Advertisement for orthosearch.org.uk
Results 1 - 20 of 76
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 241 - 245
1 Mar 2019
Leaver T Johnson B Lampard J Aarvold A Uglow M

Aims. The aim of this study was to quantify the risk of developing cancer from the exposure to radiation associated with surgery to correct limb deformities in children. Patients and Methods. A total of 35 children were studied. There were 19 girls and 16 boys. Their mean age was 11.9 years (2 to 18) at the time of surgery. Details of the radiological examinations were recorded during gradual correction using a Taylor Spatial Frame. The dose area product for each radiograph was obtained from the Computerised Radiology Information System database. The effective dose in millisieverts (mSv) was calculated using conversion coefficients for the anatomical area. The lifetime risk of developing cancer was calculated using government-approved Health Protection Agency reports, accounting for the age and gender of the child. Results. Correction was undertaken in five femurs, 18 tibiae, and 12 feet. The median duration of treatment was 45 months (11 to 118). The mean effective dose was 0.31 mSv (0.05 to 0.64) for the femur, 0.29 mSv (0.01 to 0.97) for the tibia, and 0.027 mSv (0.001 to 0.161) for the foot. The cumulative exposure gave ‘negligible’ risk in 26 children and ‘minimal’ risk in nine children, according to Public Health England categories. These results are below the mean annual background radiation in the United Kingdom. Conclusion. The lifetime attributable risk of developing cancer from repeated exposure to radiation was negligible or minimal in all children. This is the first study to quantify the exposure to radiation from serial radiographs in children with limb deformities who are treated surgically using circular external fixation, linking this to the risk of developing cancer. Cite this article: Bone Joint J 2019;101-B:241–245


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 37 - 37
1 Apr 2022
McMahon S Hill R Pinto D Jackson D
Full Access

Introduction

We present the first 12 consecutive patients, undergoing elective paediatric limb reconstruction with an external fixator, for the 12-month period October 2020-October 2021. This is a single surgeon series for a newly appointed Consultant with limited previous experience. Arrangements were made for mentoring by a senior surgeon recently retired from the NHS but still active in private practice.

Materials and Methods

The average age of patients was 10.5years at the time of frame application (5—15 years). Four frames in three patients were for Blount's; two for sequelae of NF1; two for posteromedial tibial bow with shortening, two for fibula hemimelia; one congenital short femur, one for sequelae of neonatal sepsis and one for bone loss following tumour resection.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 24 - 24
23 Apr 2024
Thompson E James L Narayan B Peterson N
Full Access

Introduction. Management of deformity involving limb length discrepancy (LLD) using intramedullary devices offers significant benefits to both patients and clinicians over traditional external fixation. Following the withdrawal of the PRECICE nail, the Fitbone became the primary implant available for intramedullary lengthening and deformity correction within our service. This consecutive series illustrates the advantages and complications associated with the use of this device, and describes a novel technique modification for antegrade intramedullary lengthening nails. Materials & Methods. A retrospective cohort review was performed of patient outcomes after treatment with the Fitbone nail at two tertiary referral limb reconstruction services (one adult, one paediatric) between January 2021 to December 2023. Aetiology, indications, initial and final LLD, use of concomitant rail assisted deformity correction (ORDER), removal time and healing index were assessed. Complications of treatment were evaluated and described in detail, alongside technique modifications to reduce the rate of these complications. Results. 21 nails (18 femoral, 2 tibial, 1 humeral) were inserted in 6 adult and 13 paediatric patients. Post-traumatic and congenital/developmental LLD were the most common indications for surgery in the adult and paediatric cohorts respectively. ORDER was employed in 11 cases (9 femurs and 2 tibias). Treatment goals were achieved in all but one case. Complications included superficial infection, locking bolt migration, periprosthetic fracture and component failure. Seven patients required unplanned returns to theatre. Conclusions. The Fitbone nail is an established option for intramedullary limb lengthening, however its use in the UK has been relatively limited compared to the PRECICE until 2021. Our data helps to define its place for limb lengthening and complex deformity correction in both adult and paediatric patients, including in humeral lengthening and retrograde femoral insertion across an open physis. We have identified important potential risks and novel techniques to simplify surgery and avoid complications


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 4 | Pages 745 - 747
1 Nov 1963
Blockey NJ Lawrie JH

We describe two siblings with congenital growth defects of the distal limb bones and their progress over four years. They bear some resemblances to a boy described in 1958 by Solonen and Sulamaa and to a father and his three sons described in 1944 by Nievergelt.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 25 - 25
23 Apr 2024
Aithie J Oag E Butcher R Messner J
Full Access

Introduction. Genu valgum is a common presentation in paediatric patients with congenital limb deformities. The aim of this study is to assess the outcome of guided growth surgery in paediatric patients referred via our physiotherapy pathway with isolated genu valgum and associated patellar instability. Materials & Methods. Patients were identified from our prospective patellar instability database. Inclusion criteria was acquired or congenital genu valgum associated with patellar instability in skeletally immature patients. The mechanical lateral-distal femoral angle was assessed on long leg alignment radiographs (mLDFA <85 degrees). Surgical treatment was the placement of a guided growth plate (PediPlate, OrthoPediatrics, USA) on the medial distal femoral physis (hemi-epiphysiodesis). KOOS-child scores were collected pre-operatively and post-operatively (minimum at 6 months). Results. Eleven patients (seven female) with mean age of 12(range 5–15) were identified. Five patients had congenital talipes equinovarus(CTEV), one fibular hemimelia, one di-George syndrome, one septic growth arrest and three had idiopathic genu valgum. Pre- and post-operative KOOS-child scores showed overall improvement: 58(range 36–68) to 88(65–99) and knee symptoms subscores: 64(43–71) to 96(68–100) p<0.01, t-test. Mean follow-up was 10 months (range 3–23). No subsequent dislocations/subluxations occurred during follow-up. Conclusions. Guided growth surgery is an effective way of treating symptomatic patellar instability in skeletally immature patients with genu valgum in the absence of other structural pathology. It was most common in our cohort in patients with unilateral CTEV. We would recommend to screen syndromic and congenital limb deformity patients for patellar instability symptoms in the presence of genu valgum


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 24 - 24
1 Dec 2022
Trisolino G Frizziero L Santi GM Alessandri G Liverani A Menozzi GC Depaoli A Martinelli D Di Gennaro GL Vivarelli L Dallari D
Full Access

Paediatric musculoskeletal (MSK) disorders often produce severe limb deformities, that may require surgical correction. This may be challenging, especially in case of multiplanar, multifocal and/or multilevel deformities. The increasing implementation of novel technologies, such as virtual surgical planning (VSP), computer aided surgical simulation (CASS) and 3D-printing is rapidly gaining traction for a range of surgical applications in paediatric orthopaedics, allowing for extreme personalization and accuracy of the correction, by also reducing operative times and complications. However, prompt availability and accessible costs of this technology remain a concern. Here, we report our experience using an in-hospital low-cost desk workstation for VSP and rapid prototyping in the field of paediatric orthopaedic surgery. From April 2018 to September 2022 20 children presenting with congenital or post-traumatic deformities of the limbs requiring corrective osteotomies were included in the study. A conversion procedure was applied to transform the CT scan into a 3D model. The surgery was planned using the 3D generated model. The simulation consisted of a virtual process of correction of the alignment, rotation, lengthening of the bones and choosing the level, shape and direction of the osteotomies. We also simulated and calculated the size and position of hardware and customized massive allografts that were shaped in clean room at the hospital bone bank. Sterilizable 3D models and PSI were printed in high-temperature poly-lactic acid (HTPLA), using a low-cost 3D-printer. Twenty-three operations in twenty patients were performed by using VSP and CASS. The sites of correction were: leg (9 cases) hip (5 cases) elbow/forearm (5 cases) foot (5 cases) The 3D printed sterilizable models were used in 21 cases while HTPLA-PSI were used in five cases. customized massive bone allografts were implanted in 4 cases. No complications related to the use of 3D printed models or cutting guides within the surgical field were observed. Post-operative good or excellent radiographic correction was achieved in 21 cases. In conclusion, the application of VSP, CASS and 3D-printing technology can improve the surgical correction of complex limb deformities in children, helping the surgeon to identify the correct landmarks for the osteotomy, to achieve the desired degree of correction, accurately modelling and positioning hardware and bone grafts when required. The implementation of in-hospital low-cost desk workstations for VSP, CASS and 3D-Printing is an effective and cost-advantageous solution for facilitating the use of these technologies in daily clinical and surgical practice


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 26 - 26
23 Apr 2024
Aithie J Herman J Holt K Gaston M Messner J
Full Access

Introduction. Limb deformity is usually assessed clinically assisted by long leg alignment radiographs and further imaging modalities (MRI and CT). Often decisions are made based on static imaging and simple gait interpretation in clinic. We have assessed the value of gait lab analysis in surgical decision making comparing surgical planning pre and post gait lab assessment. Materials & Methods. Patients were identified from the local limb reconstruction database. Patients were reviewed in the outpatient clinic and long leg alignment radiographs and a CT rotational limb profile were performed. A surgical plan was formulated and documented. All patients then underwent a formal gait lab analysis. The gait lab recommendations were then compared to the initial plan. Results. Twelve patients (8 female) with mean age of 14 (range 12–16) were identified. Nine were developmental torsional malalignments, one arthrogryposis, one hemiparesis secondary to spinal tumour resection and one syndromic limb deficiency. The gait lab recommended conservative management in four patients and agreed with eight surgical plans with one osteotomy level changing. Five patients are post-operative: two bilateral distal tibial osteotomies, two de-rotational femoral osteotomy with de-rotational tibial osteotomies and one bilateral femoral de-rotational osteotomies. Conclusions. Limb deformity correction is major surgery with long rehabilitation and recovery period. Gait lab analysis can identify who would benefit from conservative management rather than surgery with our study showing changes to surgical planning in one third of patients. The gait lab analysis helps to identify patients with functional and neuromuscular imbalances where correcting the bony anatomy may not actually benefit the patient


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 6 - 6
1 Apr 2022
Moore D Noonan M Kelly P Moore D
Full Access

Introduction. Angular deformity in the lower extremities can result in pain, gait disturbance, deformity and joint degeneration. Guided growth modulation uses the tension band principle with the goal of treatment being to normalise the mechanical axis. To assess the success of this procedure we reviewed our results in an attempt to identify patients who may not benefit from this simple and elegant procedure. Materials and Methods. We reviewed the surgical records and imaging in our tertiary children's hospital to identify all patients who had guided growth surgery since 2007. We noted the patient demographics, diagnosis, peri-operative experience and outcome. All patients were followed until skeletal maturity or until metalwork was removed. Results. 173 patients with 192 legs were assessed for eligibility. Six were excluded due to inadequate follow-up or loss of records. Of the 186 treated legs meeting criteria for final assessment 19.8% were unsuccessful, the other 80.2% were deemed successful at final follow up. Complications included infection and metal-work failure. Those with a pre-treatment diagnosis of idiopathic genu valgum/ varum had a success rate of 83.6%. Conclusions. In our hands, guided growth had an 80-percent success rate when all diagnosis were considered. Those procedures that were unlikely to be successful included growth disturbances due to mucopolysaccharide storage disease, Blounts disease and achondroplasia. Excluding those three diagnoses, success rate was 85.4%. We continue to advocate the use of guided growth as a successful treatment option for skeletally immature patients with limb deformity


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 128 - 128
1 Nov 2021
Stallone S Trisolino G Zarantonello P Ferrari D Papaleo P Napolitano F Santi GM Frizziero L Liverani A Gennaro GLD
Full Access

Introduction and Objective. Virtual Surgical Planning (VSP) is becoming an increasingly important means of improving skills acquisition, optimizing clinical outcomes, and promoting patient safety in orthopedics and traumatology. Pediatric Orthopedics (PO) often deals with the surgical treatment of congenital or acquired limbs and spine deformities during infancy. The objective is to restore function, improve aesthetics, and ensure proper residual growth of limbs and spine, using osteotomies, bone grafts, age-specific or custom-made hardware and implants. Materials and Methods. Three-dimensional (3D) digital models were generated from Computed Tomography (CT) scans, using free open-source software, and the surgery was planned and simulated starting from the 3D digital model. 3D printed sterilizable models were fabricated using a low-cost 3D printer, and animations of the operation were generated with the aim to accurately explain the operation to parents. All procedures were successfully planned using our VSP method and the 3D printed models were used during the operation, improving the understanding of the severely abnormal bony anatomy. Results. The surgery was precisely reproduced according to VSP and the deformities were successfully corrected in eight cases (3 genu varum in Blount disease, 2 coxa vara in pseudo achondroplasia, 1 SCFE, 1 missed Monteggia lesion and 1 post-traumatic forearm malunion deformity). In one case, a focal fibrocartilaginous dysplasia, the intraoperative intentional undersizing of the bone osteotomy produced an incomplete correction of a congenital forearm deformity. Conclusions. Our study describes the application of a safe, effective, user-friendly, VSP process in PO surgery. We are convinced that our study will stimulate the widespread adoption of this technological innovation in routine clinical practice for the treatment of rare congenital and post-traumatic limb deformities during childhood


