Abstract. Optical motion capture (OMC) is the current gold standard for motion analysis, however measuring
The biomechanics of the patellofemoral joint can become disturbed during total knee replacement by alterations induced by the position and shape of the different prosthetic components. The role of the patella and femoral trochlea has been well studied. We have examined the effect of anterior or posterior positioning of the tibial component on the mechanisms of
Malrotation of the femoral component is a cause of
Introduction. The medial patellofemoral ligament (MPFL) is the main stabilizer of the patella and therefore mostly reconstructed in the surgical correction of
Summary Statement. This project proves that
Using a new, non-invasive method, we measured the
Patellofemoral osteoarthritis (PFOA) affects 32% men and 36% women over the age of 60years and is associated with anterior knee pain, stiffness, and poor mobility. Patellofemoral arthroplasty (PFA) is a bone-sparing treatment for isolated PFOA. This study set out to investigate the relationship between patient-related outcome measures (PROMs) and measurements obtained from gait analysis before and after PFA. There are currently no studies relating to gait analysis and PFA available in the literature A prospective cohort study was conducted of ten patients known to have isolated PFOA who had undergone PFA compared to a gender and age matched control group. The patients were also asked to complete questionnaires (Oxford knee score (OKS), EQ-5D-5L) before surgery and one year after surgery. Gait analysis was done on an instrumented treadmill comparing Ground reaction force parameters between the control and pre and post-operative PFA patients The average age 60 (49–69) years with a female to male ratio of 9:1. Patient and healthy subjects were matched for age and gender, with no significant difference in BMI. Post-op PFA improvement in gait seen in ground reaction force at 6.5km/h. Base support difference was statistically significant both on the flat P=0.0001 and uphill P=0.429 (5% inclination) and P=0.0062 (10% inclination). PROMS response rate was 70%(7/10) pre-operative and 60%(6/10) post-operative. EQ-5D-5L scores reflected patient health state was better post-operatively. This study found that gait analysis provides an objective measure of functional gait and reflected by significant quality-of-life improvement of patients post PFA. Literature lacks studies relating to gait-analysis and PFA. Valuable information provided by this study highlights that PFA has a beneficial outcome reflected by PROMs and improvement in vertical ground reaction force and gait Further research is needed to assess how care-providers may use gait-analysis as part of patient care plans for PFOA patients.
Introduction and Objective. TKA have shown both excellent long-term survival rate and symptoms and knee function improvement. Despite the good results, the literature reports dissatisfaction rates around 20%. This rate of dissatisfaction could be due to the overstuff that mechanically aligned prostheses could produce during the range of motion. Either size discrepancy between bone resection and prosthetic component and constitutional mechanical tibiofemoral alignment (MTFA) alteration might increase soft tissue tension within the joint, inducing pain and functional limitation. Materials and Methods. Total knee arthroplasties performed between July 2019 and September 2020 were examined and then divided into two groups based on the presence (Group A) or absence (Group B) of
Abstract. Objectives. There is renewed interest in bi-unicondylar arthroplasty (Bi-UKA) for patients with medial and lateral tibiofemoral osteoarthritis, but a spared
Abstract. Background. Recurrent patellar dislocation in combination with cartilage injures are difficult injuries to treat with confounding pathways of treatment. The aim of this study is to compare the clinical and functional outcomes of patients operated for patellofemoral instability with and without cartilage defects. Methods. 82 patients (mean age-28.8 years) with recurrent patellar dislocations, who underwent soft-tissue or bony procedures, were divided into 2 matched groups (age, sex, follow-up and type of procedure) of 41 each based on the presence or absence of cartilage defects in patella. Chondroplasty, microfracture, osteochondral fixation or AMIC-type procedures were done depending on the nature of cartilage injury. Lysholm, Kujala, Tegner and Subjective Knee scores of both groups were compared and analysed. Complications and return to theatre were noted. Results. With a mean follow-up of 8 years (2 years-12.3 years), there was a significant improvement observed in all the mean post-operative Patient Reported Outcome Measures (p<0.05) of both the groups, as compared to the pre-operative scores. Comparing the 2 groups, post-operative Lysholm, Kujala and Subjective knee scores were significantly higher in patients operated without cartilage defects (p<0.05). 3 patients operated for PFJ instability with cartilage defects had to undergo
Abstract. Objectives. Patella resurfacing in primary total knee arthroplasty (TKA) remains a contentious issue. Australian rates of patellar resurfacing are 66.6%, significantly higher compared to UK rates of 8–15% and Swedish rates of 2%. Resurfacing has gained popularity in Australia since registry data has shown decreased revision rates with no increase in patellar component related complications. We present for discussion an analysis of 113,694 total knee arthroplasties using commonly implanted prostheses in the UK. Methods. We included all TKA's since the Australian register's conception on 01/09/1999 for a primary diagnosis of osteoarthritis involving the use of either the Triathlon or Duracon implant with and without patellar components. The primary outcome of the study was time to revision for Triathlon's resurfaced and non-resurfaced prosthesis compared to the Duracon's equivalent data. We also analysed the reasons for revision between the 4 groups, type of revision and complication rates. We then compared minimally stabilised and posterior stabilised prostheses. Results. The cumulative revision rate for Triathlon prostheses with resurfacing after 12 years was 3.2% (95% CI, 2.9% to 3.6%) compared to 5.6% (95% CI, 5.0% to 6.2%) without resurfacing. Duracon's equivalent data was 6.3% with resurfacing and 5.9% without resurfacing. Triathlon prosthesis with resurfacing have much lower rates of revision due to loosening, patellofemoral pain, patellar erosion compared to unresurfaced Triathlon prostheses. Conclusion. Triathlon with re-surfacing has lower revision rates regardless of age or BMI. Previous concerns regarding
Background. Recurrent patellar dislocation in combination with cartilage injures are difficult injuries to treat with confounding pathways of treatment. The aim of this study is to compare the clinical and functional outcomes of patients operated for patellofemoral instability with and without cartilage defects. Methods. 82 patients (mean age-28.8 years) with recurrent patellar dislocations, who underwent soft-tissue or bony procedures, were divided into 2 matched groups (age, sex, follow-up and type of procedure) of 41 each based on the presence or absence of cartilage defects in patella. Chondroplasty, microfracture, osteochondral fixation or Autologous Matrix-Induced Chondrogenesis(AMIC)-type procedures were done depending on the nature of cartilage injury. Lysholm, Kujala, Tegner and Subjective Knee scores of both groups were compared and analysed. Complications and return to theatre were noted. Results. With a mean follow-up of 8 years (2 years-12.3 years), there was a significant improvement observed in all the mean post-operative Patient Reported Outcome Measures (p<0.05) of both the groups, as compared to the pre-operative scores. Comparing the 2 groups, post-operative Lysholm, Kujala and Subjective knee scores were significantly higher in patients operated without cartilage defects (p<0.05). 3 patients operated for patellofemoral instability with cartilage defects had to undergo
Abstract. Objectives. The need for gender specific knee arthroplasty is debated. This research aimed to establish whether gender differences in patellar tendon moment arm (PTMA), a composite measure that characterises function of both the
The Medial Patellofemoral Ligament (MPFL) is the main restraining force against lateral patellar displacement. It is often disrupted following patellar subluxation or dislocation. MPFL reconstruction is frequently performed when conservative management fails and the patient experiences recurrent patellar dislocation. Various MPFL reconstruction procedures have been described in the literature and reported outcomes are encouraging. This study analyses the radiographic outcomes following MPFL reconstruction. From January 2006 to January 2011, 76 consecutive patients (80 knees) with patellar recurrent dislocation underwent medial patellofemoral ligament reconstruction in three large teaching hospitals. Mean follow-up was 31.8 months (range, 13–72). Semitendinosus and gracilis autografts were used for the reconstruction and all procedures were carried out by the senior authors (WL, BR, CW, MB). Plain radiographs (Anteroposterior (AP), Lateral and Skyline) performed preoperatively and postoperatively were used to compare the sulcus angle, congruence angle, lateral
Introduction. Management of the
Background. Biomechanical joint contact pressure distribution measurements have proven to be a very valuable tool in orthopaedic research to investigate the influence of surgical techniques such as total knee arthroplasty (TKA) on the human knee joint. Quantification of the in vitro tibiofemoral and
Distal femur resection for correction of flexion contractures in total knee arthroplasty (TKA) can lead to joint line elevation, abnormal knee kinematics and
Summary Statement. Computational models are the primary tools for efficient design-phase exploration of knee replacement concepts before in vitro testing. To improve design-phase efficiency, a subject-specific computational platform was developed that allows designers to assess devices in realistic conditions by directly integrating subject-specific experimental data in these models. Introduction. Early in the design-phase of new implant design, numerous in vitro tests would be desirable to assess the influence of design parameters or component alignment on the performance of the device. However, cadaveric testing of knee replacement devices is a costly and time-consuming procedure, requiring manufacture of parts, preparation of cadaveric specimens, and personnel to carry of the experiments. Validated computational models are ideally suited for pre-clinical, high-volume design evaluation. Initial development of these models requires substantial time and expertise; once developed, however, computational simulations may be applied for comparative evaluation of devices in an extremely efficient manner [Baldwin et al. 2012]. Still, computational models are complementary of experimental testing and for this reason, computational models tuned with subject-specific experimental data, e.g. soft tissue parameters, could bring even more efficiency in the design phase. The objective of the current study was to develop a platform of tools that easily allows for subject-specific knee simulations. The system integrates with commercially available medical imaging and finite element software to allow for direct, efficient comparison of designs and surgical alignment under a host of different boundary conditions. Patients & Methods. MRI image was acquired, and 3D bone models were generated using the Mimics Innovation Suite® (Materialise NV, Leuven, Belgium). The two models (1) tibiofemoral (TF) joint laxity including ligamentous constraint and (2) whole joint (TF and
Summary Statement. A large proportion of knee arthroplasty patients are dissatisfied with their replacement. Significant differences exist between preoperative, postoperative and normal kinematics. A better understanding of the inter-relationships between kinematics, shape and prosthesis placement could lead to improved quality of life. Introduction. Knee kinematics are altered by total knee arthroplasty (TKA) both intentionally and unintentionally. Knowledge of how and why kinematics change may improve patient outcome and satisfaction through improved implant design, implant placement or rehabilitation. Comparing preoperative to postoperative kinematics and shape of the natural and replaced joint will allow an investigation of the inter-relationships between knee shape, prosthesis placement, knee kinematics and quality of life. Patients & Methods. Using a sequential-biplanar radiographic protocol that allowed imaging the preoperative and postoperative
Summary. Both endogenous lubricin and injectable hyaluronic acid reduced cartilage friction coefficients, but by distinct mechanisms. Lubricin operated in boundary mode and hyaluronic acid shifted lubrication to mixed or hydrodynamic mode. Introduction. Intra-articular injections of viscous agents and boundary lubricants have been presented as options to mitigate the progression of articular cartilage damage after the onset of osteoarthritis. 1,2. Mechanically, these injections are predicted to lower the friction coefficient within a load bearing joint and consequently slow the propagation of damage at the articular surface. Tribologically, boundary lubricants and viscous agents are hypothesised to be effective through different mechanisms affecting boundary-mode lubrication and transition to mixed-mode lubrication, respectively. By normalizing sliding speeds on a Stribeck curve, this study evaluated the efficacy of injectable hyaluronic acid (HA) supplements and endogenous lubricin to alter tribological properties. Methods. Cartilage samples were extracted from the