Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans.

Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 437 - 437
1 Sep 2012
Kobbe P Hockertz I Sellei R Reilmann H Hockertz T
Full Access

Sacroiliac screw fixation is the method of choice for the definitive treatment of unstable posterior pelvic ring injuries; however this technique is demanding and associated with a high risk of iatrogenic neurovascular damage. We therefore evaluated the outcome, complications, surgical and fluoroscopy time for unstable posterior pelvic ring injuries managed with a transiliac locked compression plate.

23 patients were managed with a transiliac locked compression plate for unstable posterior pelvic injuries at a Level I Trauma Center. 21 patients were available for follow up after an average of 30 months and outcome evaluation was performed with the Pelvic Outcome Score, which is composed of a clinical, radiological, and social integration part.

The overall outcome for the pelvic outcome score was excellent in 47.6% (10 patients), good in 19% (4 patients), fair in 28.6% (6 patients) and poor in 4.8% (1 patient). 15 out of 21 patients (71.4%) returned to their normal life, 3 patients (14.3%) were limited at work, and 3 patients (14.3%) were not able to return to work due to their disabilities. The social status was unchanged to the preinjury status in 19 patients (90.5%). 13 patients (62%) stated no changes in spare time and sports activities; 4 patients (19%) had minor and another 4 patients (19%) had major restrictions. The average operation time was 101 min and intraoperative fluoroscopic time averaged 74.2 sec. No iatrogenic neurovascular injuries were observed.

Posterior percutaneous plate osteosynthesis may be a good alternative to sacral screw fixation because it is quick, safe, and associated with a good functional outcome.