Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 89 - 89
7 Nov 2023
Greenwood K Molepo M Mogale N Keough N Hohmann E
Full Access

The posterior compartments of the knee are currently accessed arthroscopically through anterior, posteromedial or posterolateral portals. A direct posterior portal to access the posterior compartments has been overlooked due to a perceived high-risk of injury to the popliteal neurovascular structures. Therefore, this study aimed to investigate the safety and accessibility of a direct posterior portal into the knee. This cross-sectional study comprised a sample of 95 formalin-embalmed cadaveric knees and 9 fresh-frozen knees. Cannulas were inserted into the knees, 16mm from the vertical plane between the medial epicondyle of the femur and medial condyle of the tibia and 8 and 14mm (females and males respectively) from the vertical plane connecting the lateral femoral epicondyle and lateral tibial condyle. Landmarks were identified in full extension and cannula insertion was completed with the formalin-embalmed knees in full extension and the fresh-frozen in 90-degree flexion. Posterior aspects of the knees were dissected from superficial to deep, to assess potential damage caused by cannula insertion. Incidence of neurovascular damage was 9.6% (n=10); 0.96% medial cannula and 8.7% lateral cannula. The medial cannula damaged one small saphenous vein (SSV) in a male specimen. The lateral cannula damaged one SSV, 7 common fibular nerves (CFN) and both CFN and lateral cutaneous sural nerve in one specimen. All incidences of damage occurred in formalin-embalmed knees. The posterior horns of the menisci were accessible in all specimens. A medial-lying direct posterior portal into the knee is safe in 99% of occurrences. The lateral-lying direct posterior portal is of high risk to the CFN


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 5 - 5
1 Nov 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Tibial cut is a crucial step in ensuring adequate and appropriate proximal tibial resection for mechanical orientation and axis in total knee replacement. We evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects individual mechanical orientation and alignment. We used Condylar Differential in 37 consecutive total knee replacements including valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis. The distances between the horizontal line and the lowest reproducible points of articular surfaces of medial and lateral tibial condyles respectively are measured. The difference between two measurements obviously represents Condylar Differential. Condylar Differential, adjusted to the nearest millimetre, is maintained in executing tibial cuts, successively if necessary. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualises the tibial cut for optimal templating of tibia. We encountered no problems, adopting this technique, in our series. Condylar Differential contributes to optimal individualised tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique in digitised radiographs, this technique can also be applied to plain films, allowing for magnification


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 145 - 145
1 Apr 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Background. Mechanics and kinematics of the knee following total knee replacement are related to the mechanics and kinematics of the normal knee. Restoration of neutral alignment is an important factor affecting the long-term results of total knee replacement. Tibial cut is a vital and crucial step in ensuring adequate and appropriate proximal tibial resection, which is essential for mechanical orientation and axis in total knee replacement. Tibial cut must be individually reliable, reproducible, consistent and an accurate predictor of individual anatomical measurements. Conventional tibial cuts of tibia with fixed measurements cannot account for individual variations. While computer navigated total knee replacement serves as a medium to achieve this objective, the technology is not universally applicable for differing reasons. Therefore we evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects the individual mechanical orientation and alignment. Methods. We used the Condylar Differential in 37 consecutive total knee replacements. We also applied the technique in valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on the digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis of tibia. The distances between the horizontal line and the lowest reproducible points of the articular surfaces of the medial and lateral tibial condyles respectively are measured. The difference between the two measurements obviously represents the Condylar Differential. Condylar Differential, adjusted to the nearest millimeter, is maintained in executing the tibial cuts, if necessary successive cuts. Results. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualizes the tibial cut for optimal templating of tibia in total knee replacement. We encountered no problems, adopting this technique, in our consecutive series of total knee replacements. Conclusions. Condylar Differential contributes to optimal individualized tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique of Condylar Differential in digitized radiographs, this technique can also be applied to plain films, allowing for the magnification


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 74 - 74
1 May 2016
Kanagawa H Kodama T Tsuji O Nakayama M Shiromoto Y Ogawa Y
Full Access

Introduction. We report a case which total knee arthroplasty (TKA) was able to be performed on schedule for the patient with occult fracture of proximal tibia which seemed to have occurred three months prior to the surgery, and has healed in short period of time by the use of Teriparatide. Case report. The patient is 84-year-old female, having right knee pain for past 7 years. Her knee pain increased by passive extension maneuver that was done by a bonesetter 3 months prior to the surgery. On her initial visit, the X-ray finding was severe medial osteoarthritis, and femorotibial angle (FTA) in the upright film was 197°, but there was no other disorder including fracture. Since the bone mineral density (BMD) of affected femoral neck was 62%YAM, and affected lateral femoral condyle as well as lateral tibial condyle seemed very porotic, we started using daily 20μg Teriparatide injection from 3 months prior to the surgery. Proximal tibial fracture was presented in the X-ray taken on the day before surgery, but since adequate bone union has already been formed, surgery was performed on schedule. Tibial implant with long stem was used for just to be certain. Thanks to the Teriparatide, the condition of cancellous bone in cut surface was excellent, and reaming of the tibia through fracture area felt very solid. Discussion. Proximal tibial fracture that occurred just before TKA is very rare. The fracture in this case was probably due to the maneuver done by the bonesetter. Teriparatide is indicated when osteoporosis is severe and the patient is at risk for fracture. We also indicate Teriparatide for the patients whose femoral neck BMD is very low and severe valgus knee or varus knee is present. Unloaded side of femoral or tibial condyle is usually very porotic in such a case. In our case, the fracture was so called fragility fracture which was found incidentally the day before surgery, but TKA could be done on schedule since adequate callus has been formed by the use of Teriparatide which started 3 months prior to the surgery


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 81 - 81
1 Jan 2016
Choi CH Chung KS Lee JK Lee HJ
Full Access

Introduction. The purpose of this study was to evaluate the mid-term clinical and radiological results in patients who were managed by double metal augmentations in proximal tibial uncontained bony defects undergoing primary or revision total knee arthroplasty. Materials and Methods. We performed double metal augmentations in proximal tibial uncontained bony defects undergoing total knee arthroplasty. Out of total 14 patients, 8 patients (4 priamry arthroplasty, 4 revision arthroplasty), mean 61.3 (50–80) years, were available for review at least 5 years follow up. The average follow up period was 86.3(60–99) months. Range of motion, American Knee Society Score were evaluated pre- and postoperatively as a clinical values. Another clinical assessments undertaken at the final reviews, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford knee score (OKS), Short Form-36 (SF-36), Lower extremity functional scale (LEFS), and Lower extremity activity scale (LEAS) were checked. Radiological results, involving presence of radiolucent lines (RLLs) > 1mm in width, and osteolysis at the block-cement-bone interface were taken under fluoroscopic images at postoperatively and annually thereafter. Results. At the final follow-up, range of motion was increased from 97.5° to 121.3° and American Knee society score was significantly improved from 30.4 to 92.6 (p=0.03) and functional score from 43.1 to 86.9 (p=0.03). At the final follow-up, average WOMAC score was 10(2–20), OKS was 40.5(33–47), LEFS was 55.8(34–75), and LEAS was 10.9(7–15). There was no broken or deterioration sign at between first and second metal block at radiographically. RLLs at the block-cement-bone interfaces under fluoroscopic images were examined in 3 knees, but didn't cause any failure sign such as osteolysis, or collapse, or instability at final reviews. Conclusions. The clinical and radiological evaluations showed that the double metal augmentations is a favorable and useful way to manage severe uncontained proximal tibial bony defects at least 5 years mid-term follow up period. Preoperative standing anteroposterior (AP) radiograph (Fig 1) shows severe uncontained proximal tibial bone defects, approximately 23 mm compared with unaffected lateral tibial condyle. AP view of fluoroscopy with medial double metal blocks (10 mm block + down sized 10 mm block) combined intramedullary stem at 60-month follow-up after primary total knee arthroplasty, demonstrating radiolucent line (white arrow) of 2.5 mm width bottom the block (Fig 2). AP view at 92-month follow-up indicating non-progressive stable radiolucent lines (white arrow) at same area without any radiographic failure signs and broken sign between first and second metal block (Fig 3)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 68 - 68
1 May 2016
Muratsu H Takemori T Matsumoto T Annziki K Kudo K Yamaura K Minamino S Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction. To achieve well aligned and balanced knee is essential for the post-operative outcome in total knee arthroplasty (TKA). Gap balancing technique can adjust the bone cut depending on the soft tissue balance in addition to soft tissue releases. Therefore, gap balancing technique would be more advantageous in soft tissue balance comparing to measured resection technique (MRT) in which soft tissue balancing relayed on soft tissue releases alone. Nevertheless, the influence of surgical technique on the post-operative knee stability has not been fully investigated. Objective. We introduced a new surgical technique (medial gap technique: MGT) according to modified gap technique regarding medial knee stability as important. The intra-operative soft tissue balance and post-operative knee stability were compared between MGT and MRT in posterior-stabilized (PS) TKA for varus type osteoarthritic knees. Materials & Methods. Sixty varus type osteoarthritis knees were involved in this study. PS type TKAs (NexGen LPS flexR) were performed using MGT in 30 knees (MGT group) and MRT in 30 knees (MRT group). The extension gap was made in the same manners in both groups. Both femoral and tibial bone cuts were perpendicular to the mechanical axis. Medial soft tissue releases were limited until the spacer block with the thickness corresponding to the resected lateral tibial condyle could be inserted. After extension gap was prepared, OFR-tensorR was used to assess soft tissue balance (center gap, varus angle) at extension and flexion prior to posterior femoral condyle bone resection. Both differences of the center gap and varus angle between at extension and flexion were calculated and used for size selection and external rotation angle of femoral component in MGT. The final joint component gaps were evaluated using OFR-tensorR with both femoral trial in place and patello-femoral joint reduced at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. Quantitative stress radiographies were performed at 1 month, 6 months and 1 year post-operatively to assess joint stability. Joint opening distance (mm) at both medial and lateral joint compartment were measured with knee extension and flexion. Each parameter was compared between MGT and MRT group using unpaired t-test (p<0.05). Results. Pre-operative factors showed no significant differences between 2 groups. The joint component gaps were significantly larger in MRT group from 45 to 135 degrees of flexion (Fig.1). The joint opening at the lateral compartment was significantly larger than medial at both knee extension and flexion in both groups. The joint openings were significantly larger bilaterally in MRT group comparing to MGT group at both extension and flexion (Fig.2, 3). Discussions. Medial instability has been reported as a possible reason for the persistent knee pain after TKA in the varus knees. We proposed a new surgical technique (MGT) not to deteriorate medial stability and allow lateral looseness in TKA. Post-operative knee stability was superior in MGT group comparing to MRT group from one month to one year after surgery. The difference of the intra-operative soft tissue balance might play an important role on the post-operative knee stability