ratio (HR) = 5.62), bilateral TKA (HR = 6.32), and bilateral unicompartmental knee arthroplasty (UKA) (HR = 5.29) (all p < 0.001) being the highest risk for refills. For these three procedures, there was approximately a 5% to 6% increase in refills from P1 to P3 (p < 0.001); however, there was no significant increase in refill rates after any hip arthroplasty procedures. Total MMEs prescribed were significantly reduced from P1 to P3 (p < 0.001), leading to the equivalent of nearly 500,000 fewer oxycodone 5 mg tablets prescribed. Conclusion. Decreasing opioids prescribed at discharge led to a statistically significant reduction in total MMEs prescribed. While the represcribing rate did not increase for any hip arthroplasty procedure, the overall refill rates increased by about 5% for most knee arthroplasty procedures. As such, we are now probably prescribing an appropriate amount of opioids at discharge for knee arthroplasty procedure, but further reductions may be possible for hip arthroplasty procedures. Cite this article: Bone Joint J 2021;103-B(7 Supple B):103–110