Introduction. To introduce a new classification method and analyze related risk factor about lateral wall perforation associated with lower cervical
Introduction. Correction and arthrodesis for cervical kyphosis associated with atetoid cerebral palsy has been considered to be difficult because of their involuntary neck movements and severe deformity. The aim of this study is to evaluate the surgical outcome of midline T-saw laminoplasty and posterior arthrodesis using
Introduction. A new triggered electromyography test for detection of stimulus diffusion to intercostal muscles of the contralateral side during thoracic
Lowest instrumented vertebra (LIV) selection is critical to preventing complications following posterior spinal arthrodesis (PSA) for thoracolumbar/lumbar adolescent idiopathic scoliosis (TL/L AIS), but evidence guiding LIV selection is limited. This study aimed to investigate the efficacy of PSA using novel unilateral convex segmental
Introduction. Short-segment posterior instrumentation for spine fractures is threatened by unacceptable failure rates. Two important design objectives of
Introduction.
Simulation in surgical training has become a key component of surgical training curricula, mandated by the GMC, however commercial tools are often expensive. As training budgets become increasingly pressurised, low-cost innovative simulation tools become desirable. We present the results of a low-cost, high-fidelity simulator developed in-house for teaching fluoroscopic guidewire insertion. A guidewire is placed in a 3d-printed plastic bone using simulated fluoroscopy. Custom software enables two inexpensive web cameras and an infra-red led marker to function as an accurate computer navigation system. This enables high quality simulated fluoroscopic images to be generated from the original CT scan from which the bone model is derived and measured guidewire position. Data including time taken, number of simulated radiographs required and final measurements such as tip apex distance (TAD) are collected. The simulator was validated using a DHS model and integrated assessment tool. TAD improved from 16.8mm to 6.6mm (p=0.001, n=9) in inexperienced trainees, and time taken from 4:25s to 2m59s (p=0.011). A control group of experienced surgeons showed no improvement but better starting points in TAD, time taken and number of radiographs. We have also simulated cannulated hip screws, femoral nail entry point and SUFE, but the system has potential for simulating any procedure requiring fluoroscopic guidewire placement e.g.
Study Design. Retrospective review. Objective. To report the technique and results of vertebral column decancellation (VCD) for the management of sharp angular spinal deformity. Summary of Background Data. The goal of management of sharp angular spinal deformity is to realign the spinal deformity and safely decompress the neurological elements. However, some shortcomings related to current osteotomy treatment for these deformities are still evident. Methods. From January 2004 to March 2007, 45 patients (27 males/18 females) with severe sharp angular spinal deformities at our institution underwent VCD. The diagnoses included 29 congenital kyphoscoliosis and 16 Pott's deformity. The operative technique included multilevel VCD, disc removal, osteoclasis of the concave cortex, compression of the convex cortex accompanied by posterior instrumentation with
INTRODUCTION. Surgical correction of spinal deformities in the growing child can be applied with or without fusion. Sublaminar wiring, first described by Luque, allows continuation of growth of the non-fused spine after correction of the deformity. Neurological complications and wire breakage are the main clinical problems during the introduction and removal of currently used sublaminar wires. In this pilot study a posterior hybrid construction with the use of a medical-grade UHMWPE (Dyneema Purity®) sublaminar wire was assessed in an ovine model. We hypothesized that such a hybrid construction can safely replace current titanium laminar wires, while providing sufficient stability of the non-fused spinal column with preservation of growth. MATERIALS AND METHODS. This study included 6 Tesselaar sheep, age 7±2months. Two
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods
We compared the accuracy, operating time and radiation exposure
of the introduction of iliosacral screws using O-arm/Stealth Navigation
and standard fluoroscopy. Iliosacral screws were introduced percutaneously into the first
sacral body (S1) of ten human cadavers, four men and six women.
The mean age was 77 years (58 to 85). Screws were introduced using
a standard technique into the left side of S1 using C-Arm fluoroscopy
and then into the right side using O-Arm/Stealth Navigation. The
radiation was measured on the surgeon by dosimeters placed under
a lead thyroid shield and apron, on a finger, a hat and on the cadavers.Aims
Materials and Methods
The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery. A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.Objectives
Methods
The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.
We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.