Advertisement for orthosearch.org.uk
Results 1 - 18 of 18
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 36 - 36
11 Apr 2023
Boyce S Le Maitre C Smith T Nichol T
Full Access

An increasing elderly population means joint replacement surgery numbers are projected to increase, with associated complications such as periprosthetic joint infections (PJI) also rising. PJI are particularly challenging due to antimicrobial resistant biofilm development on implant surfaces and surrounding tissues, with treatment typically involving invasive surgeries and systemic antibiotic delivery. Consequently, functionalisation of implant surfaces to prevent biofilm formation is a major research focus. This study characterises clinically relevant antimicrobials including gentamicin, clindamycin, daptomycin, vancomycin and caspofungin within a silica-based, biodegradable sol-gel coating for prosthetic devices. Antimicrobial activity of the coatings against clinically relevant microorganisms was assessed via disc diffusion assays, broth microdilution culture methods and the MBEC assay used to determine anti-biofilm activity. Human and bovine cells were cultured in presence of antimicrobial sol-gel to determine cytotoxicity using Alamar blue and antibiotic release was measured by LC-MS. Biodegradability in physiological conditions was assayed by FT-IR, ICP-MS and measuring mass change. Effect of degradation products on osteogenesis were studied by culturing mesenchymal stem cells in the presence of media in which sol-gel samples had been immersed. Antimicrobial-loaded coatings showed strong activity against a wide range of clinically relevant bacterial and fungal pathogens with no loss of activity from antibiotic alone. The sol-gel coating demonstrated controlled release of antimicrobials and initial sol-gel coatings showed no loss of viability on MSCs with gentamicin containing coatings. Current work is underway investigating cytotoxicity of sol-gel compositions against MG-63 cells and primary osteoblasts. This research forms part of an extended study into a promising antimicrobial delivery strategy to prevent PJI. The implant coating has potential to advance PJI infection prevention, reducing future burden upon healthcare costs and patient wellbeing


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 96 - 96
1 Nov 2018
Atkins GJ
Full Access

Periprosthetic joint infections (PJI) are increasing in prevalence and are recognised as one of the most common modes of failure of joint replacements. Osteomyelitis arising from PJI is challenging to treat, difficult to cure and increases patient mortality 5-fold. PJI can have subtle symptoms and lie dormant or go undiagnosed for many years, suggesting persistent bacterial infection. Staphylococcus aureus is the most common pathogen causing PJI. Osteocytes are the most numerous and long-lived cell type in hard bone tissue. Our recent work has shown that S. aureus can infect and reside in human osteocytes without causing cell death, both experimentally and in bone samples from patients with PJI. Osteocytes respond to infection by the differential regulation of a large number of genes, suggesting previously unknown immune functions of this important cell type. S. aureus adapts during intracellular infection of osteocytes by adopting a quasi-dormant, small colony variant (SCV) phenotype, a property of several bacterial species known to cause PJI, which could contribute to persistent or silent infection. These findings shed new light on the aetiology of PJI and osteomyelitis in general. Further elucidation of the role of osteocytes in bone infection will hopefully lead to improved disease detection and management


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 42 - 42
1 Nov 2018
Kobayashi N Inaba Y Choe H Tomoyama A Ike H Saito T
Full Access

While stable long-term clinical results have been achieved in total joint arthroplasty, periprosthetic joint infection (PJI) has been actualized as difficult issue in this decade. For accurate diagnosis, it is important to establish standard criteria such as MSIS criteria, and it is prevailing now. As an issue involving PJI, however, the existence of viable, but non-culturable (VNC) bacteria must be noticed. It is difficult to identify the VNC state infection, because microbiologic culture result shows negative and other markers tend to be negative. Here, molecular diagnosis based on polymerase chain reaction (PCR) has certain role as potential diagnostic tools for such VNC infection. We have applied a real-time PCR system for the diagnosis of PJI, which is able to detect methicillin-resistant Staphylococcus (MRS) and distinguish gram-positive from gram-negative bacteria. The prominent advantage is that PCR is the singular way to identify MRS in such culture negative cases. Recent development of full-automatic PCR system may improve the time efficiency for routine application. In this presentation, we will show the overall sensitivity and specificity of our PCR system for diagnosing PJI and discuss the current problem and future prospect


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 41 - 41
1 Nov 2018
Takagi M
Full Access

