Advertisement for orthosearch.org.uk
Results 1 - 20 of 935
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 86 - 86
23 Feb 2023
Rele S Shadbolt C Elsiwy Y Naufal E Gould D Bazargan A Lorenzo Y Choong P Dowsey M Stevens J
Full Access

Use of anticoagulants for thromboembolic prophylaxis is strongly supported by evidence. However, the use of these medications beyond the prophylactic period is poorly understood. We identified anticoagulant naïve patients that underwent hip or knee replacement between 2012 and 2019 from an arthroplasty registry and probabilistically linked 3,018 surgeries with nationwide pharmaceutical claims data. Rates of anticoagulation use were examined during the early (<= 60 days post-discharge), mid-term (61–180 days post-discharge) and long-term (181–360 days post-discharge) periods. Multivariable logistic regression analysis was performed to identify patient- and surgery-related factors associated with long-term anticoagulant use. Anticoagulants were supplied to 20% of arthroplasties within 60 days of discharge, 7% between 61–180 days, and 10% between 181–360 days. Older age, obesity, increased comorbidity burden, a longer length of stay, occurrence of a complication necessitating anticoagulation and dispensation of an anticoagulant within 60 days of discharge were all risk factors for long-term anticoagulant use. Given the risks associated with unnecessary use of these medications, certain patients who are prescribed anticoagulants beyond prophylactic period may benefit from specialist medication review in the months following surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 39 - 39
7 Nov 2023
Crawford H Mcdonald A Boyle M Byrnes C
Full Access

This study aimed to identify long-term physical and psychosocial health outcomes in children with overwhelming musculoskeletal sepsis. Children admitted to the Paediatric Intensive Care Unit (PICU) from 1st January 2002 to 31st December 2017 with a musculoskeletal focus of infection were identified. A medical notes review was completed to determine survival and morbidity. Present-day clinical assessment of the musculoskeletal and respiratory systems along with questionnaires on health-related quality of life, mental health and sleep were performed. 70 patients were identified over 15 years. Seven children died acutely (five Pasifika and two Māori children) indicating 10% mortality. Recurrence/chronic infection affected 23%. Growth disturbance affected 18%. The hip joint and proximal femur suffered the worst long-term complications. Children under 2 years most at risk of long-term disability. No patients had chronic respiratory illness beyond 90 days. Fifteen children had symptoms of acute neurological impairment, three of whom had permanent acquired brain injury. Twenty-six survivors (41%) were assessed a mean of 8.2 years (SD 4.5, range 2– 18 years) after discharge. Health-related quality of life scores were on par with normative data. All patients who underwent pulmonary function tests had normal results. Six patients and eight parents screened positive for moderate to severe post-traumatic stress disorder. Paediatric multifocal musculoskeletal sepsis can result in complex illness with multi-organ complications for some children. Māori and Pasifika children are most at risk. Children under 2 years and those with proximal femur and/or hip involvement are most likely to have chronic musculoskeletal sequelae and permanent disability. Other outcomes are favourable with no evidence of chronic lung disease or mean reduced quality of life. A period of rehabilitation for children with identified acquired brain injury should be part of discharge planning


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 22 - 22
22 Nov 2024
Söderquist B Möller M Salihovic S
Full Access

Aim. Dalbavancin is a lipoglycopeptide with a broad antimicrobial spectrum against Gram-positive bacteria and effect against microorganisms in biofilm in vitro. Its pharmacokinetic properties, with an exceptionally long half-life of approximately 300 hours, allow for simplified administration that may be of value in the long-term treatment of bone and joint infections, such as prosthetic joint infections (PJIs). Several case reports and case series with “off-lable” treatment with dalbavancin of PJIs exist, but the optimal dosing regimen remains to be defined. Therapeutic drug monitoring (TDM) is recommended for treatment with >2 doses of dalbavancin. In the absence of TDM, the Swedish national guidelines for bone and joint infections (2023, . www.infektion.net. ) recommends a loading dose of dalbavancin 1,500 mg on day 1 and 1,500 mg on days 8 – 14, after which from day 28 1,000 mg is given biweekly or 500 mg every week. The aim of the present study was to determine trough levels of dalbavancin in patients with long-term treatment of PJIs according to the national guidelines. Method. Twelve patients with PJI were treated with at least 6 doses of dalbavancin, of which the first two doses were 1500 mg and the following doses were 1000 every second week, and prospectively sampled biweekly for determination of serum concentrations (trough levels) of dalbavancin which was measured by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-MS/MS). The renal function was also examined. Results. The median serum concentration 14 days after the first dose of dalbavancin 1500 mg was 36.3 mg/L (range 6.6 – 62.4 mg/L). The median value 14 days after the second dose of 1500 mg (day 27 – 28) was 48.2 mg/L (range 12.2 – 77.3 mg/L). The trough value after the last dose of a total of 6 – 7 doses was as median 43.1 mg/L (range 26.2 – 97.5 mg/L). Three patients showed a tendency towards successive accumulation of dalbavancin during treatment. None of the patients, including those three with increasing through levels during treatment, showed any significant alteration in creatinine nor glomerular filtration rate. Conclusions. TDM during long-term treatment with dalbavancin is recommended to avoid the risk of accumulation and unnecessarily high trough values. With TDM, the dosing interval can be extended in several cases. In addition, with the support of TDM, subtherapeutic serum concentrations, with the risk of developing resistance, can be avoided


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 48 - 48
24 Nov 2023
Dos Santos MV Meller S Perka C Trampuz A Renz N
Full Access

Aim. Antimicrobial suppression has shown to significantly improve treatment success of streptococcal periprosthetic joint infection (PJI) compared to 12-week standard antimicrobial therapy, however, only short-term follow-up was investigated. In this study we assessed the impact of suppression on the long-term outcome of streptococcal PJI. Method. Consecutive patients with streptococcal PJI (defined by EBJIS criteria) treated 2009–2021 were prospectively included and allocated into standard and suppression (> 6 months) treatment group. Infection-free survival was assessed with Kaplan-Meier-method and compared between the groups with log rank test. Rates of infection-free, streptococcal infection-free and relapse-free status as well as tolerability of suppression were assessed. Results. Sixty-three PJI episodes (36 knee, 26 hip and one shoulder prosthesis) of patients with a median age of 70 (35–87) years were included. Twenty-seven (43%) were females. Predominant pathogens were S. agalactiae (n=20), S. dysgalactiae (n=18) and S. mitis/oralis (n=13). The main surgical procedures used were two-stage exchange (n=35) and prosthesis retention (n=21). Standard 12-week treatment was administered in 33 patients and suppression in 30 patients, of whom 10 had ongoing suppression and 20 had discontinued antibiotics at time of follow-up. Used oral antibiotics for suppression were amoxicillin (n=29), doxycycline (n=5) and clindamycin (n=2); 6 patients changed antibiotic substance due to side effects. The median follow-up time was 3.9 (0.3–13.3) years. Infection-free survival after 7.5 years was 38% with standard treatment and 62% with suppression (p=0.038). Of all failures, 52% (14/27) were due to streptococci. Suppression was effective in preventing streptococcal infection for the duration of antimicrobial treatment, however, after discontinuation relapses or new infections due to streptococci occurred in 5/20 (25%) patients and infection with any Streptococcus spp. was observed in 9/19 (47%) failures with standard treatment, 5/6 (83%) failures after discontinuing suppression and none during suppression. All failures in patients with ongoing suppression were caused by gram-negative rods. Conclusion. At long-term follow-up, the success rate was superior with suppression compared to standard treatment. Most failures after stopping suppression were caused by streptococci, whereas failures under suppression were caused by aerobic gram-negative rods


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 8 - 8
1 Nov 2022
Bharmal A Gokhale N Curtis S Prasad G Bidwai A Kurian J
Full Access

Abstract. Background. To determine the long-term survival outcomes of Copeland Resurfacing Hemiarthroplasty (CRHA) performed by a single surgeon series. Methods. A retrospective cohort study which looked at patients who underwent CRHA over 6 years. Re-operations including revisions with component exchange taking place in our hospital and at local centres were reviewed. Oxford Shoulder Score (OSS) was used to assess their functional outcomes pre- and post-CRHA. Results. 80 CRHAs were performed in 72 patients between 2007 and 2013 with a mean follow-up of 6.5 years. The mean follow-up was 79 months (50–122). The primary indication for CRHA was osteoarthritis (76.3%), cuff tear arthropathy (16.3%), rheumatoid arthritis (5%) and post-trauma (1.3%). The mean pre-operative OSS was 16, which doubled following CRHA surgery. Fifteen patients underwent revision surgery due to ongoing glenoid pain with a mean revision time following primary CRHA being 49 months. Projected survival at the endpoints 5,7 and 10 years were 83, 81 and 79% respectively. Conclusion. This study provides us with a much longer average follow-up period in comparison to many other studies published. Previous studies, support resurfacing as a useful implant in reducing pain and improving function in the short-term; but this series demonstrates over the medium-term a relatively high revision rate of about 20% in comparison with other arthroplasty options, despite the revision rate seeming to plateau from the 5-year mark onwards


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 15 - 15
1 Dec 2021
Müller SLC Morgenstern M Kühl R Muri T Kalbermatten D Clauss M Schaefer D Sendi P Osinga R
Full Access

Aim. Fracture-related infection (FRI) is a severe post-traumatic complication which can be accompanied with a soft-tissue defect or an avital soft-tissue envelope. In these cases, a thoroughly planned orthoplastic approach is imperative since a vital soft-tissue envelope is mandatory to achieve fracture union and infection eradication. The aim of our study was to analyse plastic surgical aspects in the management of FRIs, including the type and outcome of soft-tissue reconstruction (STR), and to investigate the long-term outcome of FRI after STR. Method. Patients with a lower leg FRI requiring STR that were treated from 2010 to 2018 at our center were included in this retrospective analysis. STR involved the use of local, pedicled and free flaps. The primary outcome was the success rate of STR, and the secondary outcome was long-term fracture consolidation and cure of infection. Results. Overall, 145 patients with lower leg FRI were identified, of whom 58 (40%) received STR. Muscle flaps were applied in 38, fascio-cutaneous flaps in 19 and a composite osteo-cutaneous flap in one case. All patients underwent successful STR (primary STR in 51/58 patients, 7/58 patients needed secondary STR). A high Charlson Comorbidity Index Score was a significant risk factor for flap failure (p=0.011). Patients with free-flap STR developed significantly more severe complications and needed more surgical interventions (Clavien-Dindo ≥IIIa; p=0.001). Out of the 43 patients that completed long-term follow-up (mean 24 months), fracture consolidation was achieved in 32 and infection eradication in 31. Polymicrobial infection was a significant risk factor for fracture non-union (p=0.002). American Society of Anesthesiologists (ASA) classification of 3 or higher (p=0.040) was a risk factor for persistence or recurrence of infection. Conclusions. In our population, 58/145 patients with FRI required STR. STR was successful in all patients eventually, in 7/58 patients secondary STR was necessary. Therefore, STR should be sought even if primary STR fails. Despite successful STR, the long-term composite outcome showed a high rate of failed fracture consolidation and failed eradication of infection, which was independent of primary STR failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 14 - 14
10 Feb 2023
Vertesich K Staats K Böhler C Koza R Lass R Giurea A
Full Access

The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty. Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode. KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates. Long-term functional and clinical results proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 57 - 57
1 Dec 2022
Gazendam A Ekhtiari S Wood T Petruccelli D Tushinski D Winemaker MJ de Beer J
Full Access

The Accolade®TMZF is a taper-wedge cementless metaphyseal coated femoral stem widely utilized from 2002-2012. In recent years, there have been reports of early catastrophic failure of this implant. Establishing a deeper understanding of the rate and causes of revision in patients who developed aseptic failure in stems with documented concerns about high failure rates is critical. Understanding any potential patient or implant factors which are risk factors for failure is important to inform both clinicians and patients. We propose a study to establish the long-term survival of this stem and analyze patients who underwent aseptic revision to understand the causes and risk factors for failure. A retrospective review was undertaken of all patients who received a primary total hip arthroplasty with an Accolade® TMZF stem at a high-volume arthroplasty center. The causes and timing of revision surgery were documented and cross referenced with the Canadian Institute of Health Information Discharge Abstract Database to minimize loss to follow-up. Survivorship analysis was performed with use of the Kaplan-Meier curves to determine the overall and aseptic survival rates at final follow-up. Patient and implant factors commonly associated with aseptic failure were extracted and Cox proportional hazards model was used. A consecutive series of 2609 unilateral primary THA patients implanted with an Accolade®TMZF femoral hip stem were included. Mean time from primary surgery was 12.4 years (range 22 days to 19.5 years). Cumulative survival was 96.1% ± 0.2 at final follow-up. One hundred and seven patients underwent revision surgery with aseptic loosening of the femoral component was the most common cause of aseptic failure in this cohort (33/2609, 1.3%). Younger age and larger femoral head offset were independent risk factors for aseptic failure. To our knowledge, this is the largest series representing the longest follow-up of this taper-wedge cementless femoral implant. Despite early concerns, the Accolade® TMZF stem has excellent survivorship in this cohort. Trunnionosis as a recognized cause for revision surgery was rare. Younger age and larger femoral head offset were independent risk factors for aseptic failure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 32 - 32
1 Dec 2022
Fransen B Bengoa F Neufeld M Sheridan G Garbuz D Howard L
Full Access

With the introduction of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA), orthopaedic surgeons have moved towards using larger femoral heads at the cost of thinner liners to decrease the risk of instability. Several short and mid-term studies have shown minimal liner wear with the use HXLPE liners, but the safety of using thinner HXPLE liners to maximize femoral head size remains uncertain and concerns that this may lead to premature failure exist. Our objective was to analyze the outcomes for primary THA done with HXLPE liners in patients who have a 36-mm head or larger and a cup of 52-mm or smaller, with a minimum of 10-year follow-up. Additionally, linear and volumetric wear rates of the HXLPE were evaluated in those with a minimum of seven-year follow-up. We hypothesized that there would be minimal wear and good clinical outcome. Between 2000 and 2010, we retrospectively identified 55 patients that underwent a primary THA performed in a high-volume single tertiary referral center using HXLPE liners with 36-mm or larger heads in cups with an outer diameter of or 52-mm or smaller. Patient characteristics, implant details including liner thickness, death, complications, and all cause revisions were recorded. Patients that had a minimum radiographic follow-up of seven years were assessed radiographically for linear and volumetric wear. Wear was calculated using ROMAN, a validated open-source software by two independent researchers on anteroposterior X-rays of the pelvis. A total of 55 patients were identified and included, with a mean age of 74.8 (range 38.67 - 95.9) years and a mean BMI of 28.98 (range 18.87 - 63-68). Fifty-one (94.4%) of patients were female. Twenty-six (47.7%) patients died during the follow-up period. Three patients were revised, none for liner wear, fracture or dissociation. Twenty-two patients had a radiographic follow-up of minimum seven years (mean 9.9 years, min-max 7.5 –13.7) and were included in the long-term radiographic analysis. Liner thickness was 5.5 mm at 45 degrees in all cases but one, who had a liner thickness of 4.7mm, and all patients had a cobalt-chrome head. Cup sizes were 52mm (n=15, 68%) and 50mm (n=7, 32%). Mean linear liner wear was 0.0470 mm/year (range 0 - 0.2628 mm) and mean volumetric wear was 127.69 mm3/year (range 0 - 721.23 mm3/year). Using HXLPE liners with 36-mm heads or bigger in 52-mm cups or smaller is safe, with low rates of linear and volumetric wear in the mid to long-term follow-up. Patients did not require revision surgery for liner complications, including liner fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads should outweigh the potential risks of using thin HXLPE liners


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 31 - 31
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 – 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 56 - 56
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 - 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 42 - 42
1 Dec 2022
Fransen B Howard L MacDonell T Bengoa F Garbuz D Sheridan G Neufeld M
Full Access

Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the long-term survival and revision rates of HXLPE liners in primary THA, as well as the effect of liner thickness on these outcomes. We hypothesized that there would be no significant differences between the different liner thicknesses. We performed a retrospective database analysis from a single center of all primary total hip replacements using HXLPE liners from 2010 and earlier, including all femoral head sizes. All procedures were performed by fellowship trained arthroplasty surgeons. Patient characteristics, implant details including liner thickness, death, and revisions (all causes) were recorded. Patients were grouped for analysis for each millimeter of PE thickness (e.g. 4.0-4.9mm, 5.0-5.9mm). Kaplan-Meier survival estimates were estimated with all-cause and aseptic revisions as the endpoints. A total of 2354 patients (2584 hips) were included (mean age 64.3 years, min-max 19-96). Mean BMI was 29.0 and 47.6% was female. Mean follow-up was 13.2 years (range 11.0-18.8). Liner thickness varied from 4.9 to 12.7 mm. Seven patients had a liner thickness <5.0mm and 859 had a liner thickness of <6.0mm. Head sizes were 28mm (n=85, 3.3%), 32mm (n=1214, 47.0%), 36mm (n=1176, 45.5%), and 40mm (n=109, 4.2%), and 98.4% were metal heads. There were 101 revisions, and in 78 of these cases the liner was revised. Reason for revision was instability/dislocation (n=34), pseudotumor/aseptic lymphocyte-dominant vasculitis associated lesion (n=18), fracture (n=17), early loosening (n=11), infection (n=7), aseptic loosening (n=4), and other (n=10). When grouped by liner thickness, there were no significant differences between the groups when looking at all-cause revision (p=0.112) or aseptic revision (p=0.116). In our cohort, there were no significant differences in all-cause or aseptic revisions between any of the liner thickness groups at long-term follow-up. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA does not lead to increased complications or liner failures at medium to long term follow-up. As such, orthopedic surgeons can consider the use of larger heads at the cost of liner thickness a safe practice to reduce the risk of dislocation after THA when using HXLPE liners


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 53 - 53
1 Mar 2021
Cheng O Law N Tulk J
Full Access

A significant proportion of patient transfers in Ontario are from long-term care facilities for consultation of musculoskeletal (MSK) issues. These transfers are costly for patients and the healthcare system. This study evaluated the utility of a Telemedicine MSK (TeleMSK) service for long-term care patients requiring an orthopaedic consultation. A cross-sectional study was used to assess TeleMSK from September 2018 to April 2019. 26 long-term care facilities participated in this study, which included 32 long-term care patients assessed via TeleMSK and 27 telemedicine liaisons. Telemedicine Satisfaction Scale (TeSS) and the Telemedicine Usability Questionnaire (TUQ) surveys were used to evaluate the usefulness of the TeleMSK program. Patients and families rated voice (64.3%) and visual (71.4%) quality of TeleMSK to be excellent as well as the length of consultation (92.9%). 78.6% participants rated explanations from physicians to be excellent, 92.9% of the participants rated the carefulness, skillfulness, respect, and sensitivity of the attending physician to be excellent (85.7%). Patients felt privacy and confidentiality was maintained and respected throughout the consultation. The majority of telemedicine liaisons agreed that TeleMSK improved accessibility and productivity of consultations and 81.5% of the telemedicine liaisons strongly agreed that they would use TeleMSK again in the future. TeleMSK allowed for accessible, timely orthopaedic consultations without compromising the quality of patient care. Patients, families, and telemedicine liaisons rated their experience and use of TeleMSK as excellent. Barriers to healthcare are important issues to be addressed in the long term care population. This can be conducted efficiently and effectively with Telemedicine


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 86 - 86
1 Oct 2022
McNally M Ferguson J Scarborough M Ramsden A Stubbs D Atkins B
Full Access

Aim. Excision of chronic osteomyelitis (cOM) creates a dead space which must be managed to avoid early recurrence of infection. Systemic antimicrobials cannot penetrate this space in high concentration so local therapy has become an attractive adjunct to surgery. This study presents the mid- long-term results of local therapy with gentamicin in a bioabsorbable ceramic carrier. Method. A prospective series of 100 patients with Cierny & Mader Types III and IV cOM, affecting 105 bones, were treated with a single stage procedure, including debridement, deep tissue sampling, local and systemic antimicrobials, stabilization and immediate skin closure. cOM was confirmed with strict diagnostic criteria. Patients were followed up for a mean of 6.05 years (range 4.2–8.4 years). Results. At final follow-up, 6 patients had evidence of recurrent infection (94% infection-free). 3 infections recurred in the first year, with 2 in the second year and one at 4.5 years after surgery. Recurrence was not dependent on host physiological class (1/20 Class A; 5% vs 5/80 Class B; 6.25%. p=0.833). Nor was it related to aetiology of the infection, microbial culture or the presence of an infected non-union before surgery (1/10 with non-union; 10% vs 5/90 without non-union; 5.6%. p=0.57). Organisms which demonstrated intermediate or high-grade resistance to gentamicin were more likely in polymicrobial infections (9/21; 42.8%) compared to single isolate osteomyelitis (7/79; 8.9%)(p<0.001). However, recurrence was not more frequent when a resistant organism was present (1/16; 6.25% for resistant cases vs 5/84; 5.95% in sensitive culture infection) (p=0.96). Conclusions. This study shows that the single stage protocol, including a high delivery local antibiotic ceramic, was effective over several years. The method can be applied to a wide range of patients, including those with significant comorbidities and infected non-union


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 32 - 32
1 Mar 2021
Lapner P McRae S Leiter J McIlquham K MacDonald P
Full Access

Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. No previous comparative trials have reported on the long-term follow-up of single and double row fixation in arthroscopic cuff repair. The purpose of this study was to compare the long-term functional outcomes of single-row and double-row suture techniques for repair of the rotator cuff 10-years post-operatively. Ninety patients undergoing arthroscopic rotator cuff repair were randomized to receive either single-row or double-row repair. The primary objective was to compare the Western Ontario Rotator Cuff Index (WORC) score 10-years post-operatively. Secondary objectives included comparison of the Constant, and American Shoulder and Elbow Surgeons (ASES) scores and supraspinatus strength between groups. Out of 90 patients originally randomized, 57 returned for the long-term 10-year follow-up. Baseline demographic data did not differ between groups. The WORC score was not significantly different between groups at long-term follow-up (p=0.13). No statistical differences were observed between groups for the Constant (p=0.51), ASES (p=0.48) scores, or strength scores (p=0.93). A significant improvement was observed between pre-operative and the final 10-year follow-up. There were no differences observed in all outcomes between two and 10-years post-operatively. No statistically significant differences in functional or quality of life outcomes were identified between single-row and double-row fixation techniques at long-term follow-up


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 15 - 15
1 Apr 2022
Belousova E Pozdeev A Sosnenko O
Full Access

Introduction. Deformations of forearm with different degree of expression and functional restrictions of upper limb in children with hereditary multiple exostosis are formed in almost 80% of the cases. The question of indications for the selection and conduct of surgical procedure remains controversial, existing treatment methods and post-operative recovery methods for children need to be improved. Materials and Methods. The long-term outcomes of surgical treatment of 112 patients diagnosed with “Hereditary Multiple Exostosis” (HME) aged from 2 till 17 years old were researched. Evaluation of surgical treatment results was carried out in accordance with complaints, functional condition of the forearm, radiographs (taking into account reference lines and angles). Depending on the variant of deformation, the following surgical operations were performed: resection of bone-cartilage exostoses (in 20.5%); correction of forearm deformation with external fixator (in 79.5). In 14 cases, for a more accurate correction of deformity a hexapod frame was used. Results. Differentiated approach provided “good” anatomical and functional results in 55.6%; “satisfactory” results in 40.2%; “unsatisfactory” results in 4.2%. Postoperative complications in the form of non-union, pseudoarthrosis, delayed consolidation or neurological disorders were in 6.2%. Conclusions. The choice of surgical treatment is determined by the variant and severity of deformation. This approach allows to improve cosmetic and functional condition of forearm and adjacent joints. The use of hexapod allows to increase accuracy of correction of physiological axis of forearm bones


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 20 - 20
7 Nov 2023
Mackinnon T Hayter E Samuel T Lee G Huntley D Hardman J Anakwe R
Full Access

We have previously reported on the medium-term outcomes following a non-operative protocol of a short period of splinting followed by early movement to treat simple dislocations of the elbow. We undertook extended follow up of our original patient study group to determine whether the excellent results previously reported were maintained in the very long-term. A secondary question was to determine the rate and need for any late surgical intervention. We attempted to contact all patients in the original patient study group. Patients were requested to complete the Oxford elbow score (OES), the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and a validated patient satisfaction questionnaire. Patients were requested to attend a face-to-face assessment where they underwent a clinical examination including neurovascular assessment, range-of-motion and an assessment of ligamentous stability. Seventy-one patients (65%) from the original patient study group agreed to participate in the study. The mean duration of follow-up was 19.3 years. At final follow-up patients reported excellent functional outcome scores and a preserved functional range of movement in the injured elbows. The mean DASH score was 5.22 points and the mean Oxford Elbow Score was 91.6 points. The mean satisfaction score was 90.9 points. Our study shows that the excellent outcomes following treatment with a protocol of a short period of splinting and early movement remain excellent and are maintained into the very long term. These findings support our hypothesis that this treatment protocol is appropriate and suitable for most patients with simple dislocations of the elbow. The role for primary ligamentous repair for this patient group should be carefully considered. Work to more clearly define the anticipated benefits of surgery for specific patient groups or injury patterns would help to support informed decision making


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 12 - 12
1 Mar 2021
Glazebrook M Baumhauer J Younger A Fitch D Quiton J Daniels T DiGiovanni C
Full Access

Autologous bone has been the gold standard for grafting material in foot and ankle arthrodesis. While autograft use has been effective, the harvest procedure does present risks to the patient including readmission, infection, and persistent graft harvest site pain. Previous studies have examined graft harvest site pain, but most have focused on the iliac crest and none have long term follow-up. The purpose of this study was to examine long-term (7–10 year) harvest site pain in subjects undergoing autograft harvest from multiple sites for hindfoot and/or ankle arthrodesis. Sixty (60) subjects underwent hindfoot or ankle arthrodesis supplemented with autograft as part of the control arm of a prospective, randomized trial. The mean subject age was 59.4 years (range, 24.7–76.8) and mean body mass index was 30.6 kg/m2 (range, 22.0–44.0). There were 29 males and 31 female subjects. Subjects had the tibiotalar (37.9%), subtalar (24.1%), talonavicular (10.3%), subtalar/talonavicular (5.1%), or subtalar/calcaneocuboid/talonavicular (22.4%) joints arthrodesed. Autograft was harvested from either the proximal tibia (51.7%), iliac crest (17.2%), calcaneous (15.5%), distal tibia (6.8%), or other location (8.6%). Graft harvest site pain was evaluated using a 100-point visual analog score (VAS), with clinically significant pain being any score greater than 20. Subjects were followed a mean of 9.0 years (range, 7.8–10.5). The percentage of subjects who reported clinically significant pain was 35.7%, 21.4%, 18.2%, 10.5%, 8.9%, and 5.2% at 2, 6, 12, 24, 52 weeks, and final follow-up (7.8–10.5 years), respectively. The mean VAS autograft harvest site pain at final follow-up was 4.4 (range, 0.0–97.0), with 37.9% of subjects reporting at least some pain. For three subjects (5%) with clinically significant pain (VAS >20) at final follow-up, two had proximal tibial harvest sites and one had an iliac crest harvest site. There was no correlation between graft volume and harvest site pain. This study is the first to examine long-term pain following autologous bone graft harvest for hindfoot and/or ankle arthrodesis. Over a third of patients reported having some pain at an average follow-up of nine years, with 5% experiencing clinically significant pain. The results of this study suggest that harvesting autograft bone carries a risk of persistent, long-term pain regardless of the volume of graft that is harvested. This potential for persistent pain should be considered when informing patients of procedure risks and when deciding to use autograft or a bone graft substitute material


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1095 - 1100
1 Sep 2022
McNally MA Ferguson JY Scarborough M Ramsden A Stubbs DA Atkins BL

Aims. Excision of chronic osteomyelitic bone creates a dead space which must be managed to avoid early recurrence of infection. Systemic antibiotics cannot penetrate this space in high concentrations, so local treatment has become an attractive adjunct to surgery. The aim of this study was to present the mid- to long-term results of local treatment with gentamicin in a bioabsorbable ceramic carrier. Methods. A prospective series of 100 patients with Cierny-Mader Types III and IV chronic ostemyelitis, affecting 105 bones, were treated with a single-stage procedure including debridement, deep tissue sampling, local and systemic antibiotics, stabilization, and immediate skin closure. Chronic osteomyelitis was confirmed using strict diagnostic criteria. The mean follow-up was 6.05 years (4.2 to 8.4). Results. At final follow-up, six patients (six bones) had recurrent infection; thus 94% were infection-free. Three infections recurred in the first year, two in the second year, and one 4.5 years postoperatively. Recurrence was not significantly related to the physiological class of the patient (1/20 Class A (5%) vs 5/80 Class B (6.25%); p = 0.833), nor was it significantly related to the aetiology of the infection, the organisms which were cultured or the presence of nonunion before surgery (1/10 with nonunion (10%) vs 5/90 without nonunion (5.6%); p = 0.570). Organisms with intermediate or high-grade resistance to gentamicin were significantly more likely in polymicrobial infections (9/21; 42.8%) compared with monobacterial osteomyelitis (7/79 (8.9%); p < 0.001). However, recurrence was not significantly more frequent when a resistant organism was present (1/16 for resistant cases (6.25%) vs 5/84 in those with a microbiologically sensitive infection (5.95%); p = 0.958). Conclusion. We found that a single-stage protocol, including the use of a high-delivery local antibiotic ceramic carrier, was effective over a period of several years. The method can be used in a wide range of patients, including those with significant comorbidities and an infected nonunion. Cite this article: Bone Joint J 2022;104-B(9):1095–1100


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 67 - 67
1 Dec 2021
Walter N Rupp M Hierl K Koch M Kerschbaum M Worlicek M Alt V
Full Access

Aim. We aimed to evaluate the impact of knee periprosthetic joint infection (PJI) by assessing the patients’ long-term quality of life and explicitly their psychological wellbeing after successful treatment. Method. Thirty-six patients with achieved eradication of infection after knee PJI were included. Quality of life was evaluated with the EQ-5D and SF-36 outcome instruments as well as with an ICD-10 based symptom rating (ISR) and compared to normative data. Results. At a follow-up of 4.9± 3.5 years the mean SF-36 score was 24.82± 10.0 regarding the physical health component and 46.16± 13.3 regarding the mental health component compared to German normative values of 48.36± 9.4 (p< .001) and 50.87± 8.8 (p= .003). The mean EQ-5D index reached 0.55± 0.33 with an EQ-5D VAS rating of 52.14± 19.9 compared to reference scores of 0.891 (p< .001) and 68.6± 1.1 (p< .001). Mean scores of the ISR revealed psychological symptom burden on the depression scale. Conclusions. PJI patients still suffer from significant lower quality of life compared to normative data even years after surgically successful treatment. Future clinical studies should focus on patient-related outcome measures. Newly emerging treatment strategies, prevention methods and interdisciplinary approaches should be implemented to improve the quality of life of PJI patients