Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 64 - 64
1 Nov 2018
Karakasli A
Full Access

Transverse patella fractures are commonly encountered in trauma surgery, open reduction and internal fixation are considered the gold standard treatment modality that could permit early knee motion and immediate rehabilitation. Many fixation methods had been defined and compared to each other's in many clinical and biomechanical studies. The aim of this study was to assess the safety and stability of our novel anatomical patella plate and to compare its stability with tension band-wire technique. A total of 12 cadaveric preserved knees (six right and six left patellae) with close patellar size were chosen to form two groups of six samples. Each group received either plate or tension band-wiring fixation for an experimentally created patella fracture. Cyclic load of an average of 350 N was applied for all specimens and after accomplishing 50 cycles the displacements of all fracture edges were recorded. After completing 50 cycles in each group, the average fracture edges displacement measured in the plate group was 1.98 ± 0.299 mm, whereas the average fracture edges displacement measured in the tension band-wire group was 2.85 ± 0.768 mm (p = 0.016). In the operative treatment of displaced transverse patellar fractures, the strength of fixation obtained by titanium curved plates is highly stronger when compared to the fixation with a tension band-wire technique. Fixation with titanium curved plates provides satisfactory stability at the fracture site which allow withstanding the cyclic loads during the postoperative rehabilitation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 23 - 23
4 Apr 2023
Stoffel K Zderic I Pastor T Woodburn W Castle R Penman J Saura-Sanchez E Gueorguiev B Sommer C
Full Access

Treatment of simple and complex patella fractures represents a challenging clinical problem. Controversy exists regarding the most appropriate fixation method. Tension band wiring, aiming to convert the pulling forces on the anterior aspect of the patella into compression forces across the fracture site, is the standard of care, however, it is associated with high complication rates. Recently, anterior variable-angle locking plates have been developed for treatment of simple and comminuted patella fractures. The aim of this study was to investigate the biomechanical performance of the novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Sixteen pairs of human cadaveric knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or an anterior variable-angle locking core plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or an anterior variable-angle locking three-hole plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range from 90° flexion to full knee extension. Interfragmentary movements were captured by motion tracking. For both fracture types, the articular displacements, measured between the proximal and distal fragments at the central aspect of the patella between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the anterior variable-angle locked plating compared with the tension band wiring, p < 0.01. From a biomechanical perspective, anterior locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 56 - 56
2 Jan 2024
Zderic I Warner S Stoffel K Woodburn W Castle R Penman J Saura-Sanchez E Helfet D Gueorguiev B Sommer C
Full Access

Treatment of both simple and complex patella fractures is a challenging clinical problem. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Twelve pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34C1 or five-part complex AO/OTA 34C3 patella fractures by means of osteotomies, with each fracture model created in six pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full knee extension. Interfragmentary movements were captured via motion tracking. For both fracture types, the longitudinal and shear articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p<0.01. Lateral rim locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 29 - 29
17 Nov 2023
Morris T Dixon J Baldock T Eardley W
Full Access

Abstract. Objectives. The outcomes from patella fracture have remained dissatisfactory despite advances in treatment, especially from operative fixation1. Frequently, reoperation is required following open reduction and internal fixation (ORIF) of the patella due to prominent hardware since the standard technique for patella ORIF is tension band wiring (TBW) which inevitably leaves a bulky knot and irritates soft tissue given the patella's superficial position2. We performed a systematic review to determine the optimal treatment of patella fractures in the poor host. Methods. Three databases (EMBASE/Medline, ProQuest and PubMed) and one register (Cochrane CENTRAL) were searched. 476 records were identified and duplicates removed. 88 records progressed to abstract screening and 73 were excluded. Following review of complete references, 8 studies were deemed eligible. Results. Complication rates were shown to be high in our systematic review. Over one-fifth of patients require re-operation, predominantly for removal of symptomatic for failed hardware. Average infection rate was 11.95% which is higher than rates reported in the literature for better hosts. Nevertheless, reported mortality was low at 0.8% and thromboembolic events only occurred in 2% of patients. Average range of movement achieved following operative fixation was approximately 124 degrees. Upon further literature review, novel non-operative treatment options have shown acceptable results in low-demand patients, including abandoning weight-bearing restrictions altogether and non-operatively treating patients with fracture gaps greater than 1cm. Regarding operative management, suture/cable TBW has been investigated as a viable option with good results in recent years since the materials used show comparable biomechanics to stainless steel. Additionally, ORIF with locking plates have shown favourable results and have enabled aggressive post-operative rehabilitation protocols. TBW with metallic implants has shown higher complication rates, especially for anterior knee pain, reoperation and poor functional outcomes. Conclusion. There is sparse literature regarding patella fracture in the poor host. Nevertheless, it is clear that ORIF produces better outcomes than conservative treatment but the optimal technique for patella ORIF remains unclear. TBW with metallic implants should not remain the standard technique for ORIF; low-profile plates of suture TBW are more attractive solutions. Non-operative treatment may be considered for low-demand individuals however any form of patellectomy should be avoided if possible. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 6 - 6
1 Apr 2015
Hatab S Tanagho A Ansara S
Full Access

The patella is an important component of the extensor mechanism of the knee. Patellar fractures need to be fixed if displacement occurs more than 2 mm. Transverse fractures comprise the largest category. Several different techniques for internal fixation have been employed. The aim of this work was to evaluate the results of treatment of transverse patellar fractures with figure of eight wiring through cannulated screws. Twenty patients were included in the study, all suffering from displaced transverse patellar fractures. All were treated by open reduction and internal fixation with figure of eight tension band wire through 4.0 mm cannulated screws. All patients were assessed after 1 month, 3 months and 6 months according to a modified Hospital for special surgery (HSS) knee scoring system. Because varus and valgus knee alignment and stability are not affected by patellar fracture fixation, the ten points assigned to these functions are eliminated, making the highest score ninety points. Excellent results are considered with points from 75 to 90, good from 60 to 74, fair from 50 to 59 and poor with points below 50. The final results of the study showed fourteen patients (70%) had excellent results, five (25%) good result, one (5%) fair result and no patient had a poor result. There was a statistically significant improvement of the patients' score throughout the follow up period. The complications occurred included knee pain in one patient (5%), loss of terminal flexion of knee occurred in three patients (15%), one patient lost 30 degrees, another lost 20 degrees while the last lost 10 degrees. There were no cases with extension lag in this series. Treatment of patellar fractures using figure of eight wiring through cannulated screws is an easy technique which gives good stability leading to good results with a low complication rate


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 34 - 34
1 Mar 2012
Hasegawa M Kawamura G Wakabayashi H Sudo A Uchida A
Full Access

Introduction. Standard surgical exposure reduces blood flow to the patella during total knee arthroplasty (TKA). Reduction of patellar blood flow has resulted in patellofemoral complications including osteonecrosis and patellar fracture, necessitating revision surgery. Eversion of the patella is typically used to gain access to the knee joint in most TKA surgical approaches. More recently, the development of minimally invasive surgery (MIS) techniques has avoided patellar eversion by subluxing the patella. The present study is the first to measure patellar blood flow during MIS TKA with the knee in both extension and 90 degrees of flexion followed by lateral retraction and then eversion of the patella. Methods. Patellar blood flow was measured using laser Doppler flowmetry in 40 patients during MIS TKA. Patients included 32 women and 8 men who had a mean age of 73 years (range, 52 to 88 years) and a mean weight of 59 kg (39 to 85 kg). The pre-operative diagnoses were osteoarthritis in 36 patients and rheumatoid arthritis in four patients. All patients underwent MIS TKA using the mini-midvastus approach. After initial blood flow was assessed with the leg in full extension, further measurements were performed after lateral retraction and after eversion of the patella. Then, blood flow was assessed with the knee in 90 degrees of flexion followed by lateral retraction and then eversion of the patella. Results. For measurements made during knee extension, a significant reduction in flow was observed during eversion of the patella compared with the neutral patellar position (P < 0.001). However, no significant difference was found between lateral retraction of the patella and the neutral patellar position. A significant reduction in flow was noted when the leg was flexed from full extension to 90 degrees (P < 0.001). For measurements made with the knee in 90 degrees of flexion, a significant reduction in flow was observed during eversion of the patella (P = 0.002) and a significant increase was noted during lateral retraction of the patella compared with the neutral position (P < 0.001). Conclusion. Patella eversion may result in traction both on medial vessels and those within the quadriceps mechanism, whereas, lateral retraction reduces the force exerted on the arteries within the quadriceps after the medial blood supply was interrupted by medial arthrotomy. In addition, the position of the leg had a great impact on patellar blood flow. MIS TKA without patellar eversion may be useful for preventing a reduction in patellar blood flow


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 408 - 412
1 Mar 2007
Ma H Lu Y Kwok T Ho F Huang C Huang C

One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines.

The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58°; 0.14° to 29.9°) and with its own patellar component (mean 11.36°; 0.55° to 39.19°). In the other four prostheses, the conformity was better (mean 2.25°; 0.02° to 10.52°) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51°; 0.07° to 9.89°) than the Miller-Galante II prosthesis (mean 11.20°; 5.80° to 16.72°) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57°; 1.40° to 4.56°) or high angles of flexion (mean 4.54°; 0.91° to 9.39°), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39°; 0.04° to 4.56°). There was no significant difference (p > 0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion.

The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation.