Aims. Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the
The UK National Joint Registry(NJR) has not reported total knee replacement (TKR)survivorship based on design philosophy alone, unlike its international counterparts. We report outcomes of implant survivorship based on design philosophy using data from NJR's 2020 annual report. All TKR implants with an identifiable design philosophy from NJR data were included. Cumulative revision data for cruciate-retaining(CR), posterior stabilised(PS), mobile-bearing(MB) design philosophies was derived from merged NJR data. Cumulative revision data for individual brands of implants with the medial pivot(MP) philosophy were used to calculate overall survivorship for this design philosophy. The all-cause revision was used as the endpoint and calculated to 15 years follow-up with Kaplan-Meier curves.Abstract
Background and study aim
Materials and methods
Mortality following hip arthroplasty is affected by a large number of confounding variables each of which must be considered to enable valid interpretation. The aim of this study was to establish whether it is possible to determine a true cause-and-effect relationship between the risk of mortality and data that are routinely collected by the NJR and to establish the degree to which variation in the mortality rate could be explained by each variable. Relevant variables available from the 2011 NJR data setwere included in a Cox model. We carried out two analyses: Firstly, we conducted an analysis of data collected from the NJR data set used in preparation of the NJR's 8th Annual Report (2011) looking for an association between the variables collected and the risk of mortality. Secondly, as social deprivation is also known to influence mortalityrates but is not routinely collected as part of the NJR data set, a further analysis was performed which included social deprivation data derived from partial postcodes. Mortality rates in hip arthroplasty patients were lower than in the age matched population across all hip types. Age at surgery, ASA grade, diagnosis, gender, provider type, hip type and lead surgeon grade all had a significant effect on mortality. Schemper's statistic showed that only 18.98% of the variation in mortality was explained by the variables available in the NJR data set. It is inappropriate to use Registry data to study an outcome affected by a multitude of confounding variables when these cannot be adequately accounted for in the available data set.
Current analysis of unicondylar knee replacements (UKR) by national registries is based on the pooled results of medial and lateral implants. Using data from the National Joint Registry for England and Wales (NJR) we aimed to determine the proportion of lateral UKR implanted, their survival and reason for failure in comparison to medial UKR. By combining information on the side of operation with component details held on the NJR we were able to determine implant laterality (medial vs. lateral) for 32,847 of the 35,624 (92%) UKR registered before December 2010. Kaplan Meier plots, Life tables and Cox' proportion hazards were used to compare the risk of failure for lateral and medial UKRs after adjustment for patient and implant covariates.Background
Methods
This study utilised NJR primary hip data from the 6th Annual Report to determine the rate and indication for revision between cemented, uncemented, hybrid and resurfacing prosthetic groups. Regression analysis was performed to identify the influence of gender and ASA grade on these revision rates. Validity of the data was interrogated by exploring for episodes of misclassification. We identified 2,264 misclassified episodes within the four groups (Misclassification rate 2.7% primary, 4.3% revision procedures). Analysis was performed using the “reclassified dataset”. The Kaplan-Meier revision rates at 3 years were 0.9% (95%CI: 0.8%-1.0%) for cemented prostheses, 1.9% (95%CI: 1.8%-2.0%) for uncemented hips, 1.2% (95%CI: 1.0%-1.4%) for hybrids and 3.0%, (95%CI: 2.7%-3.3%) in the resurfacing group. The trends in revision rates were comparable to those published in the NJR (6th Edn.) with significant differences across all groups (p< 0.0001). Revision rates in the under 55 year age group showed an identical hierarchy with cemented and hybrid arthroplasty having the lowest revision rates. Cox Regression analysis indicated that both the prosthesis group in isolation and the interaction between prosthesis group and ASA grade significantly influenced the rate of failure (p< 0.001). Indications for revision showed significant differences in rates for, pain, aseptic loosening, dislocation and malalignment between prosthesis types (p< 0.001). The indications including Aseptic loosening, pain, malalignment and dislocation all demonstrated similar trends in revision rates between prosthetic groups with cemented hips having the lowest rates followed by ascending rates for hybrid, uncemented and resurfacing groups. The exception being dislocation with resurfacings having the lowest revision rates. This study provides important baseline revision rates by indication for each prosthetic group from which future comparisons can be made. Areas of misclassification within the NJR dataset have been reported back for future annual analysis.Results
Discussion
The most appropriate form of chemical thromboprophylaxis following knee replacement is a contentious issue. Most national guidelines recommend the use of low molecular weight Heparin (LMWH) whilst opposing the use of aspirin. We compared thromboembolic events, major haemorrhage and death after knee replacement in patients receiving either aspirin or LMWH. Data from the National Joint Registry for England and Wales was linked to an administrative database of hospital admissions in the English National Health Service. A total of 156 798 patients undergoing knee replacement between April 2003 and September 2008 were included and followed up for 90 days. Multivariable risk modelling was used to estimate odds ratios adjusted for baseline risk factors (AOR). An AOR < 1 indicates that risk rates are lower with LMWH than with aspirin.Background
Methods
A commonly held belief amongst surgeons and patients is that progression of disease (arthritis) to other compartments is a major cause of early failure of UKRs. We analysed the NJR database records of 17,643 primary UKRs performed between April 2003 and April 2009. Where these had been revised the reason for revision was noted.Background
Methods
National Institute for Health and Clinical Excellence (NICE) guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractured neck of femur (NOF) in cognitively intact patients who were independently mobile prior to the injury. The National Joint Registry for England and Wales (NJR) has collected data on THRs performed since 2003. This retrospective cohort study explores risk factors independently associated with implant failure and perioperative mortality. NJR data recording a THR performed for acute fractured NOF between 2003 and 2010 were analysed. Cox proportional hazards models were used to analyse the extent to which risk of implant revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting 90-day perioperative mortality. Significance was taken as p< 0.01.Introduction
Methods
In order to emulate normal knee kinematics more closely and thereby potentially improve wear characteristics and implant longevity the Medial Pivot type knee replacement geometry was designed. In the current study the clinical and radiographic results of 50 consecutive knee replacements using a Medial Pivot type knee replacement are reported; results are compared to the Australian Orthopaedic Associations National Joint Replacement Registry. The patients' data were crossed checked against the registry to see if they had been revised elsewhere. After a mean follow-up of 9.96 years results show that the Medial Pivot Knee replacement provides good pain relief and functional improvement according to KSS and Womac scores and on subjective patient questionnaires. There was one minor revision; insertion of a patella button at 6.64 years FU. There were no major revisions; all implants appeared to be well fixed on standard radiographic examination. While the revision rate for the Medial Pivot knee according to the Australia Joint Registry results is higher compared to all other types of knee replacements in the registry, and to what is reported in the literature on the medial pivot knee, it is not in the current series. Revision rate was similar to what is reported on in the literature, but after a longer follow-up period. However, long term follow-up is required to draw definitive conclusions on the longevity of this type of implant.
Following in-depth analysis of the market leading brand combinations in which we identified implant influences on risk of revision, we compared revision in patients implanted with different categories of hip replacement in order to find implant with the lowest revision risk, once known flawed options were removed. All patients with osteoarthritis who underwent a hip replacement (2003–2010) using an Exeter-Contemporary (cemented), Corail-Pinnacle (cementless), Exeter-Trident (Hybrid) or a Birmingham Hip resurfacing (BHR) were initially included within the analysis. Operations involving factors that were significant predictors of revision were excluded. Cox proportional hazard models were then used to assess the relative risk of revision for a category of implant (compared with cemented), after adjustment for patient covariates.Introduction
Methods
Abstract. Background. Although tantalum is a well recognised implant material used for revision arthroplasty, little is known regarding the use of the same in primary total hip arthroplasty. Methods. A literature search was performed to find all relevant clinical studies until March 2020, which then underwent a further selection criteria. The inclusion criteria was set as follows: Reporting on human patients undergoing primary total hip arthroplasty; Direct comparison between tantalum acetabular cups with conventional acetabular cups. for use in primary total hip arthroplasty; Radiological evaluation (cup migration, osteointegration); Clinical (functional scores, need for subsequent revision, patient-reported outcomes; Post-operative complications; Reporting findings in the English Language. After a thorough search a total of six studies were included in the review. The primary outcome. measures were clinical outcomes, implant migration, change in bone mineral density and rate of revision and infection. Results. Tantalum was found superior to titanium with regards to fewer radiolucencies, survivorship, osteointegration, decreased osteolysis and mechanical loosening. No significant difference in radioisometric analysis, bone mineral density or Harris Hip Score was found. Revision and infection rates were found to be significantly lower in tantalum group at 10 years from pooled data of
Introduction. A key outcome measured by
Failure of cephalomedullary fixation for proximal femur fractures is an uncommon event associated with significant morbidity to the patient and cost to the healthcare system. This institution changed nailing system from the PFNA (DePuy Synthes) to InterTan (Smith and Nephew) in February 2020. To assess for non-inferiority, a retrospective review was performed on 247 patients treated for unstable proximal femur fractures (AO 31 A2; A3). Patients were identified through manual review of fluoroscopic images. Stable fracture patterns were excluded (AO 31 A1). Pre/post operative imaging, demographic data, operative time and ASA scores assessed. Internal/external imaging and
Aim. Aim was to compare revision rates when using single versus dual antibiotic loaded cement (ABLC) in hip fracture arthroplasty and aseptic revision hip or knee arthroplasty using data from the Dutch
Aims. The primary aim is to estimate the current and potential number of patients on NHS England orthopaedic elective waiting lists by November 2020. The secondary aims are to model recovery strategies; review the deficit of hip and knee arthroplasty from
Introduction. Patellar resurfacing is performed in more than 90% of primary total knee arthroplasties (TKAs) in the United States, yet far fewer patellae are resurfaced internationally. Multiple randomized controlled trials have shown decreased revision rates in patients with resurfaced patellas (RP) vs. non-resurfaced (NR). However, most of these studies showed no difference in patient satisfaction, anterior knee pain, or knee society scores. (Figure 1) Given uncertain benefits, the purpose of this study was to determine if the rates of patellar resurfacing have changed over the past 10 years worldwide. Methods. Data was obtained via direct correspondence with registry administrators or abstracted from the annual reports of six
Critics of Unicompartmental knee replacement (UKR) highlight poor survivorship in
Metal-on-metal bearings (MoM), in both a total hip and resurfacing application, saw an increase in global utilization in the last decade. This peaked in 2008 in the US, with approximately 35% of bearings being hard-on-hard (metal-on-metal or ceramic-on-ceramic). Beginning in 2008, reports in the orthopaedic literature began to surface regrading local soft tissue reactions and hypersensitivity to metal-on-metal bearings. A major implant manufacturer recalled a resurfacing device in 2010 after
In the United Kingdom's