Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 68 - 74
1 Jan 2012
Christel PS Akgun U Yasar T Karahan M Demirel B

The clinical diagnosis of a partial tear of the anterior cruciate ligament (ACL) is still subject to debate. Little is known about the contribution of each ACL bundle during the Lachman test. We investigated this using six fresh-frozen cadaveric lower limbs. Screws were placed in the femora and tibiae as fixed landmarks for digitisation of the bone positions. The femur was secured horizontally in a clamp. A metal hook was screwed to the tibial tubercle and used to apply a load of 150 N directed anteroposteriorly to the tibia to simulate the Lachman test. The knees then received constant axial compression and 3D knee kinematic data were collected by digitising the screw head positions in 30° flexion under each test condition. Measurements of tibial translation and rotation were made, first with the ACL intact, then after sequential cutting of the ACL bundles, and finally after complete division of the ACL. Two-way analysis of variance analysis was performed.

During the Lachman test, in all knees and in all test conditions, lateral tibial translation exceeded that on the medial side. With an intact ACL, both anterior and lateral tibial landmarks translated significantly more than those on the medial side (p < 0.001). With sequential division of the ACL bundles, selective cutting of the posterolateral bundle (PLB) did not increase translation of any landmark compared with when the ACL remained intact. Cutting the anteromedial bundle (AMB) resulted in an increased anterior translation of all landmarks. Compared to the intact ACL, when the ACL was fully transected a significant increase in anterior translation of all landmarks occurred (p < 0.001). However, anterior tibial translation was almost identical after AMB or complete ACL division.

We found that the AMB confers its most significant contribution to tibial translation during the Lachman test, whereas the PLB has a negligible effect on anterior translation. Section of the PLB had a greater effect on increasing the internal rotation of the tibia than the AMB. However, its contribution of a mean of 2.8° amplitude remains low. The clinical relevance of our investigation suggests that, based on anterior tibial translation only, one cannot distinguish between a full ACL and an isolated AMB tear. Isolated PLB tears cannot be detected solely by the Lachman test, as this bundle probably contributes more resistance to the pivot shift.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 88 - 88
7 Nov 2023
Greenwood K Molepo M Mogale N Keough N Hohmann E
Full Access

Knee arthroscopy is typically approached from the anterior, posteromedial and posterolateral portals. Access to the posterior compartments through these portals can cause iatrogenic cartilage damage and create difficulties in viewing the structures of the posterior compartments. The purpose of this study was to assess the feasibility of needle arthroscopy using direct posterior portals as both working and visualising portals. For workability, the needle scope was inserted advanced from anterior between the cruciate ligament bundle and the lateral wall of the medial femoral condyle until the posterior compartments were visualised. For visualisation, direct postero-lateral and -medial portals were established. The technique was performed in 9 knees by two experienced researchers. Workability and instrumentation of the posteromedial compartment and meniscus was achieved in 56%. The posterior horns could not be visualised in four specimens as the straight lens could not provide a more medial field of view. Visualisation from the direct medial posterior portal allowed a clear view of the medial meniscus, femoral condyle and posterior cruciate ligament in all specimens. Workability and instrumentation of the posterolateral compartment was not possible with the needle scope. Direct posterior approaches for the posteromedial compartment access are challenging with the current needle scope options and could only be achieved in over 50%. The postero-lateral compartment was not accessible. An angled lens or a flexible Needle scope would be better suited for developing this technique further


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 41 - 41
1 Dec 2017
Giles JW Chen Y Bowyer S
Full Access

Joint assessment through manual physical examination is a fundamental skill that must be acquired by orthopaedic surgeons. These joint assessments allow surgeons to identify soft tissue injuries (e.g. ligament tears) which are critical in identifying appropriate treatment options. The difficulty in communicating the feeling of different joint conditions and the limited opportunities for practice can make these skills challenging to learn, resulting in reduced treatment effectiveness and increased costs. This research seeks to improve the training of joint assessment with the creation of a haptic joint simulator that can train surgeons with increased effectiveness. A first of its kind haptic simulator is presented, which incorporates: a newly defined kinetic knee simulation, a haptic device for user interaction, and a haptic control algorithm. The knee model has been specifically created for this application and allows six degree-of-freedom manipulation of the tibia while considering the effects of ten knee ligament bundles. The model has been mathematically formulated to allow for the high update rates necessary for smooth and stable haptic simulation. Two quantitative assessments were made of the model to confirm its clinical validity. The first was against the widely used OpenSim biomechanical simulation software. Simulations of the model's performance for both anterior-posterior draw tests and varus-valgus rotation tests showed less than 0.7%RMSE for force and 5.5%RMSE for moments. Crucially, the proposed model could generate updated forces in less than 1ms, compared to 188ms for OpenSim. The second validation of the model was against a cadaveric knee that was tested using a validated robotic testing platform. This comparison showed that the model could generate similar force- motion pathways to the cadaveric knee after the model's parameters were scaled to match. Having demonstrated that it is possible to create a computational knee model that has good conformance to gold-standard knee simulations and cadaveric recordings, while updating at less than 1ms, this research has overcome a major hurdle. The next stage of this research will be to incorporate the knee model into a full haptic simulator and perform skill acquisition trials. Given the effectiveness of past haptic training systems in aiding clinical skills acquisition, this research offers a promising way to improve surgeon training, and therefore also patient diagnosis and treatment


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 99 - 99
1 Mar 2017
Willing R Walker P
Full Access

Introduction. The intrinsic constraint of a total knee replacement (TKR) implant system is considered an important characteristic which plays a large role in determining stability following surgery. Established techniques for evaluating the constraint of TKR implants, as described in ASTM F 1223-14, do not necessarily map directly to physiologically relevant loading scenarios where instability can occur, and thus give an incomplete picture of the constraint characteristics of a candidate implant design. Sophisticated joint motion simulators now allow for more physiologically representative joint loading (eg. gait), including the contributions of virtual soft tissues. In this study, we employ a function-based constraint measurement technique for evaluating the kinematics of two TKR designs during gait. Furthermore, we employ simulated soft tissues in order to create three “virtual” knees on which the TKR are tested. Methods. The constraint characteristics of TKR implants were evaluated using a function-based measurement technique on a VIVO joint motion simulator (AMTI, Waltham, MA). The AVG75 standardized load and motion profiles for gait (Bergmann et al. 2014), were applied to an ultra-congruent cruciate-sacrificing TKR (Zimmer-Biomet, Warsaw, IN). Ligaments were simulated as point-to-point spring elements between the femur and tibia (3 bundles for MCL, 3 bundles for LCL). Ligament bundle origin, insertion, stiffness, and resting length properties were adapted from the publically available MB Knee project (. simtk.org/home/mb_knee. ) to create three knees. AP and IE kinematics were recorded during simulated gait after approximately 500 “learning” cycles at 0.75 Hz. Trials were then repeated with superimposed AP forces or IE torques. The amount of superimposed load varied with the amount of compressive load, such that the superimposed load was ±25 N AP force or ±1 Nm IE torque, per 1000 N of compressive force. AP and IE laxities were calculated based on changes in AP and IE motions, respectively (Fig 1). Experiments were repeated with a second TKR design; using the same femoral component but replacing the ultra-congruent UHMWPE bearing with a 3D printed ABS plastic bearing featuring a less congruent sagittal profile. In total, there were 2 implants × 3 virtual knees × 5 simulated loading profiles = 30 different simulated gait trials. Results. The baseline (normal gait) AP and IE motions for both TKR designs, averaged across three knees, are shown in Fig. 2. The average AP and IE laxities for each knee are shown in Table 1, with results averaged for each TKR design. Discussion. Differences in AP motion between the two TKR designs are large compared to the differences in IE motion. Predictably, the overall AP and IE motions and average laxities for the less congruent TKR are greater. While this trend was generally consistent across all knees, the actual differences in laxities between the two TKR designs varied between knees. This suggests that the importance of the intrinsic constraint of TKR varies on subject-to-subject basis, and thus variable soft tissue stabilization models should be considered during pre-clinical testing. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 19 - 19
1 May 2016
Halloran J Zadzilka J Colbrunn R Bonner T Anderson C Klika A Barsoum W
Full Access

Introduction. Improper soft-tissue balancing can result in postoperative complications after total knee arthroplasty (TKA) and may lead to early revision. A single-use tibial insert trial with embedded sensor technology (VERASENSE from OrthoSensor Inc., Dania Beach, FL) was designed to provide feedback to the surgeon intraoperatively, with the goal to achieve a “well-balanced” knee throughout the range of motion (Roche et al. 2014). The purpose of this study was to quantify the effects of common soft-tissue releases as they related to sensor measured joint reactions and kinematics. Methods. Robotic testing was performed using four fresh-frozen cadaveric knee specimens implanted with appropriately sized instrumented trial implants (geometry based on a currently available TKA system). Sensor outputs included the locations and magnitudes of medial and lateral reaction forces. As a measure of tibiofemoral joint kinematics, medial and lateral reaction locations were resolved to femoral anterior-posterior displacement and internal-external tibial rotation (Fig 1.). Laxity style joint loading included discrete applications of ± 100 N A-P, ± 3 N/m I-E and ± 5 N/m varus-valgus (V-V) loads, each applied at 10, 45, and 90° of flexion. All tests included 20 N of compressive force. Laxity tests were performed before and after a specified series of soft-tissue releases, which included complete transection of the posterior cruciate ligament (PCL), superficial medial collateral ligament (sMCL), and the popliteus ligament (Table 1). Sensor outputs were recorded for each quasi-static test. Statistical results were quantified using regression formulas that related sensor outputs (reaction loads and kinematics) as a function of tissue release across all loading conditions. Significance was set for p-values ≤ 0.05. Results. Tissue releases, and in particular the sMCL and PCL, led to multiple findings, many of which were dependent on flexion (Table 2). For PCL resection, at 10° of flexion lateral and total joint loads decreased, whereas at 45 and 90° lateral load increased. In addition, there was a significant anterior shift of the femur that increased with flexion angle, while tibial rotation was only affected at 90°. sMCL release decreased the total load across all flexion angles, and impacted the medial load at 10° only. The only structure for which no significant relationship was discovered was the deep medial collateral ligament, as this variable was confounded on others. Discussion. One critical aspect of TKA is achieving appropriate soft-tissue balance to maximize postoperative performance. In this study, the sensor provided a direct measurement of joint loading and kinematics, which were related to surgically relevant soft-tissue releases. Results showed the sMCL to decrease joint loads and flexion dependent changes after PCL release, likely an indication of bundle specific response. Future work should be performed to examine the roles of individual ligament bundles, as well as graded effects of tissue releases. Overall, the results corroborate previous findings and provide a new and direct look at the role of ligaments in TKA. Significance. This study quantified relationships between surgically relevant tissue states and joint response in TKA. The data has the potential to be applied intraoperatively to guide soft-tissue releases. To view tables/figures, please contact authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 18 - 18
1 May 2016
Halloran J Colbrunn R Anderson C
Full Access

INTRODUCTION. Understanding the relationship between knee specific tissue behavior and joint contact mechanics remains an area of focus. Seminal work from 1990's established the possibility to optimize tissue properties for recreation of laxity driven kinematics (Mommersteeg et al., 1996). Yet, the uniqueness and validity of such predictions could be strengthened, especially as they relate to joint contact conditions. Understanding this interplay has implications for the long term performance of joint replacements. Development of instrumented knee implants, highlighted by a single use tibial insert trial with embedded sensor technology (VERASENSE, Orthosensor Inc.), may offer an avenue to establish the relationship between tissue state and joint mechanics. Utilization of related data also has the potential to confirm computational predictions, where both rigid body motions and associated reactions are explicitly accounted for. Hence, the goal of this work was to evaluate an approach for optimization of ligament properties using joint mechanics data from an instrumented implant during laxity style testing. Such a framework could be used to inform joint balancing techniques, improve long term implant performance, and alternatively, qualify factors that may lead to poor outcomes. METHODS. Experimentation was performed on a 52 year old male, left, cadaveric specimen. Joint arthroplasty was performed using standard practice by an experienced orthopedic surgeon. To mimic passive intraoperative loading, laxity loading at 10°, 45° and 90° flexion, which consisted of discrete application of anterior-posterior (± 100N), varus-valgus (± 5 Nm) and internal-external (± 3 Nm) loads at each angle, was performed using a simVITROTM robotic musculoskeletal simulator (Cleveland Clinic, Cleveland, OH). Experimental results included relative tibiofemoral kinematics and sensor measured metrics (Fig 1). The finite element model was developed from specimen-specific MRIs and solved using Abaqus/Explicit. The model included the rigid bones, appropriately placed implants and relevant soft-tissue structures (Fig. 1). Ligament stiffness values were adopted from the literature and included a 6% strain toe region. Sets of nonlinear springs, defined using MR imaging, comprised each ligament/bundle. Optimization was performed, which minimized the root mean squared difference between VERASENSE measured tibiofemoral mechanics and the model predicted values. Ligament slack lengths were the control variables and the objective included each loading state and all contact metrics (θ, AFD, ML, and LL). RESULTS AND DISCUSSION. The model successfully recreated joint kinematics with average errors of 4° for rotations and 3 mm for translations, across all flexion angles (Fig 2). Though a systematic offset in θ was observed, model versus experiment contact locations were also in good agreement. Reaction forces were generally over-predicted by the model, but retained the overall trend (Fig 2). Sensitivity analysis also supported this finding. In light of the larger focus of this project, testing also included systematic removal of key tissues followed by repeat testing, as evaluated across numerous specimens. Overall, the presented framework represents a promising step towards establishing simulation based tools able to support exploratory studies as well as the clinical decision making process. Future work will evaluate efficacy across numerous specimens and assess sensitivity to key modeling and experimental parameters. To view tables/figures, please contact authors directly


Bone & Joint Research
Vol. 8, Issue 11 | Pages 509 - 517
1 Nov 2019
Kang K Koh Y Park K Choi C Jung M Shin J Kim S

Objectives

The aim of this study was to investigate the biomechanical effect of the anterolateral ligament (ALL), anterior cruciate ligament (ACL), or both ALL and ACL on kinematics under dynamic loading conditions using dynamic simulation subject-specific knee models.

Methods

Five subject-specific musculoskeletal models were validated with computationally predicted muscle activation, electromyography data, and previous experimental data to analyze effects of the ALL and ACL on knee kinematics under gait and squat loading conditions.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 343 - 343
1 May 2006
Adar E Gam A Halperin N Rzetelny V Hendel D
Full Access

Background: The embryology of the cruciate ligaments of the knee had received scant attention in the orthopaedic and embryologic literature. Understanding the embryonic development of the blood supply to criciate ligaments (CL) may help to comprehend the mechanisms of pathology leading to failure of these structures and of the revascularization process after reconstruction injured of cruciate ligaments or implantation of grafts. Aim: To describe the anatomy and spatial relationships of the cruciate ligaments and their blood supply in the developing fetus. Method: Knees from one leg of 48 normal human embryos from abortion material were examined, gestational age varying from early as the 8. th. week and up to the 20. th. week. Microscopic semi serial consequent sections of the knees were examined under light microscope and spatial changes within the cruciate ligaments were noted. The contra-lateral knees of some of the embryos were dissected to confirm the three dimensional picture. This gave us the possibility to follow the developmental changes of the spatial orientation of the cruciate ligaments and the blood vessels within them. Results: The anterior and posterior cruciate ligaments are formed from a single mass of cells, divided by a sinovial septum. Folds within the septum partially divide the ligaments into bundles and carry within them the vasculature needed to sustain the ligaments. We show that the blood supply of the growing CL arises from the middle genicular artery and enters the ligaments from the poster-superiolateral corner (P.S.L.C.) of the inter-condylar notch, passes between the ACL and PCL and descends along he posterior aspect of the ACL. These findings can explain why injury involving the P.S.L.C. in the adult has a worse prognosis for rehabilitation


Aims

Mobile-bearing unicompartmental knee arthroplasty (UKA) with a flat tibial plateau has not performed well in the lateral compartment, leading to a high rate of dislocation. For this reason, the Domed Lateral UKA with a biconcave bearing was developed. However, medial and lateral tibial plateaus have asymmetric anatomical geometries, with a slightly dished medial and a convex lateral plateau. Therefore, the aim of this study was to evaluate the extent at which the normal knee kinematics were restored with different tibial insert designs using computational simulation.

Methods

We developed three different tibial inserts having flat, conforming, and anatomy-mimetic superior surfaces, whereas the inferior surface in all was designed to be concave to prevent dislocation. Kinematics from four male subjects and one female subject were compared under deep knee bend activity.


Bone & Joint Research
Vol. 6, Issue 1 | Pages 31 - 42
1 Jan 2017
Kang K Koh Y Jung M Nam J Son J Lee Y Kim S Kim S

Objectives

The aim of the current study was to analyse the effects of posterior cruciate ligament (PCL) deficiency on forces of the posterolateral corner structure and on tibiofemoral (TF) and patellofemoral (PF) contact force under dynamic-loading conditions.

Methods

A subject-specific knee model was validated using a passive flexion experiment, electromyography data, muscle activation, and previous experimental studies. The simulation was performed on the musculoskeletal models with and without PCL deficiency using a novel force-dependent kinematics method under gait- and squat-loading conditions, followed by probabilistic analysis for material uncertain to be considered.


Bone & Joint Research
Vol. 8, Issue 3 | Pages 126 - 135
1 Mar 2019
Sekiguchi K Nakamura S Kuriyama S Nishitani K Ito H Tanaka Y Watanabe M Matsuda S

Objectives

Unicompartmental knee arthroplasty (UKA) is one surgical option for treating symptomatic medial osteoarthritis. Clinical studies have shown the functional benefits of UKA; however, the optimal alignment of the tibial component is still debated. The purpose of this study was to evaluate the effects of tibial coronal and sagittal plane alignment in UKA on knee kinematics and cruciate ligament tension, using a musculoskeletal computer simulation.

Methods

The tibial component was first aligned perpendicular to the mechanical axis of the tibia, with a 7° posterior slope (basic model). Subsequently, coronal and sagittal plane alignments were changed in a simulation programme. Kinematics and cruciate ligament tensions were simulated during weight-bearing deep knee bend and gait motions. Translation was defined as the distance between the most medial and the most lateral femoral positions throughout the cycle.


Bone & Joint Research
Vol. 6, Issue 11 | Pages 623 - 630
1 Nov 2017
Suh D Kang K Son J Kwon O Baek C Koh Y

Objectives

Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions.

Methods

Validated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated.


Objectives

Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA.

Methods

We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.


Bone & Joint Research
Vol. 5, Issue 11 | Pages 552 - 559
1 Nov 2016
Kang K Koh Y Son J Kwon O Baek C Jung SH Park KK

Objectives

Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments.

Materials and Methods

Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions.