Introduction. Total ankle replacement (TAR) is surgically complex;
Introduction. Torsional
Background. The purpose of this study was to analyze the effect of femorotibial alignment (FTA), femoral and tibial component alignment, correction of
Femoral shaft fractures are fairly common injuries in paediatric age group. The treatment protocols are clear in patients of age less than 4 years and greater than 6 years. The real dilemma lies in the age group of 4–6 years. The aim of this study is to find whether a conservative line should be followed, or a more aggressive surgical intervention can provide significantly better results in these injuries. This study was conducted in a tertiary care hospital in Bhubaneswar, India from January 2020 to March 2021. A total of 40 patients with femur shaft fractures were included and randomly divided in two treatment groups. Group A were treated with a TENS nail while group B were treated with skin traction followed by spica cast. They were regularly followed up with clinical and radiological examination to look out for signs of healing and any complications. TENS was removed at 4–9 months’ time in all Group A patients. Group A patients had a statistically significant less hospital stay, immobilisation period, time to full weight bearing and radiological union. Rotational malunions were significantly lower in Group A (p-value 0.0379) while there was no statistically significant difference in angular malunion in coronal and sagittal plane at final follow up. Complications unique to group A were skin necrosis and infection. We conclude that TENS is better modality for treatment of shaft of femur fractures in patients of 4–6 years age as they significantly reduce the hospital stay, immobilization period and rotational
The increasing incidence of periprosthetic femoral fractures (PFF) after total hip arthroplasty presents growing concerns due to challenges in treatment and increased mortality. PFF are often observed when the prosthesis is implanted in varus, especially with blade-type stems. To help elucidate its impact on the PFF risk, the specific research question is: What is the effect of misalignment of a blade-type stem (resulting in down-sized prosthesis) on 1)the distribution and magnitude of cortical stresses and 2)implant-bone micromotion. We developed two finite element models consisting of an average female femur implanted within a generic blade-type stem prosthesis, (i)in neutral alignment, and (ii)oriented in 5° of varus, coupled with corresponding down-sizing of the prosthesis. Each model consisted of 1.1million elements, while the average mesh length at the implant-bone interface was 0.4mm. Elastic moduli of 15GPa(cortex), 150MPa(trabecular bone), and 121GPa(implant), and Poisson's ratio of 0.3 were assumed. The distal end was fixed and the interface was defined as a surface-to-surface contact with friction coefficients (dynamic 0.3; static 0.4). Walking and stair-climbing were simulated by loading the joint contact and muscle forces after scaling to the subjects’ body weight. The peak von Mises stress and the average stress within the surface having 1cm diameter and the center at where the peak stress occurred at each contacting area, the interfacial micromotion along medial, lateral side were analyzed. For statistical analysis, two-tailed t-test was performed between the neutral and varus cases over four loading cycles with significance level of p<0.05.INTRODUCTION
METHOD
Introduction. Coronal
This study aimed to examine the effect of high tibial osteotomy (HTO) on the ankle and subtalar joints via analysis of static radiographic alignment. We hypothesised that surgical alteration of the alignment of the proximal tibia would result in compensatory distal changes. 35 patients recruited as part of the wider Biomechanics and Bioengineering Centre Versus Arthritis HTO study between 2011 and 2018 had pre- and postoperative full-length weightbearing radiographs taken of their lower limbs. In addition to standard alignment measures of the limb and knee (mechanical tibiofemoral angle, Mikulicz point, medial proximal tibial angle), additional measures were taken of the ankle/subtalar joints (lateral distal tibial angle, ground-talus angle, joint line convergence angle of the ankle) as well as a novel measure of stance width. Results were compared using a paired T-test and Pearson's correlation coefficient. Following HTO, there was a significant (5.4°) change in subtalar alignment. Ground-talus angle appeared related both to the level of
Introduction. Patients undergoing total knee arthroplasty (TKA) with end-stage osteoarthritis of knee have secondary foot and ankle pathology. Some compensatory changes occur at ankle and subtalar joint secondary to
Introduction. Limb deformity is usually assessed clinically assisted by long leg alignment radiographs and further imaging modalities (MRI and CT). Often decisions are made based on static imaging and simple gait interpretation in clinic. We have assessed the value of gait lab analysis in surgical decision making comparing surgical planning pre and post gait lab assessment. Materials & Methods. Patients were identified from the local limb reconstruction database. Patients were reviewed in the outpatient clinic and long leg alignment radiographs and a CT rotational limb profile were performed. A surgical plan was formulated and documented. All patients then underwent a formal gait lab analysis. The gait lab recommendations were then compared to the initial plan. Results. Twelve patients (8 female) with mean age of 14 (range 12–16) were identified. Nine were developmental torsional
Tibiotalocalcaneal arthrodesis (TTCA) is a salvage procedure to functionally block the ankle and subtalar joints to treat severe ankle and hindfoot disease. Complication rates range between 20-40%, with below-knee amputation rate 1.5-19%. The heterogeneous patient cohort and indication(s) for surgery make post-operative outcomes difficult to predict. Consulting patients about potential pain and functional outcomes is difficult. When researching this area commonly, PROM data is used, less frequently functional objective measures like the 2-minute-walk-test (2MWT) are used. The aim was to compare the PROMs and objective outcomes between patients who underwent TTCA and BKA. Fifty-two patients underwent a TTCA using an intramedullary hindfoot nail. Indications for TTCA, post-traumatic OA, failed arthrodesis and
Constrained implants with intra-medullary fixation are expedient for complex TKA. Constraint is associated with loosening, but can correction of deformity mitigate risk of loosening?. Primary TKA's with a non-linked constrained prosthesis from 2010-2018 were identified. Indications were ligamentous instability or intra-medullary fixation to bypass stress risers. All included fully cemented 30mm stem extensions on tibia and femur. If soft tissue stability was achieved, a posterior stabilized (PS) tibial insert was selected. Pre and post TKA full length radiographs showed. i. hip-knee-ankle angles (HKAA). ii. Kennedy Zone (KZ) where hip to ankle vector crosses knee joint. 77 TKA's in 68 patients, average age 69.3 years (41-89.5) with OA (65%) post-trauma (24.5%) and inflammatory arthropathy (10.5%). Pre-op radiographs (62 knees) showed varus in 37.0%. (HKAA: 4. o. -29. o. ), valgus in 59.6% (HKAA range 8. o. -41. o. ) and 2 knees in neutral. 13 cases deceased within 2 years were excluded. Six with 2 year follow up pending have not been revised. Mean follow-up is 6.1 yrs (2.4-11.9yrs). Long post-op radiographs showed 34 (57.6%) in central KZ (HKKA 180. o. +/- 2. o. ). . Thirteen (22.0%) were in mechanical varus (HKAA 3. o. -15. o. ) and 12 (20.3%) in mechanical valgus: HKAA (171. o. -178. o. ). Three failed with infection; 2 after ORIF and one with BMI>50. The greatest post op varus suffered peri-prosthetic fracture. There was no aseptic loosening or instability. Only full-length radiographs accurately measure alignment and very few similar studies exist. No cases failed by loosening or instability, but PPF followed persistent
Introduction. Intraoperative assessment of coronal alignment is important when performing corrective osteotomies around the knee and ankle, limb lengthening and trauma surgery. The Joint Angle Tool (JAT) provides surgeons with information about the anatomic and mechanical axes intraoperatively based on true anteroposterior radiographs. Aim: Presentation of the JAT, a low-cost goniometer for intraoperative assessment of the lower limb alignment. Materials and Methods. The JAT consists of pre-printed joint orientation angles of the anatomic and mechanical axis including normal variations on a plastic sheet. It is placed on the screen of the image intensifier after obtaining a true anterior-posterior image. The pre-printed joint orientation angles can intraoperatively assist the surgeons in achieving the pre-planned axis correction. Here, its feasibility is demonstrated in four cases. Results. Here, we present the intraoperative use of JAT in four cases:. 77 mm femoral bone transport due to non-union utilizing a bone transport nail,. distal femoral osteotomy correcting coronal and torsional
Introduction. Active robotics for total knee Arthroplasty (TKA) uses a CAD-CAM approach to plan the correct size and placement of implants and to surgically achieve planned limb alignment. The TSolution One Total Knee Application (THINK Surgical Inc., Fremont, CA) is an open-implant platform, CT-based active robotic surgical system. A multi-center, prospective, non-randomized clinical trial was performed to evaluate safety and effectiveness of robotic-assisted TKA using the TSolution One Total Knee Application. This report details the findings from the IDE. Methods. Patients had to be ≥ 21 years old with BMI ≤ 40, Kellgren-Lawrence Grade ≥ 3, coronal deformity ≤ 20°, and sagital flexion contracture ≤ 15° to participate. In addition to monitoring all adverse events (AE), a pre-defined list of relevant major AEs (medial collateral ligament injury, extensor mechanism disruption, neural deficit, periprosthetic fracture, patellofemoral dislocation, tibiofemoral dislocation, vascular injury) were specifically identified to evaluate safety. Bleeding complications were also assessed.
The use of shorter humeral stems in reverse shoulder arthroplasty has been reported as safe and effective. Shorter stems are purported to be bone preserving, easy to revise, and have reduced surgical time. However, a frequent radiographic finding with the use of uncemented short stems is stress shielding. Smaller stem diameters reduce stress shielding, however, carry the risk of varus or valgus
Background. Authors sought to determine the degree of lateral condylar hypoplasia of distal femur was related to degree of valgus
INTRODUCTION. To test whether there are differences in postoperative mechanical and component alignment, and in functional results, between conventional, navigated and patient-specific total knee arthroplasties in a low-volume centre?. MATERIAL AND METHODS. Retrospective cohort study of 391 patients who received conventional, navigated or patient- specific primary cemented TKA in a low-volume hospital. RESULTS. The risk of mechanical alignment outliers was 89% lower in the navigated group compared to the conventional TKA group. There was a 63% lower risk of femoral component
Background. Coronal
Introduction. Persistent patellofemoral (PF) pain is a common postoperative complication after total knee arthroplasty (TKA). In the USA, patella resurfacing is conducted in more than 80% of primary TKAs [1], and is, therefore, an important factor during surgery. Studies have revealed that the position of the patellar component is still controversially discussed [2–4]. However, only a limited number of studies address the biomechanical impact of patellar component
Introduction. In our institution, we started to perform THA with SuperPATH approach, including preservation of soft tissue around the hip (James Chow et al. Musculoskelet Med 2011) since July 2014, aiming for fast recovery and prevention of hip dislocation. For minimally-invasive approaches, however, there have been a few reports on