Advertisement for orthosearch.org.uk
Results 1 - 20 of 60
Results per page:
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 111 - 111
1 Nov 2015
Rosenberg A
Full Access

When is revision surgery contraindicated in the face of a failed total hip? Surgically indicated can be interpreted as a situation where the patient will benefit from a specific intervention, with sufficient likelihood, to warrant the risks of intervention. Contraindication connotes the opposite; the risks, or likelihood of the intervention's failure to achieve the desired results outweigh the expected extent and likelihood of benefit. Contraindicated actually represents the end point of a complex decision making process which must be carried out by the practitioner in conjunction with the patient and may require the full range of the surgeons analytical, technical and communication skills. Most commonly the term means that the surgeon's thinking has led to a belief that the patient will be better off without further surgery.

Deciding to forego another revision usually means leaving the patient with a resection arthroplasty. Relative indications for resection, or even avoiding revision of a failed arthroplasty, are most commonly biological. In a healthy host, with a sterile but anatomically deficient bed with adequate soft tissue coverage, mechanical reconstruction capabilities and massive bulk allograft may allow reconstruction of almost any amount of tissue loss. Severe osteomyelitis or soft tissue infection, unmanageable for reasons, including but not limited to: chronic immune-suppression, mixed or resistant organisms or a life threatening sensitivity to antibiotics which may be required to treat the sepsis. More subjective factors, such as adequacy of soft tissue and bone stock, comorbid medical conditions or a patient's desire to avoid additional surgery as well as costs must be considered. This decision may include dozens of other considerations, some of which may be considered pre-operatively and some which may only arise intra-operatively.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 120 - 120
1 Feb 2015
Callaghan J
Full Access

Arthrodesis

Today, knee arthrodesis is most commonly performed for cases of chronic sepsis after total knee arthroplasty in patients who are not candidates for reimplantation. This is typically a host in whom the risk of recurrent infection is high, especially when extensor mechanism problems such as patellar tendon rupture is present. Local and systemic host factors place the patient at this high risk for failure of reimplantation. Local factors include chronic lymphedema, major vessel disease, venous stasis, extensive scarring and radiation fibrosis. Systemic problems include malnutrition, malignancy, extremes of age, hepatic or renal failure, diabetes mellitus and alcohol abuse. Also, at least in one study, patients who fail one two-stage reimplantation have at least a 50% change for recurrence the second time.

Methods of knee arthrodesis include external fixation, single or double plate fixation and intramedullary nailing either monolithic or modular. External fixation can be performed as a single procedure. With external ring fixators leg lengthening has been described. Plate and nailing procedures are commonly performed after the infection is eradicated. If infection recurs but fusion has occurred, removal of a modular nail may be difficult although techniques have been described. Fusion rates of 85% to 100% have been reported with the newer techniques and fusion rates are usually correlated with the amount of bone loss after removal of the prosthesis. Optimal position of fusion is slight anatomic valgus and slight flexion. Placing a bowed intramedullary nail with the bow anteromedially can facilitate this alignment. One study comparing arthrodesis after failed knee arthroplasty with primary total knee replacement found nearly identical Short-Form 36 scores. Physical mobility was better with knee arthroplasty but pain control was better with arthrodesis.

Resection Arthroplasty

Indication: Low demand patient with comorbidities

Results: Falahee et al.; 28 knees;15 patients walked independently; Most severely disabled more satisfied. Less disabled least satisfied.

Amputation - Above the Knee Amputations after TKA (Sierra et al)

Prevalence: 0.36% (all causes – most common was peripheral vascular disease), 0.14% (for causes related to TKA: infection, periprosthetic fracture, pain, bone loss, vascular complication)

Results: 25 amputations for causes related to TKA; Avg 8.6 years after TKA

Complications: deep infection 5, superficial infection 1, skin necrosis 1, perioperative death 1. 9 of 25 fitted with above knee prosthesis; Only 5 were walking even to limited degree with prosthesis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 10 - 10
1 Mar 2012
Dachepalli V Shah A Jeys L Purbach B
Full Access

Introduction

The aim of the study was to whether the bone grafting techniques used affected the long term stability of the acetabular implant.

Methods

41 patients treated with a cemented total hip replacement with pre-operative protrusio or central acetabular defects at surgery were identified. The severity of initial protrusio was determined on plain AP pelvis radiographs by measuring the distance of the medial acetabular wall from the ilio-ischial line. The post-operative and last follow-up x-rays were reviewed, the thickness of the medial wall and the centre-edge angle of the cup was measured.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 82 - 82
1 May 2012
McCombe P Williams S Spencer L
Full Access

The authors entered patients into a randomised trial to compare the results of the use of cemented and cementless acetabular prostheses between 1993 and 1995. The results of mid-term wear studies at average follow up of eight years were reported in the journal in 2004. We now present long-term results to show the eventual fate of the hip replacements under study.

The initial study group of 162 patients was randomly assigned to a modular titanium cup with a polyethylene liner or an all polyethylene cemented cup. All patients received a cemented stem with a 26 mm head and a standardised surgical technique. The polyethylene wear was estimated via head penetration measurement and the mid-term results showed a significantly higher wear rate in the cementless cups compared to the cemented cups (0.15mm/yr vs. 0.07mm/yr p<0.0001). The prediction was that this would lead to a higher rate of aseptic loosening in the cementless group.

Patients have now been re-examined at an average of 15 years with the main emphasis on prosthesis survival. Wear studies were also performed.

There were exclusions from the initial study because of death and reoperation for reasons other than aseptic loosening. The number of patients in this longer-term study had decreased as a result of death and loss to follow up. Revisions for aseptic loosening did not follow the path as suggested by the mid term wear studies. There were five cup revisions in the cemented group and one cup revision in the cementless group for aseptic loosening. No femoral stem was revised for aseptic loosening. Details of the long-term wear studies will be presented and osteolysis rates and extent documented.

Despite the statistically significant difference in wear rates at the mid term, an incorrect prediction of eventual loosening rates was made. The authors believe that there are many factors other than wear rates involved in longevity of fixation. We also believe there are many weaknesses in long term prospective, randomised trials in joint replacement and question whether they are, in fact, level 1 evidence in the age of evidence based medicine.


Full Access

Objective

To evaluate the effect of claiming compensation on health status for people with mild to moderate injuries sustained in road traffic collisions (RTC).

Methods

The design was a prospective cohort study in the Australian Capital Territory (ACT), Australia and a fault based compensation system. The subjects were people with mild to moderate musculoskeletal injuries who presented to the emergency department within 7 days of an RTC. Outcome Measures were Physical Component Score (PCS) and Mental Component Score (MCS) of the Short Form 36 (SF-36) health status measure; Hospital Anxiety and Depression Scale (HADS); and the Functional Rating Index (FRI). These measures were recorded immediately RTC, and at 6 and 12 months.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 106 - 106
10 Feb 2023
Lin D Xu J Weinrauch P Yates P Young D Walter W
Full Access

Hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty. We present the early 1 and 2-year clinical and radiographical follow-up of a novel ceramic-on-ceramic (CoC) HRA in a multi-centric Australian cohort. Patient undergoing HRA between September 2018 and April 2021 were prospectively included. Patient-reported outcome measures (PROMS) in the form of the Forgotten Joint Score (FJS), HOOS Jr, WOMAC, Oxford Hip Score (OHS) and UCLA Activity Score were collected preoperatively and at 1- and 2-years post-operation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis/loosening and heterotopic ossification formation. 209 patients were identified of which 106 reached 2-year follow-up. Of these, 187 completed PROMS at 1 year and 90 at 2 years. There was significant improvement in HOOS (p< 0.001) and OHS (p< 0.001) between the pre-operative, 1-year and 2-years outcomes. Patients also reported improved pain (p<0.001), function (p<0.001) and reduced stiffness (p<0.001) as measured by the WOMAC score. Patients had improved activity scores on the UCLA Active Score (p<0.001) with 53% reporting return to impact activity at 2 years. FJS at 1 and 2-years were not significantly different (p=0.38). There was no migration, osteolysis or loosening of any of the implants. The mean acetabular cup inclination angle was 41.3° and the femoral component shaft angle was 137°. No fractures were reported over the 2-year follow-up with only 1 patient reporting a sciatic nerve palsy. There was early return to impact activities in more than half our patients at 2 years with no early clinical or radiological complications related to the implant. Longer term follow-up with increased patient numbers are required to restore surgeon confidence in HRA and expand the use of this novel product. In conclusion, CoC resurfacing at 2-years post-operation demonstrate promising results with satisfactory outcomes in all recorded PROMS


Bone & Joint Open
Vol. 2, Issue 8 | Pages 655 - 660
2 Aug 2021
Green G Abbott S Vyrides Y Afzal I Kader D Radha S

Aims. Elective orthopaedic services have had to adapt to significant system-wide pressures since the emergence of COVID-19 in December 2019. Length of stay is often recognized as a key marker of quality of care in patients undergoing arthroplasty. Expeditious discharge is key in establishing early rehabilitation and in reducing infection risk, both procedure-related and from COVID-19. The primary aim was to determine the effects of the COVID-19 pandemic length of stay following hip and knee arthroplasty at a high-volume, elective orthopaedic centre. Methods. A retrospective cohort study was performed. Patients undergoing primary or revision hip or knee arthroplasty over a six-month period, from 1 July to 31 December 2020, were compared to the same period in 2019 before the COVID-19 pandemic. Demographic data, American Society of Anesthesiologists (ASA) grade, wait to surgery, COVID-19 status, and length of hospital stay were recorded. Results. A total of 1,311 patients underwent hip or knee arthroplasty in the six-month period following recommencement of elective services in 2020 compared to 1,527 patients the year before. Waiting time to surgery increased in post-COVID-19 group (137 days vs 78; p < 0.001). Length of stay also significantly increased (0.49 days; p < 0.001) despite no difference in age or ASA grade. There were no cases of postoperative COVID-19 infection. Conclusion. Time to surgery and length of hospital stay were significantly higher following recommencement of elective orthopaedic services in the latter part of 2020 in comparison to a similar patient cohort from the year before. Longer waiting times may have contributed to the clinical and radiological deterioration of arthritis and general musculoskeletal conditioning, which may in turn have affected immediate postoperative rehabilitation and mobilization, as well as increasing hospital stay. Cite this article: Bone Jt Open 2021;2(8):655–660


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 85 - 85
1 Dec 2022
Yin D Couture J
Full Access

Direct oral anticoagulant (DOAC) use is becoming more widespread in the geriatric population. Depending on the type of DOAC, several days are required for its anticoagulant effects to resorb, which may lead to surgical delays. This can have an important impact on hip fracture patients who require surgery. The goal of the current study is to compare surgical delays, mortality and complications for hip fracture patients who were on a DOAC to those who were not. A retrospective cohort study was conducted at a university hospital in Sherbrooke. All hip fracture patients between 2012 and 2018 who were on a DOAC prior to their surgery were included. These patients were matched with similar patients who were not on an anticoagulant (non-DOAC) for age, sex, type of fracture and date of operation. Demographic and clinical data were collected for all patients. Surgical delay was defined as time of admission to time of surgery. Mortality and complications up to one year postoperative were also noted. Each cohort comprised of 74 patients. There were no statistically signification differences in Charleson Comorbidty Index and American Society of Anesthesiologists scores between cohorts. Surgical delay was significantly longer for DOAC patients (36.3±22.2 hours vs. 18.6±18.9 hours, p < 0 .001). Mortality (6.1%) and overall complication (33.8%) rates were similar between the two cohorts. However, there were more surgical reinterventions in DOAC patients than non-DOAC ones (16.2% vs. 0.0%, p < 0 .001). Among DOAC patients, mortality was greater for those operated after 48 hours (23.1% vs. 3.3%, p < 0 .05) and complications were more frequent for those operated after 24 hours (52.0% vs. 37.5%, p < 0 .05). Direct oral anticoagulant (DOAC) use in hip fracture patients is associated with longer surgical delays. Longer delays to surgery are associated with higher mortality and complication rates in hip fracture patients taking a DOAC. Hip fracture patients should have their surgery performed as soon as medically possible, regardless of anticoagulant use


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 60 - 60
1 Dec 2022
Yin D Couture J
Full Access

Direct oral anticoagulant (DOAC) use is becoming more widespread in the geriatric population. Depending on the type of DOAC, several days are required for its anticoagulant effects to resorb, which may lead to surgical delays. This can have an important impact on hip fracture patients who require surgery. The goal of the current study is to compare surgical delays, mortality and complications for hip fracture patients who were on a DOAC to those who were not. A retrospective cohort study was conducted at a university hospital in Sherbrooke. All hip fracture patients between 2012 and 2018 who were on a DOAC prior to their surgery were included. These patients were matched with similar patients who were not on an anticoagulant (non-DOAC) for age, sex, type of fracture and date of operation. Demographic and clinical data were collected for all patients. Surgical delay was defined as time of admission to time of surgery. Mortality and complications up to one year postoperative were also noted. Each cohort comprised of 74 patients. There were no statistically signification differences in Charleson Comorbidty Index and American Society of Anesthesiologists scores between cohorts. Surgical delay was significantly longer for DOAC patients (36.3±22.2 hours vs. 18.6±18.9 hours, p < 0 .001). Mortality (6.1%) and overall complication (33.8%) rates were similar between the two cohorts. However, there were more surgical reinterventions in DOAC patients than non-DOAC ones (16.2% vs. 0.0%, p < 0 .001). Among DOAC patients, mortality was greater for those operated after 48 hours (23.1% vs. 3.3%, p < 0 .05) and complications were more frequent for those operated after 24 hours (52.0% vs. 37.5%, p < 0 .05). Direct oral anticoagulant (DOAC) use in hip fracture patients is associated with longer surgical delays. Longer delays to surgery are associated with higher mortality and complication rates in hip fracture patients taking a DOAC. Hip fracture patients should have their surgery performed as soon as medically possible, regardless of anticoagulant use


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 38 - 38
1 Jul 2020
Gkagkalis G Kutzner KP Goetti P Mai S Meinecke I Helmy N Solothurn B Bosson D
Full Access

Short-stem total hip arthroplasty (THA) has primarily been recommended for young and active patients, mainly due to its bone preserving philosophy. Elderly patients, however, may also benefit of a minimally invasive technique due to the short and curved implant design. The purpose of this study was to compare the clinical and radiological outcomes as well as perioperative complications of a calcar-guided short stem between a young (75 years) population. Data were collected in a total of 5 centers, and 400 short stems were included as part of a prospective multicentre observational study between 2010 and 2014 with a mean follow-up of 49.2 months. Clinical and radiological outcomes were assessed in both groups. Secondary outcomes such as perioperative complications, rates and reasons for stem revision were also investigated. No differences were found for the mean visual analogue scale (VAS) values of rest pain, load pain, and satisfaction. Harris Hip Score (HHS) was found to be slightly better in the young group. Comparing both groups, no statistically significant differences ere found in the radiological parameters that were assessed (stress-shielding, cortical hypertrophy, radiolucency, osteolysis). Aseptic loosening was the main cause of implant failure in younger patients whereas in elderly patients, postoperative periprosthetic fractures due to accidental fall was found to be the main cause for stem revision. These short-term results are encouraging towards the use of a cementless short stem in the geriatric population. According to our findings, advanced age and potentially reduced bone quality should not necessarily be considered as contra-indications for calcar-guided short-stem THA but careful and reasonable selection of the patients is mandatory. Longer follow up is necessary in order to draw safer conclusions


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 3 - 3
1 Aug 2020
Seddigh S Dunbar MJ Douglas J Lethbridge L Theriault P
Full Access

Currently 180 days is the target maximum wait time set by all Canadian provinces for elective joint replacement surgery. In Nova Scotia however, only 34% of Total Knee Arthroplasties (TKA) and 51% of Total Hip Arthroplasties (THA) met this benchmark in 2017. Surgery performed later in the natural history of disease is shown to have significant impact on pain, function and Health related Quality of Life at the time of surgery and potentially affect post-operative outcomes. The aim of this study is to describe the association between wait time and acute hospital Length of Stay (LOS) during elective hip and knee arthroplasty in province of Nova Scotia. Secondarily we aim to describe risk factors associated with variations in LOS. Data from Patient Access Registry Nova Scotia (PAR-NS) was linked to the hospital Discharge Access Database (DAD) for primary hip and knee arthroplasty spanning 2009 to 2017. There were 23,727 DAD observations and 21,329 PARNS observations identified. Observations were excluded based on missing variables, missing linkages, revision status and emergency cases. Percentage difference in LOS, risk factors and outcomes were analyzed using Poisson regression for those waiting more than 180 days compared to those waiting equal or less than 180 days. For primary TKA, 11,833 observations were identified with mean age of 66 years, mean wait time of 348 days and mean LOS of 3.6 days. After adjusting for controls, patients waiting more than 180 days for elective TKA have a 2.5% longer acute care LOS (p < 0.028). Risk factors identified for prolonged LOS are advanced age, female gender, higher surgical priority indicator, required blood transfusion, dementia, peptic ulcer disease, cerebrovascular disease, heart failure, chronic kidney disease, malignancy, ischemic heart disease and diabetes. Factors associated with decreased LOS are surgical year, use of local anesthetic, peripheral location of hospital and admission to hospital from home. For primary THA, 6626 observations were identified with mean age of 66 years, mean wait time of 267 days and mean LOS of 4 days. Patients waiting more than 180 days for THA did not show a statistically significant association with LOS. Risk factors and protective factors are the same with exception of CVD and use of local anesthetic. Our findings suggest a positive and statistically significant association for patients waiting more than 180 days for TKA and longer acute care LOS. Longer LOS may be due to deteriorating health status while placed on a surgical waitlist and may represent a delayed and indirect cost to the patient and the healthcare system. Ultimately with projected increase in demand for elective joint replacement surgeries, our findings are aimed to inform physicians and policy makers in management of surgical waitlist efficiency and cost effectiveness. For any reader inquiries, please contact . shahriar-s@hotmail.com


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 37 - 37
1 Jul 2020
Lalone E Grewal R Seltser A Albakri K MacDermid J Suh N Perrin M
Full Access

Scaphoid fractures are a common injury accounting for more than 58% of all carpal bone fractures(1,2). Biomechanical studies have suggested that scaphoid mal-union may lead to altered carpal contact mechanics causing decreased motion, pain and arthritis(1,2). The severity of mal-union required to cause deleterious effects has yet to be established. This limits the ability to define surgical indications or impacts on prevention of posttraumatic arthritis. Computed tomography has been shown to be a useful in determining the 3D implications of altered bony alignment on the joint contact mechanics of surrounding joints. The objective of this study was to report mid-term follow-up image-based outcomes of patients with scaphoid mal-unions to determine the extent to which arthritic changes and decreased joint space is present after a minimum of 4 years following fracture. Participants (n=14) who had previously presented with a mal-united scaphoid fracture (indicated by a Height:Length Ratio >0.6) between November 2005 and November 2013 were identified and contacted. A short-arm thumb spica case was used to treat X patients and X required surgical management. Baseline and follow-up CT images, were performed with the wrist in radial deviation and positioned such that the long axis of the scaphoid was perpendicular to the axis of the scanner. Three-dimensional inter-bone distance (joint space), a measure of joint congruency and 3D alignment, was quantified from reconstructed CT bone models of the distal radius, scaphoid, lunate, capitate, trapezium and trapezoid from both the baseline and follow-up scans(3). Repeated measures ANOVA was used to detect differences in contact area (mm2) between baseline and follow-up CT's for the radioscaphoid, scaphocapitate and scaphotrapezium-trapezoid joint. The average age of participants was 43.1 years (16–64 years old). There was significant loss of joint space, indicated by a greater joint contact area 3–4 years post fracture, between baseline and follow-up reconstruction models, at the scaphocapitate (mean difference: 21.5±146mm2, p=0.007) and scaphotrapezoid joints (mean difference: 18.4 ±28.6mm2, 0.042). Significant differences in the measured contact area was not found for the radioscaphoid (0.153) and scaphotrapezium joints (0.72). Additionally, the scaphoid, qualitatively, appears to track in the vorsal direction in the majority of patients following fracture. Increased joint contact area in the scaphocapitate and scaphotrapezoid joint 3–4 years following fracture results from decreased 3D joint space and overall narrowing. Joint space narrowing, while not significantly different for all joints examined, was reduced for all joints surrounding the scaphoid. Decreased joint space and increased contact area detectable within this short interval might be suggestive of a trajectory for developing arthritis in the longer term, and illustrates the potential value of these measures for early detection. Longer term follow-up and correlation to clinical outcomes are needed to determine the importance of early joint space narrowing, and to identify those most at risk


Introduction. Robotic-assisted hip arthroplasty helps acetabular preparation and implantation with the assistance of a robotic arm. A computed tomography (CT)-based navigation system is also helpful for acetabular preparation and implantation, however, there is no report to compare these methods. The purpose of this study is to compare the acetabular cup position between the assistance of the robotic arm and the CT-based navigation system in total hip arthroplasty for patients with osteoarthritis secondary to developmental dysplasia of the hip. Methods. We studied 31 hips of 28 patients who underwent the robotic-assisted hip arthroplasty (MAKO group) between August 2018 and March 2019 and 119 hips of 112 patients who received THA under CT-based navigation (CT-navi group) between September 2015 and November 2018. The preoperative diagnosis of all patients was osteoarthritis secondary to developmental dysplasia of the hip. They received the same cementless cup (Trident, Stryker). Robotic-assisted hip arthroplasty were performed by four surgeons while THA under CT-based navigation were performed by single senior surgeon. Target angle was 40 degree of radiological cup inclination (RI) and 15 degree of radiological cup anteversion (RA) in all patients. Propensity score matching was used to match the patients by gender, age, weight, height, BMI, and surgical approach in the two groups and 30 patients in each group were included in this study. Postoperative cup position was assessed using postoperative anterior-posterior pelvic radiograph by the Lewinnek's methods. The differences between target and postoperative cup position were investigated. Results. The acetabular cup position of all cases in both Mako and CT-navi group within Lewinnek's safe zone (RI: 40±10 degree; RA: 15±10 degree) in group were within this zone. Three was no significant difference of RI between Mako and CT-navi group (40.0 ± 2.1 degree vs 39.7± 3.6 degree). RA was 15.0 ± 1.2 degree and 17.0 ± 1.9 degree in MAKO group and in CT-navi group, respectively, with significant difference (p<0.001). The differences of RA between target and postoperative angle were smaller in MAKO group than CT-navi group (0.60± 1.05 degree vs 2.34± 1.40 degree, p<0.001). The difference or RI in MAKO group was smaller than in CT-navi, however, there was no significance between them (1.67± 1.27 degree vs 2.39± 2.68 degree, p=0.197). Conclusions. Both the assistance of the robotic arm and the CT-based navigation system were helpful to achieve the acetabular cup implantation, however, MAKO system achieved more accurate acetabular cup implantation than CT-based navigation system in total hip arthroplasty for the patients with OA secondary to DDH. Longer follow-up is necessary to investigate the clinical outcome


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 49 - 49
1 Apr 2019
Harman C Afzal I Shardlow D Mullins M Hull J Kashif F Field R
Full Access

INTRODUCTION. Historically, the clinical performance of novel implants was usually reported by designer surgeons who were the first to acquire clinical data. Regional and national registries now provide rapid access to survival data on new implants and drive ODEP ratings. To assess implant performance, clinical and radiological data is required in addition to implant survival. Prospective, multi-surgeon, multi-centre assessments have been advocated as the most meaningful. We report the preliminary results of such a study for the MiniHip™femoral component and Trinity™ acetabular component (Corin Ltd, UK). METHODS. As part of a non-designer, multi-surgeon, multi-centre prospective surveillance study to assess the MiniHip™stem and Trinity™ cup, 535 operations on 490 patients were undertaken. At surgery, the average age and BMI of the study group was 58.2 years (range 21 to 76 years) and 27.9 (range 16.3 to 43.4) respectively. Clinical (Harris Hip Score, HHS) and radiological review have been obtained at 6 months, 3 and 5 years. Postal Oxford Hip Score (OHS) and EuroQol- 5D (EQ5D) score have been obtained at 6 months and annually thereafter. To date, 23 study subjects have withdrawn or lost contact, 11 have died, and 9 have undergone revision surgery. By the end of March 2018, 6 month, 1, 2, 3, 4, and 5 year data had been obtained for 511, 445, 427, 376, 296 and 198 subjects respectively. RESULTS. Implant revision rate is 1.68% (9/535), with revision for any reason as an endpoint; four of the nine involved the revision of the femoral component. At the 5-year time point, mean OHS had improved from 21.3 to 42.5 (p<0.01), EQ5D from 0.42 to 0.82 (p<0.01), and HHS from 51.6 to 92.5 (p<0.01). Radiological analysis is ongoing, and thus far has revealed more variation in stem alignment than is usually observed for more conventional length femoral components. This may indicate that optimal alignment of calcar loading short stems is different to that of longer, medullary canal aligned implants, consistent with the neck-stabilised design of the MiniHip™ stem. No other significant radiological findings were noted. During surgery, 31 calcar fractures were sustained, of which 20 were treated with cerclage wiring, 1 with femoral grafting and the remainder required no treatment. None of the hips with calcar fractures have been revised to date. DISCUSSION. The clinical and radiological performance of the MiniHip™ femoral stem is consistent with established femoral implants. Longer surveillance will determine whether this performance is maintained. Patients in this study will be continued to be followed-up and reviewed at the 7 and 10-year time points. CONCLUSION. The MiniHip™ stem is safe and efficacious at mid-term follow-up


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 63 - 63
1 Apr 2019
Greene A Cheung E Polakovic S Hamilton M Jones R Youderian A Wright T Saadi P Zuckerman J Flurin PH Parsons I
Full Access

INTRODUCTION. Preoperative planning software for anatomic total shoulder arthroplasty (ATSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in ATSA. METHODS. CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided three implant types: a standard non-augmented glenoid component, and an 8° and 16° posterior augment wedge glenoid component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior- posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case. RESULTS. Five cases were excluded due to extreme glenoid wear. For resultant implant version, a bimodal distribution was observed with a local maxima occurring at 0 degrees, and a bell-shaped distribution at −5° of version. Upon individual surgeon analysis, it was revealed that certain surgeons had a preference to correct to 0 degrees, whereas others were more accepting of residual version. Shoulders ranged in native version from 0° to −27° with an average of −11°, indicating a high frequency of posterior glenoid wear. The frequency of different implants used for each degree of version shows that standard implants were never used when version was > −11°. Conversely, 16° augmented glenoids were never used when the version was < −9°. Based on this distribution, version was divided into 3 ranges: < −6°, −7 to −14°, and > −15°. Standard glenoids were used 79% of the time when the version was <−6°. 8° augmented glenoids were used 80% of the time when the version was between −7° and −14°, and 75% of the time when the version was > −15°. In the latter case, 16° augments were used in the other 25%. For inclination in ATSA, the same trends of a bimodal distribution seen for version were less pronounced. A local maxima of plans were focused around zero degrees, with some surgeons being more accepting of superior inclination in ATSA. CONCLUSION. While there was limited consensus on the optimal reconstruction in any one case, there appear to be thresholds of retroversion that favor the use of augmented glenoid components based on frequency of selection. Our data suggests when retroversion exceeds −7°, some degree of augmentation is helpful in achieving the goals of version correction while limiting bone loss through corrective reaming. Longer term clinical outcomes on specific implant positions will help to define true optimal implant placement


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 67 - 67
1 Jun 2018
Gonzalez Della Valle A
Full Access

Uncontained acetabular defects with loss of superior iliac and posterior column support (Paprosky 3) represent a reconstructive challenge as the deficient bone will preclude the use of a conventional hemispherical cup. Such defects can be addressed with large metallic constructs like cages with and without allograft, custom tri-flange cups, and more recently with trabecular metal augments. An underutilised alternative is impaction bone grafting, after creating a contained cavitary defect with a reinforcement mesh. This reconstructive option delivers a large volume of bone while using a small-size socket fixed with acrylic cement. Between 2005 and 2014, 21 patients with a Paprosky 3B acetabular defect were treated with cancellous, fresh frozen impaction grafting supported by a peripheral reinforcement mesh secured to the pelvis with screws. A cemented all-polyethylene cup was used. Pre-operative diagnosis was aseptic loosening (15 cemented and 6 uncemented). The femoral component was revised in 10 patients. Post-operative course consisted of 3 months of protected weight bearing. Patients were followed clinically and radiographically. One patient had an incomplete post-operative sciatic palsy. After a mean follow up of 47 months (13 to 128) none of the patients required re-revision of the acetabular component. One asymptomatic patient presented with aseptic loosening 9 years post-operatively. Hardware failure was not observed. All patients had radiographic signs of graft incorporation and bone remodeling. There were no dislocations. The early and mid-term results of revisions of large acetabular defects with this technique are encouraging. Reconstitution of hip center of rotation and bone stock with the use of a small-size implant makes this technique an attractive option for large defects. Longer follow-up is needed to assess survivability


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 3 - 3
1 Dec 2017
Jenny J
Full Access

INTRODUCTION. Unicompartmental knee arthroplasty (UKA) is considered a highly successful procedure. However, complications and revisions may still occur, and some may be related to the operative technique. Computer assistance has been suggested to improve the accuracy of implantation of a UKA. The present study was designed to evaluate the long-term (more than 10 years) results of an UKA which was routinely implanted with help of a non-image based navigation system. MATERIAL AND METHODS. All patients operated on between 2004 and 2005 for implantation of a navigated UKA were included. Usual demographic and peri-operative items have been record. All patients were prospectively followed with clinical and radiological examination. All patients were contacted after the 10 year follow-up for repeat clinical and radiological examination (KSS, Oxford knee questionnaire and knee plain X-rays). Patients who did not return were interviewed by phone call. For patients lost of follow-up, family or general practitioner was contacted to obtain relevant information about prosthesis survival. Survival curve was plotted according to Kaplan-Meier. RESULTS. 57 UKAs were implanted during the study time-frame. Final follow-up (including death or revision) was obtained for 50 cases (88%). Clinical status after 10 years was obtained for 45 cases (80%). 4 prosthetic revisions were performed for mechanical reasons during the follow- up time (7%). The 10 year survival rate was 94%. No component was considered loose at the final radiographic evaluation. No polyethylene wear was detected at the final radiographic evaluation. DISCUSSION. This study confirms our initial hypothesis, namely quite satisfactory results of a navigated implanted UKA after more than 10 years. Navigation, whose precision is no longer to be demonstrated, probably contributed to the quality of the results. A more consistent anatomical reconstruction and ligamentous balance of the knee should lead to more consistent survival of the UKA. However, superiority of navigated UKA in comparison to conventional implanted UKA is difficult to prove because of the subtle differences expected in mostly underpowered studies. Longer term follow-up may be required


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 14 - 14
1 Oct 2017
Obi NJ Egan C Bing AJ Makwana NK
Full Access

Optimal treatment for symptomatic talus Osteochondral Lesions (OCLs) where primary surgical techniques have failed has not been established. Recent advances have focussed on biological repair such as Autologous Chondrocyte Implantation (ACI) however funding for this treatment is limited. Stem cell therapy in the ankle has not been assessed. The purpose of this pilot study was to evaluate the safety and efficacy of stem cell therapy in the treatment of ankle OCLs. The study was approved by the new procedures committee. Between January 2015 and December 2016, 26 patients, mean age of 36 years (range 16–58 years) with persisting disabling symptoms underwent Complete Cartilage Regeneration (CCR) using stem cells for failed primary treatment for ankle OCLs. Treatment involved iliac crest bone marrow aspiration, centrifugation to obtain bone marrow concentrate (BMC), and then injection of the BMC combined with hyaluronic acid into the OCL. Any necessary additional procedures, e.g. bone grafting or lateral ligament reconstruction were also undertaken. In 18 patients the lesion was on the medial talar dome, in 5 the lateral talar dome, 2 multiple, 1 tibial plafond. The Manchester-Oxford Foot Questionnaire (MOXFQ) was utilised to assess outcome. Average pre-operative MOXFQ scores were Walking dimension −78, Pain dimension − 65, and Social dimension − 64.2. Average 3 month post-operative MOXFQ scores were Walking − 54.8, Pain − 35.4, Social − 38.9. Average 6 month post-operative MOXFQ scores were Walking − 34.4, Pain − 35.4, Social − 28. Two patients from the beginning of the series had AOFAS scores only which improved from an average of 55 pre-operatively to 76 post-operatively. No early complications were noted. We conclude that CCR treatment is a safe treatment for talus OCLs in patients who have failed primary treatment. The procedure avoids two-stage surgery of ACI in some patients without large cysts. The early clinical outcome is favourable with no complications noted. Longer term follow-up is required


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 67 - 67
1 Aug 2017
Berry D
Full Access

Introduction. The use of stems in TKA revision surgery is well established. Stems off-load stress over a broad surface area of the diaphysis and help protect the metaphyseal interface areas from failure. Stems can provide an area of extra fixation. Uncemented Stems. Pros and Cons. Advantages. (1) Expeditious, (2) Compatible with intramedullary based revision instrumentation (3) Easy to remove if necessary (4) By filling diaphysis they help guarantee axial alignment. Disadvantages. (1) They help off load stress, but how much fixation do they really provide? (2) They don't fit all canal deformities, and under some circumstances can actually force implants into malalignment. (3) ? potential for end of stem pain. Cemented Stems. Pros and Cons. Advantages. (1) Cemented stem adds fixation in fresh metaphyseal and diaphyseal bone. (2) Proven 10-year track record. (3) Allow the surgeon to adjust for canal geometry abnormalities. Disadvantages. (1) More difficult to remove, if required. (2) They don't fill the canal so they don't guarantee alignment as well under most circumstances. Results. Favorable results with uncemented and cemented stems have been reported in several series. Cemented stems have longer term data. Technique Issues. Uncemented Stems. (1) Take advantage of offset bolts, tibial trays, stems to fit the stem/implant to the patient's anatomy. (2) Don't let the stem force you into suboptimal implant position. (3) Longer stems can be narrower but help engage more diaphysis. (4) Do a good job of restoring/uncovering cancellous bone in metaphysis for cement interdigitation. The cement provides the fixation. Cemented Stems. (1) Intra-operative x-ray with trials helps guarantee optimal alignment. (2) Use cement restrictors. (3) Cement tibia/femur separately. Metaphyseal Fixation. (1) Area of new emphasis. (2) Cones and sleeves can improve cemented and uncemented fixation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 38 - 38
1 Apr 2018
Jenny J
Full Access

INTRODUCTION. Total knee arthroplasty (TKA) is considered a highly successful procedure. Survival rates of more than 90% after 10 years are generally reported. However, complications and revisions may still occur for many reasons, and some of them may be related to the operative technique. Computer assistance has been suggested to improve the accuracy of implantation of a TKA (Jenny 2005). Short term results are still controversial (Roberts 2015). However, few long term results have been documented (Song 2016). The present study was designed to evaluate the long-term (more than 10 years) results of a TKA which was routinely implanted with help of a non-image based navigation system. The 5- to 8-year of this specific TKA has already been documented (Jenny 2013). The hypothesis of this study will be that the 10 year survival rate of this TKA will be improved in comparison to historical papers when analyzing survival rates and knee function as evaluated by the Knee Society Score (KSS). MATERIAL AND METHODS. All patients operated on between 2001 and 2004 for implantation of a navigated TKA were eligible for this study. Usual demographic and peri-operative items have been record. All patients were prospectively followed with clinical and radiological examination. All patients were contacted after the 10 year follow-up for repeat clinical and radiological examination (KSS, Oxford knee questionnaire and knee plain X-rays). Patients who did not return were interviewed by phone call. For patients lost of follow-up, family or general practitioner was contacted to obtain relevant information about prosthesis survival. Survival curve was plotted according to Kaplan-Meier. RESULTS. 247 TKAs were implanted during the study time-frame. 225 cases had an optimal lower limb axis (HKA angle between 177° and 183°) after TKA (91%). Final follow-up (including death or revision) was obtained for 200 cases (81%). Clinical status after 10 years was obtained for 146 cases (59%) (KSS, 102 cases – Oxford questionnaire, 146 cases – radiologic evaluation, 94 cases). 4 prosthetic revisions were performed for mechanical reasons during the follow-up time (1%). The 10 year survival rate was 98%. The mean KSS was 188 points. The mean Oxford score was 55 points. No component was considered loose at the final radiographic evaluation. No polyethylene wear was detected at the final radiographic evaluation. DISCUSSION. This study confirms our initial hypothesis, namely quite satisfactory results of navigated implanted TKA after more than 10 years. Navigation, whose precision is no longer to be demonstrated, probably contributed to the quality of the results. A more consistent anatomical reconstruction and ligamentous balance of the knee should lead to more consistent survival of the TKA. Other authors did observe similar results (Baumbach 2016). However, superiority of navigated TKA in comparison to conventional implanted TKA is difficult to prove because of the subtle differences expected in mostly underpowered studies. Longer term follow-up may be required