Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 17 - 17
1 Aug 2013
Russell D Deakin A Fogg Q Picard F
Full Access

Conventional computer navigation systems using bone fixation have been validated in measuring anteroposterior (AP) translation of the tibia. Recent developments in non-invasive skin-mounted systems may allow quantification of AP laxity in the out-patient setting. We tested cadaveric lower limbs (n=12) with a commercial image free navigation system using passive trackers secured by bone screws. We then tested a non-invasive fabric-strap system. The lower limb was secured at 10° intervals from 0° to 60° knee flexion and 100N of force applied perpendicular to the tibial tuberosity using a secured dynamometer. Repeatability coefficient was calculated both to reflect precision within each system, and demonstrate agreement between the two systems at each flexion interval. An acceptable repeatability coefficient of ≤3 mm was set based on diagnostic criteria for ACL insufficiency when using other mechanical devices to measure AP tibial translation. Precision within the individual invasive and non-invasive systems measuring AP translation of the tibia was acceptable throughout the range of flexion tested (repeatability coefficient ≤1.6 mm). Agreement between the two systems was acceptable when measuring AP laxity between full extension and 40° knee flexion (repeatability coefficient ≤2.1 mm). Beyond 40° of flexion, agreement between the systems was unacceptable (repeatability coefficient >3 mm). These results indicate that from full knee extension to 40° flexion, non-invasive navigation-based quantification of AP tibial translation is as accurate as the standard invasive system, particularly in the clinically and functionally important range of 20° to 30° knee flexion. This could be useful in diagnosis and post-operative follow-up of ACL pathology


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 168 - 168
1 Jul 2014
Oosterwaal M Telfer S Woodburn J Witlox A Hermus J van Rhijn L Meijer K
Full Access

Summary Statement. An alternative way to assess three dimensional skin motion artefacts of kinematic models is presented and applied to a novel kinematic foot model. Largest skin motion is measured in the tarsal region. Introduction. Motion capture systems are being used in daily clinical practise for gait analysis. Last decade several kinematic foot models have been presented to gain more insight in joint movement in various foot pathologies. No method is known to directly measure bone movement in a clinical setting. Current golden standard is based on measurement of motion of skin markers and translation to joint kinematics. Rigid body assumptions and skin motion artefacts can seriously influence the outcome of this approach and rigorous validation is required before clinical application is feasible. Validation of kinematic models is currently done via comparison with bone pin studies. However, these studies can only assess major bones in a highly invasive way; another problem is the non-synchronous measurement of skin markers and bone pins. Recently the Glasgow Maastricht kinematic foot model, which comprises all 26 foot segments, has been presented. To validate the model we propose a novel non-invasive method for the assessment of skin motion artefact, involving loaded CT data. Patients & Methods. 25 subjects (healthy and pathological feet) have undertaken CT scans. These CT-scans have been obtained in 1 unloaded and 3 varying loading conditions. CT-slices are 3D reconstructed and segmented. The principal axes of the segmented bones were derived from the surface points of the bones. These principal axes are used to compute bone orientation. Subsequently, coordinate systems of bones in the different loading conditions were matched. Markers were translated and rotated to orientations of their corresponding bones. Maximal distance between markers is calculated per subject to asses the influence of skin motion. Results. Preliminary results of 9 subjects show largest positional differences for markers associated with the cuneiform lateralis (5.7 ± 3.2 mm) and cuneiform intermedium (7.7 ± 3.7 mm). Smallest positional differences are found on the hallux proximalis (0.9 ± 0.34mm). Spatial resolution is too small to accurately calculate orientation of smaller bones, therefor distal phalanges 2–5 are not taken into account in the analysis. Discussion/Conclusion. Skin motion is a major cause of inaccuracy in gait analysis. This is the first study presenting an automated non-invasive method to calculate the 3D orientation of skin markers with respect to the coordinate system of the corresponding bone(s). Largest skin motion is measured in the tarsal region. Future work will be in calculation of the effect of skin motion in the accuracy of joint angle calculation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 98 - 98
1 Aug 2012
Cook R Curwen C Tasker T Zioupos P
Full Access

Osteoporosis (OP) results in a reduction in the mechanical competence of the bone tissue of the sufferers. In skeletal sites such as the proximal femur and the vertebrae, OP manifests itself in low trauma fragility fractures which are debilitating for the patient. The relationships between the compressive strength of cancellous tissue and its apparent density are well established in studies of the past. Recently the authors have presented a method able to assess the fracture toughness properties of cancellous bone (1), a challenging cellular material which can exhibit large elasto-plastic deformations. The in-vitro measurement of fracture toughness alongside the customary compressive strength can provide a comprehensive assessment of the mechanical capacity of cancellous bone, which will reflect closer its ability to resist crack initiation. The aims of the present study were: (1) to examine whether the observed fracture toughness deterioration can also be detected by non-invasive quantitative ultrasound (QUS); and (2) to provide rational evidence for the well proven ability of QUS to predict directly ‘risk of fracture’. 20 femoral heads were obtained from donors undergoing emergency surgery for a fractured neck of femur. QUS investigations of the calcaneus, proximal phalanx and distal radius were undertaken within 72 hours of surgery. 128 fracture toughness samples and 20 compression cores were manufactured and tested. Two clinical QUS systems were used to obtain in-vivo scan data and then directly compared those to the density, porosity and the fracture mechanics of tissue extracted from the same individuals. The results demonstrated not only that there was a significant link between in-vivo determined QUS values for the calcaneus and finger to the density of the density of the femoral head; but that there was also a significant link between the QUS results from the calcaneus and the fracture toughness of the cancellous bone from the femoral head. These results point towards a systemic effect of osteoporosis which affects similarly different parts of the skeleton and supports the use of clinical QUS systems as a diagnostic tool for the prediction of fracture risk


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 45 - 45
17 Apr 2023
Cao M Zhu X Ong M Yung P Jiang Y
Full Access

To investigate temporal changes in synovial lymphatic system (SLS) drainage function after Anterior cruciate ligament (ACL) injury, a non-invasive ACL rupture model was used to induce the PTOA phenotype without altering the SLS structure. We have created a non-invasive ACL rupture model in the right knee (single overload impact) of 12- week-old C57bl/6 male mice to mimic the ACL rupture-induced PTOA development. 70 kDa-TxRedDextran were injected into the right knee of the mice at 0, 1, 2, and 4 wks post modeling (n=5/group), and the fluorescence signal distribution and intensity were measured by the IVIS system at 1 and 6 hrs post-injection. After 24 hrs, the drainage lymph nodes and whole knee joint were harvested and subjected to ex vivo IVIS imaging and immunofluorescence detection respectively. Manual ACL rupture was induced by 12N overloaded force and validated by a front drawer test. Intraarticular clearance of TxRed-Dextran detected by the IVIS was significantly reduced at 1, and 2 wks at a level of 43% and 55% respectively but was not significantly different from baseline levels at 4 wks (89%). TxRed-Dextran signal in draining lymph nodes was significantly reduced at 1 week at the level of but not for 2 and 4 wks compared to baseline levels (week 1–29%, week 2–50%, week 4–94%). TxRed-Dextran particle was significantly enriched in the synovium at 1, 2 wks but was not significantly different from baseline levels at 4 wks rupture-post ACL rupture (Particle numbers: Sham Ctrl-34 ±14, week 1, 113 ± 17; week 2, 89 ± 13; week 4, 46 ± 18; mean ± SD). We observed the drainage function of SLS significantly decreased at 1 and 2 wks after the ACL rupture, and was slowly restored at 4 wks post-injury in a non-invasive ACL rupture model. Early impairment of SLS drainage function may lead to accumulation of inflammatory factors and promote PTOA progression


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 65 - 65
17 Apr 2023
Tacchella C Lombardero SM Clutton E Chen Y Crichton M
Full Access

In this work, we propose a new quantitative way of evaluating acute compartment syndrome (ACS) by dynamic mechanical assessment of soft tissue changes. First, we have developed an animal model of ACS to replicate the physiological changes during the condition. Secondly, we have developed a mechanical assessment tool for quantitative pre-clinical assessment of ACS. Our hand-held indentation device provides an accurate method for investigations into the local dynamic mechanical properties of soft tissue and for in-situ non-invasive assessment and monitoring of ACS. Our compartment syndrome model was developed on the cranial tibial and the peroneus tertius muscles of a pig's leg (postmortem). The compartment syndrome pressure values were obtained by injecting blood from the bone through the muscle. To enable ACS assessment by a hand-held indentation device we combined three main components: a load cell, a linear actuator and a 3-axis accelerometer. Dynamic tests were performed at a frequency of 0.5 Hz and by applying an amplitude of 0.5 mm. Another method used to observe the differences in the mechanical properties inside the leg was a 3D Digital Image Correlation (3D-DIC). Videos were taken from two different positions of the pig's leg at different pressure values: 0 mmHg, 15 mmHg and 40 mmHg. Two strains along the x axis (Exx) and y axis (Eyy) were measured. Between the two pressure cases (15 mmHg and 40 mmHg) a clear deformation of the model is visible. In fact, the bigger the pressure, the more visible the increase in strain is. In our animal model, local muscle pressures reached values higher than 40 mmHg, which correlate with observed human physiology in ACS. In our presentation we will share our dynamic indentation results on this model to demonstrate the sensitivity of our measurement techniques. Compartment syndrome is recognised as needing improved clinical management tools. Our approach provides both a model that reflects physiological behaviour of ACS, and a method for in-situ non-invasive assessment and monitoring


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 78 - 78
11 Apr 2023
Vind T Petersen E Lindgren L Sørensen O Stilling M
Full Access

The Pivot-shift test is a clinical test for knee instability for patinets with Anterior cruciate ligament (ACL), however the test has low inter-observer reliability. Dynamic radiostereometry (dRSA) imaging is a highly precise method for objective evaluation of joint kinematics. The purpose of the study was to quantify precise knee kinematics during Pivot-shift test by use of the non-invasive dynamic RSA imaging. Eight human donor legs with hemipelvis were evaluated. Ligament lesion intervention of the ACL was performed during arthroscopy and anterolateral ligament (ALL) section was performed as a capsular incision. Pivot-shift test examination was recorded with dRSA on ligament intact knees, ACL-deficient knees and ACL+ALL-deficient knees. A Pivot-shift pattern was identifyable after ligament lesion as a change in tibial posterior drawer velocity from 7.8 mm/s in ligament intact knees, to 30.4 mm/s after ACL lesion, to 35.1 mm/s after combined ACL-ALL lesion. The anterior-posterior drawer excursion increased from 2.8 mm in ligament intact knees, to 7.2 mm after ACL lesion, to 7.6 mm after combined lesion. Furthermore a change in tibial rotation was found, with increasing external rotation at the end of the pivot-shift motion going from intact to ACL+ALL-deficient knees. This experimental study demonstrates the feasibility of RSA to objectively quantify the kinematic instability patterns of the knee during the Pivot-shift test. The dynamic parameters found through RSA displayed the kinematic changes from ACL to combined ACL-ALL ligament lesion


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 43 - 43
2 Jan 2024
Nürnberger S
Full Access

Photobiomodulation (PBM), the use of light for regenerative purposes, has a long history with first documentations several thousand years ago in ancient Egypt and a Nobel Price on this topic at the beginning of last century (by Niels Finsen). Nowadays, it is in clinical use for indications such as wound healing, pain relief and anti-inflammatory treatment. Given the rising numbers of in vitro studies, there is increasing evidence for the underlying mechanisms such as wavelength dependent reactive oxygen production and adenosine triphosphate generation. In cartilage regeneration, the use of PBM is controversially discussed with divergent results in clinics and insufficient in vitro studies. As non-invasive therapy, PMB is, though, of particular importance, since a general regenerative stimulus would be of great benefit in the otherwise only surgically accessible tissues. We therefore investigated the influence of different wavelengths - blue (475 nm), green (516 nm) or red (635 nm) of a low-level laser (LLL) - on the chondrogenic differentiation of chondrocytes and adipose derived stromal cells of different human donors and applied the light in different settings (2D, 3D) with cells in a proliferative or differentiating stage. All assessed parameters (spheroid growth, histology, matrix quantification and gene expression) revealed an influence of LLL on chondrogenesis in a donor-, wavelength- and culture-model-dependent manner. Especially encouraging was the finding, that cells with poor chondrogenic potential could be improved by one single 2D treatment. Amongst the three wave lengths, red light was the most promising one with the most positive impact. Although in vivo data are still missing, these in vitro results provide evidence for a proper biofunctional effect of LLL


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 6 - 6
2 Jan 2024
Orellana F Grassi A Wahl P Nuss K Neels A Zaffagnini S Parrilli A
Full Access

A comprehensive understanding of the self-repair abilities of menisci and their overall function in the knee joint requires three-dimensional information. However, previous investigations of the meniscal blood supply have been limited to two-dimensional imaging methods, which fail to accurately capture tissue complexity. In this study, micro-CT was used to analyse the 3D microvascular structure of the meniscus, providing a detailed visualization and precise quantification of the vascular network. A contrast agent (μAngiofil®) was injected directly into the femoral artery of cadaver legs to provide the proper contrast enhancement. First, the entire knee joint was analysed with micro-CT, then to increase the applicable resolution the lateral and medial menisci were excised and investigated with a maximum resolution of up to 4 μm. The resulting micro-CT datasets were analysed both qualitatively and quantitatively. Key parameters of the vascular network, such as vascular volume fraction, vessel radius, vessel length density, and tortuosity, were separately determined for the lateral and medial meniscus, and their four circumferential zones defined by Cooper. In accordance with previous literature, the quantitative micro-CT data confirm a decrease in vascular volume fraction along the meniscal zones. The highest concentration of blood vessels was measured in the meniscocapsular region 0, which is characterized by vascular segments with a significantly larger average radius. Furthermore, the highest vessel length density observed in zone 0 suggests a more rapid delivery of oxygen and nutrients compared to other regions. Vascular tortuosity was detected in all circumferential regions, indicating the occurrence of vascular remodelling in all tissue areas. In conclusion, micro-CT is a non-invasive imaging technique that allows for the visualization of the internal structure of an object in three dimensions. These advanced 3D vascular analyses have the potential to establish new surgical approaches that rely on the healing potential of specific areas of the meniscus. Acknowledgements: The authors acknowledge R. Hlushchuk, S. Halm, and O. Khoma from the University of Bern for their help with contrast agent perfusions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 48 - 48
2 Jan 2024
Faydaver M Russo V Di Giacinto O El Khatib M Rigamonti M Rosati G Raspa M Scavizzi F Santos H Mauro A Barboni B
Full Access

Digital Ventilated Cages (DVC) offer an innovative technology to obtain accurate movement data from a single mouse over time [1]. Thus, they could be used to determine the occurrence of a tendon damage event as well as inform on tissue regeneration [2,3]. Therefore, using the mouse model of tendon experimental damage, in this study it has been tested whether the recovery of tissue microarchitecture and of extracellular matrix (ECM) correlates with the motion data collected through this technology. Mice models were used to induce acute injury in Achilles tendons (ATs), while healthy ones were used as control. During the healing process, the mice were housed in DVC cages (Tecniplast) to monitor animal welfare and to study biomechanics assessing movement activity, an indicator of the recovery of tendon tissue functionality. After 28 days, the AT were harvested and assessed for their histological and immunohistochemical properties to obtain a total histological score (TSH) that was then correlated to the movement data. DVC cages showed the capacity to distinguish activity patterns in groups from the two different conditions. The data collected showed that the mice with access to the mouse wheel had a higher activity as compared to the blocked wheel group, which suggests that the extra movement during tendon healing improved motion ability. The histological results showed a clear difference between different analyzed groups. The bilateral free wheel group showed the best histological recovery, offering the highest TSH score, thus confirming the results of the DVC cages and the correlation between movement activity and structural recovery. Data obtained showed a correlation between TSH and the DVC cages, displaying structural and movement differences between the tested groups. This successful correlation allows the usage of DVC type cages as a non-invasive method to predict tissue regeneration and recovery. Acknowledgements: This research is part of the P4FIT project ESR13, funded by the H2020-ITN-EJD MSCA grant agreement No.955685


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 22 - 22
17 Apr 2023
Murugesu K Decruz J Jayakumar R
Full Access

Standard fixation for intra-articular distal humerus fracture is open reduction and internal fixation (ORIF). However, high energy fractures of the distal humerus are often accompanied with soft tissue injuries and or vascular injuries which limits the use of internal fixation. In our report, we describe a highly complex distal humerus fracture that showed promising healing via a ring external fixator. A 26-year-old man sustained a Gustillo Anderson Grade IIIB intra-articular distal humerus fracture of the non-dominant limb with bone loss at the lateral column. The injury was managed with aggressive wound debridement and cross elbow stabilization via a hinged ring external fixator. Post operative wound managed with foam dressing. Post-operatively, early controlled mobilization of elbow commenced. Fracture union achieved by 9 weeks and frame removed once fracture united. No surgical site infection or non-union observed throughout follow up. At 2 years follow up, flexion - extension of elbow is 20°- 100°, forearm supination 65°, forearm pronation 60° with no significant valgus or varus deformity. The extent of normal anatomic restoration in elbow fracture fixation determines the quality of elbow function with most common complication being elbow stiffness. Ring fixator is a non-invasive external device which provides firm stabilization of fracture while allowing for adequate soft tissue management. It provides continuous axial micro-movements in the frame which promotes callus formation while avoiding translation or angulation between the fragments. In appropriate frame design, they allow for early rehabilitation of joint where normal range of motion can be allowed in controlled manner immediately post-fixation. Functional outcome of elbow fracture from ring external fixation is comparable to ORIF due to better rehabilitation and lower complications. Ring external fixator in our patient achieved acceptable functional outcome and fracture alignment meanwhile the fracture was not complicated with common complications seen in ORIF. In conclusion, ring external fixator is as effective as ORIF in treating complex distal humeral fractures and should be considered for definitive fixation in such fractures


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 32 - 32
1 Dec 2022
Ricci A Boriani L Giannone S Aiello V Marvasi G Toccaceli L Rame P Moscato G D'Andrea A De Benedetto S Frugiuele J Vommaro F Gasbarrini A
Full Access

Scoliosis correction surgery is one of the longest and most complex procedures of all orthopedic surgery. The complication rate is therefore not negligible and is particularly high when the surgery is performed in patients with neuromuscular or connective tissue disease or complex genetic syndromes. In fact, these patients have various comorbidities and organ deficits (respiratory capacity, swallowing / nutrition, heart function, etc.), which can compromise the outcome of the surgery. In these cases, an accurate assessment and preparation for surgery is essential, also making use of external consultants. To make this phase simpler, more effective and homogeneous, a multidisciplinary path of peri-operative optimization is being developed in our Institute, which also includes the possibility of post-operative hospitalization for rehabilitation and recovery. The goal is to improve the basic functional status as much as possible, in order to ensure faster functional recovery and minimize the incidence of peri-operative complications, to be assessed by clinical audit. The path model and the preliminary results on the first patients managed according to the new modality are presented here. The multidisciplinary path involves the execution of the following assessments / interventions: • Pediatric visit with particular attention to the state of the upper airways and the evaluation of chronic or frequent inflammatory states • Cardiological Consultation with Echocardiogram. • Respiratory Function Tests, Blood Gas Analysis and Pneumological Consultation to evaluate indications for preoperative respiratory physiotherapy cycles, Non-Invasive Ventilation (NIV) cycles, Cough Machine. Possible Polysomnography. • Nutrition consultancy to assess the need for nutritional preparation in order to improve muscle trophism. • Consultation of the speech therapist in cases of dysphagia for liquids and / or solids. • Electroencephalogram and Neurological Consultation in epileptic patients. • Physiological consultation in patients already being treated with a cough machine and / or NIV. • Availability of postoperative hospitalization in the rehabilitation center (with skills in respiratory and neurological rehabilitation) for the most complex cases. When all the appropriate assessments have been completed, the anesthetist in charge at our Institute examines the clinical documentation and establishes whether the path can be considered complete and whether the patient is ready for surgery. At the end of the surgery, the patient is admitted to the Post-operative Intensive Care Unit of the Institute. If necessary, a new program of postoperative rehabilitation (respiratory, neuromotor, etc.) is programmed in a specialist reference center. To date, two patients have been referred to the preoperative optimization path: one with Ullrich Congenital Muscular Dystrophy, and one with 6q25 Microdeletion Syndrome. In the first case, the surgery was performed successfully, and the patient was discharged at home. In the second case, after completing the optimization process, the surgery was postponed due to the finding of urethral malformation with the impossibility of bladder catheterization, which made it necessary to proceed with urological surgery first. The preliminary case series presented here is still very limited and does not allow evaluations on the impact of the program on the clinical practice and the complication rate. However, these first experiences made it possible to demonstrate the feasibility of this complex multidisciplinary path in which a network of specialists takes part


