Aim. To describe the impact of a failed DAIR in the further prognosis of the prosthesis after a PJI. Method. A retrospective
Aim. The frequency of arthroplasty among older people is increasing. Taking care of Prosthetic Joint infection (PJI) in this specific population is a challenge. The purpose of this
Background. One of the main concern about reverse shoulder arthoplasty for the treatment of rotator cuff deficiency is scapular notching that is still an unsolved issue for this particular prosthesis. The purpose of this
Septic arthritis diagnostic is an emergency which implies a treatment with antibiotics and hospitalization. The diagnosis is based on the cytobacteriological examination of the synovial fluid (SF), but direct bacteriological examination is insensitive, and the result of the culture is obtained only after several days. Therefore, there is still a need for a rapid, simple and reliable method for the positive diagnosis of septic arthritis. Such method must allow avoiding both unrecognized septic arthritis leading to major functional consequences, and overdiagnosis that will induce unnecessary expensive hospitalization and unjustified treatment. Mid-infrared (MIR) spectroscopy, that gives a metabolic profiling of biological fluids, has been proposed for early and fast diagnosis. To confirm the MIR spectroscopy to discriminate SF samples from patients with septic arthritis from other causes of joint effusion.Background
Objectives
Reverse shoulder prosthesis may lead to scapular notching, caused by attrition of the upper humeral component with scapular neck. We compared the clinical and radiographic results obtained with a SMR prosthesis, which allows a concentric or an eccentric glenosphere to be applied. 67 patients, mean age 73 years, were treated with reverse prosthesis using concentric and eccentric glenosphere. In patients with concentric glenosphere, the glenosphere extended about 4 mm below the glenoid. The eccentric glenosphere protected the upper glenoid neck by its inferior prolongment. Patients were followed for a mean of 33 months. At final F-U the Constant Score (C.S.) and the score with the Simple Shoulder test (S.S.T.) were calculated. Radiographs were obtained to evaluate the presence of scapular notching, psna (prosthesis-scapular neck angle), pgrd (peg- glenoid rim distance) and DBSNG (distance between scapular neck and glenosfere). Included in this study were patients, as much homogeneous as possible by age and pathology, 25 with concentric (Group I) and 30 with eccentric (Group II) glenosphere, who had a minimum F-U of 24 months. Statistical analysis was performed with a paired test.Purpose
Patients and methods
The causes for revision of primary total hip arthroplasty (THA) are various and quite well known. The developing use of dual-mobility THA (DM-THA) seems a relevant option to decrease the risk of instability. Due to lack of long-term follow-up, this innovative retentive concept is suspected to increase the risk of polyethylene (PE) wear. The aim of the study was to analyse the causes for DM-THA revision and assess whether or not its occurrence is different from that of fixed-standard (FS) THA, particularly for aseptic loosening or wear and/or osteolysis. The SoFCOT group conducted an observational prospective multicentre study from 1 January 2010 to 31 December 2011. Inclusion criteria comprised an exhaustive collection of 2044 first-revision THAs with 251 DM-THAs and 1793 FS-THAs. After excluding complications linked to patient factors (infection and periprosthetic fractures), we performed a matched case–control study (matching ratio 1:1) comparing two groups of 133 THAs.Introduction
Materials and methods
With resumption of elective spine surgery services following the first wave of COVID-19 pandemic, we conducted a multi-centre BASS collaborative study to examine the clinical outcomes of surgeries. Prospective data was collected from eight spinal centres in the first month of operating following restoration of elective spine surgery following the first wave. Primary outcomes measures were the 30-day mortality rate and postoperative Covid-19 infection rate. Secondary outcomes analysed were the surgical, medical adverse events and length of inpatient stay.Abstract
Aim
Methods
There have been many attempts to define the criteria by which prosthetic joint infection (PJI) is diagnosed. Our aim is to validate the 2021 European Bone and Joint Infection Society (EBJIS) definition of PJI. This is a multicenter retrospective study of patients who have undergone total hip or knee revision surgery in four different European institutions between 2013–2018. Cases with less than four intraoperative microbiology samples; no preoperative/intraoperative synovial fluid differential leukocyte count or intraoperative histology were excluded. Minimum follow-up of at least two years after revision surgery if no subsequent infection and/or the need for implant removal was also required. All cases were classified using the 2021 EBJIS, the 2018 International Consensus Meeting (ICM) and the 2013 Musculoskeletal Infection Society (MSIS) PJI definitions.Aim
Method
