Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 29 - 29
1 Jul 2022
Bishi H Afzal I Wang C Stammers J Mitchell P Field R Alazzawi S
Full Access

Abstract. Introduction. In revision knee arthroplasty, rotating hinge implants (RHK) have been considered to result in higher complication rates and lower survivorship when compared to constrained condylar implants (CCK). The aims of this study were to compare patient reported outcome measures (PROMs), complication rates and survivorship of RHK and CCK used in revision arthroplasty at a single, high volume elective orthopaedic centre with previously validated bespoke database. Methodology. One hundred and eight patients who underwent revision knee arthroplasty with either CCK or RHK and matched our inclusion criteria were identified. EQ5D, Health State and Oxford Knee Scores were collected pre-operatively and at 1 year post-operatively. Complication data was collected at 6 weeks, 6 months, 1 year and 2 years post-operatively. NJR data was interrogated, in addition to our own database, to investigate implant survival. Results. There was no statistically significant difference between RHK and CCK in implant survival at two to twelve years of follow up. In addition, we observed no statistically significant difference in the PROMs scores and complication rates of the two implants. Conclusion. This study shows that both the RHK and CCK remain viable options in revision arthroplasty, the implant survival and complication rate were comparable. We recommend prospective randomised control trials with long-term follow up to further investigate the use of CCK and RHK implants in revision knee arthroplasty


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 467 - 472
1 Apr 2014
Nakamura E Okamoto N Nishioka H Karasugi T Hirose J Mizuta H

We report the long-term outcome of 33 patients (37 knees) who underwent proximal tibial open-wedge osteotomy with hemicallotasis (HCO) for medial osteoarthritis of the knee between 1995 and 2000. Among these, 29 patients with unilateral HCO were enrolled and 19 were available for review at a mean of 14.2 years (10 to 15.7) post-operatively. For these 19 patients, the mean Hospital for Special Surgery knee score was 60 (57 to 62) pre-operatively and 85 (82 to 87) at final follow-up (p < 0.001; paired t-test). The femorotibial angle and tibial inclination angle (IA) were measured at short-term follow-up, one to four years post-operatively, and showed no significant subsequent changes. The clinical scores and radiological measurements showed little change over time. One patient required conversion to total knee replacement during this time. These results suggest that the coronal angle achieved at operation is maintained at long-term follow up after HCO without alteration of the IA, providing a good long-term clinical outcome. Cite this article: Bone Joint J 2014;96-B:467–72


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 89 - 89
1 Mar 2012
Sarasin S Lewis J Padgett J Davies A
Full Access

Patellofemoral unicompartmental joint replacement is a controversial subject with a relatively small evidence base. Of the 50,000 total knee arthroplasties performed each year in the UK, approximately 10% are performed for predominantly patellofemoral arthritis. There are several patellofemoral unicompartmental prostheses on the market with the National Joint Registry recording 745 such prostheses used in 2007. Most evidence in favour of this procedure comes from experience with the Avon prosthesis (Stryker) predominantly from designer-surgeons. The FPV patellofemoral joint replacement (Wright Medical) has been in use in Europe for several years. The instruments have recently been redesigned and the device marketed in the UK. In 2007 the FPV had 5.9% market share (n=44). We present our early experience with the FPV patellofemoral joint replacement, which to our knowledge, is the first clinical outcome series for this prosthesis. 33 consecutive FPV joint replacements in 29 patients were performed between April 2007 and September 2009 for unicompartmental patellofemoral OA. All cases were performed or directly supervised by the senior author. Results are presented with a minimum follow-up of six months. Oxford and American Knee Society scores (AKSS) were obtained on all patients preoperatively and at subsequent outpatient visits. Mean preoperative AKSS knee score was 49.7 points and postoperative scores at 6 months and 1 year were 82.5 and 86.4 respectively. Mean Oxford score preoperatively was 30.4 (37%) and at 6 months and 1 year were 21.3 (56%) and 11.2 (77%) respectively. There were no complications related to the implant. One knee required a secondary open lateral release due to inadequate balancing at the index procedure. Further medium to long-term follow up data are required, but our initial experience with this device is encouraging


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1579 - 1584
1 Dec 2018
Turgeon TR Gascoyne TC Laende EK Dunbar MJ Bohm ER Richardson CG

Aims

The introduction of a novel design of total knee arthroplasty (TKA) must achieve outcomes at least as good as existing designs. A novel design of TKA with a reducing radius of the femoral component and a modified cam-post articulation has been released and requires assessment of the fixation to bone. Radiostereometric analysis (RSA) of the components within the first two postoperative years has been shown to be predictive of medium- to long-term fixation. The aim of this study was to assess the stability of the tibial component of this system during this period of time using RSA.

Patients and Methods

A cohort of 30 patients underwent primary, cemented TKA using the novel posterior stabilized fixed-bearing (ATTUNE) design. There was an even distribution of men and women (15:15). The mean age of the patients was 64 years (sd 8) at the time of surgery; their mean body mass index (BMI) was 35.4 kg/m2 (sd 7.9). RSA was used to assess the stability of the tibial component at 6, 12, and 24 months compared with a six-week baseline examination. Patient-reported outcome measures were also assessed.