Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 108 - 112
1 Jan 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Buckley L

Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions. There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection. The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants. We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 8 - 8
1 May 2019
Moriarty P Wong L Kearney D Harty J
Full Access

Revision hip arthroplasty presents a challenge in the setting of femoral bone loss. Tapered stems are susceptible to subsidence which leads to leg length inequality, hip instability and may necessitate repeat femoral revision surgery. The purpose of this study was to compare radiographic outcomes in two modular tapered revision systems with different distal stem geometries. We sought to establish the minimum postoperative stem bi-cortical contact length that predicts subsidence for tapered stems. This study examined revision total hip arthroplasties between 2009 and 2016 in a European university affiliated major trauma center. Modular stem A has a taper of 3 degrees whereas modular stem B has a taper of 2 degrees. Radiologic assessment compared x-rays at two time points: immediately post-surgery and most recent x-ray available at a minimum follow up of two years. Leg length discrepancy, subsidence and postoperative bi cortical contact was assessed. Descriptive summary statistics calculated clinical factors (i.e. age, gender, Paprosky classification). 122 arthroplasties were completed. Complete data was available for 112. Revisions were carried out for Paprovski grade 3a/ 3b femoral deficits. Post-operative bi-cortical contact of the proximal stem < 20mm was associated with higher subsidence rates (P = 0.047). Subsidence rates for implant A and B system were 4.27mm (0.12–25.62mm) and 3.43 mm (0.3–11.1 mm) respectively. Significant subsidence was noted in 9.8% (n=8) in implant A and 5.2%(n=2) in implant B. We conclude that immediate postoperative bi-cortical stem contact of <20mm was associated with significantly higher subsidence rates in this study


Aims. This study aimed to compare the change in health-related quality of life of patients receiving a traditional cemented monoblock Thompson hemiarthroplasty compared with a modern cemented modular polished-taper stemmed hemiarthroplasty for displaced intracapsular hip fractures. Patients and Methods. This was a pragmatic, multicentre, multisurgeon, two-arm, parallel group, randomized standard-of-care controlled trial. It was embedded within the WHiTE Comprehensive Cohort Study. The sample size was 964 patients. The setting was five National Health Service Trauma Hospitals in England. A total of 964 patients over 60 years of age who required hemiarthroplasty of the hip between February 2015 and March 2016 were included. A standardized measure of health outcome, the EuroQol (EQ-5D-5L) questionnaire, was carried out on admission and at four months following the operation. Results. Of the 964 patients enrolled, 482 died or were lost to follow-up (50%). No significant differences were noted in EQ-5D between groups, with a mean difference at four months of 0.037 in favour of the Exeter/Unitrax implant (95% confidence interval (CI) 0.014 to 0.087, p = 0.156), rising to 0.045 (95% CI 0.007 to 0.098, p = 0.09) when patients who died were excluded. The minimum clinically important difference for EQ-5D-5L used in this study is 0.08, therefore any benefit between implants is unlikely to be noticeable to the patient. There was no difference in mortality or mobility score. Conclusion. Allowing for the high rate of loss to follow-up, the use of the traditional Thompson hemiarthroplasty in the treatment of the displaced intracapsular hip fracture shows no difference in health outcome when compared with a modern cemented hemiarthroplasty. Cite this article: Bone Joint J 2018;100-B:352–60


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 153 - 153
1 Sep 2012
De Biase P Capanna R Campanacci D Beltrami G Scoccianti G Piccioli A
Full Access