Aim. Megaprosthesis have become a standard option in limb preserving surgery after bone resection in musculoskeletal tumors. Recently they have also been used in complex revision arthroplasty in cases with massive bone loss. The aim of this study was to analyze the incidence of periprosthetic joint infection (PJI) both in primary oncology cases and aseptic revision cases and analyze which are the significant risk factors for PJI with a special interest on the use of prophylactic antibiotic loaded calcium sulfate beads. Method. All patients undergoing surgery with the use of megaprosthesis in our institution between January/2012 and December/2022 were retrospectively reviewed. Data was collected from electronic medical records. We identified 108 procedures involving megaprosthesis in 90 patients with an average follow-up of 37 months. Indications were 79 primary musculoskeletal tumors and 29 aseptic complex revision arthroplasty. Results. Table 1 shows relevant clinical information. No significant risk factor was found either in uni or multivariate analysis. PJI rate was 15% (12/79) for primary musculoskeletal surgery and 31% (9/29) for complex revision surgery. The use of antibiotic loaded calcium sulfate beads did not show an advantage – 22% (9/41) with vs. 18% (12/67) without. Conclusions. In this relatively small series it was not possible to show a significal association between PJI and certain known risk factors such as gender, ASA score, site of surgery (knee) and revision surgery. The use of antibiotic loaded calcium sulfate beads as prophylaxis was not beneficial in reducing PJI rates in our cohort. We acknowledge the limitations of our study: a small sample group, in a single institution with heterogeneity in terms of diagnosis and surgical site. We recognize the need for a
Aim. Bone and joint infections (BJI) need frequently prolonged antibiotic treatment at high dosage for a total of 6 or 12 weeks depending the type of infection. Impact of such prolonged antibiotic exposure on the gut microbiota has never been assessed. Method. We performed a national
Aims. Microbiological diagnosis of bone and joint infections (BJIs) is pivotal. However, no consensus exists about the best choice for techniques to be used and the best indications for molecular methods. Our objectives were: (i) to compare the performance of various microbiological diagnostic methods (cultural and molecular) on synovial fluid specimens and (ii) to select an algorithm for optimizing the diagnosis of BJIs in adults. Methods. This prospective
In France, 5% of men and 7% of women aged more than 60 years have a joint prosthesis (JP). The incidence of H-PJI following BSI remains unknown (1–2). The aim of this study was to determine prospectively the clinical characteristics of patients with JP and the incidence of H-PJI following a BSI. A prospective observational
Anatomically contoured periarticular plates for treatment of proximal tibia fractures is fast becoming the standard for care. The aim of our study was to assess the accuracy of the anatomic contour of proximal lateral tibial plates of AO Stryker and Zimmer in Indian patients. We assessed the accuracy of the anatomic contour of proximal lateral tibial plates of AO Stryker and Zimmer in 50 Indian dry tibiae. All the plates were placed on the 50 tibia by two independent surgeons according to what they felt was the best fit. The tibiae and the plate fits were mapped, quantified, and analysed using digital image capturing and adobe photoshop software. By corresponding the clinical appearance of good fit with our digital findings, we created numerical criteria for plate fit in three planes: coronal (volume of free space between the plate and bone), sagittal (alignment with the tibial plateau and shaft), and axial (match in curvature between the proximal horizontal part of the plate and the tibial plateau). An anatomic fit should mirror the shape of the tibia in all three planes and only ten plates of different companies qualified this. Recognising and understanding the substantial variations in fit that exist between anatomically contoured plates, it might be worthwhile developing proximal tibia plates specific for the Indian population or validating this study by having a larger
Introduction. Wear performances and fracture toughness of the alumina-matrix composite (AMC) Biolox-delta(r) are pointed out in the literature. This study is a prospective monocentric evaluation of 32 and 36 mm AMC/AMC bearing surfaces. Material and methods. 141 THA were included prospectively since 2006 in 127 patients. (62 females, 65 males, mean age 62, 2 years, mean BMI 25, 5). 134 cases were primary implantations. Mean follow-up is 40.9 months (29.8-53.4). In all patients we used the same cementless stem and cup. Clinical and radiological data were evaluated with a special attention for ceramic fracture and squeaking. Results. At follow-up mean HHS is 95.4. We faced current problems in this series (2 post-op.dislocations in non compliant patients, 1 hematoma, 3 early septic complications in immunodepressed patients). Intraoperative events were 3 non relevant femur fractures and 1 partial acetabular fracture. 4 cases needed a revision (1 cup and 1 stem loosening, 1 painful stem, 1 limb length discrepancy). No abnormal wear, osteolysis or implants migration could be detected in the other cases. No ceramic head fracture or liner chipping occurred. No patient reported squeaking. Discussion and conclusion. In this monocentric report the Delta COC articulation provides similar functional scores and survivorship as previously published ceramic on ceramic series. We did not observe ceramic fracture. Unusual rates of liner chipping have been described in an other
Aim. Propionibacterium acnes (PA) is an important cause of shoulder prosthetic joint infections (SPJIs) for which the optimal treatment has not yet been determined. Rifampicin and Levofloxacin both showed not benefit in recent experimental models of PA-SPJIs. We describe herein the experience of five different medical French centers in order to assess factors associated with patient's outcome with special emphasize on antibiotic regimens. Method. A
Purpose. Evaluate the demographics, stages and outcomes in Myxoid (ML) and Round Cell liposarcoma (RCL). Establish the incidence of local recurrence and metastases. Outline the use and benefits of radiotherapy and chemotherapy. Provide guidelines for future management of these rare tumors. Method.