It is common belief that consolidated intramedullary nailed trochanteric femur fractures can result in secondary midshaft or supracondylar fractures, involving the distal screws, when short or long nails are used, respectively. In addition, limited data exists in the literature to indicate when short or long nails should be selected for treatment. The aim of this biomechanical cadaveric study was to investigate short versus long Trochanteric Femoral Nail Advanced (TFNA) fixation in terms of construct stability and generation of secondary fracture pattern following trochanteric fracture consolidation. Eight intact human cadaveric femur pairs were assigned to 2 groups of 8 specimens each for nailing using either short or long TFNA with blade as head element. Each specimen was first biomechanically preloaded at 1 Hz over 2000 cycles in superimposed synchronous axial compression to 1800 N and internal rotation to 11.5 Nm. Following, internal rotation to failure was applied over an arc of 90° within 1 second under 700 N axial load. Torsional stiffness, torque at failure, angle at failure and energy at failure were evaluated. Fracture patterns were analyzed. Outcomes in the groups with short and long nails were 9.7±2.4 Nm/° and 10.2±2.9 Nm/° for torsional stiffness, 119.8±37.2 Nm and 128.5±46.7 Nm for torque at failure, 13.5±3.5° and 13.4±2.6° for angle at failure, and 887.5±416.9 Nm° and 928.3±461.0 Nm° for energy at failure, respectively, with no significant differences between them, P≥0.167. Fractures through the distal locking screw occurred in 5 and 6 femora instrumented with short and long nails, respectively. Fractures through the lateral entry site of the head element were detected in 3 specimens within each group. For short nails, fractures through the distal shaft region, not interfacing with the implant, were detected in 3 specimens. From biomechanical perspective, the risk of secondary
Aims. The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. Methods. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and
An atypical femoral fracture (AFF), with a transverse
fracture radiologically through the lateral cortex is a rare but serious
condition. In order to improve our ability to identify patients
with this condition, we retrospectively surveyed all subtrochanteric,
peri-implant and diaphyseal femoral fractures in patients aged ≥ 65
years who underwent surgical treatment at our hospital between 2004
and 2011. We describe the incidence of atypical fractures and their characteristics,
with observational data including a review of the hospital and general
practitioner records. Clinical outcomes were evaluated using the
Harris hip score (HHS) and the timed up-and-go (TUG) test. Atypical fractures only occurred in women with an incidence of
9.8 per 100 000 person-years. The incidence in those who were treated
with bisphosphonates was 79.0 per 100 000 person-years; eight of
17 fractures occurred around metal implants. There was a high incidence
of delayed union and revision surgery. A total of nine patients (ten
AFFs) were available for review at a mean follow-up of 36.5 months
(10 to 104). The clinical outcome was poor with a mean HHS of 58.9
(95% CI 47.4 to 70.4) and a mean TUG test of 25.7 s (95% CI 12.7
to 38.8). The delay in diagnosis and treatment of AFF may result from a
lack of knowledge of this condition. Cite this article:
To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails. A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the AO/OTA classification was performed. Baseline characteristics of each article were obtained, complication measures were analyzed:
This study compares outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual lag screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or
Subtrochanteric femoral fractures are a subset of hip fractures generally treated with cephalomedullary nail fixation\[1\]. Single lag screw devices are most commonly-used, but integrated dual screw constructs have become increasingly popular\[2,3\]. The aim of this study was to compare outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or
Neer Type-IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. A novel plating technique using a superior lateral locking plate with antero-posterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment has been designed to enhance stability. The purpose of this study was to biomechanically compare three different clavicle plating constructs. 24 fresh-frozen cadaveric shoulders were randomised into three groups (n=8 specimens). Group 1: lateral locking plate only (Medartis Aptus Superior Lateral Plate); Group 2: lateral locking plate with CC stabilisation (Nr. 2 FiberWire); and Group 3: lateral locking plate with two AP locking screws stabilising the lateral fragment. Data was analysed for gap formation after cyclic loading, construct stiffness and ultimate load to failure, defined by a marked decrease in the load displacement curve. After 500 cycles, there was no statistically significant difference between the three groups in gap-formation (p = 0.179). Ultimate load to failure was significantly higher in Group 3 compared to Group 1 (286N vs. 167N; p = 0.022), but not to Group 2 (286N vs. 246N; p = 0.604). There were no statistically significant differences in stiffness (Group 1: 504N/mm; Group 2: 564N/mm; Group 3: 512N/mm; p = 0.712).
Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further
Introduction. Distal femur fracture fixation in elderly presents significant challenges due to osteoporosis and associated comorbidities. There has been an evolution in the management of these fractures with a description of various surgical techniques and fixation methods; however, currently, there is no consensus on the standard of care. Non-union rates of up to 19% and mortality rates of up to 26 % at one year have been reported in the literature. Delay in surgery and delay in mobilisation post-operatively have been identified as two main factors for high rate of mortality. As biomechanical studies have proved better stability with dual plating or nail-plate combination, a trend has been shifting for past few years towards rigid fixation to allow early mobilisation. Our study aims to compare outcomes of distal femur fractures managed with either single plate (SP), dual plating (DP) or nail-plate construct (NP). Methods. A retrospective review of patients aged above 65 years with distal femur fractures (both native and peri-prosthetic) who underwent surgical management between June 2020 and May 2023 was conducted. Patients were divided into three groups based on mode of fixation - single plate or dual plating or nail-plate construct. AO/OTA classification was used for non-periprosthetic, and Unified classification system (UCS) was used for periprosthetic fractures. Data on patient demographics, fracture characteristics, surgical details, postoperative complications, re-operation rate, radiological outcomes and mortality rate were evaluated. Primary objective was to compare re-operation rate and mortality rate between 3 groups at 30 days, 6 months and at 1 year. Results. A cohort of 32 patients with distal femur fractures were included in this study. 91% were females and mean age was 80.97 (range 68–97). 18 (53%) were non-periprosthetic fracture and 14 (47%) were periprosthetic fractures.18 patients underwent single plate fixation (AO/OTA 33A – 8, 33B/C – 2, UCS V3B – 5, V3C – 3),10 patients had dual plate fixation (AO/OTA 33A – 1, 33B/C – 4, UCS V3B – 3, V3C – 2) and 4 patients underwent nail-plate combination fixation (AO/OTA 33A – 4). 70.5% patients had surgery within 36 hours of admission and 90% within 48 hours. Analysis showed no re-operation at 30 days, 6 months in all 3 groups. At 1 year one patient had re-operation in dual-plating periprosthetic group (Distal femur replacement done for failed fixation). Three patients (16%) in single plate group had re-operation at 2 years (2 for
Introduction: Revision surgery for stem loosening and peri-implant bone loss of variable extent is a major challenge for orthopedic surgeons. Our strategy has been to use cementless straight stems of rectangular cross-section for revisions. To ascertain the value of this implant we analyzed the results at a minimum follow-up of 10 years. Material and Method: Between October 1991 and end 1998, 125 patients (134 hips) underwent revision surgery. Of these, 39 were males and 86 were females. Sixty-seven of the original implants were cemented and as many were cementless. Cementless revision stems (SLR; Plus Orthopedics, Aarau, Switzerland) size 3 to 11 (180 to 223 mm in length) were used for revisions. Patient age at the time of surgery was 37.8 to 89.3 (mean, 71.0) years. Fifty patients (53 hips) died post revision 0.0 to 13.5 (mean, 6.8) years. Their implants had been followed-up radiographically for 0.0 to 9.2 (mean, 3.6) years. At the time of revision these patients had been 48.9 to 89.3 (mean, 76.7) years old. One of them had undergone stem revision for aseptic loosening one year post surgery. Another 6 were revised 1.4 to 13.9 years post surgery, 5 for low grade infection and 1 for
The purpose of the following study was to present the general strategy for preserving the lower extremity by knee arthrodesis and to analyze the outcome of knee arthrodeses performed by a special modular system. Between 2009 and 2014 35 knee arthrodeses were performed. 23 patients were male, 12 female. The average age was 66 years (42 to 83 years). The patients underwent an average of 6 operations because of infected knee arthroplasties previous to the knee arthrodesis. The main pathogen was S. epidermidis followed by MRSA. The arthrodeses system included a non cemented femoral and tibial stem (press fit application plus two static locking screws). These were connected by a special stem to stem clamp. Immediate postoperative full weight-bearing was possible in 32 of 35 patients. We saw 4 recurrent infections (all connected to the patients, who did not show a full weight bearing after knee arthrodesis). In two cases re-revision surgery was successful and lead to a sufficient re-arthrodesis. In two cases above-knee-amputation was necessary.
The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability. We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score.Aims
Methods
Introduction and Purpose of Study. Osteogenesis imperfecta (OI) is a bone metabolic disorder that results in multiple fractures and deformities in children. The management of these patients should be in highly specialised units were multi-disciplinary management is mandatory. The aims of this study were twofold: 1. To determine the incidence and pattern of fractures in this population. 2. To determine the type, outcomes and complications of surgical treatment in the same population. Methods. A retrospective audit of patients treated for OI at a tertiary academic Hospital, from January 2002 to December 2011 was done. Results. Fifty three patients with OI were seen in the period under review. The patients came from six South African provinces including two other African countries. The male to female ratio was 1:1. The majority of patients were classified as type III and type IV, 19 (36%) and 14 (26%) respectively. Twelve patients (23%) had a first degree relative with OI. All patients received bisphosphonate therapy intravenously except two who were on oral medication. Seventeen patients (33%) had associated kyphoscoliosis – none were treated surgically. The most common long bone fractures were of the midshaft femur (61 fractures) and tibia (35 fractures). Seventeen patients (32%) received intramedullary rodding of either femur or tibia. Surgery had to be repeated due to rod migration in nine long bones (29%). The most common complication of surgery was rod migration and
Improving periprosthetic bone is essential for implant fixation and reducing
Our primary aim was to assess reoperation-free survival at one year after the index injury in patients aged ≥ 75 years treated with internal fixation (IF) or arthroplasty for undisplaced femoral neck fractures (uFNFs). Secondary outcomes were reoperations and mortality analyzed separately. We retrieved data on all patients aged ≥ 75 years with an uFNF registered in the Swedish Fracture Register from 2011 to 2018. The database was linked to the Swedish Arthroplasty Register and the National Patient Register to obtain information on comorbidity, mortality, and reoperations. Our primary outcome, reoperation, or death at one year was analyzed using restricted mean survival time, which gives the mean time to either event for each group separately.Aims
Methods
Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures.Aims
Methods
Worldwide, total ankle replacement is being more frequently offered as an alternative to ankle fusion. Most reports in the literature come from single centres with surgery performed by ‘high volume’ foot and ankle surgeons. We describe the New Zealand experience with the Scandinavian Total Ankle Replacement (STAR). Fifty-two STARs in 49 patients were implanted between September 1998 and May 2005. Eleven surgeons performed between one and thirteen of the operations. Of the 49 patients five were deceased and five refused to participate in the study. The average age at surgery was 64.9 years (range 46-80). There were 26 males and 13 females. The average follow up was 58.2 months. Of the 41 ankles available for review 11 had been revised or fused (27%) at an average of 42 months post surgery. Of the remaining 30 intact ankles recent radiographs were available on all ankles. Of the retained primary ankles, the mean Oxford ankle score was 25.6. This scale has a range from 12, for an asymptomatic ankle, to 60. The mean WOMAC score was 18.9, the SF-12 PH 42 and the SF-12 MH 54. The scores were substantially worse for the group who had been revised or arthrodesed. Perioperative x-ray findings demonstrated intraoperative malleolar fracture occurred in seven patients including one with a complete saw cut transection of the medial malleolus and one who had sustained fractures of both malleoli. The tibial component was undersised in five patients and the talus oversized in at least three patients. Of the 11 revision cases, two were bearing exchanges only. Nine involved either a major revision procedure or tibiotalocalcaneal arthrodesis for subsidence of malaligned components usually in the presence of
There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation. Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured.Aims
Methods
Introduction: Humeral shaft fractures account for 1–3% of all fractures. Little is known about additional epidemiological data on this specific fracture type. The aim of this study was to investigate the epidemiology of humeral shaft fractures in patients 16 years or older in Stockholm during the years 1998–99. Patients and Methods: All patients 16 years or older with a humeral shaft fracture admitted to any of six major hospitals in the County of Stockholm during the two years 1998–99 were included in the study. A total of 401 fractures in 397 patients were found. Three hundred and sixty-one of the fractures were traumatic and were classified according to the Orthopaedic Trauma Association (OTA) classification system. The remaining 40 fractures were pathological (n=34) or