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 40 - 40
17 Nov 2023
Kuder I Jones G Rock M van Arkel R
Full Access

Abstract. Objectives. Ultrasound speckle tracking is a safe and non-invasive diagnostic tool to measure soft tissue deformation and strain. In orthopaedics, it could have broad application to measure how injury or surgery affects muscle, tendon or ligament biomechanics. However, its application requires custom tuning of the speckle-tracking algorithm then validation against gold-standard reference data. Implementing an experiment to acquire these data takes months and is expensive, and therefore prohibits use for new applications. Here, we present an alternative optimisation approach that automatically finds suitable machine and algorithmic settings without requiring gold-standard reference data. Methods. The optimisation routine consisted of two steps. First, convergence of the displacement field was tested to exclude the settings that would not track the underlying tissue motion (e.g. frame rates that were too low). Second, repeatability was maximised through a surrogate optimisation scheme. All settings that could influence the strain calculation were included, ranging from acquisition settings to post-processing smoothing and filtering settings, totalling >1,000,000 combinations of settings. The optimisation criterion minimised the normalised standard deviation between strain maps of repeat measures. The optimisation approach was validated for the medial collateral ligament (MCL) with quasi-static testing on porcine joints (n=3), and dynamic testing on a cadaveric human knee (n=1, female, aged 49). Porcine joints were fully dissected except for the MCL and loaded in a material-testing machine (0 to 3% strain at 0.2 Hz), which was captured using both ultrasound (>14 repeats per specimen) and optical digital image correlation (DIC). For the human cadaveric knee (undissected), 3 repeat ultrasound acquisitions were taken at 18 different anterior/posterior positions over the MCL while the knee was extended/flexed between 0° and 90° in a knee extension rig. Simultaneous optical tracking recorded the position of the ultrasound transducer, knee kinematics and the MCL attachments (which were digitised under direct visualisation post testing). Half of the data collected was used for optimisation of the speckle tracking algorithms for the porcine and human MCLs separately, with the remaining unseen data used as a validation test set. Results. For the porcine MCLs, ultrasound strains closely matched DIC strains (R. 2. > 0.98, RMSE < 0.59%) (Figure 1A). For the human MCL (Figure 1B), ultrasound strains matched the strains estimated from the optically tracked displacements of the MCL attachments. Furthermore, strains developed during flexion were highly correlated with AP position (R = 0.94) with strains decreasing the further posterior the transducer was on the ligament. This is in line with previously reported length change values for the posterior, intermediate and anterior bundles of the MCL. Conclusions. Ultrasound speckle tracking algorithms can be adapted for new applications without ground-truth data by using an optimisation approach that verifies displacement field convergence then minimises variance between repeat measurements. This optimisation routine was insensitive to anatomical variation and loading conditions, working for both porcine and human MCLs, and for quasi-static and dynamic loading. This will facilitate research into changes in musculoskeletal tissue motion due to abnormalities or pathologies. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 18 - 18
1 Aug 2013
Russell D Deakin A Fogg Q Picard F
Full Access

Non-invasive assessment of lower limb mechanical alignment and assessment of knee laxity using navigation technology is now possible during knee flexion owing to recent software developments. We report a comparison of this new technology with a validated commercially available invasive navigation system. We tested cadaveric lower limbs (n=12) with a commercial invasive navigation system against the non-invasive system. Mechanical femorotibial angle (MFTA) was measured with no stress, then with 15 Nm of varus and valgus moment. MFTA was recorded at 10° intervals from full knee extension to 90° flexion. The investigator was blinded to all MFTA measurements. Repeatability coefficient was calculated to reflect each system's level of precision, and agreement between the systems; 3° was chosen as the upper limit of precision and agreement when measuring MFTA in the clinical setting based on current literature. Precision of the invasive system was superior and acceptable in all conditions of stress throughout flexion (repeatability coefficient <2°). Precision of the non-invasive system was acceptable from extension until 60° flexion (repeatability coefficient <3°), beyond which precision was unacceptable. Agreement between invasive and non-invasive systems was within 1.7° from extension to 50° flexion when measuring MFTA with no varus / valgus applied. When applying varus / valgus stress agreement between the systems was acceptable from full extension to 30° knee flexion (repeatability coefficient <3°). Beyond this the systems did not demonstrate sufficient agreement. These results indicate that the non-invasive system can provide reliable quantitative data on MFTA and laxity in the range relevant to knee examination


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 99 - 99
1 Nov 2021
Gunay H Sozbilen MC Mirzazade J Bakan OM
Full Access

