The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.Aims
Methods
Revision total knee arthroplasty (rTKA) is a technically challenging and costly procedure. It is well-documented that primary TKA (pTKA) have better survivorship than rTKA; however, we were unable to identify any studies explicitly investigating previous rTKA as a risk factor for failure following rTKA. The purpose of this study is to compare the outcomes following rTKA between patients undergoing index rTKA and those who had been previously revised. This retrospective, observational study reviewed patients who underwent unilateral, aseptic rTKA at an academic orthopaedic speciality hospital between June 2011 and April 2020 with > one-year of follow-up. Patients were dichotomized based on whether this was their first revision procedure or not. Patient demographics, surgical factors, postoperative outcomes, and re-revision rates were compared between the groups.Aims
Methods
As has been shown in larger animal models, knee immobilization can lead to arthrofibrotic phenotypes. Our study included 168 C57BL/6J female mice, with 24 serving as controls, and 144 undergoing a knee procedure to induce a contracture without osteoarthritis (OA). Experimental knees were immobilized for either four weeks (72 mice) or eight weeks (72 mice), followed by a remobilization period of zero weeks (24 mice), two weeks (24 mice), or four weeks (24 mice) after suture removal. Half of the experimental knees also received an intra-articular injury. Biomechanical data were collected to measure passive extension angle (PEA). Histological data measuring area and thickness of posterior and anterior knee capsules were collected from knee sections.Aims
Methods
The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI? A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship.Aims
Methods
Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters. An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended.Aims
Methods
Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate.Aims
Methods
Ceramic coatings in total knee arthroplasty have been introduced with the aim of reducing wear and consequently improving implant survivorship. We studied both cobalt-chrome-molybdenum and ceramic-coated components of the same implant design from a single centre to identify if the ceramic coating conferred any benefit at mid-term review. We identified 1641 Columbus TKAs (Aesculap AG, Tüttlingen, Germany) from a prospectively collected arthroplasty database. 983 were traditional CoCrMo and 659 had the AS ceramic coating. Patients were followed up until death or revision of the implant.Abstract
Aims
Patients and Methods
This study aimed to assess the effect of PRP on knee articular cartilage content (thickness and/or volume) and establish if there is a correlation between changes in cartilage and clinical outcomes in patients with knee osteoarthritis. A systematic review was performed following the Cochrane methodology. Studies were included if they reported on cartilage content with MRI or Ultrasound before and after the injection. A random-effects model meta-analysis was performed.Abstract
Introduction
Methodology
Double-level knee osteotomy (DLO) is a challenging procedure that requires precision in preoperative planning and intraoperative execution to achieve the desired correction. It is indicated in cases of severe varus or valgus deformities where a single-level osteotomy would yield significantly tilted joint line obliquity (JLO). A single-centre, retrospective analysis of prospectively collected data for 26 patients, who underwent DLO by PSCGs for valgus malaligned knees. Post-operative alignment was evaluated and the delta for different lower limb alignment parameters were calculated; HKA, MPTA, and LDFA. At the two-year follow-up, changes in KOOS sub-scores, UCLA scores, lower limb discrepancy, and mean time to return to work and sport were recorded. All intraoperative and postoperative complications were recorded.Abstract
Introduction
Methods
Topical diclofenac has proven efficacy and safety in the management of osteoarthritic pain. Its therapeutic efficacy is dependent on its ability to deliver pharmacodynamically active concentrations to the underlying tissues in the affected joint. However, the disposition of topical diclofenac is not fully characterized, and no studies have been performed using diclofenac diethylamine 2.32% gel. This study investigated the penetration of topical diclofenac into knee synovial tissue and fluid and evaluated relative exposure in the knee versus plasma. In this phase 1, double-blind, placebo-controlled steady-state multicenter pharmacokinetic study, patients scheduled for arthroplasty to treat knee OA were randomly assigned 2:1 to 4 g diclofenac/placebo gel, applied to the affected knee every 12 hours for 7 days pre-surgery. Diclofenac concentrations were measured in synovial tissue, fluid, and plasma ≥12 hours after last application. Adverse events (AEs) were evaluated. Diclofenac concentrations were assayed by validated high-performance liquid chromatography and tandem mass spectrometry.Introduction
Methods
Unicompartmental knee arthroplasty (UKA) offers significant advantages over total knee arthroplasty (TKA) but is reported to have higher revision rates in joint registries. In both the New Zealand and the UK national registry the revision rate of cementless UKR is less than cementless. It is not clear whether this is because the cementless is better or because more experienced surgeons, who tend to get better results are using cementless. We aim to use registry data to compare cemented and cementless UKA outcomes, matching for surgical experience and other factors. We performed a retrospective observational study using National Joint Registry (NJR) data on 10,836 propensity matched Oxford UKAs (5418 cemented and 5418 cementless) between 2004 and 2015. Logistic regression was utilized to calculate propensity scores to match the cemented and cementless groups for multiple confounders using a one to one ratio. Standardised mean differences were used before and after matching to assess for any covariate imbalances. The outcomes studied were implant survival, reasons for revision and patient survival. The endpoint for implant survival was revision surgery (any component removal or exchange). Cumulative patient and implant survival rates were determined using the Kaplan-Meier method. Patients not undergoing revision or death were censored on the study end date. The study endpoints implant and patient survival were compared between cemented and cementless groups using Cox regression models with a robust variance estimator.Introduction
Methods
Release of tight lateral structures is an integral part of balancing the valgus knee during knee replacement surgery. The posterolateral capsule is released through an inside-out technique. The common peroneal nerve is in close proximity to the capsule during this step. This study was undertaken to determine the distance of the nerve and the safe level for the posterolateral release. MR scans of the knee of 100 patients were evaluated. The age range of selected patients was 50 to 70 years. The distance of the nerve was measured to the closest point on the posterolateral capsule. Two separate measurements were taken - one 9mm above the joint line indicating the distal femoral resection level and the other 9mm distal to the joint line indicating the level of tibial resection. A third point was at the joint line level. The position of the nerve was also recorded in relation to the cross section of the femur/tibia on a ‘clock-like’ reference.Purpose of the study
Methods
A prospective study of 276 TKA's performed in patients with valgus knee deformity ≥ 10° using a Modified Surgical Technique. Bone cuts were used to balance the valgus knee and soft tissue release was confined to the postero-lateral capsule in severe deformity. The aim was to restore a “functional mechanical axis” as opposed to a “neutral” mechanical axis. All surgeries were performed between Jan2003 and Apr2007, under the care of a single surgeon using an LCS rotating platform. All patients had full length radiographs and outcome scores collected prospectively. The mean coronal alignment of the lower limb was corrected from 15.9°(10-45°) to 3.8°. 94% patients had their coronal alignment restored to = 7°. Sixteen knees with postoperative valgus ≥8° were analysed as a separate group. The mechanical axis deviation was corrected from 52.3mm to 8.8mm. The distal femoral cut was made at 5° valgus in 131 knees(47.5%), 6° in 111 knees(40.2%) and 7° in 24 knees(8.7%).78 knees(28%) were balanced only with bone cuts. 198 knees(72%) had release of posterolateral capsule. 16 knees(5.8%) also had release of IT band. Lateral patellar release was performed in 39 knees (14%) and 23 knees had patella contouring. 93%knees had central patello-femoral alignment postoperatively. One spinout was managed by closed reduction and a second patient had revision of tibial tray for collapse. Patellar subluxation occurred in two patients. The oxford knee score and the American Knee Society clinical score improved from 48.5 to 26 and 21.04 to 86.03 respectively.MATERIALS AND METHODS
RESULTS
Kneeling ability is better in unicompartmental than total knee arthroplasty. There is also an impression that mobile bearing knees achieve better functional outcome than their fixed bearing cousins in unicompartmental and to a lesser extent total joint arthroplasty. In the UK, the market leading unicompartmental replacement is mobile bearing. To analyse kneeling ability after total and unicompartmental knee replacement using mobile and fixed bearing inserts.Introduction
Aim
Previous studies comparing cruciate retaining (CR) and cruciate sacrificing - posterior stabilised (PS) TKRs have failed to demonstrate a difference in outcomes based on numbers of patients recruited. This large study compares clinical outcomes in groups having PS and CR TKR and reports the results at 1 and 2 years post-operatively. A total of 683 patients undergoing TKR were consecutively enrolled in a prospective multi-centre study with 2 arms. In the first arm patients receiving a PS component were randomised to receive either a mobile bearing (176 patients) or fixed bearing (176 patients) implant. In the second arm, patients receiving a CR component were randomised to receive either a mobile bearing (161 patients) or fixed bearing (170 patients) implant. All patients were assessed preoperatively and at one and two years postoperatively using standard tools (Oxford, AKSS, Patellar Score) by independent nurse specialists. The data from the 2 arms of the trial were then analysed to compare differences between PS and CR implants.Introduction
Methods
Abstract. Patellofemoral Arthroplasty (PFA) is an alternative to TKA for patellofemoral osteoarthritis that preserves tibiofemoral compartments. It is unknown how implant positioning affects biomechanics, especially regarding the patella. This study analysed biomechanical effects of femoral and patellar component position, hypothesising femoral positioning is more important. Nine cadaveric knees were studied using a repeated-measures protocol.
Aims. The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA). Methods. A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case.
Aims. To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps. Methods. In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89).
The relationship between post-operative bone
density and subsequent failure of total knee replacement (TKR) is
not known. This retrospective study aimed to determine the relationship
between bone density and failure, both overall and according to
failure mechanism. All 54 aseptic failures occurring in 50 patients
from 7760 consecutive primary cemented TKRs between 1983 and 2004
were matched with non-failing TKRs, and 47 failures in 44 patients
involved tibial failures with the matching characteristics of age
(65.1 for failed and 69.8 for non-failed), gender (70.2% female), diagnosis
(93.6% OA), date of operation, bilaterality, pre-operative alignment
(0.4 and 0.3 respectively), and body mass index (30.2 and 30.0 respectively).
In each case, the density of bone beneath the tibial component was assessed
at each follow-up interval using standardised, calibrated radiographs.
Failing knees were compared with controls both overall and, as a
subgroup analysis, by failure mechanism.
Aims. An algorithm to determine the constitutional alignment of the lower limb once arthritic deformity has occurred would be of value when undertaking kinematically aligned total knee arthroplasty (TKA). The purpose of this study was to determine if the arithmetic hip-knee-ankle angle (aHKA) algorithm could estimate the constitutional alignment of the lower limb following development of significant arthritis. Methods. A matched-pairs radiological study was undertaken comparing the aHKA of an osteoarthritic knee (aHKA-OA) with the mechanical HKA of the contralateral normal knee (mHKA-N). Patients with Grade 3 or 4 Kellgren-Lawrence tibiofemoral osteoarthritis in an arthritic knee undergoing TKA and Grade 0 or 1 osteoarthritis in the contralateral normal knee were included. The aHKA algorithm subtracts the lateral distal femoral angle (LDFA) from the medial proximal tibial angle (MPTA) measured on standing long leg radiographs. The primary outcome was the mean of the paired differences in the aHKA-OA and mHKA-N. Secondary outcomes included comparison of sex-based differences and capacity of the aHKA to determine the constitutional alignment based on degree of deformity. Results. A total of 51 radiographs met the inclusion criteria. There was no significant difference between aHKA-OA and mHKA-N, with a mean angular difference of −0.4° (95% SE −0.8° to 0.1°; p = 0.16). There was no significant sex-based difference when comparing aHKA-OA and mHKA-N (mean difference 0.8°; p = 0.11).