Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 134 - 134
1 Sep 2012
Beaulé P White C Carsen S Rasuli K Doucette S
Full Access

Introduction. Modern cementless press fit stems rely on early fixation and stability for osteointegration and longterm success with early migration increasing the risk of failure. The Ein Bild Roentegen Analyse Femoral Component Analysis (EBRA-FCA) methods allow accurate measurement of femoral stem subsidence without the need for Tantalum markers. The degree of subsidence of femoral stems in the first two years has been shown to be highly predictive of failure when using the cut off value of 1.5 mm. We aimed to measure the early migration pattern of a titanium alloy, tapered, plasma and hydroxyapatite coated femoral stem and any factors associated with subsidence. Methods. Between January 2005-June 2007, 387 Accolade cementless femoral stems (Stryker, Allendale NJ) were implanted at our institution. Seventy-seven had a minimum of two years post operative follow up and a complete set of pre and postoperative radiographs for analysis. Our group inlcuded 45 females with a mean age of 71.4 years, and 32 males with a mean age of 68.5 years. The primary diagnosis was degenerative osteoarthritis in 71 patients, avascular necrosis in two, and post fracture in four patients. The average BMI was 27.1. We measured the canal index to assess bone quality and the canal calcar index to assess the proximal femoral morphology. Immediate postoperative radiographs were assessed for canal fill of the prosthesis and implantation varus/valgus angles. The EBRA-FCA software was used to obtain migration curves for each stem. Results. The mean follow up was 29.3months (24–48). The mean canal index was 0.55 (0.36–0.68) with a mean canal calcar index of 0.54 (0.39–0.79). The average canal fill index at the midpoint of the stem was <0.8 in 37 stems and >80 in 40 stems. The average subsidence at 24 months was 2 mm and this had risen to 2.4 mm by 36 months postoperatively. When analysed using a Kaplan Meier curve using 1.5 mm as an end point we found a survivorship of 63.4% (52.3–74.5) at 24 months and this had worsened to 41.6% (26.6–56.5) by 36 months. Multivariate and univariate regression analysis of measured variables did not reveal any significant hazard for any factor other than the larger stem sizes doing worse. Discussion. Although several cementless tapered stem designs have had an excellent track record, our migration analysis of the Accolade stem is somewhat concerning. Thirty three percent of stems had reached the 1.5 mm subsidence point by two years. This is of concern as work has previously shown this to predict failure of stems with aseptic loosening at ten years with an accuracy of 79%. If these stems go on to fail at the predicted rate this would represent an unacceptably high level of failure. Our data raises serious concerns about the overall clinical performance of this stem design due to poor initial stability and integration


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims

Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone.

Methods

Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 214 - 214
1 Sep 2012
Beaulé P White C Lopez-Castellaro J Kim P
Full Access

Introduction. Although femoral neck fractures remain a concern in short term failures for hip resurfacing, acetabular component position and fixation are increasingly being recognized as causes of mid term failures for hip resurfacing. This study aimed to evaluate the migration pattern of a cobalt chrome, beaded acetabular component for a metal on metal hip resurfacing. Methods. 130 patients underwent metal on metal hip resurfacing: 66 hips in 60 patients had sufficient films to be included in this analysis. Forty-eight patients were male and 12 were female, with a mean age of 50 (range, 32–66). Ninety-five percent of the procedures were performed for osteoarthritis. In all cases acetabular migration was measured both vertically and horizontally, on serial radiographs using the computer-assisted Ein Bild Röntgen Analyse method. A minimum of three comparable radiographs is necessary for calculating the migration curves. We scored medial migration as negative horizontal movement. Results. At a mean follow up 25.3 months (24–36 months), each hip had an average of 5.1 radiographs for analysis. 12.5% of the cups showed more than 1 mm migration in the medial-lateral axis and 45.3% more than 1 mm in the vertical axis. 23% of the cups showed a combined migration of greater than 2 mm in the observation period. Two of these cases required revision for aseptic loosening at 34 months. Discussion and Conclusion. Previous studies have shown EBRA to have an excellent sensitivity and positive predictive value for mid to long term cup failure. This data raises concern about the initial stability if this acetabular component. Continued follow-up is needed to monitor the longer term survival of this implant


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1307 - 1312
1 Oct 2019
Jacxsens M Schmid J Zdravkovic V Jost B Spross C

Aims

In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries.

Patients and Methods

Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 817 - 823
1 Jun 2011
Solomon LB Callary SA Stevenson AW McGee MA Chehade MJ Howie DW

We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51).

Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences.