Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 4 - 4
11 Apr 2023
Lynch J Perriman D Scarvell J Pickering M Galvin C Smith P
Full Access

Total knee replacement (TKR) design aims to restore normal kinematics with emphasis on flexion range. The survivorship of a TKR is dependent on the kinematics in six-degrees-of-freedom (6-DoF). Stepping up, such as stair ascent is a kinematically demanding activity after TKR. The debate about design choice has not yet been informed by 6-DoF in vivo kinematics. This prospective randomised controlled trial (RCT) compared kneeling kinematics in three TKR designs. 68 participants were randomised to receive either cruciate retaining (CR-FB), rotating platform (CR-RP) or posterior stabilised (PS-FB) prostheses. Image quality was sufficient for 49 of these patients to be included in the final analysis following a minimum 1-year follow-up. Patients completed a step-up task while being imaged using single-plane fluoroscopy. Femoral and tibial computer-aided design (CAD) models for each of the TKR designs were registered to the fluoroscopic images using bespoke software OrthoVis to generate six-degree-of-freedom kinematics. Differences in kinematics between designs were compared as a function of flexion. There were no differences in terminal extension between the groups. The CR-FB was further posterior and the CR-RP was more externally rotated at terminal extension compared to the other designs. Furthermore, the CR-FB designs was more posteriorly positioned at each flexion angle compared to both other designs. Additionally, the CR-RP design had more external femoral rotation throughout flexion when compared with both fixed bearing designs. However, there were no differences in total rotation for either step-up or down. Visually, it appears there was substantial variability between participants in each group, indicating unique patient-specific movement patterns. While use of a specific implant design does influence some kinematic parameters, the overall patterns are similar. Furthermore, there is high variability indicating patient-specific kinematic patterns. At a group level, none of these designs appear to provide markedly different step-up kinematic patterns. This is important for patient expectations following surgery. Future work should aim to better understand the unique patient variability


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 5 - 5
1 Mar 2021
Kumar G Debuka E
Full Access

Increasing incidence of osteoporosis, obesity and an aging population have led to an increase in low energy hip fractures in the elderly. Perceived lower blood loss and lower surgical time, media coverage of minimal invasive surgery and patient expectations unsurprisingly have led to a trend towards intramedullary devices for fixation of extracapsular hip fractures. This is contrary to the Cochrane review of random controlled trials of intramedullary vs extramedullary implants which continues recommends the use of a sliding hip screw (SHS) over other devices. Furthermore, despite published literature of minimally invasive surgery (MIS) of SHS citing benefits such as reduced soft tissue trauma, smaller scar, faster recovery, reduced blood loss, reduced analgesia needs; the uptake of these approaches has been poor. We describe a novel technique one which remains minimally invasive, that not only has a simple learning curve but easily reproducible results. All patients who underwent MIS SHS fixation of extracapsular fractures were included in this study. Technique is shown in Figure 1. We collated data on all intertrochanteric hip fractures that were treated by a single surgeon series during period Jan 2014 to July 2015. Data was collected from electronic patient records and radiographs from Picture Archiving and Communication System (PACS). Surgical time, fluoroscopy time, blood loss, surgical incision length, post-operative transfusion, Tip Apex Distance (TAD) were analyzed. There were 10 patients in this study. All fractures were Orthopaedic Trauma Association (OTA) type A1 or A2. Median surgical time was 36 minutes (25–54). Mean fluoroscopy time was similar to standard incision sliding hip screw fixation. Blood loss estimation with MIS SHS can be undertaken safely and expeditiously for extracapsular hip fractures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 115 - 115
1 Nov 2018
Beaulé P
Full Access

Total hip arthroplasty (THA) is one of the most successful surgery. However, patients' expectations have increased over the last two decades in regards to hip function after joint replacement, the patients assume to return their daily and sport activities without major limitations. This presentation will examine the effect of surgical approaches and implant designs as well as rehabilitation protocol on the clinical and biomechanical outcomes after THA. The new implant designs for THA aim to improve joint function whereas the surgical approaches intend to reduce muscle damage to regain muscle strength. One important determinant measured from gait analysis is the hip abduction moment as the abductors play a key role in stabilizing the pelvis in the frontal plane, particularly in phases of transition, such as the single leg stance in walking or stair climbing. This showed that muscle strength needs to be preserved. To minimize the risk of hip joint instability, a strong focus of implant development has been carried out. To illustrate this important concept within the context of gait analysis, I will present two studies that examine the influence of surgical approach and biomechanical reconstruction; and the second, is a prospective RCT comparing a dual mobility implant to a standard total hip replacement


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 156 - 156
1 Jul 2014
Fitzgerald L Titchener A Miles A
Full Access

Summary Statement. The tensile properties of a number of synthetic fibre constructs and porcine MCLs were experimentally determined and compared to allow the selection of an appropriate synthetic collateral ligament model for use in a kinematic knee simulator. Introduction. As patient expectations regarding functional outcomes of total knee arthroplasty rise the need to assess the kinematics of new implants in vitro has increased. This has traditionally been done using cadaveric models, which can demonstrate high physiological relevance but also substantial inter-specimen variability. More recently there has been a shift towards the use of in silico and non-cadaveric methods. Such methods require significant simplifications of the joint and the modelling of soft tissue structures such as the collateral ligaments. Collateral ligaments are often modelled in in silico studies but have not, in the published literature, been modelled in in vitro knee kinematic simulators. Tensile testing of ligament tissue, to provide reference data, and the subsequent analysis of potential synthetic analogues was carried out. The overall aim of the study was to develop a synthetic ligament analogue for use in kinematic knee simulators. Methods. Porcine MCLs were chosen as these are of a similar size and are a readily available alternative to human ligaments. Six porcine knee specimens were sourced and the MCLs dissected by an orthopaedic registrar. Testing was carried out on an Instron MTS fitted with a 5kN load cell. Each specimen was subjected to 5 pre-conditioning loading cycles before cross-sectional and length measurements were made. Each specimen was then cyclically loaded from 0–200N for 30 cycles before being loaded to failure at a rate of 100mm/min. Ten potential synthetic analogues were also assessed using the same procedure: the Lars 80 (Corin Ltd) synthetic ligament reconstruction system and a selection of readily available synthetic constructs. Results. The porcine specimens demonstrated 6% ± 1% strain (mean ± standard error) after 30 cycles of loading, and a tensile stiffness of 100 N/mm ± 8.9 N/mm. The results of the load to failure tests also indicated a substantial toe region and highlighted the substantial variability associated with cadaveric specimens. The Lars system demonstrated a tensile stiffness of nearly 9 times that of the porcine specimens. However, non-parametric Mann-Whitney U analyses indicated that three of the synthetic samples did not have statistically significantly different tensile stiffness values compared to the porcine specimens (p < 0.05). Of these samples, the polyester braided cord demonstrated the longest and most physiologically relevant toe region. All of the polyester load-displacement traces fell within the range demonstrated by the porcine specimens. Discussion/Conclusion. The tensile properties of the porcine specimens analysed were similar to those reported in in the literature for human ligaments1. Porcine MCLs are thus a fair model of human collateral ligaments and were a suitable reference material for the selection of a synthetic analogue. The tensile testing carried out in the present study indicated that commercially available synthetic ligaments are over engineered in terms of strength and inappropriate for use in kinematic analysis. However, a polyester braided cord did demonstrate appropriate basic mechanical properties and would be appropriate as an analogue model on kinematic knee rigs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 6 - 6
1 Aug 2013
Boyd A Soon V Sapare S McAllister J Deakin A Sarungi M
Full Access

Patient reported outcome measures (PROMs) are important for assessing the results of lower limb arthroplasty. Unrealistic or uneducated expectations may have a significant negative impact on PROMs even when surgery is technically successful. This study's aim was to quantify pre-operative expectations of Scottish patients undergoing total hip and knee replacement (THR/TKR). 100 THR and 100 TKR patients completed validated questionnaires (from the Hospital for Special Surgery) prior to their operation after receiving standard pre-operative information (booklet, DVD, consultations). Each patient rated expectations from very important to not having the expectation. A total score was calculated using a numerical scale for the grading of each expectation. Univariate regression analysis was used to investigate the relationship between demographics and expectation score. The THR cohort had mean age 66.2 (SD 10.5), 53% female, mean BMI 29.0 (SD 5.1) and mean Oxford score 44 (SD 7). The TKR cohort had mean age 67.6 (SD 8.5), 59% female, mean BMI 32.8 (SD 5.8) and mean Oxford score 44 (SD 8). 100% THR and 96% TKR patients had 10 or more expectations of their operation. All expected pain relief. Other improvements expected were: walking for 100% THA and 99% TKA patients; daily activities for 100% THAs and 96% TKAs; recreational activities for 96% THAs and 93% TKAs; sexual activity for 66% THAs and 59% TKAs; psychological well-being for 98% THAs and 91% TKAs. Regression analysis showed increasing age lowered expectations in both THR (p=0.025) and TKR (p=0.031) patients but that gender, BMI and Oxford score were not significantly related to expectations. This study highlights that patients expect far more than pain relief and improved post-operative mobility from their operation. It is important to discuss and manage these expectations with patients prior to surgery. By doing so, patient satisfaction and PROMs should further improve