Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 53 - 53
1 Apr 2017
Goubran A McHale S Steinlechner C
Full Access

Background

Aseptic loosening of cemented femoral stems results from migration of wear particles along the bone-cement interface, producing a foreign body reaction. After cement insertion, blood back pressure can disrupt the bone-cement interface, enabling this spread of wear particles. Our study investigates whether altering timing and speed of stem insertion can reduce this risk.

Methods

We inserted mock “C-Stem” femoral components (De Puy-Synthes), using Smartset HV cement (De Puy-Synthes) into artificial femora, fitted with proximal and distal pressure transducers. Cement insertion began two, three or four minutes after mixing. Cement pressures were then allowed to settle for one minute and the stems were then inserted over durations of 25, 60 or 90 seconds.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 28 - 28
11 Apr 2023
Wither C Lawton J Clarke D Holmes E Gale L
Full Access

Range of Motion (ROM) assessments are routinely used during joint replacement to evaluate joint stability before, during and after surgery to ensure the effective restoration of patient biomechanics. This study aimed to quantify axial torque in the femur during ROM assessment in total hip arthroplasty to define performance criteria against which hip instruments can be verified. Longer term, this information may provide the ability to quantitatively assess joint stability, extending to quantitation of bone preparation and quality. Joint loads measured with strain-gaged instruments in five cadaveric femurs prepared using posterior approach were analysed. Variables such as surgeon-evaluator, trial offset and specimen leg and weight were used to define 13 individual setups and paired with surgeon appraisal of joint tension for each setup. Peak torque loads were then identified for specific motions within the ROM assessment. The largest torque measured in most setups was observed during maximum extension and external rotation of the joint, with a peak torque of 13Nm recorded in a specimen weighing 98kg. The largest torque range (19.4Nm) was also recorded in this specimen. Other motions within the trial reduction showed clear peaks in applied torque but with lower magnitude. Relationships between peak torque, torque range and specimen weight produced an R2 value greater than 0.65. The data indicated that key influencers of torsional loads during ROM were patient weight, joint tension and limb motion. This correlation with patient weight should be further investigated and highlights the need for population representation during cadaveric evaluation. Although this study considered a small sample size, consistent patterns were seen across several users and specimens. Follow-up studies should aim to increase the number of surgeon-evaluators and further vary specimen size and weight. Consideration should also be given to alternative surgical approaches such as the Direct Anterior Approach


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 28 - 28
1 Mar 2021
Bruce D Murray J Whitehouse M Seminati E Preatoni E
Full Access

Abstract. Objectives. 1. To investigate the effect of revision total knee replacement (TKR) on gait kinematics in patients with a primary TKR and instability.2. To compare gait kinematics between patients with a well-functioning TKR and those with a primary TKR and symptoms of instability. Methods. This single-centre observational study is following patients who have had a revision TKR due to knee instability. Data was collected pre- and post-operatively at 8–12 week follow-up. The data was compared to a control group of 18 well-functioning TKR patients. Kinematic gait data was collected during routine clinics using a treadmill-based infrared 3D system (Vicon, Oxford, UK) and a published lower limb marker-set. Patients performed 15 strides at three different speeds: 0.6mph, self-selected, and a ‘slow walk’ normalised to leg length (Froude number 0.09). PROMs questionnaires were collected. NHS ethical approval was obtained. Results. Data was collected for 18 well-functioning TKR patients and 8 revision TKR patients pre- and post-operatively, but only 5 could walk at the normalised speed. When walking at a normalised speed (Froude 0.09), patients with a TKR with instability had reduced range of knee flexion (52° (sd 14)) compared to those with a well-functioning TKR (59° (sd 11)). Short term follow-up after a revision TKR operation demonstrated a stiffer knee (45° (sd 12)). However, those with revision TKR had a more flexed knee during stance phase. Conclusions. At short-term follow-up, this cohort of revision TKR patients appear to have reduced flexion range, while remaining more flexed during stance. This may represent a less efficient gait pattern, which may also adversely affect the implant[1]. Longer term follow-up may demonstrate whether this normalises with post-operative rehabilitation. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 98 - 98
1 Dec 2020
Çağlar C
Full Access

The laterjet procedure is an important option in both primary and revision surgeries, especially in anterior shoulder instabilities that progress with glenoid bone loss. 12 patients who had a history of unsuccessful arthroscopic bankart repair and who underwent laterjet procedure in Ankara Atatürk Research and Training Hospital between 2013 and 2017 were included in the study and the patients were evaluated retrospectively. The mean age of the patients was calculated as 27.7 (range 21 to 38 years). Rowe and Walch-Duplay scores and operated shoulder (OS)-healthy shoulder (HS) range of motion (ROM) measurements were used to evaluate patients clinically and functionally. The mean follow-up time of the patients was calculated as 5.5±1.8 years. Firstly, no dislocation history was recorded in any patient afer the laterjet procedure. The mean Rowe score was calculated as 82.5 (range 60–100). Accordingly, 8 patients had excellent result, 3 patients had good result and 1 patient had fair result. The mean Walch-Duplay score was 81.4 (range 55–100). It was determined as excellent result in 6 patients, good result in 4 patients and fair result in 2 patients. Another data, joint ROM of the OS-HS of patients are shown in the table. There was some limitation in OS compared to the HS. p<0.05 value was accepted as statistically significant. While there was a statistically significant difference in external rotation (OS:35.2º, HS:56.4º)(p=0.003), internal rotation (OS:65.7º, HS:68.1º)(p=0.008) and flexion (OS:171.2º, HS:175.9º)(p=0.012) degrees but there was no statistically significant difference in abduction degrees (OS:164.3º, HS:170.4º) (p=0.089). In radiological evaluation, partial graft resorption was detected in 1 patient, but it was asymptomatic. The osteoarthritis which is one of the complications of laterjet procedure, was not detected radiologically. There are some limitations of the study. Firstly, it is a retrospective study. Secondly, the demographic features of the patients such as age, gender, profession and dominant hand are excluded. Thirdly, the mean follow-up time is not too long. Finally, some of the scales filled in are based on the patient's declaration, which may not yield sufficient objective results. In conclusion, the laterjet procedure is a suitable and reliable technique even for revision surgery in the treatment of anterior shoulder instability. It gives positive results in terms of shoulder stability and function. The major disadvantage was found to be the limitation of external rotation. Longer follow-up is needed for another outcomes and late complications, such as osteoarthritis. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 42 - 42
1 Mar 2013
Johnson-Lynn S Roy S McCaskie A Birch M
Full Access

Degree of early integration of titanium alloy implants into bone is an important predictor of long term implant success in arthroplasty. The correlation between observations on early cell adhesion and the ability of modified surfaces to affect osseointegration of implants in in vivo models is unclear. We hypothesised that observation of increased focal adhesion complexes in early cultures of osteoblasts would correlate with increased osseointegration of treated implants in an animal model. Longer term culture of rat osteoblasts for alkaline phosphatase activity indicated that cells cultured on the 9V treated surfaces were displaying greater alkaline phosphatase activity at 14 days. Bone nodule formation at 28 days demonstrated a trend towards smaller area of bone nodules on the surfaces treated at 9V then those treated at 3V and 5V. A rat model was employed for testing mechanical push-out strength of experimental implants and demonstrated a trend towards increased yield strength of the bone-implant interface for implants treated at 3V180s and 5V180s. Histomorphometry was performed and no statistically significant differences in percentage area of contact with mineralised bone matrix were seen, although there was a trend for greater mineralised matrix contact on the polished and 9V180s treated implants. Previous experiments demonstrated cells on the 9V treated surfaces were well spread and had significantly increased size and number of focal adhesions. This was regarded as indicating more successful cell adhesion. The above results demonstrate that this early trend disappeared in longer term culture did not persist in experiments in an animal model


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1184 - 1188
1 Nov 2002
Bushell AJ Klenerman L Taylor S Davies H Grierson I Helliwell TR Jackson MJ

Ischaemic preconditioning is a process by which exposure of a tissue to a short period of non-damaging ischaemic stress leads to resistance to the deleterious effects of a subsequent prolonged ischaemic stress. It has been extensively described in the heart, but few studies have examined the possibility that it can occur in skeletal muscle. We have used a rat model of ischaemia of one limb to examine this possibility. Exposure of the hind limb to a period of ischaemia of five minutes and reperfusion for five minutes significantly protected the tibialis anterior muscle against the structural damage induced by a subsequent period of limb ischaemia for four hours and reperfusion for one hour. This protection was evident on examination of the muscle by both light and electron microscopy. Longer or shorter times of prior ischaemia had no effect


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 45 - 45
1 Jul 2014
Vanhegan I Coathup M McCarthy I Haddad F Blunn G
Full Access

Summary Statement. Proximal femoral bony deficits present a surgical and biomechanical challenge to implant longevity in revision hip arthroplasty. This work finds comparable primary stability when a distally fixing tapered fluted stem was compared with a conical design in cadaveric tests. Introduction. Proximal bony deficits complicate revision hip surgery and compromise implant survival. Longer distally fixing stems which bypass such defects are therefore required to achieve stability compatible with bony ingrowth and implant longevity. Aims. It is hypothesised that a tapered stem will provide superior rotational stability to a conical design. This work therefore aims to compare the primary stability and biomechanical properties of a new design of tapered fluted modular femoral stem (Redapt®, Smith & Nephew) with that of a conical fluted stem (Restoration®, Stryker). Materials & Methods. 7 Pairs of cadaveric femora were obtained according to strict inclusion/exclusion criteria. Each underwent dual energy x-ray absorptiometry and calibration plain-film radiographs were taken. Digital templating was performed using TraumaCad (Voyant Health, Brainlab) to determine implant sizing. Both stems are fluted, modular and manufactured from titanium. The control stem (Restoration) featured a straight conical design and the investigation stem (Redapt) a straight tapered design. Implantation was performed by a revision arthroplasty surgeon familiar with both systems. Proximal bone deficiency was reproduced using an extended trochanteric osteotomy with removal of metaphyseal bone before reattaching the osteotomy. Primary stability in the axial, sagittal and coronal planes was assessed using micromotion transducers (HBM, Darmstadt, Germany) and also by Radiostereometric Analysis (RSA). RSA employs simultaneous biplanar radiographs to measure relative movement. Two 1mm tantalum beads were mounted on the prosthesis with the centre of the femoral head taken as the third reference point. Beads were placed proximally in the surrounding bone as rigid body markers. Each bone was potted according to the ISO standard for fatigue testing and cyclically loaded at 1Hz for at least 3 increments (750–350N, 1000–350N, 1500–350N) for 1000 cycles. RSA radiographs were taken at baseline and on completion of each cycle. A strain analysis was concurrently performed using a PhotoStress® (Vishay Precision Group, Raleigh, USA) photoelastic coating on the medial femoral cortex. Each bone was loaded intact and then with the prosthesis in-situ at 500N increments until strain fringes were identified. Once testing was completed, the stems were sectioned at the femoral isthmus and data is presented on the cross-sectional fit and fill observed. Results. Both stem designs showed comparable primary stability with all stems achieving clinically acceptable micromotion (<150 μm) when loaded at body weight. A larger proportion of the control stems remained stable as loading increased to x2-3 body weight. Transducer-recorded migration appeared greatest in the axial plane (y axis) with negligible distal movement in the coronal or sagittal planes. Point motion analysis (RSA) indicated most movement to be in the coronal plane (x-axis) whereas segment motion analysis showed rotation about the long axis of the prosthesis to be largest. Photoelastic strain patterns were transferred more distally in both designs, however substantial stress shielding was also observed. Discussion/Conclusion. Both designs achieved adequate distal fixation and primary stability under representative clinical loading conditions. This work supports the continued use of this novel stem design for revision surgery in the presence of extensive proximal bone loss


Bone & Joint 360
Vol. 6, Issue 5 | Pages 42 - 44
1 Oct 2017
Ross A


Bone & Joint Research
Vol. 5, Issue 7 | Pages 287 - 293
1 Jul 2016
Ismail H Phedy P Kholinne E Djaja YP Kusnadi Y Merlina M Yulisa ND

Objectives

To explore the therapeutic potential of combining bone marrow-derived mesenchymal stem cells (BM-MSCs) and hydroxyapatite (HA) granules to treat nonunion of the long bone.

Methods

Ten patients with an atrophic nonunion of a long bone fracture were selectively divided into two groups. Five subjects in the treatment group were treated with the combination of 15 million autologous BM-MSCs, 5g/cm3 (HA) granules and internal fixation. Control subjects were treated with iliac crest autograft, 5g/cm3 HA granules and internal fixation. The outcomes measured were post-operative pain (visual analogue scale), level of functionality (LEFS and DASH), and radiograph assessment.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1157 - 1163
1 Aug 2005
Peter B Zambelli P Guicheux J Pioletti DP

In an attempt to increase the life of cementless prostheses, an hydroxyapatite-coated implant which releases a bisphosphonate has been suggested as a drug-delivery system. Our in vitro study was designed to determine the maximum dose to which osteoblasts could be safely exposed.

Our findings demonstrated that zoledronate did not impair the proliferation of human osteoblasts when used at concentrations below 1 μm. Murine cells can be exposed to concentrations as high as 10 μm.

A concentration of 0.01% of titanium particles did not impair the proliferation of either cell line. Zoledronate affected the alkaline phosphatase activity of murine osteoblasts through a chelation phenomenon. The presence of titanium particles strongly decreased the alkaline phosphatase activity of murine osteoblasts. We did not detect any synergic effect of zoledronate and titanium particles on the behaviour of both human and murine osteoblasts.