Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 13 - 13
1 Mar 2012
Kulkarni A Jameson S James P Woodcock S Reed M
Full Access

Background

Total Knee Replacement (TKR) is technically demanding, time consuming and has higher complication rates in super obese (BMI>45) patients. Bariatric surgery can be considered for such patients prior to TKR although its effect on complications is unknown.

Methods

All patients who underwent bariatric surgery and a TKR in the NHS in England between 2005 and 2009 were included. Hospital episode statistics data in the form of OPCS, ICD10 codes were used to establish 90-day DVT, PE and mortality rates (inpatient and outpatient). In addition, readmission to orthopaedics, joint revision and ‘return to theatre for infection’ rates were also established. Code strings for each patient were examined in detail to ensure the correct gastric procedures were selected. Fifty-three patients underwent bariatric surgery then TKR (44-1274 days) (group 1). Thirty-one patients underwent TKR then bariatric surgery (33-1398 days) (group 2).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 5 - 5
1 Jul 2012
McKenna R Winter A Rooney B Leach W
Full Access

Aim. We aim to compare revision rates and functional outcome scores in between two contemporary total knee arthoplasty systems. Methods. A search was carried out of a prospectively maintained outcomes database to identify all patients receiving total knee replacement (TKR) in the department between 2005 and 2006, when evaluation of different knee arthroplasty systems was being undertaken. Data on the first 93 consecutive patients receiving a Scorpio (Stryker, Allendale, NJ) implant and the first 93 consecutively receiving a PFC (DePuy, Warsaw, IN) implant were reviewed. Four year revision rates and functional scores were recorded. Results. Patient demographics were similar in both groups. Six of ninety three Scorpio implants were listed for revision over the four year period (6%). Five of these were for aseptic loosening. Three further patients are currently being investigated for pain and have radiological evidence of loosening with no clinical evidence of infection. No PFC implants required revision in the four year period (p = 0.013). There was no difference in Oxford Scores pre-operatively, or at 3 months, 1 year and 2 years post-operatively. Discussion. There is a significant difference in revision rates between the two prostheses, and the revision rate of the Scorpio prosthesis is far higher than would be expected. The majority of these have been revised for aseptic loosening. Those prostheses surviving to four years had similar clinical outcomes. The reasons for this higher than expected revision rate in the Scorpio group require further exploration


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims

The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes.

Methods

A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 185 - 190
1 Jun 2021
Kildow BJ Patel SP Otero JE Fehring KA Curtin BM Springer BD Fehring TK

Aims

Debridement, antibiotics, and implant retention (DAIR) remains one option for the treatment of acute periprosthetic joint infection (PJI) despite imperfect success rates. Intraosseous (IO) administration of vancomycin results in significantly increased local bone and tissue concentrations compared to systemic antibiotics alone. The purpose of this study was to evaluate if the addition of a single dose of IO regional antibiotics to our protocol at the time of DAIR would improve outcomes.

Methods

A retrospective case series of 35 PJI TKA patients, with a median age of 67 years (interquartile range (IQR) 61 to 75), who underwent DAIR combined with IO vancomycin (500 mg), was performed with minimum 12 months' follow-up. A total of 26 patients with primary implants were treated for acute perioperative or acute haematogenous infections. Additionally, nine patients were treated for chronic infections with components that were considered unresectable. Primary outcome was defined by no reoperations for infection, nor clinical signs or symptoms of PJI.