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 63 - 63
1 Nov 2021
Visscher L White J Tetsworth K McCarthy C
Full Access

Introduction and Objective. Malunion after trauma can lead to coronal plane malalignment in the lower limb. The mechanical hypothesis suggests that this alters the load distribution in the knee joint and that that this increased load may predispose to compartmental arthritis. This is generally accepted in the orthopaedic community and serves as the basis guiding deformity correction after malunion as well as congenital or insidious onset malalignment. Much of the literature surrounding the contribution of lower limb alignment to arthritis comes from cohort studies of incident osteoarthritis. There has been a causation dilemma perpetuated in a number of studies - suggesting malalignment does not contribute to, but is instead a consequence of, compartmental arthritis. In this investigation the relationship between compartmental (medial or lateral) arthritis and coronal plane malalignment (varus or valgus) in patients with post traumatic unilateral limb deformity was examined. This represents a specific niche cohort of patients in which worsened compartmental knee arthritis after extra-articular injury must rationally be attributed to malalignment. Materials and Methods. The picture archiving system was searched to identify all 1160 long leg x ray films available at a major metropolitan trauma center over a 12-year period. Images were screened for inclusion and exclusion criteria, namely patients >10 years after traumatic long bone fracture without contralateral injury or arthroplasty to give 39 cases. Alignment was measured according to established surgical standards on long leg films by 3 independent reviewers, and arthritis scores Osteoarthritis Research Society International (OARSI) and Kellegren-Lawrence (KL) were recorded independently for each compartment of both knees. Malalignment was defined conservatively as mechanical axis deviation outside of 0–20 mm medial from centre of the knee, to give 27 patients. Comparison of mean compartmental arthritis score was performed for patients with varus and valgus malalignment, using Analysis of Variance and linear regression. Results. In knees with varus malalignment there was a greater mean arthritis score in the medial compartment compared to the contralateral knee, with OARSI scores 5.69 vs 3.86 (0.32, 3.35 95% CI; p<0.05) and KL 2.92 vs 1.92 (0.38, 1.62; p<0.005). There was a similar trend in valgus knees for the lateral compartment OARSI 2.98 vs 1.84 (CI −0.16, 2.42; p=0.1) and KL 1.76 vs 1.31 (CI −0.12, 1.01; p=0.17), but the evidence was not conclusive. OARSI arthritis score was significantly associated with absolute MAD (0.7/10mm MAD, p<0.0005) and Time (0.6/decade, p=0.01) in a linear regression model. Conclusions. Malalignment in the coronal plane is correlated with worsened arthritis scores in the medial compartment for varus deformity and may similarly result in worsened lateral compartment arthritis in valgus knees. These findings support the mechanical hypothesis that arthritis may be related to altered stress distribution at the knee, larger studies may provide further conclusive evidence


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 96 - 96
1 Mar 2021
Abood A Rahbek O Moeller-Madsen B Kold S
Full Access

