Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 17 - 17
1 Mar 2013
Mostert P Snyckers C
Full Access

Purpose of the study

Percutanous acetabular surgery is a new and developing technique in fixation of acetabulum fractures. The most common screw used is the anterior column screw that traverses anterograde or retrograde through the anterior column of the acetabulum. Standard height and width calculations derived from CT scans do not take the trajectory of the screw into consideration. They have been shown to exaggerate the available safe bone corridor for screw passage. Posterior column screws can be placed in a retrograde fashion via the ischial tuberosity to fixate posterior column. Limited international data is available and no studies to date have been conducted on the South African population. This study assesses the anterior and posterior acetabular columns of South African individuals and ascertains the safe bone corridor sizes.

Methods

Pelvic CT-scans of 100 randomly selected patients were reviewed. Specific computer software was used to virtually place anterior screws through the anterior acetabular column, in its clinical trajectory. Specific entry points inferior to the pubic tubercles significantly changed the relation of the screw trajectory to the mid- column isthmus and were incorporated in the measurement of the anterior column. All the available lengths and diameters were measured and averages were calculated for males and females.


Full Access

Hallux valgus surgery can result in moderate to severe post-operative pain requiring the use of narcotic medication. The percutaneous distal metatarsal osteotomy is a minimally invasive approach which offers many advantages including minimal scarring, immediate weight bearing and decreased post-operative pain. The goal of this study is to determine whether the use of narcotics can be eliminated using an approach combining multimodal analgesia, ankle block anesthesia and a minimally invasive surgical approach. Following ethics board approval, a total of 160 ambulatory patients between the ages of 18-70 with BMI ≤ 40 undergoing percutaneous hallux valgus surgery are to be recruited and randomized into Narcotic-free (NF) or Standard (S) groups. To date, 72 patients have been recruited (38 NF and 34 S). The NF group received acetaminophen, naproxen, pregabalin 75mg and 100mg Ralivia (tramadol extended release) before surgery and acetaminophen, naproxen, pregabalin 150mg one dose and Ralivia 100mg BID for five days, as well as a rescue narcotic (hydromorphone, 1mg pills) after surgery. The S group received acetaminophen and naproxen prior to surgery and acetaminophen, naproxen and hydromorphone (1mg pills) post-operatively, our current standard. Visual analog scales (VAS) were used to assess pain and narcotic consumption was recorded at 6, 12, 24, 36, 48, 72 hours and seven days post-operatively. Patients wore a smart watch to record the number of daily steps and sleep hours. A two-sided t-test was used to compare the VAS scores and narcotic consumption. During the first post-operative week, the NF group consumed in total an average of 6.5 pills while the S group consumed in total an average of 16 pills and this difference was statistically significant (p-value=0.001). Importantly, 19 patients (50%) in the NF group and four patients (12%) in the S group did not consume any narcotics post-operatively. For the VAS scores at 24, 48, 72 hours and seven days the NF group's average scores were 2.17, 3.17, 2.92, 2.06 respectively and the S group's average scores were 3.97, 4.2, 3.23, 1.97. There was a statistically significant difference between the groups at 24 and 48hours (the NF group scored lower on the VAS) with a p-value of 0.0008 and 0.04 respectively, but this difference is not considered clinically significant as the minimal clinically important difference reported in the literature is a two-point differential. The NF group walked an average of 1985.75 steps/day and slept an average of 8h01 minute/night, while the S group walked an average of 1898.26 steps/day and slept an average of 8h26 minutes/night in the first post-operative week. Hallux valgus remains a common orthopedic foot problem for which surgical treatment results in moderate to severe post-operative pain. This study demonstrates that with the use of multimodal analgesia, ultrasound guided ankle blocks and a percutaneous surgical technique, narcotic requirements decreased post-operatively. The use of long-acting tramadol further decreased the need for narcotic consumption. Despite decreased use of narcotics, this combined novel approach to hallux valgus surgery allows for early mobilization and excellent pain control


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 47 - 47
1 Oct 2014
Ruatti S Merloz P Moreau-Gaudry A Chipon E Dubois C Tonetti J Milaire M Kerschbaumer G
Full Access

In recent years internal fixation of the spine by using posterior approach with minimally invasive and percutaneous technique were increasingly used in trauma. The percutaneous surgery lose information and navigation is supposed to provide better data because the lost information is found again. We hypothesise that a percutaneous minimal invasive dorsal procedure by using 3D intra-operative imaging for vertebral fractures allows short operating times with correct screw positioning and does not increase radiation exposure. 59 patients were included in this prospective, monocentric and randomised study. 29 patients (108 implants) were operated on by using conventional surgical procedure (CP) and 30 patients (72 implants) were operated on by using a 3D fluoroscopy-based navigation system (3D fluo). In the two groups, a percutaneous approach was performed for transpedicular vertebroplasty or percutaneous pedicle screws insertion. In the two groups surgery was done from T4 level to L5 levels. Patients (54 years old on average) suffered trauma fractures, fragility fractures or degenerative instabilities. Evaluation of screw placement was done by using post-operative CT with two independent radiologists that used Youkilis criteria. Operative and radiation running time were also evaluated. With percutaneous surgery, the 3D fluo technique was less accurate with 13.88% of misplaced pedicle screws (10/72) compared with 11.11% (12/108) observed with CP. The radiation running time for each vertebra level (two screws) reached on average 0.56 mSv with 3D fluo group compared to 1.57 mSv with the CP group. The time required for instrumentation (one vertebra, two screws) with 3D fluo was 19.75 minutes compared with CP group 9.19 minutes. The results were statistically significant in terms of radiation dose and operative running time (p < 0.05), but not in terms of accuracy (p= 0.24). With percutaneous procedures, 3D fluoroscopy-based navigation (3D fluo) system has no superiority in terms of operative running time and to a lesser degree in terms of accuracy, as compared to 2D conventional procedure (CP), but the benefit in terms of radiation dose is important. Other advantages of the 3D fluo system are twofold: up-to-date image data of patient anatomy and immediate availability to assess the anatomical position of the implanted screws


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 11 - 11
1 Feb 2016
Merloz P Ruatti S Dubois C Chipon E Kerschbaumer G Milaire M Moreau-Gaudry A Tonetti J Dao Lena S
Full Access

Introduction. We report a single-centre, prospective, randomised study for pedicle screw insertion, by using a Computer Assisted Surgery (CAS) technique with three dimension (3D) intra-operative images intensifier versus conventional surgical procedure. Methods. 143 patients (68 women and 75 men) were included in this study. 72 patients underwent conventional surgery (C = conventional). 71 patients were operated on with the help of a 3D intra-operative imaging system (N = navigated). We performed 34 percutaneous surgeries in group N and 37 in group C; 25 open surgeries in group N and 35 in group C. 382 screws were implanted in group C and 174 in group N. We measured the pedicle screw running-time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary's classification by two independent radiologists on a post-operative CT. Results. 3D Fluoro-navigation appeared less accurate with percutaneous procedures (24% of misplaced pedicle screws versus 5% in Group C) (p=0,007), but more accurate in opened surgeries (5% of misplaced pedicle screws versus 17% in Group C) (p=0,025). In this study, 3D-fluoroscopy navigation increases the instrumentation time, with a strongly higher radiation rate. Conclusion. Therefore, our work hypotheses are partially confirmed according to the type of analysed criteria