Abstract. Introduction. Displaced
The purpose of this study is to determine the re-operation rate following plate fixation of the
Osteotomy through the bare area of
We investigated whether an alternative tension band wire technique will produce greater compression and less displacement at
Avulsion fractures of the tip of the
Intraarticular fractures of the distal humerus comprise 1% of all fractures in adults. Triceps reflecting and
Adequate exposure is a prerequisite for treatment of distal humeral fractures. In this study, we compared the clinico-radiological and functional outcome of TRAP approach with that of
Aims. Compression and absolute stability are important in intra-articular fractures such as transverse
In the setting of traumatic elbow injuries involving coronoid fractures, the relative size of the coronoid fragment has been shown to relate to the stability of the joint. Currently, the challenge lies in accurately classifying the amount of bone loss in coronoid fractures. In comminuted fractures, bone loss is difficult to measure with plain radiographs or computed tomography. The purpose of this study is to describe a novel radiographic measure, the Coronoid Opening Angle (COA), on lateral elbow radiographs. We demonstrate the relationship of the COA to coronoid height and describe how this measure can be used to estimate bone loss and potentially predict elbow instability following coronoid fracture. Radiographs were drawn from a regional database in a consecutive fashion. Candidate radiographs were excluded on the basis of radiographic evidence of degenerative changes, previous surgery or injury, bony deformity, and inadequate lateral view of the elbow. The COA was measured as the angle between the long axis of the ulna at the level of the trochlear notch, and the tip of coronoid, from a common origin at the posterior cortex of the
This study reviews the early results of Distal Humeral Hemiarthroplasty(DHH) for distal humeral fracture and proposed a treatment algorithm incorporating the use of this technique in the overall management of distal humeral fractures. DHH was performed on 30 patients (mean 65 years; 29-91) for unreconstructable fractures of the distal humerus or salvage of failed internal fixation. A triceps on approach was used in six and an
Total elbow arthroplasty (TEA) usage is increasing owing to expanded surgical indications, better implant designs, and improved long-term survival. Correct humeral implant positioning has been shown to diminish stem loading in vitro, and radiographic loosening in in the long-term. Replication of the native elbow centre of rotation is thought to restore normal muscle moment arms and has been suggested to improve elbow strength and function. While much of the focus has been on humeral component positioning, little is known about the effect of positioning of the ulnar stem on post-operative range of motion and clinical outcomes. The purpose of this study is to determine the effect of the sagittal alignment and positioning of the humeral and ulnar components on the functional outcomes after TEA. Between 2003 and 2016, 173 semi-constrained TEAs (Wright-Tornier Latitude/Latitude EV, Memphis, TN, USA) were performed at our institution, and our preliminary analysis includes 46 elbows in 41 patients (39 female, 7 male). Patients were excluded if they had severe elbow deformity precluding reliable measurement, experienced a major complication related to an ipsilateral upper limb procedure, or underwent revision TEA. For each elbow, saggital alignment was compared pre- and post-operatively. A best fit circle of the trochlea and capitellum was drawn, with its centre representing the rotation axis. Ninety degree tangent lines from the intramedullary axes of the ulna and humerus, and from the
Aim. Skeletal tuberculosis (TB) accounts for up to one third of cases of extra-pulmonary TB but comprises a minority of osteoarticular infection in areas with low TB incidence. Consequently, unexpected cases may receive surgical management targeted at non-tuberculous orthopaedic infections. This study reviewed treatment and outcomes of non-spinal osteoarticular TB to assess outcomes from modern surgical techniques. Method. All patients with a diagnosis of non-spinal osteoarticular TB between 2009–2017 from one tertiary referral centre were included. Retrospective review of surgical intervention, antibiotic treatment and outcome was conducted. Results. Fourteen patients with an average age of 48 (range 20–77) were identified; all were HIV-negative. Articular infections affected 7 patients, including one prosthetic joint infection. Osteomyelitis affecting the carpus, femur, tibia,
Trans-articular coronal shear fractures of the distal humerus pose a significant challenge to the surgeon in obtaining an anatomical reduction and rigid fixation and thereby return of good function. A variety of approaches have been described which include the extended lateral and anterolateral approaches and arthroscopically-assisted fixation for non-comminuted fractures. Fixation methods include open or percutaneous cannulated screws and headless compression screws directed either anterior to posterior or posterior to anterior. We describe an illustrated, novel approach to this fracture which is minimally invasive but enables an anatomical reduction to be achieved. A 15 year old male presented with a Bryan and Morrey type 4 fracture as described by McKee involving the left distal humerus. He was placed in a lateral position with the elbow over a support. A posterior longitudinal incision and a 6cm triceps split from the tip of the
Aim. Treatment for distal third shaft fractures of humerus is very challenging especially if its comminuted and bone is osteopenic. They are commonly treated with plating. Plating has complications of iatrogenic radial nerve palsy. We report our case series of distal third fractures of humerus treated with retrograde Halder Humeral Nail. Materials and methods. Since 1994 to 2010 we have 576 fractures of humerus treated with retrograde Halder Humeral nail. Of these 45 were distal third extra articular fractures of humerus. Average age of patients at the time of surgery was 30.4 years (Range 15–82 years, Median 33 years). Of 45 patients 26 were females and 19 males.3 out of 45 had non union at the time of presentation. The nail was locked distally with one or two screws and proximally with a screw and tripwire. The entry point of the nail was roof of
Aim. To assess clinical outcome of massive rotator cuff tear repair using triceps myotendinous flap. Method. This is a prospective cohort of 43 patients (24 male, 19 female) with average age of 62 years. The primary indication of surgery was pain. Patients with massive rotator cuff tear involving supraspinatus and infraspinatus, showing retraction and fatty infiltration in MRI were selected. Few (8/43) were with failed surgical treatment and rest had conservative treatment failed. They underwent rotator cuff repair during Feb 1999 to Jan 2004. The long head of the triceps was detached from the
Introduction. Although Total elbow arthroplasty (TEA) generally provides favorable clinical outcomes, its complications have been reported with high rate compared with other joints. Previously, we used the Bryan & Morrey approach in TEA, which included separating the triceps muscle subperiosteally from the
Background. The optimal treatment for symptomatic elbow osteoarthritis remains debatable especially in patients still involved in heavy manual work. The Outerbridge-Kashiwagi (OK) procedure has been used when simple measures fail. The aim of this study is to analyse the results of the OK procedure in patients with symptomatic osteoarthritis. Methods. Twenty-two patients were included in the study. The male:female ratio was 18:4. The mean age was 60 years with mean follow-up of 38 months (24–60 months). 17 were manual workers, 3 involved in sports activities and 2 non-manual workers. All patients were assessed using Mayo Elbow Performance Index Score system. Preoperative radiological assessment showed osteophytes around
The purpose of this study is to describe the use of the PHILOS plate (Synthes) in reverse configuration to treat complex distal humeral non-unions. Non-union is a frequent complication of distal humeral fracture. It is a challenging problem due to the complex anatomy of the distal humerus, small distal fragment heavily loaded by the forearm acting as a long lever arm with powerful forces increasing the chances of displacement. Rigid fixation and stability with a device of high “pull-out” strength is required. The PHILOS plate has been used in reverse configuration to achieve good fixation while allowing central posterior placement of the implant. 11 patients with established non-union of distal humeral fractures were included in this study. No patient in whom this implant was used has been excluded. Initial fixation was revised using the PHILOS plate in reverse configuration and good fixation was achieved. Bone graft substitutes were used in all cases. Patients were followed to bony union, and functional recovery. All fractures united. One required revision of plate due to fatigue failure. Average time to union was 8 months with excellent restoration of elbow function. A reversed PHILOS plate provides an excellent method of fixation in distal humeral non-union, often complicated by distorted anatomy and previous surgical intervention. It has a high “pull-out” strength and may be placed in the centre of the posterior humerus, allowing proximal extension of the fixation as far as is required. It provides secure distal fixation without impinging on the