Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 23 - 23
1 Nov 2018
Sano H Komatsuda T Inawashiro T Sasaki D Noguchi M Irie T Abe H Abrassart S
Full Access

Latarjet procedure (transfer of coracoid process to the anterior glenoid rim) has been widely used for severe anterior shoulder instability. The purpose of the present study was to investigate the intraarticular stress distribution after this procedure to clarify the pathomechanism of its postoperative complications. CT-DICOM data of the contralateral healthy shoulder in 10 patients with unilateral anterior shoulder instability (9 males and 1 female, age: 17–49) was used for the present study. Three-dimensional finite element models of the glenohumeral joint was developed using software, Mechanical Finder (RCCM, Japan). In each shoulder, a 25% bony defect was created in the anterior glenoid cavity, where coracoid process was transferred using two half-threaded screws. The arm position was determined as 0-degree and 90-degree abduction. While medial margin of the scapula was completely constrained, a standard compressive load (50 N) toward the centre of the glenoid was applied to the lateral wall of the greater tuberosity. A tensile load (20N) was also applied to the tip of coracoid process along the direction of conjoint tendon. Then, elastic analysis was performed, and the distribution pattern of Drucker-Prager equivalent stress was investigated in each model. The proximal half of the coracoid represented significantly lower equivalent stress than the distal half (p < 0.05). In particular, the lowest mean equivalent stress was seen in its proximal-medial-superficial part. On the other hand, a high stress concentration newly appeared in the antero-inferior aspect of the humeral head exactly on the site of coracoid bone graft. We assumed that the reduction of mean equivalent stress in the proximal half of the coracoid was caused by the stress shielding, which may constitute one of the pathogenetic factors of its osteolysis. A high stress concentration in the humeral head may eventually lead shoulder joint to osteoarthritis


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 117 - 117
1 Nov 2021
Longo UG
Full Access

The function of the upper extremity is highly dependent on correlated motion of the shoulder. The shoulder can be affected by several diseases. The most common are: rotator cuff tear (RCT), shoulder instability, shoulder osteoarthritis and fractures. Rotator cuff disease is a common disorder. It has a high prevalence rate, causing high direct and indirect costs. The appropriate treatment for RCT is debated. The American Academy Orthopaedic Surgeons guidelines state that surgical repair is an option for patients with chronic, symptomatic full-thickness RCT, but the quality of evidence is unconvincing. Thus, the AAOS recommendations are inconclusive. We are performing a randomized controlled trial to compare surgical and conservative treatment of RCT, in term of functional outcomes, rotator cuff integrity, muscle atrophy and fatty degeneration. Shoulder instability occurs when the head of the upper arm bone is forced out of the shoulder socket. Shoulder instabilities have been classified according to the etiology, the direction of instability, or on combinations thereof. The Thomas and Matsen classification, which is currently the most commonly utilized classification, divides shoulder instability events into the traumatic, unidirectional, Bankart lesion, and surgery (TUBS) and the atraumatic, multidirectional, bilateral, rehabilitation, and capsular shift (AMBRI) categories. The acquired instability overstress surgery (AIOS) category was then added. Surgical procedures for shoulder instability includes arthroscopic capsuloplasty, remplissage, bone block procedure or Latarjet procedure. Reverse total shoulder arthroplasty (RTSA) represents a good solution for the management of patients with osteoarthritis or fracture of the proximal humerus, with associated severe osteoporosis and RC dysfunction


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 13 - 13
1 Dec 2022
Barone A Cofano E Zappia A Natale M Gasparini G Mercurio M Familiari F
Full Access

