Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Bone & Joint Research
Vol. 6, Issue 5 | Pages 323 - 330
1 May 2017
Pijls BG Sanders IMJG Kuijper EJ Nelissen RGHH

Objectives. Infection of implants is a major problem in elective and trauma surgery. Heating is an effective way to reduce the bacterial load in food preparation, and studies on hyperthermia treatment for cancer have shown that it is possible to heat metal objects with pulsed electromagnetic fields selectively (PEMF), also known as induction heating. We therefore set out to answer the following research question: is non-contact induction heating of metallic implants effective in reducing bacterial load in vitro?. Methods. Titanium alloy cylinders (Ti6Al4V) were exposed to PEMF from an induction heater with maximum 2000 watts at 27 kHz after being contaminated with five different types of micro-organisms: Staphylococcus epidermidis; Staphylococcus aureus; Pseudomonas aeruginosa; spore-forming Bacillus cereus; and yeast Candida albicans. The cylinders were exposed to incremental target temperatures (35°C, 45°C, 50°C, 55°C, 60°C, 65°C, 70°C) for up to 3.5 minutes. Results. There was an average linear heating rate of 0.39°C per second up to the target temperature, and thereafter the target temperature was maintained until the end of the experiment. At 60°C and higher (duration 3.5 minutes), there was a 6-log reduction or higher for every micro-organism tested. At 60°C, we found that the shortest duration of effective induction heating was 1.5 minutes. This resulted in a 5-log reduction or higher for every micro-organism tested. Conclusion. Non-contact induction heating of a titanium disk is effective in reducing bacterial load in vitro. These promising results can be further explored as a new treatment modality for infections of metal orthopaedic implants. Cite this article: B. G. Pijls, I. M. J. G. Sanders, E. J. Kuijper, R. G. H. H. Nelissen. Non-contact electromagnetic induction heating for eradicating bacteria and yeasts on biomaterials and possible relevance to orthopaedic implant infections: In vitro findings. Bone Joint Res 2017;6:323–330. DOI: 10.1302/2046-3758.65.BJR-2016-0308.R1


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 99 - 99
1 Nov 2018
Pijls B Sanders I Kuijper E Nelissen R
Full Access

The main problem of infected orthopaedic implants is that the presence of microorganisms in an organized biofilm making them difficult accessible for antibiotics. This biofilm consists of a complex community of microorganisms embedded in an extracellular matrix that forms on surfaces such as an implant. Non-contact induction heating uses pulsed electromagnetic fields to induce so-called ‘eddy currents’ within metal objects which causes them to heat up. This heat causes thermal damage to the bacterial biofilm hence killing the bacteria on the metal implant. The purpose of this study is to determine the effectiveness of induction heating on killing Staphylococcus epidermidis in a biofilm. S. epidermidis biofilms were grown on Titanium alloy (Ti6Al4V) coupons and subsequently were heated with a custom-built induction heater to temperatures of 60°C, 70°C, 80°C and 90°C for 3.5 minutes. Temperature was controlled with an infra-red thermal sensor and micro-controller. We also included two control conditions without induction heating: C1 without induction heating and C2 with chlorhexidine 0.5% in 70% alcohol without induction heating. Experiments were repeated 5 times. In the C1 group (no induction heating), 1.3 * 10(7) colony forming units (CFU)/cm(−2) of S. epidermidis were observed. For 60°C, 70C, 80 C and 90C, a 3.9-log reduction, 5.3-log reduction, 5.5-log reduction and 6.1-log reduction in CFU/cm(−2) were observed, respectively. For the C2 (chlorhexidine) there was a 6.7-log reduction CFU/cm(-2). We concluded that induction heating of Titanium coupons is effective in reducing bacterial load in vitro for S. epidermidis biofilms