Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 26 - 26
1 Oct 2022
Vles G Bossen J Kloos J Debeer P Ghijselings S
Full Access

Aim

A septic revision of an artificial joint is routinely split up in a so-called dirty phase and a clean phase. The measures taken to initiate the start of the clean phase vary significantly between musculoskeletal infection centers. We performed simulations of one-step exchanges of infected THAs and sought to 1) determine the effect of different clean phase protocols on the sterile field, and 2) determine whether or not it is possible to re-implant the new prosthesis completely clean.

Method

Nine fresh frozen cadaveric hips were used and primary THA was undertaken via a direct anterior approach. Before implantation of the components varying amounts of fluorescent powder (GloGerm) were deposited, simulating bacterial infection. Second, a one-step exchange was performed via a posterolateral approach. After implant removal, debridement, and lavage, randomization determined which clean phase protocol was followed, i.e. no, some or full additional measures. Finally, the new prosthesis was re-implanted (fig. 1).

In order to determine the effect of different clean phase protocols on contamination of the sterile field standardized UV light-enhanced photographs were obtained of 1) the gloves, 2) the instrument table, 3) the drapes, and 4) the wound and these were ranked on cleanliness by a blind panel of hip surgeons.

In order to determine whether or not it is possible to re-implant the prosthesis completely clean, the implant was taken out again at the end of the one-step exchange and inspected for contamination under UV light.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 22 - 22
1 May 2019
Romeo A
Full Access

Patient perceptions regarding the functional outcomes and return to sports after shoulder replacement are often pessimistic, with many patients presenting for shoulder replacement surgery after months or years of avoiding the procedure so they could continue to live the current life they have, despite the increasing pain and dysfunction. Less common, but becoming more frequent, patients present with expectations that they will be able to return to all activities including heavy resistance training, cross-fit, rock climbing, and other strenuous overhead sports. In the past, little information has been available regarding the activities of shoulder arthroplasty patients after surgery. Typically, the boundaries have been set by the surgeon, with many patients cautioned or even prohibited from overhead sports, weight training, or heavy work responsibilities. A typical set of guidelines may include no repetitive overhead sports, except for recreational swimming, and no lifting over 20 pounds. Golf, jogging, hiking and other activities are allowed.

The origin of these restricted guidelines and expectations is unknown, but many believe that since the results of shoulder replacements are less favorable in younger patients, it may be due to the overuse or abuse of the shoulder joint that is more typical at a younger age. Others have suggested that common sense prevails and that an artificial joint made of metal and plastic has a finite number of total movements and tolerance to resistance activities, and therefore keeping these activities at a minimum would extend the longevity of the artificial joint. None of these concepts are backed up by evidence-based literature, essentially reflecting the personal bias of the surgeons who care for patients with these problems. Despite all of the sophisticated research, scoring scales, outcome measures, and value-based metrics, the only outcome that really matters is whether the patient can return back to their normal way of life, at home, at work, during sport, or any activity that is important to them.

Recent studies of patients who have had joint replacement surgery have revealed that our patients who participated in sports and work activities before surgery have a strong predilection to returning to those activities after successful shoulder replacement. The most common sports that shoulder arthroplasty patients enjoy including golf, swimming, tennis, but may also include many other choices including fitness activities, rowing, skiing, basketball, and softball. As expected, the return to these sports is less for reverse shoulder arthroplasty patients vs. anatomic shoulder arthroplasty patients. In a systematic review, more than 90% of anatomic shoulder replacement patients returned to sport, while 75% of reverse shoulder arthroplasty patients returned to some sporting activity. This may reflect the constraints of the reverse prosthesis, or, quite possibly reflect the typically older age and more sedentary lifestyle of patients who are indicated for reverse shoulder arthroplasty. In addition, if the patient had a preoperative expectation of return to recreational and sports activities as part of their normal way of life, their final results demonstrated better overall outcomes.

Shoulder arthroplasty surgeons should be concerned about the outcomes desired by our patients, and the results that provide true value to their lives. We are now more aware of the activities that they are going to return to, whether we recommend restrictions or not.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 22 - 22
1 May 2013
Balakumar B Madhuri V
Full Access

Purpose

The correction obtained in the coronal plane knee deformity using guided growth was assessed in children with sick physes (Height<1SD of the normal children) to define the limits of this technique in sick physis

Methods

We retrospectively assessed deformity correction following guided growth using 8 plates in children with coronal plane deformity and metabolically abnormal physis- renal rickets in 6 and bone dysplasias (multiple epiphyseal dyspasia, spondyloepiphyseal dysplasia, metaphyseal dysplasia, mesomelic dysplasia, chondrodysplasia punctata) in 10 children aged 2 to 14 years. Lateral distal femoral angle(LDFA) and medial proximal tibia(MPTA) angles were serially assessed after eight plate application as a day care procedure. We noted correction achieved rate of correction, complications and additional surgical procedures. Fischer's exact test and multiple regression analysis was done to assess the effect of modifiers.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 52 - 52
1 May 2016
Stiegel K Ismaily S Noble P
Full Access

Introduction

Patients who undergo hip resurfacing, total hip arthroplasty (THA), and total knee arthroplasty (TKA) are frequently assessed post-operatively using objective scoring indices. A small yet significant percentage of these patients report specific unfulfilled functions following surgery, indicating unmet expectations. The purpose of this study was to examine the types of functional deficits reported for each class of surgery, how frequently these limitations occur, and the demographic of patients who experience/report these limitations.

Methods

Four groups of subjects were enrolled in this study: (i) 111 hip resurfacing patients at an average of 14 months after resurfacing, (ii) 170 patients at an average of 16 months post-primary THA, (iii) 61 patients at an average of 12 months post-primary TKA, and (iv) 64 control subjects with no history of hip or knee surgery or pathology. Each participant completed a self-administered Hip Function Questionnaire, Knee Function Questionnaire, or Hip Resurfacing Questionnaire which assessed each subject's overall satisfaction and expectations following surgery. The questionnaires included numerical scores of post-operative function as well as an open-ended question which inquired “Is there anything your knee/hip keeps you from doing?”


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 97 - 97
1 Dec 2013
Kaneyama R Shiratsuchi H Oinuma K Miura Y Higashi H Tamaki T Jonishi K
Full Access

Introduction:

Total knee arthroplasty (TKA) should aim to adjust the component gap (CG) difference between extension and flexion. However, this difference cannot be measured without placement of a femoral component. The bone gap reportedly decreases in extension after component setting. In contrast, it may be possible to use the mean value of the CG difference in several patients to adjust femoral resection amount beforehand. The purpose of this study is to evaluate the technique of adjusting CG difference using the mean values with measured resection technique (MRT) in TKA.

Materials and methods:

The subjects were 222 knees (40 male knees, 182 female knees; mean age 70.4 years). To adjust the CG difference after estimation, the femoral posterior condylar pre-cut technique was used. Extension gap was created by usual bone resection; 4 mm of the femoral posterior condyle was pre-cut, and after all osteophytes and soft tissues had been treated, a pre-cut trial component (thickness of 8 mm for distal femur and 4 mm for posterior condyle without the anterior portion) was mounted, achieving the same condition as the setting of a femoral component in MRT (Fig. 1). When the posterior cruciate ligament (PCL) could be easily preserved by intraoperative gap assessments, the PCL was preserved (190 knees, 86%).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 13 - 13
1 May 2013
Barker A Smitham P Scarsbrook C Calder P
Full Access

A statement of the purposes of the study

This study examined the stability of two different hexapod frames at increasing strut angles and the possible use of an additional strut to aid stability.

Introduction

Hexapod frames have certain advantages over standard circular frames, however disadvantages include a rattle and instability at some strut angles. This could be particularly important when larger diameter rings are used over a shorter distance resulting in lower ring strut angles such as in the femur.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 19 - 19
1 Jun 2023
Donnan U O'Sullivan M McCombe D Coombs C Donnan L
Full Access

Introduction. The use of vascularised fibula grafts is an accepted method for reconstructing the distal femur following resection of malignant childhood tumours. Limitations relate to the mismatch of the cross-sectional area of the transplanted fibula graft and thel ocal bone, instability of the construct and union difficulties. We present midterm results of a unique staged technique—an immediate defect reconstruction using a double-barrel vascularised fibula graft set in in A-frame configuration and a subsequent intramedullary femoral lengthening. Materials & Methods. We retrospectively included 10 patients (mean age 10 y)with an osteosarcoma of the distal femur, who were treated ac-cording to the above-mentioned surgical technique. All patients were evaluated with regards to consolidation of the transplanted grafts, hypertrophy at the graft-host junctions, leg length discrepancies, lengthening indices, complications as well as functional outcome. Results. The mean defect size after tumour resection was 14.5 cm, the mean length of the harvested fibula graft 22 cm, resulting in a mean (acute) shortening of 4.7 cm (in 8 patients). Consolidation was achieved in all cases, 4 patients required supplementary bone grafting. Hypertrophy at the graft-host junctions was observed in78% of the evaluable junctions. In total 11 intramedullary lengthening procedures in 9 patients had been performed at the last follow up. The mean Muskuloskeletal Society Rating Scale(MSTS) score of the evaluable 9 patients was 85% (57% to 100%)with good or excellent results in 7 patients. Conclusions. A-frame vascularised fibula reconstructions showed encouraging results with respect to defect reconstruction, length as well as function and should therefore be considered a valuable option for reconstruction of the distal femur after osteosarcoma resection. The surgical implementation is demanding though, which is emphasized by the considerable high number of com-plications requiring surgical intervention, even though most were not serious


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 34 - 34
1 Oct 2022
Dudareva M Corrigan R Hotchen A Muir R Scarborough C Kumin M Atkins B Scarborough M McNally M Collins G
Full Access

Aim. Smoking is known to impair wound healing and to increase the risk of peri-operative adverse events and is associated with orthopaedic infection and fracture non-union. Understanding the magnitude of the causal effect on orthopaedic infection recurrence may improve pre-operative patient counselling. Methods. Four prospectively-collected datasets including 1173 participants treated in European centres between 2003 and 2021, followed up to 12 months after surgery for clinically diagnosed orthopaedic infections, were included in logistic regression modelling with Inverse Probability of Treatment Weighting for current smoking status [1–3]. Host factors including age, gender and ASA score were included as potential confounding variables, interacting through surgical treatment as a collider variable in a pre-specified structural causal model informed by clinical experience. The definition of infection recurrence was identical and ascertained separately from baseline factors in three contributing cohorts. A subset of 669 participants with positive histology, microbiology or a sinus at the time of surgery, were analysed separately. Results. Participants were 64% male, with a median age of 60 years (range 18–95); 16% of participants experienced treatment failure by 12 months. 1171 of 1173 participants had current smoking status recorded. As expected for the European population, current smoking was less frequent in older participants (Table 1). There was no baseline association between Charlson score or ASA score and smoking status (p=0.9, p=1, Chi squared test). The estimated adjusted odds ratio for treatment failure at 12 months, resulting from current smoking at the time of surgery, was 1.37 for all participants (95% CI 0.75 to 2.50) and 1.53 for participants with recorded confirmatory criteria (95% CI 1.14 to 6.37). Conclusions. Smoking contributes to infection recurrence, particularly in people with unequivocal evidence of osteomyelitis or PJI. People awaiting surgery for orthopaedic infection should be supported to cease smoking, not only to reduce anaesthetic risk, but to improve treatment outcomes. Limitations of this study include unmeasured socioeconomic confounding and social desirability bias resulting in uncertainty in true smoking status, resulting in underestimated effect size


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 74 - 74
1 Dec 2022
Hoit G Khan R Chahal J Whelan DB
Full Access

Multiligament knee injuries (MLKI) are rare and life-altering injuries that remain difficult to treat clinically due to a paucity of evidence guiding surgical management and timing. The purpose of this study was to compare injury specific functional outcomes following early versus delayed surgical reconstruction in MLKI patients to help inform timing decisions in clinical practice. A retrospective analysis of prospectively collected data from patients with MLKIs at a single academic level 1-trauma center was conducted. Patients were eligible for inclusion if they had an MLKI, underwent reconstructive surgery either prior to 6wks from injury or between 12weeks and 2 years from injury, and had at least 12months of post-surgical follow-up. Patients with a vascular injury, open injuries or associated fractures were excluded. Study participants were stratified into early (12 weeks - 2 years from injury). The primary outcome was patient reported, injury specific, quality of life in the form of the Multiligament Quality of Life questionnaire (MLQOL) and its four domains (Physical Impairment, Emotional Impairment, Activity Limitations and Societal Involvement). We secondarily analyzed differences in the need for manipulation under anesthesia, and reoperation rates, as well as radiographic Kellgren Lawrence (KL) arthritis grades, knee laxity grading and range of motion at the most recent follow-up. A total of 131 patients met our inclusion criteria, all having had surgery between 2006 and 2019. There were 75 patients in the early group and 56 in the delayed group. The mean time to surgery was 17.6 ± 8.0 days in the early group versus 279 ± 146.5 days in the delayed. Mean postoperative follow-up was 58 months. There were no significant differences between early and delayed groups with respect to age (34 vs. 32.8 years), sex (77% vs 63% male), BMI (28.3 vs 29.7 kg/m2), or injury mechanism (p>0.05). The early surgery group was found to include more patients with lateral sided injuries (n=49 [65%] vs. n=23 [41%]; p=0.012), a higher severity of Schenck Classification (p=0.024) as well as nerve injuries at initial presentation (n=35 [49%] vs n=8 [18%]; p0.05), when controlling for age, sex, Schenck classification, medial versus lateral injury, and nerve injury status. In terms of our secondary outcomes, we found that the early group underwent significantly more manipulations under anesthesia compare with the delayed group (n=24, [32%] vs n=8 [14%], p=0.024). We did not identify a significant difference in physical examination laxity grades, range of motion, KL grade or reoperation rates between groups (p>0.05). We found no difference in patient reported outcomes between those who underwent early versus delayed surgery following MLKI reconstruction. In our secondary outcomes, we found significantly more patients in the early surgery group required a manipulation under anesthesia following surgery, which may indicate a propensity for arthrofibrosis after early MLKI reconstruction


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 51 - 51
1 Apr 2022
To C Robertson A Guryel E
Full Access

Introduction. Cerament, a bioresorbable hydroxyapatite and calcium sulfate cement, is known to be used as a bone-graft substitute in traumatic bone defect cases. However, its use in open fractures has not previously been studied. Materials and Methods. Retrospective, single-centre review of cases between November 2016 and February 2021. Open fractures were categorised according to the Orthopaedic Trauma Society classification (OTS). Cases were assessed for union, time to union, and associated post-operative complications. Results. Twenty-four patients were identified. Fifteen cases were classified as OTS simple open fractures, and nine cases were complex open fractures requiring soft tissue reconstruction. Four cases were lost to follow-up. Four cases had limited follow-up beyond 6 months but showed evidence of progressive radiographic union. Of the remaining 16 cases, eight cases (50%) went on to union with a mean time to union of 6.7 months (5 to 12 months). Persistent non-union remained in six cases (38%). Two cases required return to theatre due to an infected skin graft and wound dehiscence respectively. One case had the complication of persistent weeping of Cerament from the wound. This self-resolved within two weeks. Limitations of this case series include the lack of complete follow-up in eight patients (33%) and the lack of patient reported outcome measures. Conclusions. Cerament can be a useful adjunct in managing open fractures. However, it should be noted there is a high rate of non-union which may be reflective of the significant morbidity associated with open fractures with structural bone defects


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 3 - 3
1 Dec 2022
Hoit G Khan R Chahal J Whelan D
Full Access

Multiligament knee injuries (MLKI) are rare and life-altering injuries that remain difficult to treat clinically due to a paucity of evidence guiding surgical management and timing. The purpose of this study was to compare injury specific functional outcomes following early versus delayed surgical reconstruction in MLKI patients to help inform timing decisions in clinical practice. A retrospective analysis of prospectively collected data from patients with MLKIs at a single academic level 1-trauma center was conducted. Patients were eligible for inclusion if they had an MLKI, underwent reconstructive surgery either prior to 6wks from injury or between 12weeks and 2 years from injury, and had at least 12months of post-surgical follow-up. Patients with a vascular injury, open injuries or associated fractures were excluded. Study participants were stratified into early (<6wks from injury) and delayed surgical intervention (>12 weeks – 2 years from injury). The primary outcome was patient reported, injury specific, quality of life in the form of the Multiligament Quality of Life questionnaire (MLQOL) and its four domains (Physical Impairment, Emotional Impairment, Activity Limitations and Societal Involvement). We secondarily analyzed differences in the need for manipulation under anesthesia, and reoperation rates, as well as radiographic Kellgren Lawrence (KL) arthritis grades, knee laxity grading and range of motion at the most recent follow-up. A total of 131 patients met our inclusion criteria, all having had surgery between 2006 and 2019. There were 75 patients in the early group and 56 in the delayed group. The mean time to surgery was 17.6 ± 8.0 days in the early group versus 279 ± 146.5 days in the delayed. Mean postoperative follow-up was 58 months. There were no significant differences between early and delayed groups with respect to age (34 vs. 32.8 years), sex (77% vs 63% male), BMI (28.3 vs 29.7 kg/m. 2. ), or injury mechanism (p>0.05). The early surgery group was found to include more patients with lateral sided injuries (n=49 [65%] vs. n=23 [41%]; p=0.012), a higher severity of Schenck Classification (p=0.024) as well as nerve injuries at initial presentation (n=35 [49%] vs n=8 [18%]; p<0.001). Multivariable linear regression analyses of the four domains of the MLQOL did not demonstrate an independent association with early versus delayed surgery status (p>0.05), when controlling for age, sex, Schenck classification, medial versus lateral injury, and nerve injury status. In terms of our secondary outcomes, we found that the early group underwent significantly more manipulations under anesthesia compare with the delayed group (n=24, [32%] vs n=8 [14%], p=0.024). We did not identify a significant difference in physical examination laxity grades, range of motion, KL grade or reoperation rates between groups (p>0.05). We found no difference in patient reported outcomes between those who underwent early versus delayed surgery following MLKI reconstruction. In our secondary outcomes, we found significantly more patients in the early surgery group required a manipulation under anesthesia following surgery, which may indicate a propensity for arthrofibrosis after early MLKI reconstruction


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 53 - 53
1 Feb 2020
De Meo F Ascani D Cacciola G Bernardoni M Cavaliere P
Full Access

Preoperative planning is a crucial step for total hip arthroplasty (THA), and 2D X-ray images are commonly used. The planning aims to provide the correct implant size, restore functional biomechanical conditions and avoid early complication such as dislocation, leg length discrepancy or abductors insufficiency. Limitations of 2D planning, besides the low accuracy in sizing, concerns the inability of planning the anteversion of both acetabular and femoral component on axial plane. Also, the verification of the planning intraoperatively is wholly left to qualitative measurements and the surgeon's experience. The need for having a more accurate and functional preoperative planning has been addressed using 3D models. The MyHip Planner (MHP) (Medacta International, Castel San Pietro, Switzerland), is a preoperative planning software which through artificial intelligent algorithm converts the CT scans into a 3D model that perfectly match the patient's anatomy. Then, automatic positioning of the implants is performed following the personal settings of the surgeon which will check and validate the planning, a personalized simulation of six daily activities to detect impingement of implants and bones. The MyHip Verifier (MHV) intraoperatively verifies the execution of the planning in terms of leg length and offset using two fluoroscopic images. Also, the size and cup angles can be calculated. The purpose of the present study was to validate the accuracy of the MHP [Fig 1] and MHV [Fig 2]. The dataset consisted of 13 patients who underwent primary uncemented THA. Each patient had a preoperative CT scan, intraoperative fluoroscopy, and postoperative CT scan after the surgery. The CT protocol used was low radiation (0,2 mm slicing for the pelvis, 0,5 mm for knees and ankles). The patients have been preoperatively planned used the MPH, and the accuracy of the components size prediction has been evaluated by comparing the preoperative planned values with the surgical reports. The MVH calculated the leg length and offset in terms of the difference between the preoperative and postoperative position of the femur concerning the pelvis. The accuracy of the measurements has been evaluated using postoperative CT scans. The MPH was able to predict the implanted size in 83% of the patient for the femoral stem and 96% for the acetabular component. The accuracy of the MVH in measuring the leg length was under 2 mm (1,6 ± 0,7 mm) while the offset was 2,5±1,6 mm. The cup angles were 5±1,1deg and 2,3±1,3deg for the anteversion and inclination, respectively. The average cup anteversion was 28,3°, mean cup inclination was 42,6°; femoral offset and leg length was restored in 96,5% of patients within a range of ±3 mm concerning the preoperative position. The results demonstrated the reliability of the MPH in predicting the implant size, and the accuracy of the MVH to verify the execution of the plan intraoperatively. The two software can be used in the clinical routine to improve the clinical outcome in THA. Limitations of this study are represented mainly by the small cohort of patients involved. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 9 - 9
1 Jun 2021
Greene A Verstraete M Roche C Conditt M Youderian A Parsons M Jones R Flurin P Wright T Zuckerman J
Full Access

INTRODUCTION. Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes. METHODS. Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests. RESULTS. No significant differences were observed for the flexion/extension maneuver between the 38mm and 42mm liner sizes, but a significant difference was observed for every internal/external rotation assessment at 0°, 45°, and 90° of abduction. No significant differences were observed for the across the body and overhead maneuvers, but a significant difference was observed for the behind the back maneuver (p = 0.015). Standard deviations were pronounced across all maneuvers. CONCLUSION. This study observed significant differences in intraoperative load values in rTSA when comparing different humeral liner sizes. Limitations of this study include the small sample sizes and large standard deviations observed, as well as comparing across multiple patients and multiple surgeons. Area for future work includes comparing load values with postoperative functional results and complication risks for short, midterm, and long-term outcomes in efforts to find the optimal load range for a given patient


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 38 - 38
1 Feb 2021
Hickey M Anglin C Masri B Hodgson A
Full Access

Introduction. Innovations in surgical robotics and navigation have significantly improved implant placement accuracy in total knee arthroplasty (TKA). However, many comparative studies have not been shown to substantially improve revision rates or other clinical outcome scores. We conducted a simulation study based on the reported distribution of patient-specific characteristics and estimated potential effect of coronal plane alignment (CPA) on risk of revision to evaluate the hypothesis that most published study designs in this area have been too underpowered to detect improvements in revision rates. Methods. To model previously reported studies, we generated a series of simulated TKA patient populations, assigning each patient a set of patient-specific factors (age at index surgery, BMI, and sex (Fig.1a)), as well as one surgeon-controlled factor (CPA) (Fig.1b) based on registry data and published literature. We modelled the survival probability for an individual patient at time t as a Gaussian function (exp[-(t/(k∗τ. max. )). 2. ]), where τ. max. (99.5 years) is selected to ensure the mean survival probability of the patient population matched 92% at 15 years. The value of k was adjusted for simulated patients within a range of 0 to 1 as a function of their patient and surgeon-specific factors (Fig.2). To evaluate power associated with a study design, we ran a Monte Carlo simulation generating 10,000 simulated populations of ten different cohort sizes. We divided the patient population into two groups: one group was assigned CPAs governed by the precision of a navigated/robotic approach (σ=1.5°), and the other CPAs governed by the precision of a conventional approach (σ=3°). We then simulated the time to failure for each patient, computed the corresponding Kaplan-Meier survival curves, and applied a Log-Rank test to each study to test for statistical difference. From the 10,000 simulations associated with each cohort size, we determined the percentage of simulated studies that found a statistically significant difference at each time point. Results. Figure 3 shows a contour plot illustrating the probability that a survival analysis with a specific study design would find statistical significance between the conventional and navigated/robotic patient groups. Entries from recently published literature are overlaid for context. No studies achieved statistical significance (p<0.05). Discussion. The effectiveness of navigated/robotic surgery is one of the most controversial debates in orthopedic surgery. The results from this simulation suggest that most revision studies aiming to settle this debate are likely significantly underpowered, falling below the normal 80% threshold. Limitations of this analysis include using only a single surgeon-controlled variable in the survival simulation, and only a single precision for the navigated/robotic approaches. Further studies will include more implant-related risk factors and a wider range of precisions for navigated/robotic procedures. Based on this simulation, it appears the effect size afforded by navigated/robotic surgeries on revision rates in TKA surgery is too small to recommend broad application, especially since adoption could involve added costs and unforeseen risks associated with novelty. Clinically, it may be beneficial to examine the use of robotics/navigation on high-risk patients, where studies are likely to have higher power due to larger effect sizes. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 83 - 83
1 Feb 2020
Shimmin A Pierrepont J Bare J McMahon S
Full Access

Introduction & aims. Apparently well-orientated total hip replacements (THR) can still fail due to functional component malalignment. Previously defined “safe zones” are not appropriate for all patients as they do not consider an individual's spinopelvic mobility. The Optimized Positioning System, OPS. TM. (Corin, UK), comprises preoperative planning based on a patient-specific dynamic analysis, and patient-specific instrumentation for delivery of the target component alignment. The aim of this study was to determine the early revision rate from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) for THRs implanted using OPS. TM. . Method. Between January 4. th. 2016 and December 20. st. 2017, a consecutive series of 841 OPS. TM. cementless total hip replacements were implanted using a Trinity acetabular cup (Corin, UK) with either a TriFit TS stem (98%) or a non-collared MetaFix stem (2%). 502 (59%) procedures were performed through a posterior approach, and 355 (41%) using the direct superior approach. Mean age was 64 (range; 27 to 92) and 51% were female. At a mean follow-up of 15 months (range; 3 to 27), the complete list of 857 patients was sent to the AOANJRR for analysis. Results. There were 5 revisions: . a periprosthetic femoral fracture at 1-month post-op in a 70F. a ceramic head fracture at 12-months post-op in a 59M. a femoral stem loosening at 7-months post-op in a 58M. a femoral stem loosening at 16-months post-op in a 64M. an anterior dislocation in a 53M, that was revised 9 days after the primary procedure. CT analysis, prior to revision surgery, revealed acetabular cup orientation of 46°/31° (inclination/anteversion) and femoral stem anteversion of 38°. Conclusions. These preliminary findings suggest the OPS. TM. dynamic planning and delivery system provides good early results, with a low rate of revision for dislocation. Limitations of the study will be discussed


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 49 - 49
1 Jul 2020
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar MJ Turgeon T
Full Access

The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery. Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution. Supine RSA radiographs were obtained post-operatively and at 6-, 12-, and 24-months. Standing (weight-bearing) RSA radiographs were obtained at 12-months (n=45) and 24-months (n=48). All patients received the same knee design with a fixed, conventional PE insert of either a cruciate retaining or posterior stabilized design. Ethics approval for this study was obtained. In order to assess in vivo wear, a highly accurate 3-dimensional virtual model of each in vivo TKA was developed. Coordinate data from RSA radiographs (mbRSA v3.41, RSACore) were applied to digital implant models to reconstruct each patient's replaced knee joint in a virtual environment (Geomagic Studio, 3D Systems). Wear was assessed volumetrically (digital model overlap) on medial and lateral condyles separately, across each follow-up. Annual rate of wear was calculated for each patient as the slope of the linear best fit between wear and time-point. The influence of weight-bearing was assessed as the difference in annual wear rate between standing and supine exams. Age, BMI, and Oxford-12 knee improvement were measured against wear rates to determine correlations. Weight bearing wear measurement was most consistent and prevalent in the medial condyle with 35% negative wear rates for the lateral condyle. For the medial condyle, standing exams revealed higher mean wear rates at 1 and 2 years, supine, 16.3 mm3/yr (SD: 27.8) and 11.2 mm3/yr (SD: 18.5) versus standing, 51.3 mm3/yr (SD: 55.9) and 32.7 mm3/yr (SD: 31.7). The addition of weight-bearing increased the measured volume of wear for 78% of patients at 1 year (Avg: 32.4 mm3/yr) and 71% of patients at 2 years (Avg: 48.9 mm3/yr). There were no significant (95% CI) correlations between patient demographics and wear rates. Volumetric, weight-bearing wear measurement of TKR using model-based RSA determined an average of 33 mm3/yr at 2 years post-surgery for a modern, non-cross-linked polyethylene bearing. This value is comparable to wear rates obtained from retrieved TKRs. Weight-bearing exams produced better wear data with fewer negative wear rates and reduced variance. Limitations of this study include: supine patient imaging performed at post-op, no knee flexion performed, unknown patient activity level, and inability to distinguish wear from plastic creep or deformation under load. Strengths of this study include: large sample size of a single TKR system, linear regression of wear measurements and no requirement for implanted RSA beads with this method. Based on these results, in vivo volumetric wear of total knee replacement polyethylene can be reliably measured using model-based RSA and weight-bearing examinations in the short- to mid–term. Further work is needed to validate the accuracy of the measurements in vivo


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 11 - 11
1 Feb 2020
Ruhr M Polster V Morlock M
Full Access

INTRODUCTION. Precise determination of material loss is essential for failure analysis of retrieved hip cups. To determine wear, the measured geometry of the retrieval hast to be compared to its pristine geometry, which usually is not available. There are different approaches to generate reference geometries to approximate the pristine geometry that is commonly assumed as sphere. However, the geometry of press fit cup retrievals might not be spherical due to deformation caused by excessive press-fitting. The effect of three different reference geometries on the determined wear patterns and material loss of pristine and worn uncemented metal-on-metal hip cups was determined. METHODS. The surfaces of two cups (ASR, DePuy, Leeds; one pristine, one a worn retrieval) were digitized using a coordinate measurement machine (CRYSTA-Apex S574, Mitutoyo; 3 µm accuracy). Both cups were measured undeformed and while being deformed between a clamp. Three different methods for generating reference geometries were investigated (PolyWorks|Inspector 2018, InnovMetric). Method 1: A sphere with the nominal internal cup dimensions was generated. Method 2: A sphere was fitted to the measured data points after removing those from worn areas (deviation > 3 µm is defined as wear) to eliminate the influence of manufacturing tolerances on the nominal diameter. Method 3: Measurements, which displayed visual deformation in the computed wear pattern based on the best fit sphere, were fitted with an ellipsoid. The direction of the deformation axes and the amount of deformation were used to scale the best fit ellipsoid. Linear wear was calculated from the distance of the respective reference geometry to the measured point cloud. Finally, material loss is defined as the difference in volume of the reference geometry and the measured geometry. RESULTS. The method used for generating the reference geometry affected the determined wear greatly. Using the nominal manufacturing radius (larger than the best fit radius) for the worn cup falsely indicates deposit. This leads to approx. 39 % less wear volume compared to the best fit sphere analysis. Using an ellipsoid as reference geometry for both deformed cups improves the determination of the wear pattern and indicates areas of material loss better than a reference sphere. Additionally, the mistake in material loss determination is decreased, especially for the worn cup almost exactly to the wear volume analyzed with the best fit sphere before deformation. DISCUSSION. For correct determination of material loss best fit geometries instead of nominal sizes have to be used to compensate the differences due to manufacturing tolerances. Furthermore, deformation always has to be eliminated to generate correct wear patterns and volumes. Using an ellipsoid as reference geometry improves the outcome. For generating an even more accurate reference geometry, the exact behavior of the cup during deformation must be understood. Limitations to this method are cups that do not provide pristine areas in order to generate an appropriate best fit geometry. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 22 - 22
1 Feb 2020
Lawrence J Keggi J Randall A DeClaire J Ponder C Koenig J Shalhoub S Wakelin E Plaskos C
Full Access

Introduction. Soft-tissue balancing methods in TKA have evolved from surgeon feel to digital load-sensing tools. Such techniques allow surgeons to assess the soft-tissue envelope after bone cuts, however, these approaches are ‘after-the-fact’ and require soft-tissue release or bony re-cuts to achieve final balance. Recently, a robotic ligament tensioning device has been deployed which characterizes the soft tissue envelope through a continuous range-of-motion after just the initial tibial cut, allowing for virtual femoral resection planning to achieve a targeted gap profile throughout the range of flexion (figure-1). This study reports the first early clinical results and patient reported outcomes (PROMs) associated with this new technique and compares the outcomes with registry data. Methods. Since November 2017, 314 patients were prospectively enrolled and underwent robotic-assisted TKA using this surgical technique (mean age: 66.2 ±8.1; females: 173; BMI: 31.4±5.3). KOOS/WOMAC, UCLA, and HSS-Patient Satisfaction scores were collected pre- and post-operatively. Three, six, and twelve-month assessments were completed by 202, 141, and 63 patients, respectively, and compared to registry data from the Shared Ortech Aggregated Repository (SOAR). SOAR is a TJA PROM repository run by Ortech, an independent clinical data collection entity, and it includes data from thousands of TKAs from a diverse cross-section of participating hospitals, teaching institutions and clinics across the United States and Canada who collect outcomes data. PROMs were compared using a two-tailed t-test for non-equal variance. Results. When comparing the baseline PROM scores, robotic patients had equivalent womac knee stiffness (p=0.58) and UCLA activity scale (p=0.38) scores but slightly higher womac knee pain (p=0.002) and functional scores (p=0.014, figure-2). While all scores improved over time, the rate of improvement was generally greater at 6 months than at three months when comparing the two groups, with statistically higher six-month scores in the robotic group for all categories (p<0.001). Overall patient satisfaction in the RB cohort was 90.3%, 95.0% and 91.8% at 3M, 6M and 1Y, respectively (figure-3). Average length of hospital stay was 1.6 days (±0.8). Surgical complications in this cohort included one infection four months post-op, 6 post-operative knee manipulations, one pulmonary embolism and one wound dehiscence from a fall. Discussion. We postulated that the ability to use gap data prospectively under known loading conditions throughout the knee range-of-motion would allow femoral cut planning that resulted in optimum balance with fewer releases and better long-term results. While the study group patients had slightly higher baseline knee pain and function than registry patients and showed similar net improvements at the three-month mark, study patients showed significantly better improvements in all areas between three months and six months compared to registry data. WOMAC stiffness and UCLA activity scores were equal between the two groups at baseline and significantly improved at three months and six months. Better ligament balance may have significantly contributed to these gains and to the high rates of satisfaction reported in the study patients compared to the historical literature. Limitations to this study include the small number of patients and the lack of a closely matched control group. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 73 - 73
1 Feb 2020
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar M Turgeon T
Full Access

Purpose. The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery. Methods. Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution. Supine RSA radiographs were obtained post-operatively and at 6-, 12-, and 24-months. Standing (weight-bearing) RSA radiographs were obtained at 12-months (n=45) and 24-months (n=48). All patients received the same knee design with a fixed, conventional PE insert of either a cruciate retaining or posterior stabilized design. Ethics approval for this study was obtained. In order to assess in vivo wear, a highly accurate 3-dimensional virtual model of each in vivoTKA was developed. Coordinate data from RSA radiographs (mbRSA v3.41, RSACore) were applied to digital implant models to reconstruct each patient's replaced knee joint in a virtual environment (Geomagic Studio, 3D Systems). Wear was assessed volumetrically (digital model overlap) on medial and lateral condyles separately, across each follow-up. Annual rate of wear was calculated for each patient as the slope of the linear best fit between wear and time-point. The influence of weight-bearing was assessed as the difference in annual wear rate between standing and supine exams. Age, BMI, and Oxford-12 knee improvement were measured against wear rates to determine correlations. Results. Weight bearing wear measurement was most consistent and prevalent in the medial condyle with 0–4% of calculated wear rates being negative compared to 29–39% negative wear rates for the lateral condyle. For the medial condyle, standing exams revealed higher mean wear rates at 1 and 2 years; supine, 16.3 mm. 3. /yr (SD: 27.8) and 11.2 mm. 3. /yr (SD: 18.5) versus standing, 51.3 mm. 3. /yr (SD: 55.9) and 32.7 mm. 3. /yr (SD: 31.7). The addition of weight-bearing increased the measured volume of wear for 78% of patients at 1 year (Avg: 32.4 mm. 3. /yr) and 71% of patients at 2 years (Avg: 48.9 mm. 3. /yr). There were no significant (95% CI) correlations between patient demographics and wear rates. Discussion and Conclusion. This study demonstrated TKA wear to occur at a rate of approximately 10 mm. 3. /year and 39 mm. 3. /year in patients imaged supine versus standing, respectively, averaged over 2 years of clinical follow-up. In an effort to eliminate the effect of PE creep and deformation, wear was also calculated between 12 and 24 months as 9.3 mm. 3. (standing examinations), This value is comparable to wear rates obtained from retrieved TKRs. Weight-bearing exams produced better wear data with fewer negative wear rates and reduced variance. Limitations of this study include: supine patient imaging performed at post-op, no knee flexion performed, and unknown patient activity level. Strengths of this study include: large sample size of a single TKR system, linear regression of wear measurements and no requirement for implanted RSA beads with this method. Based on these results, in vivo volumetric wear of total knee replacement polyethylene can be reliably measured using model-based RSA and weight-bearing examinations in the short- to mid–term. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 102 - 102
1 Mar 2017
Xie T Zeng J
Full Access

Background. Percutaneous endoscopic interlaminar discectomy (PEID) has achieved favorable effects in the treatment of lumbar disc herniation (LDH), as a new surgical procedure. With its wide range of applications, a series of complications related to the operation has gradually emerged. Objective. To describe the type, incidence and characteristics of the complications following PEID and to explore preventative and treatment measures. Study Design. Retrospective, observational study. Setting. A spine center affiliated with a large general hospital. Method. In total, 479 cases of patients with LDH received PEID, which was performed by an experienced spine surgeon between January 2010 and April 2013. Data concerning the complications were recorded. Result. All of the 479 cases successfully received the procedure. A total of 482 procedures were completed. The mean follow-up time was 44.3 months, ranging from 24 to 60 months. The average patient age was 47.8 years, ranging from 16 to 76 years. There were 29 (6.0%) related complications that emerged, including 3 cases (0.6%) of fragment omission, and the symptoms gradually eased following 3–6 weeks of conservative treatment; 2 cases (0.4%) of nerve root injury, and the patients recovered well following 1–3 months of taking neurotrophic drugs and functional exercise; 15 cases (3.1%) of paresthesia, and this condition gradually improved following 3–6 weeks of rehabilitation exercises and treatment with mecobalamin and pregabalin; and recurrence occurred in 9 cases (1.9%), and the condition was controlled in 4 of these cases by using a conservative method, while 5 of the cases underwent reoperation, including 3 traditional open surgeries and 2 PEID. Furthermore, the complication rate for the first 100 cases was 16%. This rate decreased to 3.4% (for cases 101–479), and the incidence of L4–5 (8.2%) was significantly higher than L5-S1 (4.5%). Limitations. This is a retrospective study, and some bias exists due to the single-center study design. Conclusion. PEID is a surgical approach, which has a low complication rate. Fragment omission, nerve root injury, paresthesia and recurrence are relatively common. Some effective measures can prevent and reduce the incidence of the complications, such as strict indications for surgery, a thorough action plan and skilled operation skills