The risk of falls in patients undergoing orthopedic procedures is particularly significant in terms of health and socioeconomic effects. The literature analyzed closely this risk following procedures performed on the lower limb, but the implications following procedures on the upper limb remain to be investigated. Interestingly, it is not clear whether the increased risk of falling in patients undergoing shoulder surgery is due to preexisting risk factors at surgery or postoperative risk factors, such as anesthesiologic effects, opioid medications used for pain control, or brace use. Only one prospective study examined gait and fall risk in patients using a shoulder abduction brace (SAB) after shoulder surgery, revealing that the brace adversely affected gait kinematics with an increase in the risk of falls. The main purpose of the study was to investigate the influence of SAB on gait parameters in patients undergoing shoulder surgery. Patients undergoing elective shoulder surgery (arthroscopic rotator cuff repair, reverse total shoulder arthroplasty, and Latarjet procedure), who used a 15° SAB in the postoperative period, were included. Conversely, patients age > 65 years old, with impaired lower extremity function (e.g., fracture sequelae, dysmorphism, severe osteo-articular pathology), central and peripheral nervous system pathologies, and cardiac/respiratory/vascular insufficiency were excluded. Participants underwent kinematic analysis at four different assessment times: preoperative (T0), 24 hours after surgery (T1), 1 week after surgery (T2), and 1 week after SAB removal (T3). The tests used for kinematic assessment were the Timed Up and Go (TUG) and the 10-meter test (10MWT), both of which examine functional mobility. Agility and balance were assessed by a TUG test (transitions from sitting to standing and vice versa, walking phase, turn-around), while gait (test time, cadence, speed, and pelvic symmetry) was evaluated by the 10MWT. Gait and functional mobility parameters during 10MWT and TUG tests were assessed using the BTS G-Walk sensor (G-Sensor 2). One-way ANOVA for repeated measures was conducted to detect the effects of SAB on gait parameters and functional mobility over time. Statistical analysis was performed with IBM®SPSS statistics software version 23.0 (SPSS Inc., Chicago, IL, USA), with the significant level set at p<0.05. 83% of the participants had surgery on the right upper limb. A main effect of time for the time of execution (duration) (p=0.01, η2=0.148), speed (p<0.01, η2=0.136), cadence (p<0.01, η2=0.129) and propulsion-right (R) (p<0.05, η2=0.105) and left (L) (p<0.01, η2=0.155) in the 10MWT was found. In the 10MWT, the running time at T1 (9.6±1.6s) was found to be significantly longer than at T2 (9.1±1.3s, p<0.05) and at T3 (9.0±1.3s, p=0.02). Cadence at T1 (109.7±10.9steps/min) was significantly lower than at T2 (114.3 ±9.3steps/min, p<0.01) and T3 (114.3±9.3steps/min, p=0.02). Velocity at T1 (1.1±0.31m/s) was significantly lower than at T2 (1.2± 0.21m/s, p<0.05). No difference was found in the pelvis symmetry index. No significant differences were found during the TUG test except for the final rotation phase with T2 value significantly greater than T3 (1.6±0.4s vs 1.4±0.3s, p<0.05). No statistically significant differences were found between T0 and T2 and between T0 and T3 in any of the parameters analyzed. Propulsion-R was significantly higher at T3 than T1 (p<0.01), whereas propulsion-L was significantly lower at T1 than T0 (p<0.05) and significantly higher at T2 and T3 than T1 (p<0.01). Specifically, the final turning phase was significantly higher at T2 than T3 (p<0.01); no significant differences were found for the duration, sit to stand, mid-turning and stand to sit phases. The results demonstrated that the use of the abduction brace affects functional mobility 24 hours after shoulder surgery but no effects were reported at longer term observations


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 33 - 33
1 Nov 2021
Hartland A Teoh K Rashid M
Full Access

Introduction and Objective. Tranexamic acid (TXA) is used across surgical specialties to reduce perioperative bleeding. It has been shown to be effective in trauma, spinal surgery, and lower limb arthroplasty. The aim of this study is to investigate the clinical effectiveness of TXA in all types of shoulder surgery on bleeding and non-bleeding related outcomes. Materials and Methods. This study was registered prospectively on the PROSPERO database (ref: CRD42020185482). A systematic review and meta-analysis of randomised controlled trials (RCTs) investigating intra-operative use of TXA versus placebo in any type of surgery to the shoulder girdle. Electronic databases searched included MEDLINE, EMBASE, PsychINFO, and the Cochrane Library. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and Jadad score. Certainty of findings were reported using the GRADE approach. The primary outcome was total blood loss. Secondary outcomes included patient reported outcome measures, adverse events, and rate of blood transfusion. Results. Eight RCTs were included in the systematic review and data from 7 of these studies pooled in the meta-analysis. A total of 708 patients were randomized across the studies (406 received TXA, 302 received placebo). Studies included patients undergoing anatomic or reverse total shoulder arthroplasty, open Latarjet surgery, and arthroscopic rotator cuff repair. Pooled analysis demonstrated significant reduction in perioperative bleeding with TXA compared to controls; estimated total blood loss (mean difference [MD], −209.66; 95% CI −389.11 to −30.21; p=0.02), and post-operative blood loss (via drain output) (MD, −84.8ml; 95% CI, −140.04 to −29.56; p=0.003). A mean difference in Visual Analogue Scale (VAS) of 2.93 was noted in favour of TXA (95% CI 0.2 to 5.66; p=0.04). Conclusions. Whilst noting some risk of bias within the studies, TXA was effective in reducing blood loss and pain in shoulder surgery. There may be a benefit of TXA use in both open and arthroscopic shoulder procedures. Larger, low risk of bias, RCTs for specific surgical shoulder procedures are required


Bone & Joint 360
Vol. 3, Issue 4 | Pages 35 - 38
1 Aug 2014
Hammerberg EM