The reconstruction of lower limb defects after oncological reconstructions is still a problem in limb salvage surgery. Large bony defects need to be treated with sound and durable reconstructions. During recent decades, the life expectancy of patients affected with cancer has improved considerably because of advances in chemotherapy, immunotherapy, hormonal treatment and radiotherapy. This improvement requires greater reliability in the reconstructive procedure in order to avoid mechanical failure during prolonged survival of the patient. The author experience with modular megaprosthesis by Link (megasystem C) allowed us to present a rapid, effective and functional solution. From June 2001 to December 2007 225 patients have been operated with a megaprosthesis C for tumoral resection. The new megaprosthesis C by Link represents a wide-ranging system that can afford a large variety of reconstructions in the inferior limb, from very short replacement of 5 cm in proximal femur, to a total femur and proximal tibia replacement. Modularity is represented by 1 cm increase in length. The different options of cemented and not cemented stem may be used with intraoperative decision. In cemented stem a rough collar seals the osteotomy and prevents polyethylene debris from entering the femoral canal by inducing a scar tissue around the stem entrance (so-called purse-string effect). Moreover in patients with solitary lesions and very good prognosis an allograft-prosthesis composite can be performed with improved clinical results on walking and function. Of the 225 patients that underwent tumoral resection and reconstruction with a modular megaprosthesis approximately 43% (97 cases) were operated for metastatic disease. Among these cases 55 cases were proximal femoral recontructions, 39 cases were distal femoral reconstructions and 3 cases were proximal tibial reconstructions. All cases were performed with cemented stems. We experienced a 7% of postoperative infections, 2% of dislocations of proximal femoral prosthesis and 3% of mechanical failures. While infections and dislocation rates were in the average for this surgery, mechanical failures were relatively high. We should consider that in patients with relatively long resections and muscle deficiency the mechanical stress exerted on the prosthesis can explain this kind of mechanical failure. However the new design of morse tapers have annulled these problems


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 158 - 158
1 Sep 2012
Funovics P Rois S Kotz R Dominkus M Windhager R
Full Access

Background. Modular endoprostheses today represent a standard treatment option in the management of musculoskeletal tumors of the lower extremities. Long-term results of these reconstructions, however, are often limited by the course of the underlying disease. We therefore report our experiences in cancer patients with megaprostheses of the lower limb after a minimum of 15 years. Materials and Methods. 62 patients, 34 men and 28 women, with a mean age of 26 years (median, 20; range, 6–83) were included in this investigation with a mean follow-up of 230 months (median, 228; range, 180–342). Endoprosthetic reconstructions of the proximal femur (11), the distal femur (28), the total femur (2) or the proximal tibia (21) were indicated for osteosarcoma (43), chondrosarcoma (5), malignant fibrous histiocytoma (3) or other tumors (11). All patients have received either a KMFTR (22) or a HMRS (40) modular prosthesis; 23 patients had a muscle flap, 14 had a fibular transposition osteotomy and 4 have received an artificial LARS ligament for soft-tissue reconstruction. Results. 7 patients (11.3%) died throughout the follow-up period, but none succumbed to primary disease. One patient (1.6%) developed a local recurrence after 31 months that was resected. Overall, 56 patients (90.3%) underwent revision of their prosthesis; 50 (80.7%) had multiple revisions up to a maximum of 12 operations (mean, 3 per patient). The median overall prosthetic survival to first revision was 40 months; the corresponding 5-, 10- and 15-year survival rates were 35.5%, 14.5% and 12.9%, respectively. 3 patients (5.4%) had an infection, 8 (14.3%) had a soft-tissue related failure, 30 (53.6%) had a mechanical or structural failure and 15 (26.8%) had an aseptic loosening. The 15-year survival rates of these respective endpoints were 87.1% for infection, 79.0% for soft-tissue related failure, 32.3% for mechanical or structural failure and 56.5% for aseptic loosening. 59 patients (95.2%) have retained their prosthesis; 2 patients (3.2%) underwent secondary amputation due to an irresolvable complication, another one (1.6%) for a second malignancy. Conclusion. Modular prosthetic reconstructions of the lower extremities have a high revision rate in the long-term, primarily due to mechanical failures. Given that patients survive their malignant disease the rate of secondary implant removal, however, tends to be low, providing satisfactory function and body integrity. Further advances in implant design, soft tissue management and infection prophylaxis are required to reduce revision rates


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 377 - 377
1 Sep 2012
Sellei R Kobbe P Knobe M Lichte P Pfeifer R Schmidt M Turner J Grice J Pape H
Full Access

Objectives. The additive use of an external modular device may improve dorsal compression forces in pelvic external fixation. This would improve the efficiency of indirect reduction and stabilization with an anterior pelvic external fixator. The purpose of this study was to determine the forces of the posterior pelvis achieved by a new device improving the application of a supraacetabular anterior external fixator compared with other constructs. Material and Method. Synthetic pelvic models were used. Complete pelvic ring instability was created by symphyseal and unilateral sacroiliac joint disruption. Four different constructs of fixation were tested. A pressure-sensitive film was placed in the sacroiliac joint. The constructs were applied in a standardized way. The maximum sacroiliacal compression loads (N) of each trial was recorded. Statistics was performed with the student t-test. Results. Standard supraacetabular two-pin external fixator achieved a dorsal compression load of 13.84 (SD 8.13). The new dorsal pelvic compression device delivered 177.05N (SD 32.32) of load across the sacroiliac joint when the pins were inserted half way and 183.58N (SD 46.64) with full pin insertion. Both the half- and full-pin construct demonstrated a significant dorsal load improvement with the pelvic compressor (p<0.05) compared with the standard supraacetabular fixator group. The C-clamp revealed compression forces of 384.88N (SD 22.95), which was significantly greater than all the other groups (p<0.05). Conclusion. We tested a simple and new modular device for improved application of pelvic external fixation. The centres of rotation of supra-acetabular pins were determined and used to achieve greater dorsal compression forces in disrupted pelvic ring injuries. The compression load is less than with a C-Clamp, but significantly greater than the familiar technique of standard external supra-acetabular fixation. This improves the initial stability in acute management of unstable, disrupted and life threatening pelvic ring fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 165 - 165
1 Sep 2012
Gebauer M Breer S Hahn M Kendoff D Amling M Gehrke T
Full Access

Introduction. Modular tantalum augments have been introduced to manage severe bone defects in hip and knee revision surgery. The porous surfaces of tantalum augments are intended to enhance osseointegration and a number of studies have documented their excellent biocompatibility. However, the characteristics of tantalum augment osseointegration on human ex vivo specimens from re-revision procedures have not been reported so far. Methods. Out of a total number of 324 hip and knee revisions with a tantalum augment performed in our institution between 2007 and 2010 four patients had to be re-revised at a mean followup time of 15 months. The causes for re-revision were a periprosthetic acetabular fracture in one, a loosening of a tibial component in one and periprosthetic hip infections in two cases. To characterize osseointegration of the tantalum augments, they were removed during revision surgery and subjected to undecalcified processing. All specimens were analysed by contact radiography, histology (toluidine blue, von Kossa) and quantitative histomorphometry. Results. In all specimens trabecular ingrowth was apparent along the former bone-augment-interface. The depth of bone ingrowth into the porous microarchitecture of the augments reached up to 2000 μm. Thin-section analysis revealed scattered and partially mineralized bone forming units within the interior of the augments. Conclusions. To the best of our knowledge this is the first histomorphometric analysis on the osseointegration of tantalum augments in human ex vivo specimens. In the presented series porous tantalum showed excellent osteoconductive characteristics on the histological level. These early ex vivo histological findings are promising, but structural analysis of later re-revision cases is needed


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims. The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Methods. Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined. Results. The AOANJRR identified 153 primary DFAs performed for native knee fractures in 151 patients during the study period, with 63.3% of these (n = 97) performed within the last five years. The median follow-up was 2.1 years (interquartile range 0.8 to 4.4). The patient population was 84.8% female (n = 128), with a mean age of 76.1 years (SD 11.9). The cumulative percent revision rate at three years was 10%. The most common reason for revision was loosening, followed by infection. Patient survival at one year was 87.5%, decreasing to 72.8% at three years postoperatively. Conclusion. The use of DFA to treat native knee fractures is increasing, with 63.3% of cases performed within the last five years. While long-term data are not available, the results of this study suggest that DFA may be a reasonable option for elderly patients with native knee fractures where fixation is not feasible, or for whom prolonged non-weightbearing may be detrimental. Cite this article: Bone Joint J 2022;104-B(7):894–901


Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims

Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade.

Methods

Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims

Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes.

Methods

Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1196 - 1200
1 Nov 2023
Parker MJ Chatterjee R Onsa M Cawley S Gurusamy K

Aims

The aim of this study was to report the three-year follow-up for a series of 400 patients with a displaced intracapsular fracture of the hip, who were randomized to be treated with either a cemented polished tapered hemiarthroplasty or an uncemented hydroxyapatite-coated hemiarthroplasty.

Methods

The mean age of the patients was 85 years (58 to 102) and 273 (68%) were female. Follow-up was undertaken by a nurse who was blinded to the hemiarthroplasty that was used, at intervals for up to three years from surgery. The short-term follow-up of these patients at a mean of one year has previously been reported.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 1 - 1
1 Sep 2012
Moideen AN Wolf C Donaldson O O'Doherty D
Full Access

Background. Exeter Trauma Stem (ETS) is a polished tapered collarless monopolar prosthesis used for cemented hemiarthroplasty for fracture neck of femur. Two modular rasps are available on the instrumentation set. The larger rasp, in practice, rarely fits into the femur making trial reduction impossible. Our hypothesis was that the absence of a trial reduction could affect leg length and stability of the prosthesis. Aim. To evaluate the leg length discrepancy following use of Exeter Trauma Stem for intracapsular fracture neck of femur. Methods. All patients who underwent ETS hemiarthroplasty between June 2009 to March 2010 (n = 100) were included in the study. Radiographic assessment of leg length was performed by two independent assessors based on measurements by Woolson et al. Results. Upto half of the patients had equal leg length measurements. Forty four patients had lengthening of the operated leg with a mean of 10mm (5–25). Further complications included four dislocations. There was no statistical significance between leg lengths and dislocations. Conclusion. Care is needed with regards to correct positioning of the ETS prosthesis to achieve equal leg lengths. Following this study a new intermediate sized modular rasp has been introduced to the instrumentation set


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 67 - 67
1 Sep 2012
Labek G Thaler M Agreiter M Williams A Krismer M Böhler N
Full Access

Introduction. Austin Moore cervicocephalic prostheses have been a therapeutical option for femoral neck fractures in patients with a reduced general condition for many years. Since treatments other than total hip arthroplasties have also been included in National arthroplasty registers during the last decade, adequate reference data for comparative analyses have recently become available. Materials and Methods. Based on a standardised methodology, a comprehensive literature analysis of clinical literature and register reports was conducted. On the one hand, the datasets were examined with regard to validity and the occurrence of possible bias factors, on the other hand, the objective was to compile a summary of the data available. The main criterion is the indicator of Revision Rate. The definitions used with respect to revisions and the methodology of calculations are in line with the usual standards of international arthroplasty registers. Results. Publications of clinical studies since the year 2000 have been found to significantly underestimate revision rates, on average by a factor of 2.15 as compared to register data. With 2 revisions per 100 observed component years, the revision rate in registers clearly exceeds the comparative values for total hip arthroplasty. The medium-term outcome of treatment with Austin Moore implants shows statistically significantly worse values than the use of total hip endoprostheses, bipolar implants or modular cervicocephalic prostheses. This may be rated as a hint that, in particular cases, there is potential for improvement as regards the indication for cervicocephalic implants. In the datasets of a single National register of a country such as Australia, with a population of just over 21.7 million, approximately 3 times as many cases have been documented within a period of 9 years than in all clinical studies that have been published in Medline-listed journals since the year 1960. Since these data are much more homogeneous, they allow for markedly more accurate evaluations and statements of higher validity. The period of time by which sufficient data are available for a well-founded recommendation is considerably shorter in a register. Conclusion. The results of a meta-analysis of clinical literature deviate conspicuously from data from a National arthroplasty register. The medium- and long-term revision rates after treatment with Austin Moore implants are significantly higher than for treatment with total hip prostheses or modular implants. There is evidence that more stringent indications for monobloc implants could improve the outcome of surgery


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1538 - 1543
1 Nov 2013
Kendrick BJL Wilson HA Lippett JE McAndrew AR Andrade AJMD

The National Institute for Health and Clinical Excellence (NICE) guidelines from 2011 recommend the use of cemented hemi-arthroplasty for appropriate patients with an intracapsular hip fracture. In our institution all patients who were admitted with an intracapsular hip fracture and were suitable for a hemi-arthroplasty between April 2010 and July 2012 received an uncemented prosthesis according to our established departmental routine practice. A retrospective analysis of outcome was performed to establish whether the continued use of an uncemented stem was justified. Patient, surgical and outcome data were collected on the National Hip Fracture database. A total of 306 patients received a Cathcart modular head on a Corail uncemented stem as a hemi-arthroplasty. The mean age of the patients was 83.3 years (. sd. 7.56; 46.6 to 94) and 216 (70.6%) were women. The mortality rate at 30 days was 5.8%. A total of 46.5% of patients returned to their own home by 30 days, which increased to 73.2% by 120 days. The implant used as a hemi-arthroplasty for intracapsular hip fracture provided satisfactory results, with a good rate of return to pre-injury place of residence and an acceptable mortality rate. Surgery should be performed by those who are familiar with the design of the stem and understand what is required for successful implantation. Cite this article: Bone Joint J 2013;95-B:1538–43


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 187 - 187
1 Sep 2012
Ruggieri P Calabrò T Valencia JD Mavrogenis A Romantini M Guerra G Mercuri M
Full Access

Aim. Bone metastases of the upper limb are a frequent complication of primary tumors. The aim of this study is to evaluate treatment and functional results of patients with prosthetic reconstruction of the proximal humerus. Method. Between 1975 and 2007, 67 patients were treated by resection of humeral metastasis and reconstruction with prosthesis. Cemented modular prostheses of the proximal humerus were implanted in 59 cases (all MRS Bioimpianti® prostheses), uncemented prostheses in 2 (HMRS® Stryker), 4 elbow Coonrad-Morrey prostheses (in 2 cases with bone allograft), 1 elbow custom-made cemented and 1 intercalary prosthesis (Osteobridge Merete®). Sites of primary tumors: kidney (23), lung (13), bone and unknow (7 each), liver and breast (3 each), bladder, endometrium, thyroid, soft tissues and nervous tissues (2 each), ovarium (1). Complications were evaluated and univariate analysis with actuarial Kaplan-Meier curves of implant survival was performed. Functional results were assessed with the MSTS system. Results. At mean follow-up 27 months oncologic outcome showed 7 patients NED (mean time 7 yrs.), 57 DOD, 3 lost to follow-up. Complications were deep infection (2 cases, 3%) and loosening (1 case, 1.5%) causing failure requiring revision. Functional results were good or excellent in 93% of patients, with average score of 71%. Conclusion. Resection of metastatic lesion is indicated: 1) for patients with solitary metastases and long free interval from treatment of primary cancer, 2) for patients with meta-epiphyseal metastases not amenable to durable internal fixation even in presence multiple metastases. Indications of resections are increasing, due to prolonged survival with newer medical treatments. Different reconstructive techniques are available, depending on type of resection and soft tissues removal. Cemented prostheses are mostly used, since cemented fixation is not affected by radiotherapy. Although prognosis was poor, prosthetic reconstructions of the humerus provided satisfactory results


Over the last few decades, the All-Poly Monoblock Tibia has been relegated to a minimum use in the major healthcare systems of the western world. The main reason for this has been the perception that this tibial component is inferior in its ability to withstand stresses. This perception originated and subsequently gained ground, due to certain historical reasons, leading to the widespread use of the modular metal-backed tibial component despite a higher cost. The recent economic downturn has enforced even the rich western healthcare systems to look for cost-effective solutions. The author works in India, where the society is still highly price-sensitive and takes value for money very seriously. Further, the routine ADL of the Indian population requires them to adopt high flexion postures such as cross-legged sitting and squatting. The author has used the All-Poly Tibia extensively, which is the most economical of tibial components. Further, he has developed a surgical technique which has resulted in his patients achieving high flexion (greater than 135 degrees) in more than 75% cases. This paper presents the 10 year results of a series of 500 cases of Primary TKR in which the All-Poly Monoblock Tibia had been used. All the patients had cross-legged sitting activity as part of their ADL, thus presumably generating significant pressures on the joint surfaces. Of the original 500 cases, we could follow up 434 cases. We report a 96% survival rate of the implant in this series. There was not a single aseptic plastic failure. The revisions required were due to infection, peri-prosthetic fracture, and instability. The message being conveyed in this paper is that the All-Poly Tibia is a very cost-effective solution in routine Primary TKRs, and is able to deliver excellent long-term results even in high stress situations like cross-legged sitting activity. It would offer a huge cost savings to the healthcare system if the Orthopaedic Surgeons start using this implant more frequently


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 323 - 323
1 Sep 2012
Li C Hussain A Joseph P Kamali A
Full Access

INTRODUCTION. One of the recent advances in the hard-on-hard hip arthroplasty is the development of a new material of diffusion hardened oxidised zirconium (DHOxZr). The DHOxZr material consists of a ceramic layer on the top surface which is supported by a thick oxygen diffusion hardened (DH) zone underneath. With the desired properties of metal substrate, ceramic surface and a gradient structure of the oxygen diffusion zone, the DHOxZr-on-DHOxZr bearing combination is expected to produce low wear and minimal metal ions. This can possibly address the concerns associated with metal hypersensitivity associated with metal on metal bearings and fracture risk associated with ceramics. The aim of this study was to evaluate the wear of DHOxZr-on-DHOxZr as a possible hard on hard bearing combination in hips. METHODS. Three pairs of 50 mm DHOxZr prototype hip joint devices, each consisting of a DHOxZr modular head and a DHOxZr liner were wear tested in a ProSim hip joint simulator under standard testing conditions used by the Implant Development Centre (IDC), Smith & Nephew, Leamington Spa for 5 million cycles (Mc). The flexion/extension was 30° and 15°. The internal/external rotation was ± 10°. The force was Paul-type stance phase loading, with a maximum load of 3 kN and a standard ISO swing phase load of 0.3 kN. The test frequency was 1 Hz. Gravimetric analysis was carried out at 0, 0.5, 1, 2, 3, 4 & 5 million cycles. The lubricant was new born calf serum with 2 g/l sodium azide concentration diluted with de-ionised water to achieve average protein concentration of 20 g/l. Lubricant was changed every 0.25Mc during the first million cycles of the test and at every 0.33 Mc from 1 to 5Mc. RESULTS. A biphasic wear pattern was observed for the DHOxZr on DHOxZr devices during the test, with a running in phase from 0–1 Mc and a steady state phase from 1–5 Mc. At a confidence level of 95%, the mean wear rate was 0.21 ±0.06 mm3/Mc during the running-in stage, and the wear rate was reduced to 0.01 ±0.03 mm3/Mc during the steady state for the device tested. The wear volume loss of the DHOxZr on DHOxZr devices was significantly lower than that generated by CoCrMo metal on metal (MoM) devices (p < 0.05) under identical simulator test conditions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 394 - 394
1 Sep 2012
Stoeckl B
Full Access

Introduction. Total femur implantation is a rare and challenging procedure in final revision surgery of hip and knee arthroplasties. Reports of this operation technique are even rare in literature. In this study we retrospectively analyse our patients with total femur implants. Material and Methods. Between October 2002 and February 2009 we implanted 27 total femurs in hip and knee revision surgery cases. We used the modular prosthesis system–Megasystem C® by Waldemar Link–in all cases. Our 22 female and 5 male patients had a mean age of 76 years (range 45–88). Indications for the procedure were loosening of megaprosthesis of the hip in 12 cases; 2 with massive distal migration, 1 with penetration into the knee joint and 1 after two step revision procedure. In 13 cases a periprosthetic indicated a total femur implanatation due to massive bone loss; 1 breakage of a long femoral stem, 5 fracture of osteosynthesis materials, 3 after prosthesis revisions and 1 pseudoarhrosis of femur and tibia after knee arthroplasty. We analysed perioperative complications, clinical status and result and further revision within follow up time. Results. We were able to examine 16 patients at follow up time. Eight patients were lost to follow up and 2 have been died; 1 after fulminant pulmonal embolia after operation and 1 four years postoperatively. One total femur had to be exchanged due to infection after 1 year. Perioperative complications occurred as follows: 1 massive blood transfusion, 1 peroneal palsy, 1 ulcus ventriculis bleeding, 1 thrombosis of vena suclavia and vena jugularis, 1 sigmaresection due to diverticulosis, 1 luxations of the hip, and 2 wound necrosis. In 3 caese a revision operation swas performed; 1multiple luxtion of the hip and due to infection of the total femur implant. The range of motion of the hip was 85 degrees (range 30–90) and knee 92 degrees (range 30–110). In nearly all cases we found a lengthening of the revised limb. The general outcome of the patients was. Ten patient were very satisfied, 2 statisfied and 2 fair due to pain persistence. Two patient were mobile with one crutch, 3 used two crutches and one was able to walk with a rollator. One patient was unable to walk due to diplegia after spine fracture. Conclusion. Total femur procedure in final revision arthroplasty has a high potential of perioperative risks but has shown good clinical and mobility results in our patient group. With the Megasystem C® by Link we had a save and good performance while operation of this difficult patient group


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1618 - 1625
1 Dec 2018
Gill JR Kiliyanpilakkill B Parker MJ

Aims

This study describes and compares the operative management and outcomes in a consecutive case series of patients with dislocated hemiarthroplasties of the hip, and compares outcomes with those of patients not sustaining a dislocation.

Patients and Methods

Of 3326 consecutive patients treated with hemiarthroplasty for fractured neck of femur, 46 (1.4%) sustained dislocations. Of the 46 dislocations, there were 37 female patients (80.4%) and nine male patients (19.6%) with a mean age of 83.8 years (66 to 100). Operative intervention for each, and subsequent dislocations, were recorded. The following outcome measures were recorded: dislocation; mortality up to one-year post-injury; additional surgery; residential status; mobility; and pain score at one year.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 693 - 702
1 Jun 2018
Jayakumar P Overbeek CL Vranceanu A Williams M Lamb S Ring D Gwilym S

Aims

Outcome measures quantifying aspects of health in a precise, efficient, and user-friendly manner are in demand. Computer adaptive tests (CATs) may overcome the limitations of established fixed scales and be more adept at measuring outcomes in trauma. The primary objective of this review was to gain a comprehensive understanding of the psychometric properties of CATs compared with fixed-length scales in the assessment of outcome in patients who have suffered trauma of the upper limb. Study designs, outcome measures and methodological quality are defined, along with trends in investigation.

Materials and Methods

A search of multiple electronic databases was undertaken on 1 January 2017 with terms related to “CATs”, “orthopaedics”, “trauma”, and “anatomical regions”. Studies involving adults suffering trauma to the upper limb, and undergoing any intervention, were eligible. Those involving the measurement of outcome with any CATs were included. Identification, screening, and eligibility were undertaken, followed by the extraction of data and quality assessment using the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) criteria. The review is reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria and reg

istered (PROSPERO: CRD42016053886).