Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 550 - 550
1 Sep 2012
Singisetti K Raju P Langton D Nargol A
Full Access

INTRODUCTION. A detailed clinical examination and investigations are required to evaluate the cause of persisting groin pain following a metal on metal (MoM) hip replacement. Adverse reaction to metallic debris (ARMD) is an emerging problem with MoM hip replacements. It is an umbrella term encompassing metallosis, pseudo-tumors and aseptic lymphocytic vasculitis associated lesions (ALVAL). The role of imaging in the diagnosis of this complex problem is still unclear. A study was undertaken to evaluate the efficacy of ultrasound in diagnosis of ARMD following a MoM hip replacement. METHODS. The study group included 35 patients with a clinical and histological diagnosis of ARMD, who had a preoperative ultrasound. All ultrasound procedures were performed on the anterior and lateral aspects of the painful hip with a high frequency probe of 9–13 MHz (Sonoline Antares – Siemens). RESULTS. All patients diagnosed with ARMD had abnormalities identified on ultrasound. Fluid inside the joint was noted in 30 out of 35 procedures (85.7 %). Fluid outside the joint was noted in 33 procedures (94.3 %). Amongst the patients with fluid outside the joint, 32 had iliopsoas and 30 had trochanteric bursitis. Echogenic reflections were noted in 31 out of 35 procedures (88.6 %). Considerable attenuation or absence of iliopsoas and gluteus tendon reflection was seen in many patients with echogenic fluid collections on the anterior and trochanteric aspects of hip. Progression of such changes was noted on further 5 patients, who had a repeat ultrasound within an interval of 3–6 months. 1 patient had a progression from anechogenic to echogenic joint effusion. DISCUSSION. Different radiological investigations including MRI scan have been used for evaluation of painful MoM hip arthroplasty. To our knowledge, this is the first study to demonstrate the efficacy of ultrasound in diagnosis of ARMD. Floating echogenic reflections and fluid collections around iliopsoas and gluteus medius/minimus tendons is highly suggestive of ARMD. Ultrasound is a cheap, non-invasive and dynamic investigation and has been shown to be reliable in diagnosis of ARMD


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 108 - 112
1 Jan 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Buckley L

Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions.

There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection.

The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants.

We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement.