Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 134 - 134
1 May 2016
Plachel F Heuberer P Schanda J Pauzenberger L Anderl W
Full Access

Background

The use of reverse total shoulder arthroplasty considerably increased since first introduced by Paul Grammont in the late 1980s. Over the past few years, results from several mid- and long-term clinical studies have demonstrated good functional outcomes and pain relief. However, several complications, especially inferior glenoid notching, and high revision rates were reported in the literature. Improvements in prosthesis design should contribute to a lower complication rate and lesser amount of glenoid erosion. Few studies have reported the clinical outcome andcomplications of Anatomical Shoulder Inverse/ Reverse Prosthesis. This study documents 2- and 6-year clinical and radiological results following reversed shoulder arthroplasty using this novel prosthesis.

Methods

We report the results for sixty-eight consecutive patients (seventy shoulders) with cuff tear arthropathy (CTA) treated with Anatomical Shoulder Inverse/Reverse Prosthesis between 2006 and 2008. Two groups were defined: (A) primary treatment and (B) revision. Clinical evaluation tools comprised Constant-Murley score (CS), range of motion, and a visual analog scale to assess pain. Radiographs (anteroposterior view in neutral position) were evaluated for notching and radiolucent lines. Any complications were recorded.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 17 - 17
1 May 2021
Widnall J Madan S Giles S Fernandes J
Full Access

Introduction

Recurrence in CTEV is not uncommon and as the child becomes older the foot in question is often stiffer and less amenable to the more traditional serial casting Ponseti method. Treatment of these recurrent CTEV feet with external fixators has been previously documented. We aim to present the Sheffield technique of an external circular frame with adjunctive hindfoot and midfoot osteotomies to correct relapsed CTEV and their associated Roye (outcome) scores.

Materials and Methods

Retrospective analysis of patient records from 1999 to 2019 were performed for those undergoing frame correction of CTEV. Patients were included if there was adjunctive foot osteotomies in the setting of CTEV frame correction and willingness to partake in retrospective Roye outcome scoring. The Roye score was sent out in the mail to parents asking for scoring of the current level of symptoms.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 42 - 42
1 Dec 2018
Glehr M Klim S Amerstorfer F Bernhardt G Sadoghi P Gruber G Leithner A Radl R
Full Access

Aim. Bone loss is a severe problem in septic revision total knee arthroplasty (RTKA). The use of porous coated metaphyseal sleeves is a promising treatment option for extended bone defects. The currently published mid-term results remain limited and no study has been focused exclusively on septic cases. Our aim was to determine the implant survivorship (with special focus on osseointegration) and the clinical and radiological mid-term outcome of metaphyseal sleeve fixation in septic RTKA surgery (minimum follow-up of 2 years). Method. Between January 2005 and September 2015, 57 patients underwent septic RTKA surgery using metaphyseal sleeves. In 56 patients (98,2 %) who underwent a total of 69 two stage revision procedures, clinical and radiological follow-up examinations were conducted. One patient (1,8 %) was lost to follow-up. The examinations included the American Knee Society Score (KSS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the SF-36 Health survey as well as radiographic measurement to determine if successful osseointegration had been achieved. Results. Thirteen knees (18.8%) had to be re-revised at the time of follow-up (mean 5.3 years, min. 2 – max. 11.2), all due to reinfection (Figure 1). We did not encounter any cases of aseptic loosening. The mean range of motion (92° ± 21°), SSS (7 ± 2), KSS (76 ± 19), WOMAC (70 ± 20), SF-36 MCS (55 ± 14) and SF-36 PCS (35 ± 9) have shown satisfying results. Conclusions. Metaphyseal sleeves have shown very promising mid-term results regarding clinical scores, osseointegration, and aseptic loosening. Our results are the first analysing the performance of metaphyseal sleeves in exclusively septic cases and show that they are a reliable fixation option in septic RTKA patients with severe bone loss


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 22 - 22
1 Apr 2019
Massari L Bistolfi A Grillo PP Causero A
Full Access

Introduction. Trabecular Titanium is a biomaterial characterized by a regular three-dimensional hexagonal cell structure imitating trabecular bone morphology. Components are built via Electron Beam Melting technology in aone- step additive manufacturing process. This biomaterial combines the proven mechanical properties of Titanium with the elastic modulus provided by its cellular solid structure (Regis 2015 MRS Bulletin). Several in vitro studies reported promising outcomes on its osteoinductive and osteoconductive properties: Trabecular Titanium showed to significantly affect osteoblast attachment and proliferation while inhibiting osteoclastogenesis (Gastaldi 2010 J Biomed Mater Res A, Sollazzo 2011 ISRN Mater Sci); human adipose stem cells were able to adhere, proliferate and differentiate into an osteoblast-like phenotype in absence of osteogenic factors (Benazzo 2014 J Biomed Mater Res A). Furthermore, in vivo histological and histomorphometric analysis in a sheep model indicated that it provided bone in-growth in cancellous (+68%) and cortical bone (+87%) (Devine 2012 JBJS). A multicentre prospective study was performed to assess mid-term outcomes of acetabular cups in Trabecular Titanium after Total Hip Arthroplasty (THA). Methods. 89 patients (91 hips) underwent primary cementless THA. There were 46 (52%) men and 43 (48%) women, with a median (IQR) age and BMI of 67 (57–70) years and 26 (24–29) kg/m2, respectively. Diagnosis was mostly primary osteoarthritis in 80 (88%) cases. Radiographic and clinical evaluations (Harris Hip Score [HHS], SF-36) were performed preoperatively and at 7 days, 3, 6, 12, 24 and 60 months. Bone Mineral Density (BMD) was determined by dual-emission X-ray absorptiometry (DEXA) according to DeLee &Charnley 3 Regions of Interest (ROI) postoperatively at the same time-points using as baseline the measureat 1 week. Statistical analysis was carried out using Wilcoxon test. Results. Median (IQR) HHS and SF-36 improved significantly from 48 (39–61) and 49 (37–62) preoperatively to 99 (96–100) and 76 (60–85) at 60 mo. (p≤0.0001). Radiographic analysis showed evident signs of bone remodelling and biological fixation, with presence of superolateral and inferomedial bone buttress, and radial trabeculae in ROI I/II. All cups resulted radiographically stable without any radiolucent lines. The macro-porous structure of this biomaterial generates a high coefficient of friction (Marin 2012 Hip Int), promoting a firm mechanical interlocking at the implant-bone interface which could be already observed in the operating room. BMD initially declined from baseline at 7 days to 6 months. Then, BMD slightly increased or stabilized in all ROIs up to 24 months, while showing evidence of partial decline over time with increasing patient' age at 60 months, although without any clinical significance in terms of patients health status or implant stability. Statistical significant correlations in terms of bone remodeling were observed between groups of patients on the basis of gender and age (p≤0.05). No revision or implant failure was reported. Conclusions. All patients reported significant improvements in quality of life, pain relief and functional recovery. Radiographic evaluation confirmed good implant stability at 60 months. These outcomes corroborate the evidence reported on these cups by orthopaedic registries and literature (Perticarini 2015 BMC Musculoskelet Disord; Bistolfi 2014 Min Ortop)


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 97 - 97
1 Apr 2018
Song S Liang H Bae D Yoo M Kim K Park C
Full Access

Introduction. Although total knee arthroplasty (TKA) in end-stage hemophilic arthropathy can reduce the severe joint pain and improve the functional disability, it is technically demanding. In addition, it has generally reported a high rate of complication including periprosthetic joint infection (PJI) and component loosening up to 20%. Although the Knee Society classification system of TKA complication was introduced, the complications of TKA in hemophilic arthropathy has not stratified using this classification system in previous articles to the best of our knowledge. The purpose of this study was to evaluate the mid-term outcomes and complications of TKA in hemophilic arthropathy. Methods. The study retrospectively reviewed 131 consecutive primary TKAs (102 patients) in single institute. The mean patient age was 41.0 years and mean follow-up time was 6.4 years. The clinical and radiographic results were evaluated. The complications were categorized according to the classification system of the Knee Society for TKA complications. Results. The average WOMAC score improved from 66.0 to 24.2. The average flexion contracture significantly decreased from 17.3° to 4.7°, but the average pre and postoperative maximum flexion did not differ (80.9 ° vs. 85.6°). The average mechanical axis was varus 5.2° preoperatively and valgus 0.3° postoperatively. The coronal position of femoral and tibial components and sagittal position of those components were within ±3° in 83.2%, 89.3%, 63.4%, and 73.3%. The complications occurred in 17 knees (13.0%). There were 7 bleeding and hemarthrosis. Five knees were treated with increased amounts of coagulation factor concentrate and two knees were treated with incision and drainage of hematoma. One medial collateral ligament injury of grade 2 required change of postoperative rehabilitation protocol and bracing. Two stiffness of grade 3 required unplanned admission and manipulation under anesthesia. Three deep PJI were treated with 2 stage revision TKA. There were 4 periprosthetic fractures. Three distal femur fractures were treated with open reduction and internal fixation for 3 knees. One patellar fracture was healed with conservative treatment. Conclusions. The mid-term results of TKA in end-stage hemophilic arthropathy were satisfactory with obtaining pain relief, improving function, and decreasing flexion contracture. Bleeding and PJI continues to be a major concern for TKA in patients with hemophilic arthropathy, and risk of periprosthetic fracture has to be taken into account for patient education and appropriate prevention. Level of evidence. Level IV


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 89 - 89
1 Apr 2018
Kim S Jung Y Park Y Chang G Lee H
Full Access

Purpose. The purpose of this study is to compare the mid-term outcomes between rotating platform(RP) and posterior cruciate substitute(PS) bearings in LCS-total knee arthroplasty (TKA). Methods. This is a prospective randomized matched-pairs case–control study of patients who underwent primary TKAs with a minimum 2 years follow-up. The inclusion criteria was degenerative arthritis, and exclusion criteria was arthritis other than degeneration, previous operations such as osteotomy, body mass index (BMI) over 30 kg/m. 2. The matching criteria were set as age, BMI, preoperative ROM, gender, and the Knee Society (KS) and Hospital for Special Surgery (HSS) scores. After 1:1 matching, 50 cases involved the LCS RP bearing system as group 1 and 50 cases involved LCS PS bearing system group as group 2. Clinical and radiographic outcomes were evaluated. Results. The overall survival was 100% at final follow up. There were no complications between groups, such as infection, dislocation of bearing. The postoperative ROM was 122.3° ± 9.3 in group 1, 121.2° ± 9.7 in group 2. The KSKS scores were 93.5±7.2 in group 1, 92.8±3.6 in group 2 at final follow up. The KSFS scores were 87.5±7.7 in group 1, 86.9±6.8 in group 2 at final follow up. The HSS scores were 93.1±8.8 in group 1, 91.7±6.1 in group 2 at final follow up. There was no statistical difference in Hospital for Special Surgery Scores (HSS), Knee Society Scores (KSS) score evaluations between groups. However, the improvement of KSS and HSS scores was faster in group 1, the final scores were achieved at 3 to 6 months in group 1, at 6 to 1 year in group 2. Moreover, the KSFS scores were improved continuously until 2 years follow up. The postoperative mechanical axis was found as 1.2° ± 1.2 in group 1, 0.9° ± 0.9 in group 2. There were no statistical differences between groups in radiological evaluations including radiolucent lines. Conclusion. This study demonstrated that the PS-LCS prosthesis could provide satisfactory performance compared with that of the RP-LCS prosthesis with minimum 2-year follow-up, however, there could be disadvantages in PS-LCS prosthesis due to more bone loss in box cut in femur


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 45 - 45
1 Dec 2017
Glehr M Klim S Sadoghi P Bernhardt G Leithner A Radl R Amerstorfer F
Full Access

Aim. One of the most challenging problems in total knee arthroplasty (TKA) is periprosthetic infection. A major problem that arises in septic revision TKA (RTKA) are extended bone defects. In case of extended bone defects revision prostheses with metaphyseal sleeves are used. Only a few studies have been published on the use of metaphyseal sleeves in RTKA - none were septic exclusive. The aim of our study was to determine the implant survival, achieved osseointegration as well as the radiological mid-term outcomes of metaphyseal sleeve fixation in septic two-stage knee revision surgery. Method. Clinical and radiological follow-up examinations were performed in 49 patients (25 male and 24 female). All patients were treated with a two-stage procedure, using a temporary non-articulating bone cement spacer. The spacer was explanted after a median of 12 weeks (SD 5, min. 1 – max. 31) and reimplantation was performed, using metaphyseal sleeves in combination with stem fixation. Bone defects were classified on preoperative radiographs using the Anderson Orthopaedic Research Institute (AORI) classification. During follow-up postoperative range of motion (ROM) was measured and radiographs were performed to analyse: (i) osseointegration (radiolucent lines and spot welds), (ii) leg alignment, (iii) patella tilt and shift. Results. All types of bone defects were found on the tibial (4× type 1, 7× type 2a, 26× type 2b, 9× type 3) as well as on the femoral side (1× type 1, 4× type 2a, 20× type 2b, 6× type 3). Mean follow-up time was 4.7 years (minimum 1 year). In total 12 knees (24.5%) had to be re-revised, all due to re-infection. We did not encounter any case of aseptic loosening. In 3 patients (6.8%) we detected an insufficient osseointegration, but no patient had to be re-revised due to only minimal or to the absence of symptoms and no clinical signs of loosening. The ROM (mean 93°, SD 20.6, min. 25° max. 125°) has shown very satisfying results at the time of follow-up. Malalignment was detected in 4 patients (10.3%), a patella tilt in 7 (19.4%) and a patella shift in 14 (48.3%). Conclusions. Metaphyseal Sleeves have shown very promising mid-term results regarding osseointegration and aseptic implant survival in RTKA with compromised metaphyseal bone stock. Our results indicate that they are a reliable fixation option in septic RTKA patients


Objectives. Total hip replacement is increasingly being conducted in younger and more active patients, so surgeons often use bearing surfaces with improved wear characteristics, such as ceramic on ceramic. The primary objective of this study was to determine if survivorship for a BIOLOX® delta ceramic on delta ceramic couple used with the PROCOTYL® L acetabular cup is significantly different from all other cementless cups in a large arthroplasty registry. The secondary objective of this study was to analyze patient reported outcomes measures (PROMs) of the subject cup with a minimum five year follow-up. Methods. Patient demographics and survivorship data was collected from the National Joint Registry of England, Wales, Northern Ireland, and the Isle of Man (NJR) database for all total hip replacements performed with the PROCOTYL® L cup used in combination with a delta-on-delta articulation, as well as for all other cementless cups. Survivorship data was compared for all revisions and cup revisions only and data was adjusted to exclude metal on metal articulations. The hazard ratio of the subject system to all cementless cups was also calculated with the Cox Proportional Hazards model. Patients with the subject components implanted for a minimum of five years completed Oxford Hip, EQ-5D, and EQ VAS score questionnaires. Results. The patient demographic data collected for the subject components and all cementless cups is provided in Figure 1. Six-year survivorship for the subject cup (98.6%) was similar to survivorship for all cementless cup revisions in the NJR database (98.5%), as seen in Figure 2. When the cup alone was revised, six-year survivorship of the subject cup (98.6%) and all NJR cementless cups (98.5%) was also similar. However, the subject cup survivorship remained at 98.6% from 4 to 6 years post-implantation, while survivorship for all cementless cups decreased slightly from years 4 to 6. The similarities between the revision risk of the subject system and all cementless cups in the NJR can be seen in the Cox Proportional Hazards model for revision risk ratios provided in Figure 3. Patients with the subject cup implanted for an average of 5.88 years reported Oxford Hip, EQ-5D, and EQ VAS scores of 39.60 ± 10.78, 0.801 ± 0.259, and 75.49 ± 19.25, respectively. Conclusions. The subject acetabular cup with a ceramic on ceramic articulation exhibited similar survivorship to all other cementless acetabular cups, excluding those with metal on metal bearings, in the NJR. Patients implanted with the subject system for an average of 5.88 years reported what are considered satisfactory Oxford Hip, EQ-5D, and EQ VAS scores. This survivorship and PROMs data is the first report of mid-term outcomes with the subject components


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 148 - 148
1 May 2016
Garcia-Rey E Garcia-Cimbrelo E
Full Access

Introduction. The use of screws is frequent for additional fixation, however, since some disadvantages have been reported a cup press-fit is desirable, although this can not always be obtained. Cup primary intraoperative fixation in uncemented total hip replacement (THR) depends on sex, acetabular shape, and surgical technique. We analyzed different factors related to primary bone fixation of five different designs in patients only diagnosed with osteoarthritis, excluding severe congenital hip disease and inflammatory arthritis, and their clinical and radiological outcome. Materials y Methods. 791 hips operated in our Institution between 2002 and 2012 were included for the analysis. All cases were operated with the same press-fit technique, and screws were used according to the pull-out test. Two screws were used if there was any movement after the mentioned manoeuvres. Acetabular and femoral radiological shapes were classified according to Dorr et al. We analyzed radiological postoperative cup position for acetabular abduction angle, the horizontal distance and the vertical distance. Cup anteversion was evaluated according to Widmer and the hip rotation centre according to Ranawat. Results. Screws were required in 155 hips (19.6%) and were more frequently used in women and patients with a type A acetabulum (p<0.001, p=0.021, respectively). There were no differences among the different cups evaluated. The need for screws was more frequent in hips with a smaller version of the cup and with a distance greater than 2 mm to the approximate femoral head centre from the centre of the prosthetic femoral head (p=0.022, 0.012, respectively). Adjusted multivariate analysis revealed that female patients (p<0.001, Odds Ratio (OR): 2.063; 95% Confidence Interval (CI) 1.409–3.020), cups with a smaller version (p=0.012, OR: 0.966, 95% CI 0.94–0.992), and a greater distance to the rotation hip center (p<0.005, OR: 1.695; 95% CI 1.173–2.450) had a higher risk for screw use. No hips needed revision for aseptic loosening. Conclusions. Cup press-fit depends on gender and surgical technique in hips without significant acetabular abnormalities or inflammatory arthritis. Contemporary uncemented cups provide similar primary fixation and mid-term outcome


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 149 - 149
1 May 2016
De Martino I Sculco P Galasso O Gasparini G
Full Access

Introduction. The optimal management of severe tibial and/or femoral bone loss in a revision total knee arthroplasty (TKA) has not been established. Reconstructive methods include structural or bulk allografts, impaction bone-grafting with or without mesh augmentation, custum prosthetic components, modular metal augmentations of prosthesis and tumor prosthesis. Recently metaphyseal fixation using porous tantalum cones (Zimmer, Warsaw, IN) has been proposed as alternative strategy for severe bone loss. Objectives. The purposes of this study were to determine the clinical and radiographic outcomes in patients who underwent revision knee arthroplasty with tantalum cones with a minimum of 5-year follow-up. Methods. From November 2005 to August 2008 a total of 26 porous tantalum metaphyseal cones were used to reconstruct severe tibial and/or femoral bone loss in 18 patients during revision TKA at a single institution. There were 12 females and 6 males with an average age of 73 years (range 55–84) at the time of revision. The mean clinical and radiographic follow-up was 6.3 years (range, 5–8). The reasons for revision were aseptic loosening (5 cases) and deep infection (13 cases). A Two stage procedure was used in all septic cases. According to the Anderson Orthopaedic Reseach Institute (AORI) bone defects classification all femoral and tibial defects were rated 2B and 3 (3 T2b, 9 T3, 3 F2b and 10 F3). A femoral cone was inserted in 6 patients, a tibial cone was inserted in 5, a double cone in 6 (femoral and tibial), and a triple cone in 1 (1 femoral and 2 tibial). A constrained condylar implant (LCCK, Zimmer, Warsaw) was inserted in 6 patients and a rotating hinge knee implants (RHK, Zimmer, Warsaw, IN) in 12 pateints. All patients were prospectively followed for clinical and radiographic evaluation preoperatively and postoperatively at 1, 3, 6 months, one year and yearly thereafter. Results. Knee Society knee scores improved from a mean of 31.3 points before surgery to 76.7 points at latest followup (p < 0.001). Knee Society function scores improved from a mean of 21.7 points before surgery to 65.4 points at latest followup (p < 0.001). The average flexion contracture was 6° and the average flection was 88°. At the time of the latest follow-up the average flexion contraction was 3° and the average flexion was 105°. No radiolucent lines were seen between the cones and the adjacent tibial and femoral bone at the latest follow-up. There was no evidence of loosening or migration of any implant at the time of the final follow-up. There have been two reoperations for recurrent infection (11%). Conclusions. Our experience demonstrates excellent clinical and radiographic mid-term outcomes and confirms that metaphyseal fixation with porous tantalum cones can be achieved. Long-term follow up and comparative studies are necessary


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 103 - 103
1 Jan 2013
Lee P Neelapala V O'Hara J
Full Access

Introduction. Perthes disease is associated with coxa breva, plana and magna, and a high riding prominent greater trochanter causing abductor shortening and weakness, leg shortening and extra-articular impingement. A trochanteric advancement with an infero-lateralizing sliding osteotomy of the proximal femur would lengthen femoral neck, improve abductor length and strength, relieve impingement and improve leg length. We assessed the mid-term outcomes for this procedure. Method. We included patients who underwent the operation by the senior author (JNOH) with more than 2 years follow-up. The osteotomies were performed under image intensifier guidance and fixed with blade plate or locking plates. We assessed functional scores, radiological changes in neck length, Tonnis grading for arthritis and evidence of progression in femoral head avascular necrosis, time interval for conversion to hip arthroplasty and associated complications. Results. Twenty four patients (25 hips) underwent the procedure at mean age of 18.7 years (range:9.3–38.8) with a mean follow-up of 5 years (range:2–13.8). At the last assessment, the mean Oxford Hip Score was 41.6 (range:58–27), Non-Arthritic Hip Score was 53.4 (range:25–77) and UCLA activity score was 4.2 (range:2–6). For changes in neck length, the mean “Head-centre-to-Greater-trochanteric-tip-distance” was 60 mm (range:43–78) compared to 39 mm (range:30–48) pre-operatively and the mean “Head-center-to-Lesser-trochanteric-tip-distance” was 54 mm (range:47–64) compared to 37 mm (range:31–41) pre-operatively. The mean Tonnis grade was 1.5 (range:1–3) compared to 1.3 (range:1–2) pre-operatively. Two patients underwent arthroplasty conversion at 2 and 13.8 years later. One patient needed head-neck debridement for impingement and 2 patients underwent trochanteric refixation for non-union. There was no progression in avascular necrosis of femoral head. Discussion. Symptomatic Perthes hip deformity in adolescents and young adults is difficult to treat with joint preserving surgery. The mid-term clinical, functional and radiological results for double proximal femur osteotomy are encouraging


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 43 - 43
1 Sep 2012
De Smet K
Full Access

The surgical treatment of young adults with end-stage hip disease has been a challenge. Inferior THA survival in the young, perceived advantages of hip resurfacing versus THA and advancements in tribology, led to the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA). To-date, thousands of such prostheses have been implanted worldwide in younger patients, yet little is known regarding long-term outcome. The only studies reporting greater than 10 year outcome come from designer centres with survivorship varying between 88.5–96% at 12 years. Arthroplasty Registries (AR) have reported less favourable survivorships with female gender and size having a negative effect on survival. In our independent hip resurfacing centre in Ghent, Belgium, a single surgeon has implanted more than 3500 HRA over more than 12 years. A cohort of 149 patients who received a Birmingham Hip Resurfacing (BHR) at a mean age of 50 years at surgery have now reached a minimum 10 years follow-up. The overall 12-year survival in these young adults is 93.1% (95% CI: 88.3–98.0), 99% in males and 87.3% in females. These survivorship data are superior to registry reported figures of THA amongst young patients and correspond well with previous reports from designer centres. The long-term survivorship and clinical outcome of the BHR are excellent in men, uninfluenced by preoperative diagnosis or age. However, survivorship in women is inferior and usually related to increased wear and reactions to metal debris. Malpositioning of components with associated wear-induced soft tissue fluid collections is the most frequent factor leading to failure of a HRA. In our experience, mid-term outcome following revision is good and complication and re-revision rates can be low. Surgical experience, early intervention in cases of mal-positioned implants, clinical use of ion levels, implantation of larger ceramic-on-ceramic THA femoral heads and patient education are factors in improving outcome and reducing complication and re-revisions following HRA revision


