Advertisement for orthosearch.org.uk
Results 1 - 20 of 32
Results per page:
Full Access

We report the outcome of 320 primary Total Hip Arthroplasties (THA) with minimum 10-year follow-up (range 10–17 years, mean 12.6 years), performed by a single surgeon in Tauranga New Zealand, with the Exeter Contemporary Flanged all-polyethylene cup and Exeter femoral stem via a posterior approach. The aim of the study is to compare the results with the published results from the design centre and create a baseline cohort for further outcomes research in this centre. All patients were prospectively followed at 6 weeks, 1 year, 5 years, 10 years, (and 15 years when available). Of 333 cases that matched the inclusion criteria, 13 procedures in 12 patents were excluded because of concomitant bone grafting and/or supplementary cage fixation, leaving 320 primary THA procedures in 280 patients, including 26 bilateral procedures in 13 patients. Mean follow-up of the surviving cases was 12.6 (range 5.0-17.1) years. There were 12 revisions – 2 for fracture, 5 for instability, 1 for impingement pain and 4 for infection. There were no revisions for aseptic cup loosening. Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 100% at 15.0 years (with minimum 40 cases remaining at risk). All-cause acetabular revision in 12 cases result in a Kaplan-Meier survival of 95.9% (95% CI: 93.5 to 98.3%). Cemented THA with the Exeter Contemporary Flanged cup and the Exeter stem is a durable combination with results that can be replicated outside of the design centre. The Exeter Contemporary Flanged cup has excellent survivorship at 15 years when used with the Exeter stem. Cemented THA with well-proven components should be considered the benchmark against which newer designs and materials should be compared


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 31 - 31
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 – 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 56 - 56
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 - 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 51 - 51
1 Oct 2022
Azamgarhi T Scobie A Karunaharan N Mepham SO Mack D Vekaria K Crick K Chin SH Warren S
Full Access

Aim. There is a lack of data supporting the use of doxycycline as a single agent after removing infected orthopaedic metalwork. We evaluated the efficacy and safety of doxycycline compared with other single antibiotic regimens used at our specialist orthopaedic hospital. Methods. A retrospective observational study including all adult patients diagnosed with an orthopaedic metalwork infection due to staphylococci. All patients were managed with the removal of metalwork, and multiple intraoperative samples were sent for culture, followed by the administration of at least four weeks of oral antibiotics. Antibiotic selection was on the recommendation of an infection consultant. Infection outcome was assessed as the proportion of patients meeting the OVIVA Trial definition of definite failure at follow-up. The probability of definite failure for doxycycline and the alternatives group was estimated using the Kaplan-Meier survival method. All adverse drug reactions (ADR) during treatment were analysed. Results. Seventy-nine orthopaedic metalwork infections were identified between July 2017 and July 2021. Forty-four were prosthetic joints, and 35 were fracture-related metalwork. In 54 cases, the infecting organism was Staphylococcus aureus, and 25 were due to coagulase-negative staphylococci. Forty-four were treated with doxycycline 100mg 12 hourly, and 35 were treated with alternatives (flucloxacillin 1g 6-hourly n=21 and clindamycin 450mg 6-hourly n=14). Overall, 70 patients (88.6%) were infection-free after a median follow-up of 23 months (IQR, 19 – 44). 38 (82.3%) were infection-free in the doxycycline group compared with 32 (91.4%) patients treated with alternatives. Of the failures in the alternatives group, all 3 received flucloxacillin. Survival analysis showed no significant difference in time to treatment failure between doxycycline and alternative antibiotics. Eighteen patients experienced an ADR: 2 nausea, one rash and one vaginal candidiasis due to doxycycline. Four diarrhoea, one reflux, two rashes and one headache due to clindamycin; 1 nausea and five diarrhoea due to flucloxacillin. Four patients required discontinuation therapy, two due to clindamycin and two due to flucloxacillin. Conclusions. In our cohort of patients, doxycycline monotherapy was an effective and well-tolerated oral option for treating staphylococcal infection following debridement and removal of orthopaedic metalwork


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 42 - 42
1 Dec 2022
Fransen B Howard L MacDonell T Bengoa F Garbuz D Sheridan G Neufeld M
Full Access

Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the long-term survival and revision rates of HXLPE liners in primary THA, as well as the effect of liner thickness on these outcomes. We hypothesized that there would be no significant differences between the different liner thicknesses. We performed a retrospective database analysis from a single center of all primary total hip replacements using HXLPE liners from 2010 and earlier, including all femoral head sizes. All procedures were performed by fellowship trained arthroplasty surgeons. Patient characteristics, implant details including liner thickness, death, and revisions (all causes) were recorded. Patients were grouped for analysis for each millimeter of PE thickness (e.g. 4.0-4.9mm, 5.0-5.9mm). Kaplan-Meier survival estimates were estimated with all-cause and aseptic revisions as the endpoints. A total of 2354 patients (2584 hips) were included (mean age 64.3 years, min-max 19-96). Mean BMI was 29.0 and 47.6% was female. Mean follow-up was 13.2 years (range 11.0-18.8). Liner thickness varied from 4.9 to 12.7 mm. Seven patients had a liner thickness <5.0mm and 859 had a liner thickness of <6.0mm. Head sizes were 28mm (n=85, 3.3%), 32mm (n=1214, 47.0%), 36mm (n=1176, 45.5%), and 40mm (n=109, 4.2%), and 98.4% were metal heads. There were 101 revisions, and in 78 of these cases the liner was revised. Reason for revision was instability/dislocation (n=34), pseudotumor/aseptic lymphocyte-dominant vasculitis associated lesion (n=18), fracture (n=17), early loosening (n=11), infection (n=7), aseptic loosening (n=4), and other (n=10). When grouped by liner thickness, there were no significant differences between the groups when looking at all-cause revision (p=0.112) or aseptic revision (p=0.116). In our cohort, there were no significant differences in all-cause or aseptic revisions between any of the liner thickness groups at long-term follow-up. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA does not lead to increased complications or liner failures at medium to long term follow-up. As such, orthopedic surgeons can consider the use of larger heads at the cost of liner thickness a safe practice to reduce the risk of dislocation after THA when using HXLPE liners


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 5 - 5
1 Dec 2022
Li T Beaudry E Westover L Chan R
Full Access

The Adams-Berger reconstruction is an effective technique for treating distal radioulnar joint (DRUJ) instability. Graft preparation techniques vary amongst surgeons with insufficient evidence to support one technique over another. Our study evaluated the biomechanical properties of four graft preparation techniques. Extensor tendons were harvested from fresh frozen porcine trotters obtained from a local butcher shop and prepared in one of three configurations (n=5 per group): tendon only; tendon prepared with non-locking, running suture (2-0 FiberLoop, Arthrex, Naples, FL) spaced at 6 mm intervals; and tendon prepared with suture spaced at 12 mm intervals. A fourth configuration of suture alone was also tested. Tendons were allocated in a manner to ensure comparable average diameters amongst groups. Biomechanical testing occurred using custom jigs simulating radial and ulnar tunnels attached to a Bose Electroforce 3510 mechanical testing machine (TA Instruments). After being woven through the jigs, all tendons were sutured end-to-end with 2-0 PROLENE suture (Ethicon). Tendons then underwent a staircase cyclic loading protocol (5-25 Newtons [N] at 1 hertz [Hz] for 1000 cycles, then 5-50 N at 1 Hz for 1000 cycles, then 5-75 N at 1 Hz for 1000 cycles) until graft failure; if samples did not fail during the protocol, they were then loaded to failure. Samples were visually inspected for mode of failure after the protocol. A one-way analysis of variance was used to compare average tendon diameter; post-hac Tuhey tests were used to compare elongation and elongation rate. Survival to cyclic loading was analyzed using Kaplan-Meier survival curves with log rank. Statistical significance was set at a = 0.05. The average tendon diameter of each group was not statistically different [4.17 mm (tendon only), 4.33 mm (FiberLoop spaced 6 mm), and 4.30 mm (FiberLoop spaced 12 mm)]. The average survival of tendon augmented with FiberLoop was significantly higher than tendon only, and all groups had significantly improved survival compared to suture only. There was no difference in survival between FiberLoop spaced 6 mm and 12 mm. Elongation was significantly lower with suture compared to tendon augmented with FiberLoop spaced 6 mm. Elongation rate was significantly lower with suture compared to all groups. Modes of failure included rupture of the tendon, suture, or both at the simulated bone and suture and/or tendon interface, and elongation of the entire construct without rupture. In this biomechanical study, augmentation of porcine tendons with FiberLoop suture spaced at either 6 or 12 mm for DRUJ reconstruction significantly increased survival to a staircase cyclic loading protocol, as suture material was significantly stiffer than any of the tendon graft configurations


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 29 - 29
1 Dec 2019
Karbysheva S Cabric S Margaryan D Trampuz A
Full Access

Aim. We evaluated the efficacy and safety of treatment regimens in a pathogen and surgery specific mode according to a standardized algorithm for the treatment of periprosthetic joint infection (PJI) based on combinations with 15g/d intravenous fosfomycin followed by oral antibiotics for totally 12 weeks. Method. Consecutive patients with PJI caused by at least one of the following isolates were prospectively included: staphylococci (MIC ≤32 mg/l), streptococci (MIC ≤128 mg/l), enterococci (MIC ≤128 mg/l), Enterobacteriaceae (MIC ≤32 mg/l) and Pseudomonas spp. (MIC ≤128 mg/l). PJI was defined by the proposed European Bone and Joint Infection Society (EBJIS) criteria. Follow up with clinical (joint function and quality of life scores), laboratory and radiological evaluation at 3, 12 and 24 months after last surgery is performed. Infection outcome was assessed as the proportion of infection-free patients. The probability of infection-free survival was estimated using the Kaplan-Meier survival method. Results. 50 patients were screened for eligibility, of which 2 were excluded due to intolerance or allergy to fosfomycin, 1 due to isolation of fosfomycin resistant pathogen and 2 patients died due to unrelated cause to infection. The remaining 45 patients were included. Due to persistence of infection, 3 patients underwent prosthesis explantation after initial debridement and retention, 1 patient underwent debridement of Girdlestone-situation; all 4 infections were caused by S. aureus. At 2 patients debridement of hematoma after Girdlestone approach was performed. 41 patients were infection-free (91%) after a median follow-up of 6 month (range, 1 – 14 months). Nausea (n=14) and hypokalemia (n=13) were the most frequent adverse events and resolved after fosfomycin discontinuation; 5 patients had diarrhea and vomiting was observed in 2 patients. Isolated pathogens were staphylococci (n=30), streptococci (n=3), enterococci (n=5) and gram-negative rods (n=2). Cultures were negative in 9 patients and polymicrobial in 2 patients. The infection occurred postoperatively in 31 patients (69%) and hematogenously in 14 (31%). Two-stage exchange was performed in 27 (60%), debridement with retention in 13 (29%) and one-stage exchange in 5 patients (11%). Conclusions. The applied PJI treatment algorithm including intravenous fosfomycin in the initial postoperative period was associated with infection-free outcome of 91% after a median follow-up of 6 month. The Kaplan-Meier survival method showed the probability of infection-free survival of 88.5% after 1 year. Adverse events occurred in 21 patients (46%) mostly nausea and hypokalemia were reported. Adverse events were mild and resolved completely


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 38 - 38
1 Feb 2021
Hickey M Anglin C Masri B Hodgson A
Full Access

Introduction. Innovations in surgical robotics and navigation have significantly improved implant placement accuracy in total knee arthroplasty (TKA). However, many comparative studies have not been shown to substantially improve revision rates or other clinical outcome scores. We conducted a simulation study based on the reported distribution of patient-specific characteristics and estimated potential effect of coronal plane alignment (CPA) on risk of revision to evaluate the hypothesis that most published study designs in this area have been too underpowered to detect improvements in revision rates. Methods. To model previously reported studies, we generated a series of simulated TKA patient populations, assigning each patient a set of patient-specific factors (age at index surgery, BMI, and sex (Fig.1a)), as well as one surgeon-controlled factor (CPA) (Fig.1b) based on registry data and published literature. We modelled the survival probability for an individual patient at time t as a Gaussian function (exp[-(t/(k∗τ. max. )). 2. ]), where τ. max. (99.5 years) is selected to ensure the mean survival probability of the patient population matched 92% at 15 years. The value of k was adjusted for simulated patients within a range of 0 to 1 as a function of their patient and surgeon-specific factors (Fig.2). To evaluate power associated with a study design, we ran a Monte Carlo simulation generating 10,000 simulated populations of ten different cohort sizes. We divided the patient population into two groups: one group was assigned CPAs governed by the precision of a navigated/robotic approach (σ=1.5°), and the other CPAs governed by the precision of a conventional approach (σ=3°). We then simulated the time to failure for each patient, computed the corresponding Kaplan-Meier survival curves, and applied a Log-Rank test to each study to test for statistical difference. From the 10,000 simulations associated with each cohort size, we determined the percentage of simulated studies that found a statistically significant difference at each time point. Results. Figure 3 shows a contour plot illustrating the probability that a survival analysis with a specific study design would find statistical significance between the conventional and navigated/robotic patient groups. Entries from recently published literature are overlaid for context. No studies achieved statistical significance (p<0.05). Discussion. The effectiveness of navigated/robotic surgery is one of the most controversial debates in orthopedic surgery. The results from this simulation suggest that most revision studies aiming to settle this debate are likely significantly underpowered, falling below the normal 80% threshold. Limitations of this analysis include using only a single surgeon-controlled variable in the survival simulation, and only a single precision for the navigated/robotic approaches. Further studies will include more implant-related risk factors and a wider range of precisions for navigated/robotic procedures. Based on this simulation, it appears the effect size afforded by navigated/robotic surgeries on revision rates in TKA surgery is too small to recommend broad application, especially since adoption could involve added costs and unforeseen risks associated with novelty. Clinically, it may be beneficial to examine the use of robotics/navigation on high-risk patients, where studies are likely to have higher power due to larger effect sizes. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 124 - 124
1 Jul 2020
Woodmass J Wagner E Borque K Chang M Welp K Warner J
Full Access

Chronic massive irreparable rotator cuff tears represent a treatment challenge and the optimal surgical technique remains controversial. Superior capsular reconstruction (SCR) has been proposed as a means to provide superior stability to the glenohumeral joint, thus facilitating restoration of shoulder function. However, despite the growing use of SCR there is a paucity of data evaluating the outcomes when performed using a dermal allograft. The purpose of this study was to (1) report the overall survival rate (reoperation and clinical failure) of SCR (2) evaluate for pre-operative factors predicting reoperation and clinical failure. From January 1, 2015 to November 31, 2017, 65 patients were diagnosed with irreparable rotator cuff tears and consented for a superior capsular reconstruction. These surgeries were performed by 6 surgeons, all fellowship trained in either sports or shoulder and elbow fellowships. Outcomes were graded as excellent, satisfactory, or unsatisfactory using the modified Neer scale. An unsatisfactory result was defined as a clinical “failure”. The Kaplan-Meier survival models were created to analyze reoperation-free and failure-free survival for the entire group. The reconstruction was performed using a dermal allograft. There were 31 patients excluded due to insufficient follow-up (< 6 months), leaving 34 included in this study. The mean follow-up was 12 months (range, 6–23). The average number of prior surgeries was 0.91 (range, 0–5), with 52.9% of patients receiving a prior rotator cuff repair and 38.2% of patients with a prior non-rotator cuff arthroscopy procedure. The one and two-year survival-free of surgery was 64% and 44% and the one and two-year survival free of failure was 34% and 16% following SCR, respectively. For the patients that underwent a reoperation, 62.5% (n= 5/8) underwent reverse shoulder replacements, 25% (n= 2/8) latissimus dorsi tendon transfers, and 12.5% (n= 1/8) a diagnostic arthroscopy. The average period between the primary and revision surgery was 10.2 months (range, 2.1–18.5). All but two patients (75%, n= 6/8) had at least one surgery prior to the SCR. There were 14/34 (41.2%) patients who experienced pain, weakness, and restricted range of motion. These patients were defined as clinical failures with an unsatisfactory grading on Neer's criteria. Previous surgery predicted reoperation (80% vs 43%, p = 0.03). Female gender predicted clinical failure (100% vs 43%, p < 0 .01). Superior Capsule Reconstruction performed for large to massive rotator cuff tears has a high rate of persistent pain and limited function leading to clinical failure in 65% (n= 22/34) of patients. The rate of failure is increased in revision cases, female gender and increased Goutallier fatty infiltration of the infraspinatus. Narrowed indications are recommended given the surgical complexity and high rate of early failure


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 70 - 70
1 Jun 2018
Gross A
Full Access

In our center the cup cage reconstruction is our most common technique where a cage is used, especially if there is a pelvic discontinuity. Cup Cage Construct – in this construct there must be enough bleeding host bone to stabilise the ultraporous cup which functions like a structural allograft supporting and eventually taking the stress off the cage. This construct is ideal for pelvic discontinuity with the ultraporous cup, i.e., bridging and to some degree distracting the discontinuity. If, however, the ultra-porous cup cannot be stabilised against some bleeding host bone, then a conventional stand-alone cage must be used. Acetabular bone loss and presence of pelvic discontinuity were assessed according to the Gross classification. Sixty-seven cup cage procedures with an average follow-up of 74 months (range, 24–135 months; SD, 34.3 months) were identified; 26 of 67 (39%) were Gross Type IV and 41 of 67 (61%) were Gross Type V (pelvic discontinuity). Failure was defined as revision surgery for any cause, including infection. The 5-year Kaplan-Meier survival rate with revision for any cause representing failure was 93% (95% confidence interval, 83.1–97.4), and the 10-year survival rate was 85% (95% CI, 67.2–93.8). The Merle d'Aubigné-Postel score improved significantly from a mean of 6 pre-operatively to 13 post-operatively (p < 0.001). Four cup-cage constructs had non-progressive radiological migration of the ischial flange and they remain stable


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 11 - 11
1 Dec 2017
Confalonieri N Manzotti A Biazzo A
Full Access

Introduction. At a minimum 12 years follow-up the Authors performed a matched paired study between 2 groups: Bi-Unicompartimental (femoro-tibial) versus Total Knee Replacements, both navigated, they hypothesised that Bi-UKR guarantees a clinical score and patient satisfaction at least similar to TKR without differences in survivorship. Materials and Methods. 19 BI-UKR (1999–2003) were included in the study (group A). Every single patients in group A was matched to a computer-assisted TKR implanted in the same period (group B). The clinical outcome was evaluated using the Knee Society Score, the GIUM Score and the WOMAC Arthritis Index. Radiographically the HKA angle and the Frontal Tibial Component angle (FTC) were. Statistical analysis of the results was performed and Kaplan-Meir survival rate was assessed in both the groups. Results. No statistically significant difference was seen for the Knee Society, Functional and GIUM scores between the 2 groups. Statistically significant better WOMAC Function and Stiffness indexes were registered for the Bi-UKR group. All the TKR implants still remained positioned within 4 degrees of an ideal HKA angle of 180° and ideal FTC angle of 90° with a statistically significant better alignment compared to the Bi-UKR group. The Kaplan-Meier survival did not show any statistical significant differences in survivorship. Discussion. At 12 years minimum follow-up there are no significant differences in survivorship and clinical score despite a worse implant alignment WOMAC function and stiffness scores are still statistically better in the Bi-UKR group


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 33 - 33
1 Apr 2018
Song M Kim Y Yoo S Kang S Kwack C
Full Access

