Surgical repair of posterosuperior rotator cuff
tears has a poorer outcome and a higher rate of failure compared
with repairs of supraspinatus tears. In this prospective cohort
study 28 consecutive patients with an irreparable posterosuperior
rotator cuff tear after failed conservative or surgical treatment
underwent teres major tendon transfer. Their mean age was 60 years
(48 to 71) and the mean follow-up was 25 months (12 to 80). The
mean active abduction improved from 79° (0° to 150°) pre-operatively
to 105° (20° to 180°) post-operatively (p = 0.011). The mean active
external rotation in 90° abduction improved from 25° (0° to 70°)
pre-operatively to 55° (0° to 90°) post-operatively (p <
0.001).
The mean Constant score improved from 43 (18 to 78) pre-operatively
to 65 (30 to 86) post-operatively (p <
0.001). The median post-operative
VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to
5 (0 to 56) post-operatively (p <
0.001). In conclusion, teres major transfer effectively restores function
and relieves pain in patients with irreparable posterosuperior rotator
cuff tears and leads to an overall clinical improvement in a relatively
young and active patient group with limited treatment options. Cite this article:
We describe the clinical outcome of a technique of surgical augmentation of chronic
The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and
We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73° to 138°. The integrity of teres minor is essential for the recovery of external rotation and significantly influenced the Constant score. Five cases of aseptic loosening of the glenoid and seven of dissociation of the glenoid component were noted. This study confirms the promising early results obtained with the inverted prosthesis in the treatment of a cuff-tear arthropathy. It should be considered in the treatment of osteoarthritis with a
We describe 14 patients who underwent transfer of latissimus dorsi using a new technique through a single-incision. Their mean age was 61 years (47 to 76) and the mean follow-up was 32 months (19 to 42). The mean Constant score improved from 46.5 to 74.6 points. The mean active flexion increased from 119° to 170°, mean abduction from 118° to 169° and mean external rotation from 19° to 33°. The Hornblower sign remained positive in three patients (23%) as did the external rotation lag sign also in three patients (23%). No patient had a positive drop-arm sign at follow-up. No significant difference was noted between the mean pre- and postoperative acromiohumeral distance as seen on radiographs. An increased grade of osteoarthritis was found in three patients (23%). Electromyographic analysis showed activity of the transferred muscle in all patients.
We have studied cellular and vascular changes in different stages of full thickness tears of the rotator cuff. We examined biopsies from the supraspinatus tendon in 40 patients with chronic rotator cuff tears who were undergoing surgery and compared them with biopsies from four uninjured subscapularis tendons. Morphological and immunocytochemical methods using monoclonal antibodies directed against leucocytes, macrophages, mast cells, proliferative and vascular markers were used. Histological changes indicative of repair and inflammation were most evident in small sized rotator cuff tears with increased fibroblast cellularity and intimal hyperplasia, together with increased expression of leucocyte and vascular markers. These reparative and inflammatory changes diminished as the size of the rotator cuff tear increased. Marked oedema and degeneration was seen in large and
Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells. HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential.Aims
Methods
This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with
We have used Fourier transform infrared spectroscopy (FTIR) to characterise the chemical and structural composition of the tendons of the rotator cuff and to identify structural differences among anatomically distinct tears. Such information may help to identify biomarkers of tears and to provide insight into the rates of healing of different sizes of tear. The infrared spectra of 81 partial, small, medium, large and
We have undertaken an in vivo assessment of the tissue metabolism and cellular activity in torn tendons of the rotator cuff. Cellular oxygen consumption was measured in 13 patients undergoing mini-open repair of small, medium, large and
After establishing anatomical feasibility, functional reconstruction to replace the anterolateral part of the deltoid was performed in 20 consecutive patients with irreversible deltoid paralysis using the sternoclavicular portion of the pectoralis major muscle. The indication for reconstruction was deltoid deficiency combined with
We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and
Transfer of pectoralis major has evolved as the most favoured option for the management of the difficult problem of irreparable tears of subscapularis. We describe our experience with this technique in 30 patients divided into three groups. Group I comprised 11 patients with a failed procedure for instability of the shoulder, group II included eight with a failed shoulder replacement and group III, 11 with a
We have conducted a prospective study to assess the mid-term clinical results following arthroscopic repair of the rotator cuff. Patients were evaluated using the Constant score, subjective satisfaction levels and post-operative ultrasound scans. Of 115 consecutive patients who underwent arthroscopic repair of the rotator cuff at our institution, 102 were available for follow-up. The mean period of follow-up was for 35.8 months (24 to 73). The mean age of the patients was 57.3 years (23 to 78). There were 18 small (≤ 1 cm in diameter), 44 medium (1 cm to 3 cm in diameter), 34 large (3 cm to 5 cm in diameter) and six
Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and
We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation.
We treated 12 shoulders in ten patients with irreparable rotator-cuff tears by transfer of the latissimus dorsi. There were nine men and one woman. Their average age was 64.0 years and the average follow-up was 35.6 months (26 to 42). The results were excellent in four shoulders, good in four, fair in one, and poor in three. Active forward flexion improved from a preoperative average of 99° to a postoperative average of 135°. Osteoarthritic changes appeared in five shoulders and proximal migration of the humeral head progressed in six. EMG revealed that nine of the 12 transferred muscles showed activity which was synergistic with the supraspinatus on external rotation with abduction. We conclude that latissimus dorsi transfer can be effective in restoring shoulder function after
Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).Objectives
Methods
This study reports the clinical and sonographic
outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years
and aimed to determine factors associated with re-tear. A total
of 69 consecutive repairs were performed in 68 patients with a mean
age of 77 years (70 to 86). Constant-Murley scores were collected
pre-operatively and at one year post-operatively. The integrity
of the repair was assessed using ultrasound. Re-tear was detected
in 20 of 62 patients (32%) assessed with ultrasound. Age at operation We conclude that arthroscopic rotator cuff repair in patients
aged ≥ 70 years is a successful procedure. The gender and age of
the patient are important factors to consider when planning management. Cite this article:
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75)
underwent arthroscopic repair of the rotator cuff and simple tenotomy
of the long head of biceps tendon. At two years post-operatively,
ultrasound revealed that the tendon was inside the bicipital groove
in 43 patients (82.7%) and outside in nine (17.3%); in six of these
it was lying just outside the groove and in the remaining three
(5.8%) it was in a remote position with a positive Popeye Sign.
A dynamic ultrasound scan revealed that the tenotomised tendons
had adhered to the surrounding tissues (autotenodesis).The initial
condition of the tendon influenced its final position (p <
0.0005).
The presence of a Popeye sign was statistically influenced by the
pre-operative co-existence of supraspinatus and subscapularis tears (p
<
0.0001). It appears that the natural history of the tenotomised long head
of biceps tendon is to tenodese itself inside or just outside the
bicipital groove, while its pre-operative condition and coexistent
subscapularis tears play a significant role in the occurrence of
a Popeye sign.