Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 53 - 53
1 Dec 2021
Osinga R Eggimann M Lo S Kühl R Lunger A Ochsner PE Sendi P Clauss M Schaefer D
Full Access

Aim. Reconstruction of composite soft-tissue defects with extensor apparatus deficiency in patients with periprosthetic joint infection (PJI) of the knee is challenging. We present a single-centre multidisciplinary orthoplastic treatment concept based on a retrospective outcome analysis over 20 years. Method. One-hundred sixty-seven patients had PJI after total knee arthroplasty. Plastic surgical reconstruction of a concomitant perigenicular soft-tissue defect was indicated in 49 patients. Of these, seven presented with extensor apparatus deficiency. Results. One patient underwent primary arthrodesis and six patients underwent autologous reconstruction of the extensor apparatus. The principle to reconstruct missing tissue ‘like with like’ was thereby favoured: Two patients with a wide soft-tissue defect received a free anterolateral thigh flap with fascia lata; one patient with a smaller soft-tissue defect received a free sensate, extended lateral arm flap with triceps tendon; and three patients received a pedicled medial sural artery perforator gastrocnemius flap, of which one with Achilles tendon. Despite good functional results 1 year later, long-term follow-up revealed that two patients had to undergo knee arthrodesis because of recurrent infection and one patient was lost to follow-up. In parts, results have been published under doi: 10.7150/jbji.47018. Conclusions. A treatment concept and its rationale, based on a single-centre experience, is presented. It differentiates between various types of soft-tissue defects and shows reconstructive options following the concept to reconstruct ‘like with like’. Despite good results 1 year postoperatively, PJI of the knee with extensor apparatus deficiency remains a dreaded combination with a poor long-term outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 30 - 30
1 May 2012
Y. M M. H K. G D. W A. M
Full Access

Introduction. Infection is disastrous in arthroplasty surgery and requires multidisciplinary treatment and debilitating revision surgery. Between 80-90% of bacterial wound contaminants originate from colony forming units (CFUs) present in operating room air, originating from bacteria shed by personnel present in the operating environment. Steps to reduce bacterial shedding should reduce wound contamination. These steps include the use of unidirectional laminar airflow systems and the introduction of theatre attire modelled on this principle (e.g. total body exhaust suits). Our unit introduced the use of the Stryker Sterishield Personal Protection System helmet used with laminar flow theatre systems. This study compares an enclosed helmet system used with standard gowns, with standard hood and mask attire. Method. 12 simulated hip arthroplasties were performed, six using disposable sterile impermeable gown, hood and mask and a further 6 using a Sterishield helmet and hood. Each 20 minute operation consisted of arm and head movements simulating movements during surgery. Air was sampled at wound level on a sterile draped operating table using a Casella slit sampler, sampling at 700l/minute. Samples were incubated on Blood agar for 48 hours at 37°c and the CFUs grown were counted. Results. Mean number of CFUs for the helmet was 9.33 with hood and mask attire having 49.16 CFUs (S. Ds 6.34 and 26.17; p value 0.0126). In all cases a coagulase negative staphylococcus was isolated. Conclusion. Although the sample size was small, we demonstrated a fivefold increase in the number of CFUs shed when using hood and mask attire compared to personal helmet and sterile hood. We conclude that the helmet system is superior to non-sterile hood and mask at reducing bacterial shedding by theatre personnel