Introduction and Objective. Septic arthritis is an acute infective presentation of the joint calling for urgent intervention, thus making the differential diagnosis process difficult. An increase in temperature in the area containing the suspected septic arthritis is one of the clinically important findings. In this study, it was aimed to investigate whether or not the temperature changes obtained through thermal camera can be used as a new additional diagnostic tool in the differential diagnosis of septic arthritis. Materials and Methods. The study was approved by the local ethics committee as a prospective cohort. A total of 49 patients, 15 septic and 34 non-septic ones, both male and female ones from all ages admitted to the emergency room or evaluated with the consultation of another clinics who were also present with a pre-diagnosis of arthritis (septic or non-septic) in the knee (with complaints of redness, swelling, pain, effusion, increased temperature, edema, and inability to walk) were included in the study. The patients with non-joint inflammatory problems and a history of surgery in the same joint were excluded from the study. The temperature increase in the joint area with suspected septic arthritis was observed, and the difference in temperature changes of this suspicious area with the joint area of the contralateral extremity was compared after which the diagnosis of septic arthritis was confirmed by taking culture with routine intra-articular fluid aspiration, which is the gold standard for definitive diagnosis. Results. The mean age of the patients was 39.89 ± 27.65°C. A significant difference was found between the group with and without septit arthritis in terms of ASO, sedimentation, and leukocyte increase in the analysis of joint fluid (p <0.05). When the thermal measurements were compared, the mean temperature was 37.93°C in the septic group, while it was 36.79°C in the non-septic group, which showed a significant difference (p <0.000∗). The mean temperature difference in both joints was 3.40°C in the septic group, while 0.94°C in the non-septic group (p <0.000∗). While the mean temperature was 37.10°C in the group with septit arthritis, it was measured to be 35.89 °C in the group without (p <0.020). A very strong positive correlation was found between the difference between the mean temperatures of both groups and the values of the hottest and coldest temperature points (r = 0.960, r = 0.902). Conclusions. In the diagnosis of septic arthritis, a thermal imager can be used as a non-invasive diagnostic tool. With the help of this device, a quantitative value, in addition to palpation, can be given to the local temperature increase in the joint, which is an important finding in the clinic of septic arthritis. In future studies, specially designed thermal devices developed with special software for septic arthritis can be developed


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 73 - 73
1 Mar 2021
Murphy B McCabe J
Full Access

Abstract. Objective. Spinal cord surgery is a technically challenging endeavour with potentially devastating complications for patients and surgeons. Intra-operative neurophysiological monitoring(IONM), or spinal cord monitoring (SCM), is one method of preventing and identifying damage to the spinal cord. At present, indications for its use are based more on individual surgeon preference and for medico legal purposes. Our study aimed to determine IONM's utility as a clinical tool. Methods. This is a retrospective case series of 169 patients who underwent spinal surgery with IONM at two institutions between 2013 and 2018. Signal changes detected were recorded as well as the surgeon's response to these changes. Patients were followed up to one-year post-surgery using our institution's EVOLVE system. The main outcome measure in this study was new post-operative neurological signs and/or symptoms and what effect, if any, IONM and subsequent surgeon intervention had on these complications. Result. Indications for IONM included cervical stenosis, cervical disc prolapse, unstable fractures and bony metastases. Signal changes were observed in 33% (n=55) of cases. 24 of these patients responded to re-positioning. There were 7 total complications with full resolution by 12 months. False negative rate was 2.4% (n=4). There was one true positive. The largest cohort of patients included those who experienced no signal changes and subsequently no post-operative deficits (n=124). Conclusion. IONM is a non-invasive clinical tool that may be utilised for medicolegal reasons. Its use as a clinical tool is questionable given its relatively high false negative rate and low false positive rate. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 84 - 84
1 Mar 2021
Mobasheri A
Full Access

Sarcopenia is a progressive and generalized skeletal muscle disorder that involves loss of muscle mass and function. It is associated with increased adverse outcomes including falls, functional decline, frailty and mortality and affects 65% of people over the age of 65 more than half of people aged 80 and above. The factors that cause and worsen sarcopenia are categorised into two groups. The primary aetiological factor is ageing and the secondary factors include disease, physical inactivity, and poor nutrition. Sarcopenia is considered to be ‘primary' (or age-related) when no other specific cause is evident. However, a number of ‘secondary' factors may be present in addition to ageing. Sarcopenia can occur secondary to a systemic or inflammatory disease, including malignancy and organ failure. Physical inactivity is one of the major contributors to the development of sarcopenia, whether due to a sedentary lifestyle or to disease related immobility or disability. Furthermore, sarcopenia can develop as a result of inadequate protein consumption. Biomarkers are objective and quantifiable characteristics of physiological and pathophysiological processes. Biomarkers can be used to predict the development of sarcopenia in older susceptible adults and enable early interventions that can reduce the risk of physical disability, the co-morbidities associated with the loss of muscle mass and the poor health outcomes that result from sarcopenia. Non-invasive imaging technologies can be used as biomarkers to detect loss of skeletal muscle mass in sarcopenia include bone densitometry, computed tomography, ultrasound and magnetic resonance imaging. However, imaging requires sophisticated and expensive equipment that is not available in a resource poor setting. Therefore, markers of skeletal muscle strength and fitness and soluble biochemical markers in blood may be used as alternative biomarkers. Studies on sarcopenia have identified numerous soluble biochemical biomarkers. These biomarkers can be divided into two groups: “muscle-specific” and “non-muscle-specific” biomarkers. Since sarcopenia is associated with rapid skeletal muscle wasting, the skeletal muscle-specific isoform of troponin T may be considerate a useful biomarker of sarcopenia, since high troponin levels in blood are an expression of muscle wasting. Peptides derived from collagen type VI turnover may be potential biomarkers of sarcopenia. We have recently conducted a systematic review to summarize the data from recent mass-spectrometry based proteomic studies of the secretome of skeletal muscle cells in response to disease, exercise or metabolic stress in order to identify the proteins involved in muscle breakdown. Developing robust in vitro models for the study of sarcopenia using primary muscle cells is a high priority as is exploiting the in vitro models to understand catabolic and inflammatory processes and molecular mechanisms involved in sarcopenia. Co-cultures with adipose-derived and other cells may be used to screen for small molecules and biologicals capable of inhibiting the catabolic and inflammatory pathways involved in sarcopenia. This presentation reviews recent progress in this area and outlines opportunities for future research on sarcopenia


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 16 - 16
1 Dec 2020
Kontakis MG Schou J Hailer N
Full Access

Bone tissue engineering attempts at substituting critical size bone defects with scaffolds that can be primed with osteogenic cells, usually mesenchymal stem cells (MSC) from the bone marrow. Although overlooked, peripheral blood is a valuable source of MSC and circulating osteoprogenitors (COP), bearing a significant regenerative potential, and peripheral blood is easier to access than bone marrow. We thus studied osteodifferentiation of peripheral blood mononuclear cells (pbMNC) under different culture conditions, and how they compared to primary human osteoblasts. pbMNC were isolated from healthy adult volunteers by Ficoll density gradient centrifugation, and they were then cultured using media supplemented with 100nM Dexamethasone, 10mM sodium β-glycero phosphate and ascorbic acid (either 40mM or 0.05mM). For comparison, primary osteoblasts were isolated from the femoral heads of patients undergoing hip arthroplasty. After 4 weeks of culture, osteogenic activation was quantified with spectrometric measurement of alkalic phosphatase (ALP) and lactate dehydrogenase (LDH) levels. The extent of osteoid mineralization was measured with Alizarin red staining. We studied the effects of 1) varying cell concentration at seeding, 2) surface coating of culture wells with collagen and 3) high compared to low ascorbic acid (40mM and 0.05mM) media. Higher numbers of pbMNC (0.5–5.9 versus 0.062–0.25 million cells per well) at seeding resulted in a lower ALP/LDH-ratio (mean ± standard deviation), 0.39 ± 0.33 arbitrary units (AU) versus 1.36 ± 1.06 AU, but led to higher amount of osteoid production, 0.10 ± 0.06 versus 0.065 ± 0.02 AU, p < 0.05. Culture of pbMNC on collagen did not confer any difference in ALP/LDH-ratios, with 0.43 ± 0.3 AU for collagen-coated and 0.43 ± 0.41 AU for uncoated wells (p = 0.95), and we also observed no relevant difference in osteoid production (0.07 ± 0.01 AU for collagen-coated versus 0.1 ± 0.08 AU for uncoated wells, p = 0.28). Cultures of pbMNC on collagen in media supplemented with a higher concentration of ascorbic acid showed a 130% higher ALP/LDH-ratio when compared to cultures exposed to a lower ascorbic acid concentration (p < 0.05). Cultures with a low initial concentration of pbMNC (0.5 − 1 million cells) had no significantly different ALP/LDH-ratio when compared to primary human osteoblasts, but the cultures of pbMNC resulted in a 90% increase in osteoid mineralization when compared to primary human osteoblasts (p < 0.05). These findings indicate that progenitor cells derived from peripheral blood have a significant osteogenic potential, rendering them interesting candidates for seeding of scaffolds intended to fill critical sized bone defects. pbMNC produced almost double the amount of osteoid as primary osteoblasts. The isolation of pbMSC and COP is non-invasive and easy, and they might be seeded directly onto scaffolds without prior ex-vivo expansion, a question that we intend to pursue further


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 25 - 25
1 Oct 2016
Sowoidnich K Churchwell JH Buckley K Kerns JG Goodship AE Parker AW Matousek P
Full Access