The use of retrograde femoral intramedullary nails in children for deformity correction is controversial. It is unknown if the injury to the central part of the growth plate results in premature bony union, leading to limb deformities or discrepancies. The aim of this study was to assess physeal healing and bone growth after insertion of a retrograde femoral nail thorough the centre of the physis in a skeletally immature experimental porcine model. Eleven immature pigs were included in the study. One leg was randomised for operation with a retrograde femoral nail (diameter 10.7 mm), whilst the non-operated contralateral remained as control. All nails were inserted centrally in coronal and sagittal plane under fluoroscopic guidance, and the nails spanned the physis. The nails were removed at 8 weeks. Both femora in all animals underwent MRI at baseline (pre-operatively), 8 weeks (after nail removal) and 16 weeks (before euthanasia). Femoral bone length was measured at 5 sites (anterior, posterior, central, lateral and medial) using 3d T1-weighted MRI. Growth was calculated after 8 weeks (growth with nail) and 16 weeks (growth without nail). Physeal cross-sectional area and percentage violated by the nail was determined on MRI. Operated side was compared to non-operated. Corresponding 95% confidence intervals were calculated. No differences in axial growth were observed between operated and non-operated sides. Mean growth difference was 0,61 mm [−0,78;2,01] whilst the nail was inserted into the bone and 0,72 mm [−1,04;1,65] after nail removal. No signs of angular bone deformities were found when comparing operated side to non-operated side. No premature bony healing at the physis occurred. Histology confirmed fibrous healing. Mean physeal violation was 5.72% [5.51; 5.93] by the femoral nail. The insertion of a retrograde femoral nail through the centre of an open physis might be a safe procedure with no subsequent growth arrest. However, experiments assessing the long term physeal healing and growth are needed


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 10 - 10
1 Dec 2017
Hotchen AJ Garcia-Pulido P Gojanur A Stohr K
Full Access

Aims. This case series aims to describe the clinical consequences of juxta-physeal sub-acute osteomyelitis in children, specifically growth and limb deformity. Methods. All children diagnosed with osteomyelitis between 2014 and 2016 at a single University Teaching Hospital in the UK were included. Juxta-physeal sub-acute osteomyelitis was identified using magnetic resonance imaging obtained within 48-hours of presentation. These cases were followed up prospectively on a regular basis in the outpatient clinic. Any clinical evidence of limb or growth deformity was evaluated using long-leg standing radiographs. Results. During the study period, 63 paediatric osteomyelitis cases were identified and four of these (6%) had juxta-physeal sub-acute osteomyelitis. All bone infections were located either in the distal femur or proximal tibia. All cases were treated with six weeks of intravenous ceftriaxone and three children underwent surgical procedures. All four cases developed a growth deformity in the affected limb. Conclusions. A variety of growth disturbances can occur following sub-acute osteomyelitis which could be secondary to physeal stimulation and overgrowth. In this series, overgrowth occurred in the physis immediately adjacent to the Brodie's abscess. Subsequently, the presence of a medial abscess caused a valgus deformity and a lateral abscess caused a varus deformity. This phenomenon has not been well-described in the literature. The tibial and femoral physes are amongst the most active in the body, which may explain the reason for the observed overgrowth deformity in these cases. The age of the patient and the method of treatment did not appear to influence the emergence of the growth deformity. None of our patients had recurrence or development of chronic osteomyelitis within the measured time period. In view of these findings, we recommend regular follow-up including assessment for limb deformity for a minimum of 3-years following the treatment of sub-acute osteomyelitis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 82 - 82
1 Aug 2020
Addar A Hamdy RC Fassier F Jiang F Marwan Y Algarni N Montpetit K
Full Access

The use of intramedullary implants in Osteogenesis Imperfecta (OI) patients to treat and prevent fractures, non-unions and limb deformities has been well established. To serve this purpose different implants are available from non-telescoping rods such as Rush rods and Kirschner wires, to telescoping rods such as the Dubow-Bailey rod, the Sheffield rod and the Fassier-Duval (FD) rod (Pega Medical, Laval, Quebec, Canada). The purpose of this study is to report on the long-term results of the femoral Fassier-Duval rod. A retrospective chart review of all patients with OI who underwent a femoral intramedullary Fassier-Duval rodding between 2002 and 2017 and followed for an average of 12 years at the Shriner's Hospital, Montreal, Quebec, Canada was performed. A total of 81 patients underwent femoral FD rodding between 2002 and 2017. Twenty-seven children undergoing 83 procedures had completed a minimum 10-year follow up with complete charts and these were included here. The average follow up time was 12 years (10–15 years). Fifty procedures were initial rodding surgeries and 30 (36.1%) were revision surgeries. A total of 69 complications were reported in the medical record and confirmed on x-ray. The 3 most common complications were a bent rod 24 (34.8%), femur fracture 16 (23.2%) and loss of telescoping in 12 (17.4%) of patients. The 3 most common cause of revision were femur fracture 16 (53.3%), broken rod 5 (16.7%) and coxa vara in 3 (10%) of patients. The average time from initial surgery to the first revision was 5.9 years. Long term performance of femoral FD rodding shows that despite improved functioning with these rods, certain complications are to be expected, most commonly a risk of femoral fracture requiring revision surgery