Immune response in periprosthetic joint infection (PJI) is diverse. Resident macrophage and/or wandering monocyte are superb guardians to sense microbial attacks, take invaders and alarm the danger. Neutrophils are refined but momentary fighters to kill microbes with projectile weapons as well as predation. The swift action is usually effective at the forefront to prevent expansion of infectious foci. However, such characteristics often evokes overshooting via self-defeating of pus, thus leading to crucial soft tissue damage in the acute phase. Intervention of monocyte/macrophages follow and act as wise organizers. In addition, stromal fibroblasts also act in front for host defence. They equip innate immune sensors (TLRs, NLRs), which can sense dangers and trigger off inflammatory response, but also is usually self-regulated. These sensors not only interact each other, but also have possible contribution to selective autophagy (xenophagy and lysophagy) in PJI. In this presentation, overview of pathology in PJI will be summarized with a special attention to innate immune sensors (TLRs and NLRs), and selective autophagy


Bone & Joint Research
Vol. 7, Issue 1 | Pages 12 - 19
1 Jan 2018
Janz V Schoon J Morgenstern C Preininger B Reinke S Duda G Breitbach A Perka CF Geissler S

Objectives. The objective of this study was to develop a test for the rapid (within 25 minutes) intraoperative detection of bacteria from synovial fluid to diagnose periprosthetic joint infection (PJI). Methods. The 16s rDNA test combines a polymerase chain reaction (PCR) for amplification of 16s rDNA with a lateral flow immunoassay in one fully automated system. The synovial fluid of 77 patients undergoing joint aspiration or primary or revision total hip or knee surgery was prospectively collected. The cohort was divided into a proof-of-principle cohort (n = 17) and a validation cohort (n = 60). Using the proof-of-principle cohort, an optimal cut-off for the discrimination between PJI and non-PJI samples was determined. PJI was defined as detection of the same bacterial species in a minimum of two microbiological samples, positive histology, and presence of a sinus tract or intra-articular pus. Results. The 16s rDNA test proved to be very robust and was able to provide a result in 97% of all samples within 25 minutes. The 16s rDNA test was able to diagnose PJI with a sensitivity of 87.5% and 82%, and a specificity of 100% and 89%, in the proof-of-principle and validation cohorts, respectively. The microbiological culture of synovial fluid achieved a sensitivity of 80% and a specificity of 93% in the validation cohort. Conclusion. The 16s rDNA test offers reliable intraoperative detection of all bacterial species within 25 minutes with a sensitivity and specificity comparable with those of conventional microbiological culture of synovial fluid for the detection of PJI. The 16s rDNA test performance is independent of possible blood contamination, culture time and bacterial species. Cite this article: V. Janz, J. Schoon, C. Morgenstern, B. Preininger, S. Reinke, G. Duda, A. Breitbach, C. F. Perka, S. Geissler. Rapid detection of periprosthetic joint infection using a combination of 16s rDNA polymerase chain reaction and lateral flow immunoassay: A Pilot Study. Bone Joint Res 2018;7:12–19. DOI: 10.1302/2046-3758.71.BJR-2017-0103.R2


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 16 - 16
1 Apr 2015
Marsh A Crighton E Yapp L Kelly M Jones B Meek R
Full Access

Successful treatment of periprosthetic joint infection involves surgical intervention and identification of infecting organisms to enable targeted antibiotic therapy. Current guidelines recommend intra-operative culture sampling to include at least 4 tissue samples and for each sample to be taken with a separate instrument. We aimed to review current revision arthroplasty practice for Greater Glasgow, specifically comparing intra-operative sampling technique for infected revision cases with these guidelines. We reviewed the clinical notes of all patients undergoing lower limb revision arthroplasty procedures in Greater Glasgow Hospitals (WIG, GRI, SGH) from July 2013 to August 2014. Demographics of all cases were collected. For revision procedures performed for infection we recorded details of intraoperative samples taken (number, type and sampling technique) and time for samples to reach the laboratory. Results of microbiology cultures were reviewed. Two hundred and fifty five revision arthroplasty procedures (152 hips, 103 knees) were performed in the 12 month study period. Of these 57 (22%) were infected cases (28 hips, 29 knees). These cases were treated by 14 arthroplasty surgeons with a median number of 3 infected cases managed per surgeon (range 1–11). 58% of cases had the recommended number of tissue samples taken. The median number of microbiology samples collected was 4 (range 1–14). Most procedures (91%) had no documentation of whether separate instruments were used for sampling. Number of tissue samples taken (≥4, p=0.01), time to lab (<24 hours, p=0.03) were significantly associated with positive culture results. In Greater Glasgow, a large number of surgeons manage infected arthroplasty cases with variability in intra-operative sampling techniques. Sample collection adheres to guideline recommendations in 58% cases. Adhering to guideline standards increases the likelihood of positive tissue cultures. Implementation of a standardised approach to intra-operative sampling for infected cases may improve patient management


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 21 - 21
4 Apr 2023
Meinshausen A Büssemaker H Viet Duc B Döring J Voropai V Müller A Martin A Berger T Schubert A Bertrand J
Full Access

Periprosthetic joint infections (PJI) are one of the most common reasons for orthopedic revision surgeries. In previous studies, it has been shown that silver modification of titanium (Ti-6Al-4V) surfaces by PMEDM (powder mixed electrical discharge machining) has an antibacterial effect on Staphylococcus aureus adhesion. Whether this method also influences the proliferation of bacteria has not been investigated so far. Furthermore, the effect is only limitedly investigated on the ossification processes. Therefore, the aim of this work is to investigate the antibacterial effect as well as the in vitro ossification process of PMEDM machined surfaces modified by integration of silver. In this study, we analyzed adhesion and proliferation of S. aureus in comparison to of surface roughness, silver content and layer thickness of the silver-integrated-PMEDM surfaces (N = 5). To test the in vitro ossification, human osteoblasts (SaOs-2) and osteoclasts (differentiated from murine-bone-marrow-macrophages) were cultured on the silver surfaces (N = 3). We showed that the attachment of S. aureus on the surfaces was significantly lower than on the comparative control surfaces of pure Ti-6Al-4V without incorporated silver, independently of the measured surface properties. Bacterial proliferation, however, was not affected by the silver content. No influence on the in vitro ossification was observed, whereas osteoclast formation was drastically reduced on the silver-modified surfaces. We showed that 1 to 3% of silver in the surface layer significantly reduced the adhesion of S. aureus, but not the proliferation of already attached bacteria. At the same time, no influence on the in vitro ossification was observed, while no osteoclasts were formed on the surface. Therefore, we state that PMEDM with simultaneous silver modification of the machined surfaces represents a promising technology for endoprostheses manufacturing to reduce infections while at the same time optimizing bone ingrowth


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 95 - 95
4 Apr 2023
Troiano E Giacomo P Di Meglio M Nuvoli N Mondanelli N Giannotti S Orlandi N
Full Access

Infections represent a devastating complication in orthopedic and traumatological surgery, with high rates of morbidity and mortality. An early intervention is essential, and it includes a radical surgical approach supported by targeted intravenous antimicrobial therapy. The availability of parenteral antibiotics at the site of infection is usually poor, so it is crucial to maximize local antibiotic concentration using local carriers. Our work aims to describe the uses of one of these systems, Stimulan®, for the management and prevention of infections at our Institution. Analysing the reported uses of Stimulan®, we identified two major groups: bone substitute and carrier material for local antibiotic therapy. The first group includes its application as a filler of dead spaces within bone or soft tissues resulting from traumatic events or previous surgery. The second group comprehends the use of Stimulan® for the treatment of osteomyelitis, post-traumatic septic events, periprosthetic joint infections, arthroplasty revision surgery, prevention in open fractures, surgery of the diabetic foot, oncological surgery and for all those patients susceptible to a high risk of infection. We used Stimulan® in several complex clinical situations: in PJIs, in DAPRI procedure and both during the first and the second stage of a 2-stage revision surgery; furthermore, we started to exploit this antibiotic carrier also in prophylaxis of surgical site infections, as it happens in open fractures, and when a surgical site remediation is required, like in osteomyelitis following ORIF. Stimulan® is an extremely versatile and polyhedric material, available in the form of beads or paste, and can be mixed to a very broad range of antibiotics to better adapt to different bacteria and their antibiograms, and to surgeon's needs. These properties make it a very useful adjuvant for the management of complex cases of infection, and for their prevention, as well


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 114 - 114
11 Apr 2023
Tay M Young S Hooper G Frampton C
Full Access

