Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 63 - 63
1 Apr 2018
Lum Z Coury J Huff K Trzeciak M
Full Access

Introduction

One method of surgical site infection prevention is lowering intraoperative environmental contamination. We sought to evaluate our hospitals operating room (OR) contamination rates and compare it to the remainder of the hospital. We tested environmental contamination in preoperative, intraoperative and postoperative settings of a total joint arthroplasty patient.

Materials & Methods

190 air settle plates composed of trypsin soy agar (TSA) were placed in 19 settings within our hospital. Locations included the OR with light and heavy traffic, with and without masks, jackets, and shoe covers, sub-sterile rooms, OR hallways, sterile equipment processing center, preoperative areas, post-anesthesia care units, orthopaedic floors, emergency department, OR locker rooms and restrooms, a standard house in the local community, and controls.

The plates were incubated in 36 degrees celsius for 48 hours and colony counts were recorded. Numbers were averaged over each individual area.