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 57 - 57
1 May 2016
Bruni D Iacono F Bignozzi S Marcacci M
Full Access

The main purpose of the present study is to prospectively investigate whether preoperative functional flexion axis in patients with osteoarthritisand varus-alignment changes after total knee arthroplasty and whether a correlation exists both between preoperative functional flexion axis and native limb deformity. A navigated total knee arthroplasty was performed in 108 patients using a specific software to acquire passive joint kinematics before and after implant positioning. The knee was cycled through three passive range of motions, from 0 to 120. Functional flexion axis was computed using the mean helical axis algorithm. The angle between the functional flexion axis and the surgical transepicondylar axis was determined on frontal (aF) and axial (aA) plane. The pre- and postoperative hip-kneeankle angle, related to femur mechanical axis, was determined. Postoperative functional flexion axis was different from preoperative only on frontal plane, while no differences were found on axial plane. No correlation was found between preoperative aA and native limb deformity, while a poor correlation was found in frontal plane, between aF and preoperative hip-knee-ankle angle. Total knee arthroplasty affects functional flexion axis only on frontal plane while has no effect on axial plane. Preoperative functional flexion axis is in a more varus position respect to the transepicondylar axis both in pre- and postoperative conditions. Moreover, the position of the functional axis on frontal plane in preoperative conditions is dependent on native limb alignment, while on axial plane is not dependent on the amount of preoperative varus deformity


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 58 - 58
1 Oct 2019
Mullaji AB Panjwani T
Full Access

Aims. The aims of this prospective study were to determine the effect of osteophyte excision on deformity correction and soft-tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA). Patients and Methods. Four-hundred twenty-five consecutive, cemented, cruciate-substituting TKAs were analysed. Pre-operative varus was calculated on long leg weight-bearing HKA film. Limb deformity in coronal (varus) and sagittal (flexion) planes, medial and lateral gap distances in maximum knee extension and 90° knee flexion and maximum knee flexion were recorded before and after excision of medial femoral and tibial osteophytes using computer navigation. Data was extracted and analysed to assess the effect of removal of osteophytes on the correction of deformity and soft tissue balance. Results. Before removal of any osteophytes or soft tissue releases, 138 out of 425 (32%) achieved correction of deformity (HKA 180+2°). In the remaining knees, after osteophyte removal 183 knees (43%) achieved correction of deformity. Overall, 75% knees achieved deformity correction after removal of osteophytes. For the remaining 25% knees, additional procedures (such as capsular release, semimembranosus release, reduction osteotomy) were needed for deformity correction. Conclusion. Three-fourths of all knees were aligned with no release or only removal of osteophytes. Excision of medial femoral and tibial osteophytes can be a useful, initial step towards achieving deformity correction and gap balance without having to resort to soft-tissue release during TKA in varus knees. This is useful information for surgeons to desist from any soft tissue releases till osteophytes have been meticulously excised. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 82 - 82
1 Apr 2019
Mullaji A Shetty G
Full Access

Aims. The aims of this prospective study were to determine the effect of osteophyte excision on deformity correction and soft- tissue gap balance in varus knees undergoing total knee arthroplasty (TKA). Patients and Methods. Limb deformity in coronal (varus) and sagittal (flexion) planes, medial and lateral gap distances in maximum knee extension and 90° knee flexion and maximum knee flexion were recorded before and after excision of medial femoral and tibial osteophytes using computer navigation in 164 patients who underwent 221 computer-assisted, cemented, cruciate- substituting TKAs. Results. Mean varus and flexion deformities of 4.5°±3° (0.5° to 30° varus) and 4.9°±5.9° (−15° hyperextension to 30° flexion) reduced significantly (p<0.0001) to mean varus deformity of 1°±2.3° and mean flexion deformity of 2.7°±4.2° after excision of medial femoral and tibial osteophytes. The mean medio-lateral (ML) soft-tissue gap difference in maximum knee extension and 90°knee flexion of 2.7±3.6mm and 0.7±2.6mm reduced significantly (p<0.0001) to mean ML soft-tissue gap difference of 0.7±2.5mm in maximum knee extension and 0.1±1.9mm in 90°knee flexion. The mean maximum knee flexion (122.8°±8.4°) increased significantly to mean maximum knee flexion of (125°±8°). Conclusion. Excision of medial femoral and tibial osteophytes during TKA in varus knees significantly improves varus and flexion deformities, mediolateral soft-tissue gap imbalance in maximum extension and in 90°knee flexion and maximum knee flexion. Clinical Relevance. Excision of medial femoral and tibial osteophytes can be a useful, initial step towards achieving deformity correction and gap balance without having to resort to soft-tissue release during TKA in varus knees