Unicompartmental knee arthroplasty (UKA) is associated with a higher risk of revision compared with total knee arthroplasty (TKA). The outcomes of knee arthroplasty are typically presented as implant survival or incidence of revision after a set number of years, which can be difficult for patients and clinicians to conceptualise. We aimed to calculate the ‘lifetime risk’ of revision for UKA as a more relatable estimate of risk projection over a patient's remaining lifetime, and make comparisons to TKA. All primary UKAS performed from 1999 to 2019 (n=13,481) captured by the New Zealand Joint Registry (NZJR) were included. The lifetime risk of revision was calculated and stratified by age, gender and American Society of Anesthesiologists (ASA) status. The lifetime risk of revision for UKA was highest in the youngest patients (46-50 years; 40.4%) and lowest in the oldest patients (86-90 years; 3.7%). Lifetime risk of revision was higher for females (range 4.3%-43.4% cf. males 2.9%-37.4%) and patients with higher ASA status (ASA 3-4 range 8.8%-41.2% cf. ASA 1 1.8%-29.8%), regardless of age. The lifetime risk of UKA was two-fold higher than TKA (ranging from 3.7%-40.4% UKA, 1.6%-22.4% TKA) across all age groups. Increased risk of revision in the younger patients was associated with aseptic loosening in both males and females, and pain in females. Periprosthetic joint infections (PJI) accounted for 4% of all UKA revisions, in contrast to 27% for TKA; risk of PJI was higher for males than females for both procedures. The lifetime risk of revision is a more meaningful measure of arthroplasty outcomes and can aid with patient counselling prior to UKA. Findings from this study show the increased lifetime risk of UKA revision for younger patients, females and those with higher ASA status


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 85 - 85
4 Apr 2023
Wulfhorst M Büssemaker H Meinshausen A Herbster M Döring J Mai V Lohmann C Kautz A Laube T Wyrwa R Schnabelrauch M Bertrand J
Full Access

The implantation of endoprosthesis is a routine procedure in orthopaedics. Endoprosthesis are mainly manufactured from ceramics, polymers, metals or metal alloys. To ensure longevity of the implants they should be as biocompatible as possible and ideally have antibacterial properties, to avoid periprosthetic joint infections (PJI). Various antibacterial implant materials have been proposed, but have so far only been used sporadically in patients. PJI is one of the main risk factors for revision surgeries. The aim of the study was to identify novel implant coatings that both exhibit antibacterial properties whilst having optimal biocompatibility. Six different novel implant coatings and surface modifications (EBM TiAl6V4, strontium, TiCuN, TiNbN, gentamicin phosphate (GP), gentamicin phosphate+cationic polymer (GP+CP)) were compared to standard CoCrMo-alloy. The coatings were further characterized with regard to the surface roughness. E. coli and S. capitis were cultured on the modified surfaces to investigate the antibacterial properties. To quantify bacterial proliferation the optical density (OD) was measured and viability was determined using colony forming units (CFU). Murine bone marrow derived macrophages (BMMs) were cultured on the surfaces and differentiated into osteoblasts to quantify the mineralisation using the alizarin red assay. All novel coatings showed reduced bacterial proliferation and viability compared to standard CoCrMo-alloy. A significant reduction was observed for GP and GP+CP coated samples compared to CoCrMo (OD. GP,E.coli. = 0.18±0.4; OD. GP+CP,E.coli. = 0.13±0.3; p≤0.0002; N≥7-8). An increase in osteoblast-mediated mineralisation was observed on all surfaces tested compared to CoCrMo. Furthermore, GP and GP+CP coated samples showed a statistically significant increase (M. GP. = 0.21±0.1; M. GP+CP. = 0.25±0.2; p<0.0001; N≥3-6). The preliminary data indicates that the gentamicin containing surfaces have the most effective antibacterial property and the highest osseointegrative capacity. The use of antibiotic coatings on prostheses could reduce the risk of PJI while being applied on osseointegrative implant surfaces


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 102 - 102
4 Apr 2023
Lu V Zhou A Hussain H Thahir A Krkovic M
Full Access

A hot swollen joint is a commonly encountered condition in clinical practice. With a broad range of differentials, septic arthritis (SA) is perhaps one of the most concerning. Treated by culture-specific antibiotics and arthroscopic lavage, some patients require multiple washouts. We aimed to determine:. (1) What are the risk factors for development of SA?. (2) What are the risk factors for repeat washout in SA patients?. (3) What are the important clinical differences between a periprosthetic joint infection (PJI) and SA cohort?. All patients presenting to the emergency department, orthopaedic, and rheumatology clinics between January 2020 to January 2021 with a hot, swollen joint were retrospectively evaluated. Patients with previous trauma on the ipsilateral joint, with data missing from their medical records in any of the variables required for analysis, <24 months follow-up were excluded. Variables of interest in the three-month period preceding the diagnosis of SA were compared between SA and non-SA patients. Factors with a p-value of p<0.100 in univariate analysis were included in a stepwise multivariate logistic regression model. Similar analyses were performed to compare SA patients with multiple washouts with those needing one washout. Demographical and clinical data for PJI patients were collected to delineate important differences with SA cohort. 211 patients were included (SA:28;PJI:24;pseudogout:32;gout:26;others:101). Multivariate analysis showed rheumatoid arthritis (RA), skin infection, and liver disease were risk factors for SA. Amongst patients with septic arthritis, multivariate analysis showed that WBC levels above normal limits (3.6-10.5×109 cells/L) and RA were risk factors for multiple washouts. Between the SA and PJI cohorts, BMI (p=0.002) was significantly lower in the former, whilst WBC level (p=0.023) and CRP (p<0.0001) was significantly higher in the former. Early diagnosis of septic arthritis requires understanding the risk factors, namely RA, skin infection, and liver disease. Considering PJI and septic arthritis as the same entity can lead to wrong clinical judgement, and clinicians should be aware of important differences. We believe that the models in this study are of prognostic value to clinicians who are presented with the common presenting compliant of a hot swollen joint


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 31 - 31
11 Apr 2023
Powell D Wu B Dietz P Bou-Akl T Ren W Markel D
Full Access

Failure of osseointegration and periprosthetic joint infection (PJI) are the two main reasons of implant failure after total joint replacement (TJR). Nanofiber (NF) implant surface coating represents an alternative local drug eluting device that improves osseointegration and decreases the risk of PJI. The purpose of this study was to investigate the therapeutic efficacies of erythromycin (EM)-loaded coaxial PLGA/PCL-PVA NF coating in a rat S. aureus-infected tibia model. NF coatings with 100mg and 1000mg EM were prepared. NF without EM was included as positive control. 56 Sprague Dawley rats were divided into 4 groups. A titanium pin (1.0-mm x 8 mm) was placed into the tibia through the intercondylar notch. S. aureus (SA) was introduced by both direct injection of 10 μl broth (1 × 10. 4. CFU) into the medullary cavity and single dip of Ti pins into a similar solution prior to insertion. Rats were sacrificed at 8 and 16 weeks after surgery. The outcome measurements include μCT based quantitative osteolysis evaluation and hard tissue histology. Results: EM-NF coating (EM100 and EM1000) reduced osteolysis at 8 and 16 weeks, compared to EM0 and negative control. The effective infection control by EM-NFs was further confirmed by hard tissue section analysis. The Bone implant contact (BIC) and bone area fraction Occupancy (BAFO) within 200 µm of the surface of the pins were used to evaluate the osseointegration and new bone formation around the implants. At 16 weeks, the bone implant contact (BIC) of EM 100 (35.08%) was higher than that of negative control (3.43%) and EM0 (0%). The bone area fraction occupancy within 200 µm (BAFO) of EM100 (0.63 mm2) was higher than that of negative control (0.390 mm2) and EM0 (0.0 mm. 2. ). The BAFO of EM100 was also higher than that of EM1000 (0.3mm. 2. ). There was much less osteolysis observed with EM100 and EM1000 NF coatings at 16 weeks, as compared to EM0 positive control, p=0.08 and p=0.1, respectively. Osseointegration and periprosthetic bone formation was enhanced by EM-NFs, especially EM100. Data from this pilot study is promising for improving implant surface fabrication strategies


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 27 - 27
1 Dec 2021
Edwards T Donovan R Whitehouse M
Full Access

Abstract. Objectives. Intra-articular corticosteroid injections (IACIs) are a well-established non-surgical treatment for the symptoms of osteoarthritis (OA), which can provide short-term improvements in pain, disability and quality of life (QoL). Many patients receive recurrent IACIs as temporary relief of their symptoms. Longer-term outcomes for recurrent IACIs remain less well-researched. This meta-analysis aimed to investigate the longer-term risks and benefits of IACIs beyond 3 months. Methods. We searched MEDLINE, EMBASE, and CENTRAL from inception to January 07, 2021, for randomised controlled trials (RCTs) where patients with OA had received recurrent IACIs. Our primary outcomes were pain and function. Secondary outcomes included QoL, disease progression, radiological changes, and adverse events. Mean differences with 95% confidence intervals were reported. Results. Ten RCTs met eligibility criteria (eight for knee OA [n=378], two for trapeziometacarpal OA [n=57]). Patients received 2–5 injections. Follow-up ranged from 6–24 months. Patients with knee OA showed mild improvement in pain at 3, 6, and 9 months but not at 12 months post-injection compared to baseline. Improvements in function were seen from 3–24 months post-injection, decreasing over time. Improvements in QoL continued at 24 months. For patients with trapeziometacarpal OA, mild improvements in pain, function, and QoL were demonstrated at 3–6 months (and 12 months for pain) compared to baseline. No serious adverse events were recorded. No studies reported on time-to-future interventions, or risk of future periprosthetic joint infection. Conclusions. Only mild improvements in pain, function, and QoL were noted after recurrent IACIs up to 6–24 months post-injection. Existing RCTs on recurrent IACI lacks sufficient follow-up data to assess disease progression and time-to-future interventions. These results will inform the RecUrrent Intra-articular Corticosteroid injections in Osteoarthritis (RUbICOn) study which aims to establish the long-term safety outcomes of IACI through data linkage of clinical practice data, hospital episode statistics, and national PROMs


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 120 - 120
1 Nov 2021
Gregori P Singh A Harper T Franceschi F Blaber O Horneff JG
Full Access

Introduction and Objective. Total shoulder replacement is a common elective procedure offered to patients with end stage arthritis. While most patients experience significant pain relief and improved function within months of surgery, some remain unsatisfied because of residual pain or dissatisfaction with their functional status. Among these patients, when laboratory workup eliminates infection as a possibility, corticosteroid injection (CSI) into the joint space, or on the periprosthetic anatomic structures, is a common procedure used for symptom management. However, the efficacy and safety of this procedure has not been previously reported in shoulder literature. Materials and Methods. A retrospective chart review identified primary TSA patients who subsequently received a CSI into a replaced shoulder from 2011 – 2018 by multiple surgeons. Patients receiving an injection underwent clinical exam, laboratory analysis to rule out infection, and radiographic evaluation prior to CSI. Demographic variables were recorded, and a patient satisfaction survey assessed the efficacy of the injection. Results. Of the 43 responders, 48.8% remembered the injection. The average time from index arthroplasty to injection was median 16.8 months. Overall, 61.9% reported decreased pain, 28.6% reported increased motion, and 28.6% reported long term decreased swelling. Improvement lasted greater than one month for 42.9% of patients, and overall 52.4% reported improvement (slight to great) in the shoulder following CSI. No patient developed a periprosthetic joint infection (PJI) within 2 years of injection. Conclusions. This study suggests that certain patients following TSA may benefit from a CSI. However, this should only be performed once clinical, radiographic, and laboratory examination has ruled out conditions unlikely to improve long term from a CSI. Given these findings, further study in a large, prospective trial is warranted to fully evaluate the benefits of CSI following TSA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 33 - 33
1 Dec 2020
Diez-Escudero A Andersson BM Järhult JD Hailer NP
Full Access

Uncemented implants combining antimicrobial properties with osteoconductivity would be highly desirable in revision surgery due to periprosthetic joint infection (PJI). Silver coatings convey antibacterial properties, however, at the cost of toxicity towards osteoblasts. On the other hand, topological modifications such as increased surface roughness or porosity support osseointregation but simultaneously lead to enhanced bacterial colonization. In this study, we investigated the antibacterial and osteoconductive properties of silver-coated porous titanium (Ti) alloys manufactured by electron beam melting, rendering a macrostructure that mimics trabecular bone. Trabecular implants with silver coating (TR-Ag) or without coating (TR) were compared to grit-blasted Ti6Al4V (GB) and glass cover slips as internal controls. Physicochemical characterization was performed by X-ray diffraction (XRD) and energy dispersive X-rays (EDX) together with morphological characterization through electron scanning microscopy (SEM). Bacterial adherence after incubation of samples with Staphylococcus (S.) aureus and S. epidermidis strains harvested from PJI patients was quantitatively assessed by viable count after detachment of adherent bacteria by collagenase/dispase treatment. Primary human osteoblasts (hOB) were used to investigate the osteoconductive potential by lactate dehydrogenase (LDH) and alkaline phosphatase (ALP) activity. Cell morphology was investigated by fluorescence microscopy after staining with carboxifluorescein diacetate succinimidyl ester (CFDA-SE) and 4′,6-diamidino-2-phenylindole (DAPI). The trabecular implants depicted a porosity of 70% with pore sizes of 600µm. The amount of silver analyzed by EDX accounted for 35%wt in TR-Ag but nil in TR. Silver-coated TR-Ag implants had 24% lower S. aureus viable counts compared to non-coated TR analogues, and 9% lower compared to GB controls. Despite trabecular implants, both with and without silver, had higher viable counts than GB, the viable count of S. epidermidis was 42% lower on TR-Ag compared to TR. The percentage of viable hOB, measured by LDH and normalized to controls and area at 1 day, was lower on both TR-Ag (18%) and on TR (13%) when compared with GB (89%). However, after 1 week, cell proliferation increased more markedly on trabecular implants, with a 5-fold increase on TR-Ag, a 3.4-fold increase on TR, and a 1.7-fold increase on GB. Furthermore, after 2 weeks of hOB culture, proliferation increased 20-fold on TR-Ag, 29-fold on TR, and 3.9-fold for GB, compared to 1 day. The osteoconductive potential measured by ALP illustrated slightly higher values for TR-Ag compared to TR at 1 day and 2 weeks, however below those of GB samples. Cell morphology assessed by microscopy showed abundant growth of osteoblast-like cells confined to the pores of TR-Ag and TR. Overall, our findings indicate that the silver coating of trabecular titanium exerts limited cytotoxic effects on osteoblasts and confers antimicrobial effects on two PJI-relevant bacterial strains. We conclude that improving material design by mimicking the porosity and architecture of cancellous bone can enhance osteoconductivity while the deposition of silver confers potent antimicrobial properties


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 123 - 123
1 Nov 2018
Lenguerrand E Whitehouse M Beswick A Kunutsor S Porter M Blom A
Full Access

Periprosthetic joint infections (PJIs) are uncommon but are devastating complications of total knee replacement (TKR). We analysed the risk factors of revision for PJI following primary TKR and their association with PJI at different post-operative periods. Primary TKRs and subsequent revision surgeries performed for PJI from 2003–2014 were identified from the National Joint Registry (NJR). Multilevel piece-wise exponential non-proportional hazards models were used to estimate the effect of the investigated factors at different post-operative periods. Patient, perioperative and healthcare system characteristics were investigated and data from the Hospital Episode Statistics for England were linked to obtain information on specific comorbidities. The index TKRs consisted of 679,010 primaries with 3,659 subsequently revised for PJI, 7% within 3 months, 6% between 3–6months, 17% between 6–12months, 27% between 1–2years and 43% ≥2 years from the index procedure. Risk factors for revision for PJI included male sex, high BMI, high ASA grade and young age. Patients with chronic pulmonary disease, diabetes and liver disease had higher risk of revision for PJI, as had patients who had a primary TKR for an indication of trauma or inflammatory arthropathy. Surgical procedure, fixation method, constraint and bearing type influenced the risk of revision for PJI. Their effects were period-specific. No or small associations were found with the operating surgeon grade, surgical volume and hospital surgical volume. These findings from the world's largest joint replacement registry show a more complex picture than the meta-analyses published to date with specific time-dependent effects for the identified risk factors


Bone & Joint 360
Vol. 9, Issue 1 | Pages 10 - 14
1 Feb 2020
Ibrahim M Reito A Pidgaiska O


Bone & Joint Research
Vol. 6, Issue 3 | Pages 132 - 136
1 Mar 2017
Yuenyongviwat V Ingviya N Pathaburee P Tangtrakulwanich B

Objectives

Vancomycin and fosfomycin are antibiotics commonly used to treat methicillin-resistant Staphylococcus aureus (MRSA) infection. This study compares the in vitro inhibitory effects against MRSA of articulating cement spacers impregnated with either vancomycin or fosfomycin.

Methods

Vancomycin-impregnated articulating cement spacers and fosfomycin-impregnated articulating cement spacers were immersed in sterile phosphate-buffered saline (PBS) solutions and then incubated. Samples were collected for bioactivity evaluation. The aliquots were tested for MRSA inhibition with the disc diffusion method, and the inhibition zone diameters were measured. The inhibition zone differences were evaluated using the Wilcoxon Rank Sum Test.