Summary. Quantification of Three-Dimensional Computed Tomography (Q3DCT) is a reliable and reproducible technique to quantify and characterise ankle fractures with a posterior
Management of complex posterior
Abstract. Objectives. Ankle fractures have an incidence of around 90,000 per year in the United Kingdom. They affect younger patients following high energy trauma and, in the elderly, following low energy falls. Younger patients with pre-existing comorbidities including raised BMI or poor bone quality are also at risk of these injuries which impact the bony architecture of the joint and the soft tissues leading to a highly unstable fracture pattern, resulting in dislocation. At present, there is no literature exploring what effect ankle fracture-dislocations have on patients’ quality of life and activities of daily living, with only ankle fractures being explored. Methods. Relevant question formatting was utilised to generate a focused search. This was limited to studies specifically mentioning ankle injuries with a focus on ankle fracture-dislocations. The number of patients, fracture-dislocation type, length of follow up, prognostic factors, complications and outcome measures were recorded. Results. 939 fractures were included within the studies. Eight studies looked at previously validated foot and ankle scores, two primarily focused on the American Orthopaedic Foot and Ankle Society score (AOFAS), three on the Foot and Ankle Outcome Score (FAOS), and one study on the Olerud–Molander Score (OMAS). Patient, injury, and management factors were identified as being associated with poorer clinical outcomes. Conclusions. Not only are age and BMI a risk factor for posttraumatic osteoarthritis but they were also identified as prognostic indicators for functional outcome in this review. Patients sustaining a concurrent fracture-dislocation were found to have poorer clinical outcomes, and the timing and success of reduction further influenced outcomes. This review found that the quality of reduction was directly related to the patients’ functional outcomes post-follow up, and the risk of developing posttraumatic osteoarthritis, which was more frequent in patients sustaining Bosworth fractures, posterior
Introduction and Objective. Joint
Introduction and Objective. Ankle fractures are common and affect young adults as well as the elderly. An unstable ankle fracture treatment typically involves surgical fixation, immobilisation, and modified weight-bearing for six weeks. Non-weight bearing (NWB) cast immobilisation periods were used to protect the soft tissue envelope and osteosynthesis. This can have implications on patient function and may reduce independence, mobility and return to work. Newer trends in earlier mobilisation compete with traditional NWB doctrine, and weak consensus exists as to the best postoperative strategy. The purpose of this trial is to investigate the safety and efficacy of immediate weight-bearing (IWB) and range of motion (ROM) exercise regimes following ORIF of unstable ankle fractures with a particular focus on functional outcomes and complication rates. Materials and Methods. A pragmatic randomised controlled multicentre trial, comparing IWB in a walking boot and ROM within 24 hours versus non-weight-bearing (NWB) and immobilisation in a cast for six weeks, following ORIF of all types of unstable adult ankle fractures (lateral
The ankle radiograph is a commonly requested investigation as the ankle joint is commonly injured. Each radiograph exposes 0.01 mSv of radiation to the patient that is equivalent to 1.5 days of natural background radiation [1]. The aim of the clinical audit was to use the Ottawa Ankle Rule to attempt to reduce the number of ankle radiographs taken in patients with acute ankle injuries and hence reduce the dose of ionising radiation the patient receives. A retrospective audit was undertaken. 123 ankle radiograph requests and radiographs taken between May and July 2018 were evaluated. Each ankle radiograph request including patient history and clinical examination was graded against the Ottawa Ankle Rule. The rule states that 1 point(s) indicates radiograph series; (1)
Summary. Syndesmotic malreduction or failure to restore fibular length are the leading causes for early reoperation after ankle fracture surgery. Anatomic fracture reduction and congruent ankle mortise can be achieved in the majority of cases following revision surgery. Introduction. The goal of ankle fracture surgery is to restore anatomical congruity. However, anatomic reduction is not always achieved, and residual talar displacement and postoperative malreduction predispose a patient to post-traumatic arthritis and poor functional outcomes. The present study aimed to determine the most common surgical errors resulting in early reoperation following ankle fracture surgery. Patients & Methods. We performed a chart review to determine the most common types of malreductions that led to reoperation within the first week following ankle fracture surgery. From 2002 to 2011, we identified 5123 consecutive ankle fracture operations in 5071 patients. 79 patients (1.6%) were reoperated on due to malreduction (residual fracture displacement > 2mm) detected in postoperative radiographs. These patients were compared with an equal number of age- and sex-matched control patients. Surgical errors were classified according to the anatomical site of malreduction: fibula, medial malleolus, posterior malleolus, Chaput-Tillaux fragment, and syndesmosis. Problems related to syndesmotic reduction or fixation were further divided into four categories: malreduction of the fibula in the tibiofibular incisura due to malpositioning of a syndesmotic screw, persistent tibiofibular widening (TFCS > 6 mm), positioning of a syndesmotic screw posterior to the posterior margin of the tibia, and unnecessary use of a syndesmotic screw. Results. The mean patient age was 44 years (18 to 80), and 49% were women. There were no differences between the groups regarding diabetes, tobacco use, peripheral vascular disease, or alcohol abuse. The most common indication for reoperation was syndesmotic malreduction (47 of 79 patients; 59%). Other frequent indications for reoperation were fibular shortening and malreduction of the medial malleolus. We identified four main types of errors related to syndesmotic reduction or fixation, the most common being fibular malreduction in the tibiofibular incisura. The most commonly combined errors were malreductions of the fibula and syndesmosis, which occurred together in 16 of 79 patients (20%). Fracture-dislocation (p = 0.011), fracture type (p = 0.001), posterior