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 7 - 7
1 Jan 2011
Gilbody J Ho K Kundra R Wellings R Gaffey A
Full Access

Modern methods of deformity correction such as the Taylor Spatial Frame (TSF) allow correction of deformities to within tolerances of 1° and 0.5mm. Plain X-radiography using orthogonal views is the current standard for the assessment for the evaluation of angular limb deformities. CT has been used for the assessment of torsional and axial deformities but its use has not been described for the measurement of angular deformities. Furthermore, dedicated correction planning software (SpatialCad™) may allow more accurate deformity definition. This study aims to evaluate the accuracy of CT and SpatialCad™ to measure angular deformities in vitro. A tibia sawbone was coated in radio-opaque paint. A TSF was mounted on it and an osteotomy made in the mid-diaphyseal region. Four deformities were created and imaged with plain radiography and CT. Four observers measured the deformities using paper and pencil, PACS and SpatialCad™ for plain radiographs and Spatial-Cad™ for the CT scout views. The variance of the mean response of observed differences between main treatment factors was measured using analysis of variance. There was no significant difference in variability (precision) between observers or methods of measurement. However, measurements made with PACS and Spatial-Cad™ on plain radiographs, but not CT scout views, were also accurate. There does not appear to be any evidence at present that the use of CT for measurement of angular limb deformity is justified over plain radiography. Spatial-Cad™ is designed to optimize deformity correction planning for use with TSF, but PACS appears to be adequate for use with other deformity correction systems


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 59 - 66
1 Jun 2021
Abhari S Hsing TM Malkani MM Smith AF Smith LS Mont MA Malkani AL

Aims. Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment. Methods. A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019. Results. Mean overall patient satisfaction for the entire cohort was 4.7 (SE 0.1) on a 5-point Likert scale, with 93% being either very satisfied or satisfied compared with a Likert of 4.3 and patient satisfaction of 81% in the mechanical alignment group (p < 0.001 and p < 0.006 respectively). At mean follow-up of 17 months (11 to 27), the mean overall Likert, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Western Ontario and McMaster Universities Osteoarthritis Index, Forgotten Joint Score, and Knee Society Knee and Function Scores were significantly better in the kinematic group than in the neutral mechanical alignment group. The most common complication in both groups was contracture requiring manipulation under anaesthesia, involving seven knees (6.1%) in the kinematic group and nine knees (7.8%) in the mechanical alignment group. Conclusion. With the advent of advanced technology, and the ability to obtain accurate bone cuts, the target limb alignment, and soft-tissue balance within millimetres, using a restricted kinematic alignment concept demonstrated excellent patient satisfaction following primary TKA. Longer-term analysis is required as to the durability of this method. Cite this article: Bone Joint J 2021;103-B(6 Supple A):59–66


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims. This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect. Patients and Methods. A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively. Results. The mean time to follow-up was 55 months (12 to 126). Overall, 16 (94%) of the patients achieved radiological filling of their bony defect and united to the native bone ends proximally and distally, resulting in a functioning limb. Complications included device failure in two patients (12%), infection in two (12%), and wound dehiscence in one (6%). Four patients (24%) required secondary surgery, four (24%) had a residual limb-length discrepancy, and one (6%) had a residual angular limb deformity. Conclusion. A titanium mesh cage is a useful adjunct in the treatment of an extra-articular segmental defect in a long bone. Cite this article: Bone Joint J 2018;100-B:646–51