Development of more effective diagnostic and therapeutic solutions is vital to tackling the growing challenge of bone diseases and disorders in aging societies. Spatially offset Raman spectroscopy (SORS) enables the chemical specificity of conventional Raman spectroscopy to be combined with sub-surface probing. SORS has successfully been applied to transcutaneous investigations of underlying bone and shows great potential to become an in vivo tool for non-invasive diagnosis of various bone conditions. The volume within the complex hierarchical bone tissue probed by SORS depends on the specimen's optical properties. Understanding the actual sampling depth is important to correctly assign detected chemical changes to specific areas in the bone. This study explores the hypothesis that the effective Raman signal recovery from certain depths requires different spatial offsets depending on the bone mineralisation. SORS depth investigations were conducted on three bones with significantly different mineralisation levels. Thin slices (0.6 – 1.0 mm thickness) were cut from deer antler, horse metacarpal and whale tympanic bulla and stacked together (4 – 7 layers; 4.1 – 4.7 mm total thickness). A 0.38 mm thin slice of polytetrafluoroethylene (PTFE) served as reference sample and was inserted in between the layers of stacked bone slices. Raman spectra were acquired at 30 s using 830 nm excitation. A quantitative relation between the SORS offset and the primarily interrogated depth inside the bone was established. Maximum accessible depths at small offset strongly depend on the mineralisation level. Using large spatial offsets of 7 – 9 mm PTFE signal recovery depths of 4.4 – 4.6 mm through cortical bone can be realized with only minor dependence on the bone mineralisation. These findings highlight the potential of SORS for medical diagnostics by enabling the non-invasive detection of bone conditions characterised by chemical alterations several millimetres inside compact bone tissue (e.g. infections, tumours, etc.)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 110 - 110
1 Jan 2017
Lin C Lu T Zhang S Hsu C Frahm J Shih T
Full Access

Non-invasive, in vivo measurement of the three-dimensional (3-D) motion of the tibiofemoral joint is essential for the study of the biomechanics and functional assessment of the knee. Real-time magnetic resonance imaging (MRI) techniques enable the measurement of dynamic motions of the knee with satisfactory image quality and free of radiation exposures but are limited to planar motions in selected slice(s). The aims of the current study were to propose a slice-to-volume registration (SVR) method in conjunction with dual-slice, real-time MRI for measuring 3-D tibiofemoral motion; and to evaluate its repeatability during passive knee flexion. Eight healthy young adults participated in the current study, giving informed written consent as approved by the Institutional Research Board. A 3-T MRI system (Verio, Siemens, Erlangen, Germany) incorporated with a neck matrix coil was used to collect the MRI data. A 3-D scanning using the VIBE sequence was used to collect the volumetric data of the knee at fully extended position (TR = 4.64 ms, TE = 2.3 ms, flip angle = 15°, in-plane resolution = 0.39 × 0.39 mm. 2. and slice thickness = 0.8 mm). A real-time MRI using the refocused radial FLASH sequence (TR = 4.3 ms, TE = 2.3 ms, flip angle = 20°, in-plane resolution = 1.0 × 1.0 mm. 2. , slice thickness = 6 mm) was used to acquire a pair of image slices of the knee at a frame rate of 3 fps during passive flexion. The volumetric MRI data sets were segmented for the femur and tibia/fibula to isolate the sub-volumes containing bone segments. A slice-to-volume registration method was then performed to determine the 3-D poses of the bones based on the spatial matching between sub-volume of the bones and the real-time image slices. The bone poses for all frames were used to calculate the rigid-body kinematics of the tibiofemoral joint in terms of the flexion/extension (FE), internal/external rotation (IR/ER), abduction/adduction (Abd/Add) and joint center translations along three anatomical axis of the tibia. The procedures were carried out five times for repeatability analysis. The standard deviation (SD) of the rigid-body kinematics for each frame from the five trials were calculated and then averaged across all frames to give quantitative measures of the repeatability of the kinematic variables. The repeatability analysis showed that the mean±SD of the averaged SD in FE, Abd/Add and IR/ER components across all subjects were 0.25±0.09, 0.46±0.13 and 0.77±0.16 degrees, respectively. The corresponding values for the joint translations in anterior/posterior, proximal/distal and medial/lateral directions were 0.21±0.04, 0.11±0.03 and 0.43±0.09 mm. An SVR method in conjunction with dual-slice real-time MRI has been successfully developed and its repeatability in measuring 3-D motion of the tibiofemoral joint evaluated. The results show that the proposed method is capable of providing rigid-body kinematics with sub-millimeter and sub-degree precision (repeatability). The proposed SVR method using real-time MRI will be a valuable tool for non-invasive, functional assessment of the knee without involving ionizing radiation, and may be further developed for joint stability assessment


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 14 - 14
1 Nov 2018
Baker B Mercer D
Full Access

The treatment of extremity ballistic injury is challenging in that the zone of injury can be extensive and determining the surgical exposure can be difficult. We describe a method of pre-operative evaluation of the zone of injury in conjunction with the regional anesthesiologist utilizing ultrasound to determine the presence of nerve disruption. This non-invasive method of examination may elucidate whether significant nerve exists and may also serve to pinpoint the location of injury. Such information allows the surgeon to more effectively and efficiently surgically expose the zone of injury and understand the boundaries of the nerve outside the zone of injury. Moreover, such preoperative evaluation may at times obviate the need for exploratory surgery at all. It is important for the anesthesiologist and surgeon to work together with respect to the ability to both interpret the ultrasound images and to clinically correlate the findings. The zone of tissue disruption in ballistic injuries is extremely variable. It is beneficial to both the surgeon and patient to engage in a collaborative effort with an experienced regional anesthesiologist who is well-versed in interpretation of ultrasound images and tissue plane disruption in an effort to minimize surgical time and the potential unintended consequences of unnecessary exploration. We present a series of cases representing instances wherein the zone of injury was small, extensive, and a unique situation in which there was in fact no injury present despite clinical symptoms and MRI consistent with radial nerve disruption