Introduction. Several short femoral stems have been introduced in primary total hip arthroplasty, supposedly in order to save proximal bone stock. We intended to analyse primary stability, changes in periprosthetic bone mineral density (BMD), and clinical outcome after insertion of the uncemented collum femoris preserving (CFP)-femoral device. Methods. A prospective cohort study on 30 patients scheduled for receiving the CFP-stem combined with an uncemented cup was carried out. Stem migration was analysed by radiostereometry (RSA). Preoperative total hip BMD and postoperative periprosthetic BMD in Gruen zones 1–7 was investigated by DXA, and the Harris hips score (HHS) was determined. The patients were followed up to 12 months. Results. 2 patients were intraoperatively excluded because their proximal femur was found to be unsuitable for insertion of the studied implant, 1 patient was later revised due to a deep infection. This left 27 patients for final analysis. RSA showed that only very little migration of the implant occurred, with the largest amplitude found in rotation around the y-axis (1.8°, SD 0.6, after 12 mths), representing minimal stem retroversion. DXA after 12 mths demonstrated substantial BMD loss in Gruen zones 7 (−30.8%), 6 (−19.1%) and 2 (−13.3%, p-values for all described changes <0.001 when comparing with baseline BMD determined immediately postoperatively). There was a moderate correlation of low preoperative total hip BMD with a higher amount of bone loss in Gruen zones 2 (Pearson correlation coefficient r = 0.6, p = 0.001), 6 (r = 0.5, p = 0.005) and 7 (r = 0.6, p = 0.003). In contrast, we found no correlation of