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 3 - 3
1 Jul 2016
Ramesh K Baumann A Makaram N Finnigan T Srinivasan M
Full Access

Despite the high success rates of Reverse Shoulder replacements, complications of instability & scapular notching are a concern. Factors reducing relative motion of implant to underlying bone which include lateral offset to centre of rotation, screw & central peg insertion angle and early osteo-integration are maximized in the Trabecular Metal Reverse total shoulder system. We present clinico-radiological outcomes over 72 months. Analysis of a single surgeon series of 140 Reverse total shoulder replacements in 135 patients was done. Mean age was 72(range 58– 87 yrs); 81 females: 54 males. Indications were Rotator cuff arthropathy {n= 88} (63%); Osteo-arthritis with dysfunctional cuff {n= 22}(15%); post-trauma{n=23} (15%); revision from hemiarthroplasty {n=3} (2.4%) and from surface replacement {n=4} (2.8%). All patients were assessed using pre-operative Constants and Oxford scores and clinical & radiographic reviews with standard X-Rays at 6 weeks, 3, 6,12 months and yearly thereafter. X rays included an AP view in 45 degrees of external rotation and modified axillary view. Inferior Scapular notching using the Nerot-Sirveaux grades and Peg Glenoid Rim Distance were looked into by a consultant musculoskeletal radiologist/ Orthopaedic surgeon/ Senior Fellow (post CCT) or a specialist Trainee (ST4 and above). Pain on the visual analogue scale decreased by 98% (9.1 to 0.8) (p<0.01). Constant score improved by 81.8% (12.4 to 68.1) (p<0.05), Oxford shoulder score by 76.7% (56 to 13) (p<0.05). 95.6% of Humeral stems had no radiolucent lines and 4.4% had < 2mm of lucency. Scapular notching was calculated using Sirveaux grades with Peg scapular base angle distance (PSBA) measurements on PACS with Siemens calibration (grade 1= 4 (2.8%); grade 2 =1; grade 3 =0; grade 4=0). 3.57% showed radiographic signs of scapular notching at 72 months. Range of Peg Glenoid Rim Distance was 1.66 to 2.31 cm. Power analysis showed 65 patients were needed to have an 80% power to detect relation of Peg Glenoid Rim Distance to Scapular notching. A likelihood ratio test from Logistic regression model to check correlation of Peg Glenoid Rim Distance to Scapular notching gave a p value of 0.0005. A likelihood ratio from Logistic regression gave a p value of 0.0004 for Infraglenoid Scapular spurs. Highest incidence of spurring was seen in Reverse Total Shoulder Replacements done for Trauma and lowest in patients who got the procedure for Osteoarthritis. Complications included two glenosphere revisions; two stitch abscesses and two Acromial fractures in patients who had a fall two years after the procedure. Improved surgical outcomes can be attributed to surgical technique and implant characteristics. Trabacular metal promotes early osteointegration which resists shearing action of Deltoid on Glenoid component. This allows early mobilisation. Deltoid split approach preserves integrity of Subscapularis and Acromial osteotomy and lateral clavicle excision improve exposure and prevent Acromion fracture. Positioning the Glenoid component inferiorly on the Glenoid decreases incidence of Scapular notching. Our mid-term validated outcomes are promising with only 3.57% Grade I/II radiographic signs of scapular notching. Long term studies (10 year follow ups) are necessary to confirm its efficacy


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1419 - 1427
3 Oct 2020
Wood D French SR Munir S Kaila R

Aims

Despite the increase in the surgical repair of proximal hamstring tears, there exists a lack of consensus in the optimal timing for surgery. There is also disagreement on how partial tears managed surgically compare with complete tears repaired surgically. This study aims to compare the mid-term functional outcomes in, and operating time required for, complete and partial proximal hamstring avulsions, that are repaired both acutely and chronically.

Methods

This is a prospective series of 156 proximal hamstring surgical repairs, with a mean age of 48.9 years (21.5 to 78). Functional outcomes were assessed preinjury, preoperatively, and postoperatively (six months and minimum three years) using the Sydney Hamstring Origin Rupture Evaluation (SHORE) score. Operating time was recorded for every patient.