Introduction. Computer hexapod assisted orthopaedic surgery (CHAOS) has previously been shown to provide a predictable and safe method for correcting multiplanar femoral deformity. We report the outcomes of tibial deformity correction using CHAOS, as well as a new cohort of femoral CHAOS procedures. Materials and Methods. Retrospective review of medical records and radiographs for patients who underwent CHAOS for lower limb deformity at our tertiary centre between 2012–2020. Results. There were 70 consecutive cases from 56 patients with no loss to follow-up. Mean age was 40 years (17 to 77); 59% male. There were 48 femoral and 22 tibial procedures. Method of fixation was intramedullary nailing in 47 cases and locking plates in 23. Multiplanar correction was required in 43 cases. The largest correction of rotation was 40 degrees, and angulation was 28 degrees. Mean mechanical axis deviation reduction per procedure was 17.2 mm, maximum 89 mm. Deformity correction was mechanically satisfactory in all patients bar one who was under-corrected, requiring revision. Complications from femoral surgery included one under-correction, two cases of non-union, and one pulmonary embolism. Complications from tibial surgery were one locking
A reverse total shoulder arthroplasty (RSA) is frequently performed in the revision setting. The purpose of this study was to report the clinical outcomes and complication rates following revision RSA (RRSA) stratified according to the primary shoulder procedure undergoing revision, including failed hemiarthroplasty (HA), anatomic total shoulder arthroplasty (TSA), RSA, soft tissue repair (i.e., rotator cuff repair), and open reduction internal fixation (ORIF). A systematic review of the literature was performed using four databases (EMBASE, Medline, SportDISCUS, and Cochrane Controlled Trials Register) between January 1985 and September 2017. The primary outcomes of interest included active range-of-motion (ROM), pain, and functional outcome measures including the American Shoulder and Elbow Surgeons Score (ASES), Simple Shoulder Test (SST), and Constant-Murley (CS) Score. Secondary outcomes included complication rates, such as infection, dislocation, perioperative fracture, base
Introduction. Failure of intertrochanteric fracture fixation often occurs in patients, who have poor bone quality, severe osteoporosis, or unstable fracture patterns. Hip arthroplasty is a good replacement procedure even though it involves technical issues such as implant removal, bone loss, poor bone quality, trochanteric nonunion and difficulty of surgical exposure. The purpose of this study is to evaluate the outcomes of total hip arthroplasty (THA) as the replacement for failed fixation of intertrochanteric fractures of the femur. Patients and Methods. 203 patients of failed intertrochanteric fractures between April 2009 and October 2014 were included in the study. All of them underwent total hip arthroplasty through direct lateral approach. 150 patients were male (73.8%) and 53 patients (26.1%) were female and the mean of age was 59.02±10.34 years old (range: 56–90 years). The indications of the failure were nail cut out in 174 (85.7%), non-union in 15 (7.3%),
Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.