Total ankle replacement (TAR) is increasingly used in the treatment of end-stage ankle arthropathy, but much debate exists about the clinical result. The goals of present study are: 1) to provide an overview of the clinical outcome of 58 TAR's in a single centre and 2) to assess the association between radiological characteristics and clinical outcome. We reviewed a prospective included cohort of 58 TAR's in 54 patients with a mean age of 66.9 (range 54–82) and a mean follow-up of 21.6 months (range 1.45–66.0). The TAR's where performed by a single surgeon in a single centre (MUMC) between 2010 and 2015, using the CCI ankle replacement. A standard surgical protocol and standardized post-op rehabilitation was used. Patients were followed-up pre-op and at 1 day, 6 weeks, 3–6–12 months and yearly thereafter post-op. The AOFAS and range of motion (ROM) were assessed and all complications, re-operations and the presence of pain were recorded. Radiographic assessment consisted of the estimation of prosthesis alignment, migration, translation and radiolucent lines using the Rippstein protocol (1). The clinical outcome was compared with a systematic review of TAR outcome. Ten intra-operative complications occurred and 9 were
The posterolateral approach to ankle joint is well suited for ORIF of posterior
Talar neck fractures are associated with high complication rates with significant associated morbidity. Adequate exposure and stable internal fixation remains challenging. We investigated the anterior extensile approach for exposure of these fractures and their fixation by screws introduced through the talo-navicular articulation. We also compared the quality and quantity of exposure of the talar neck obtained by this approach, with the classically described medial/lateral approaches. An anterior approach to the talus between the tibialis anterior and the extensor hallucis tendons protecting both the superficial and deep peroneal nerves was performed on 5 fresh frozen cadaveric ankles . The surface area of talar neck accessible was measured using an Immersion Digital Microscribe and analysed with Rhinoceros 3D graphics package. Standard antero-medial and antero –lateral approaches were also carried out on the same ankles, and similar measurements taken. Seven talar neck fractures underwent operative fixation using the anterior approach with parallel cannulated screws inserted through the talo-navicular joint. 3D mapping demonstrated that the talar surface area visible by the anterior approach (mean 1200sqmm) is consistently superior to that visible by either the medial or lateral approaches in isolation or in combination. Medial
Anatomical atlases document safe corridors for placement of wires when using fine-wire circular external fixation. The furthest posterolateral corridor described in the distal tibia is through the fibula. This limits the crossing angle and stability of the frame. In this paper we describe a new, safe Retro-Fibular Wire corridor, which provides greater crossing angles and increased stability. In a cadaver study, 20 formalin-treated legs were divided into two groups. Wires were inserted into the distal quarter of the tibia using two possible corridors and standard techniques of dissection identified the distance of the wires from neurovascular structures. In both groups the posterior tibial neurovascular bundle was avoided. In group A the peroneal artery was at risk. In group B this injury was avoided. Comparison of the groups showed a significant difference (p <
0.001). We recommend the Retro-Fibular wire technique whereby wires are inserted into the tibia mid-way between the posteromedial border of the fibula and the tendo Achillis, at 30° to 45° to the sagittal plane, and introduced from a posterolateral to an anteromedial position. Subsequently, when using this technique in 30 patients, we have had no neurovascular complications or problems relating to tethering of the peroneal tendons.
We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the radial head in a sawbone model. The outcome measurements were the quality of the reduction, and stability. A total of 96 fractures was created. Six surgeons were involved in the study and each reconstructed 16 fractures with 1.6 mm fine-threaded wires (Fragment Fixation System (FFS)), T-miniplates, 2 mm miniscrews and 2 mm Kirschner (K-) wires; four fractures being allocated to each method using a standard reconstruction procedure. The quality of the reduction was measured after definitive fixation. Biomechanical testing was performed using a transverse plane shear load in two directions to the implants (parallel and perpendicular) with respect to ultimate failure load and displacement at 50 N. A significantly better quality of reduction was achieved using the FFS wires (Tukey’s The ultimate failure load was similar for the FFS wires (parallel, 196.8 N ( The fixation of a standard Mason type-III fracture in a sawbone model using the FFS system provides a better quality of reduction than that when using conventional techniques. There was a significantly better stability using FFS implants, miniscrews and K-wires than when using miniplates.
External fixation of distal tibial fractures is often associated with delayed union. We have investigated whether union can be enhanced by using recombinant bone morphogenetic protein-7 (rhBMP-7). Osteoinduction with rhBMP-7 and bovine collagen was used in 20 patients with distal tibial fractures which had been treated by external fixation (BMP group). Healing of the fracture was compared with that of 20 matched patients in whom treatment was similar except that rhBMP-7 was not used. Significantly more fractures had healed by 16 (p = 0.039) and 20 weeks (p = 0.022) in the BMP group compared with the matched group. The mean time to union (p = 0.002), the duration of absence from work (p = 0.018) and the time for which external fixation was required (p = 0.037) were significantly shorter in the BMP group than in the matched group. Secondary intervention due to delayed healing was required in two patients in the BMP group and seven in the matched group. RhBMP-7 can enhance the union of distal tibial fractures treated by external fixation.