Purpose. Unicompartmental Knee Arthroplasty (UKA) has been indicated for inactive elderly patients over 60, but for young and active patients less than 60 years old, it has been regarded as a contraindication. The purpose of this study is to evaluate the usefulness of UKA performed on young Asian patients under 60 years of age by analyzing clinical outcomes, complications and survival rate. Materials and Methods. The subjects were 82 cases, which were followed up for at least 5 years (from 5 to 12 years). Only Oxford phase III® (Biomet Orthopedics, Inc, Warsaw, USA) prosthesis was used for all cases. The clinical evaluation was done by the range of motion, Knee society score (KSS), WOMAC score. The radiographic evaluation was performed on weight bearing long-leg radiographs, AP and lateral view of the knee and skyline view of the patella. The survival rate was estimated by Kaplan-Meier survival analysis. Results. Three bearing dislocations, one medial tibial collapse and one lateral osteoarthritis occurred, so the complication rate was 6.1% (5/82). Among the 3 cases of bearing dislocation, 2 cases were resolved by replacing with a thicker bearing and 1 case was converted to TKA due to repeated dislocation. One case of medial tibia collapse and one lateral osteoarthritis were converted to total knee arthroplasty (TKA). All clinical outcomes measured by KSS scores and WOMAC score showed a statistically significant difference (p<0.001). The 10 year cumulative survival rate using Kaplan-Meier survival method was 94.7% (95% CI: 88.7%–100%). Conclusion. The clinical outcomes and the survival rate of young asian patients less than 60 years of age who underwent Oxford medial UKA showed good clinical results and a good survival rate in the mid-term results. However, long-term follow-up is needed for more reliable clinical results


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 63 - 63
1 Apr 2019
Micera G Moroni A Orsini R Mosca S Fabbri D Sinapi F Miscione MT Acri F
Full Access

Introduction. The aim of this study was to analyze the results of our series of female patients treated with <48 mm MOMHR devices at a minimum follow-up of 5 years, to understand which is the most important aspects affecting the results and to define if the metal ions dosage has to be indicated as a routinely follow-up. Methods. This is a retrospective clinical study; the cohort included 198 consecutive MOMHR implanted in 181 female patients (17 bilateral procedures). All operations were performed between 2002 and 2011. All operations were performed by the senior surgeon. Indications to MOMHR included primary or secondary osteoarthritis (OA), rheumatoid arthritis and avascular necrosis. Contraindications included poor proximal femoral bone stock (T-score<−2.5sd in BMD of the femoral neck) or severely distorted hip anatomy. All patients were advised to underwent clinical and radiological review with the operating surgeon at 5 weeks, 3, 6 and 12 months postoperatively and then every subsequent 2 years.182 patients answered to our phone calls; 4 patients died (one of them was operated bilaterally) for causes not related to the study, and in 11 cases the phone number was expired. The minimum follow-up was 5.0 years (mean 7.5, maximum 13.2, sd 0.11). Results. Fourteen devices were revised (7%) in 14 patients: 2 of them were operated bilaterally and the controlateral implant is still fine; thus, the Kaplan-Meier survival rate with revision for any reason as the end point was 92.7% at 13 years (95% confidence interval (CI) 0.9 to 1.0). Revisions data are resumed in table 2. Main OHS was 44 points (4–48, sd 7); no statistical relations were found about any aspect about relation between OHS and metal ions dosage (eg Chi Square Analysis p-value = 0.147>0,05 for Score and CR). Metal ions dosage was performed in only 2 cases before and after the revision (14%); in one case, the Cr dosage was 20 µg/L before and 8 µg/L after surgery; in the other case, the Cr dosage was 100 µg/L before and 10 µg/L after surgery, and the Co dosage was 70 µg/L before and 0.2 µg/L after surgery. Metal ions dosage was performed in 64 cases of the survived implants (35%). Main Cr dosage was 1.50 µg/L (0.09–7.00, sd 1.70) and main Co dosage was 1.30 µg/L (0.09–9.00, sd 1.60), at a main follow-up from surgery of 5.7 years (0.2–11.0, sd 3.1), in 14 different laboratories. No statistical relation were found between clinical outcomes and metal ions increase. Conclusions. MOMHR is a good choice for treating severe hip arthritis also in female patients with <48 mm devices. The results are affected especially by surgical technique and indications. The metal ions dosage has to be performed every year for the first two years and then at a larger follow-up. We believe that additional imaging, such as CT scanning to measure anteversion may better identify the ideal candidate, and specific training with largely experienced surgeons would be mandatory; the metal ions dosage would be used as a monitor of failures


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 101 - 101
1 Aug 2017
Gross A
Full Access

Acetabular cages are necessary when an uncemented or cemented cup cannot be stabilised at the correct anatomic level. Impaction grafting with mesh for containment of bone graft is an alternative for some cases in centers that specialise in this technique. At our center we use three types of cage constructs –. (A). Conventional cage ± structural or morselised bone grafting. This construct is used where there is no significant bleeding host bone. This construct is susceptible to cage fatigue and fracture, This reconstruction is used in young patients where restoration of bone stock is important. (B). Conventional cage in combination with a porous augment where contact with bleeding host bone can be with the ilium and then by the use of cement that construct can be unified. The augment provides contact with bleeding host bone and if and when ingrowth occurs, the stress is taken off the cage. (C). Cup-Cage Construct – in this construct there must be enough bleeding host bone to stabilise the ultra-porous cup which functions like a structural allograft supporting and eventually taking the stress off the cage. This construct is ideal for pelvic discontinuity with the ultra-porous cup, i.e., bridging and to some degree distracting the discontinuity. If, however, the ultra-porous cup cannot be stabilised against some bleeding host bone, then a conventional stand-alone cage must be used. In our center the cup-cage reconstruction is our most common technique where a cage is used, especially if there is a pelvic discontinuity. Acetabular bone loss and presence of pelvic discontinuity were assessed according to the Gross classification. Sixty-seven cup-cage procedures with an average follow-up of 74 months (range, 24–135 months; SD, 34.3) months were identified; 26 of 67 (39%) were Gross Type IV and 41 of 67 (61%) were Gross Type V (pelvic discontinuity). Failure was defined as revision surgery for any cause, including infection. The 5-year Kaplan-Meier survival rate with revision for any cause representing failure was 93% (95% confidence interval, 83.1–97.4), and the 10-year survival rate was 85% (95% CI, 67.2–93.8). The Merle d'Aubigné-Postel score improved significantly from a mean of 6 pre-operatively to 13 post-operatively (p < 0.001). Four cup-cage constructs had non-progressive radiological migration of the ischial flange and they remain stable


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 81 - 81
1 May 2016
Neuhofer S Hochreiter J Emmanuel K
Full Access

Purpose. The aim of the current study was to evaluate the clinical and radiographic results of primary total hip arthroplasty (THA) performed with the Alloclassic Variall system (a modified version of the Alloclassic Zweymüller system) and to compare them with those in the literature for the original system. Methods. Between January 2001 and December 2002, 273 consecutive primary THAs were performed in 259 patients at a single centre with the study system, using ceramic-on-ceramic (81.7%) or ceramic-on-highly-crosslinked-polyethylene (18.3%) articulations. Results. At the time of this study, 28 patients (29 hips; 10.6%) had died and 40 (43 hips; 15.8%) were lost to follow-up. 17 patients (19 hips; 7.0%) could be reached only by telephone. There were four revisions in four patients (1.5%), all involving only the femoral component. Ten-year Kaplan-Meier survival with revision of any component for any reason as the endpoint was 98.4% (95% confidence interval: 96.9%–100%; 30 hips remained ‘at risk’). 170 unrevised patients (178 hips; 65.2%) were assessed clinically and radiographically at a median follow-up of 9.3 years (interquartile range (IQR): 8.8–9.8 years). The median Harris Hip Score (HHS) was 99.9 points (IQR: 97.7–100). The score did not differ significantly between the two articulations. There was no sign of radiographic loosening. Conclusions. The ten-year implant survival and the HHS score outcomes for THAs performed with the novel system were in line with those documented in the literature for its predecessor


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 61 - 61
1 Apr 2017
Gross A
Full Access

Acetabular cages are necessary when an uncemented or cemented cup cannot be stabilised at the correct anatomic level. Impaction grafting with mesh for containment of bone graft is an alternative for some cases in centers that specialise in this technique. At our center we use three types of cage constructs –. (A) Conventional cage ± structural or morselised bone grafting. This construct is used where there is no significant bleeding host bone. This construct is susceptible to cage fatigue and fracture. This reconstruction is used in young patients where restoration of bone stock is important. (B) Conventional cage in combination with a porous augment where contact with bleeding host bone can be with the ilium and then by the use of cement that construct can be unified. The augment provides contact with bleeding host bone and if and when ingrowth occurs, the stress is taken off the cage. (C) Cup Cage Construct – in this construct there must be enough bleeding host bone to stabilise the ultra-porous cup which functions like a structural allograft supporting and eventually taking the stress off the cage. This construct is ideal for pelvic discontinuity with the ultra-porous cup, i.e., bridging and to some degree distracting the discontinuity. If, however, the ultra-porous cup cannot be stabilised against some bleeding host bone, then a conventional stand-alone cage must be used. In our center the cup cage reconstruction is our most common technique where a cage is used, especially if there is a pelvic discontinuity. Acetabular bone loss and presence of pelvic discontinuity were assessed according to the Gross classification. Sixty-seven cup-cage procedures with an average follow-up of 74 months (range, 24–135 months; SD, 34.3) months were identified; 26 of 67 (39%) were Gross Type IV and 41 of 67 (61%) were Gross Type V (pelvic discontinuity). Failure was defined as revision surgery for any cause, including infection. The 5-year Kaplan-Meier survival rate with revision for any cause representing failure was 93% (95% confidence interval, 83.1–97.4), and the 10-year survival rate was 85% (95% CI, 67.2–93.8). The Merle d'Aubigné-Postel score improved significantly from a mean of 6 pre-operatively to 13 post-operatively (p < 0.001). Four cup-cage constructs had non-progressive radiological migration of the ischial flange and they remain stable


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 118 - 118
1 May 2016
Donaldson T Burgett-Moreno M Clarke I
Full Access

The purpose of this study was to determine the survivorship for a MOM implant series performed by a single community surgeon followed using a practical clinical model. A retrospective cohort of 104 primary MOM THA procedures (94 patients) were all performed by one surgeon at three local hospitals now with 10–13 years follow-up. Sixteen patients are deceased and 16 patients have been lost to follow-up. In the remaining 62 patients, 8 are bilateral providing a total of 70 THA for study. The clinical follow-up model included: hip scores, X-rays, ultrasound, and metal ion concentrations (Co, Cr, Ti). Due to the diversity of patient location, a variety of clinical labs were utilized for metal ions. Statistical methods included Kaplan-Meier survival curve and One-way ANOVA. Hip scores were available for 70 THA and of these 61 had a hip score (HHS) above 80 (87%). X-rays were available for 49 hips and of these 38 (78%) had lateral/version angles in the safe zone (Fig 1: inclination ≤ 55 and anteversion ≤ 35). Thirty-eight ultrasound exams were performed and of these three yielded fluid collections (8%). Metal ion concentrations were documented in 39 of 62 patients (63%, either serum or whole blood). Six outliers were identified with high concentrations of metal ions (Fig 2); Co 0.3–143.9 ppb (median 3.6), Cr 0.2–200.3 ppb (median 2.2) and Ti 2-110 ppb (median 54). Six patients were revised by the original surgeon. Three of six with elevated ions were documented as wear problems and the other three were revised for infection, femur fracture and metal-ion sensitivity. The survivorship of 92.5% at 10 years (Fig. 3) may be partly due to the exclusive use of antero-lateral approach performed by one surgeon with 78% of cups well placed and the MOM design used exclusively


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 47 - 47
1 Mar 2021
Martin K Persson A Moatshe G Fenstad A Engebretsen L Visnes H
Full Access

Surgery performed in low-volume centres has been associated with longer operating time, longer hospital stays, lower functional outcomes, and higher rates of revision surgery, complications, and mortality. This has been reported consistently in the arthroplasty literature, but there is a paucity of data regarding the relationship between surgical volume and outcome following anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to compare the ACL reconstruction failure rate between hospitals performing different annual surgical volumes. The hypothesis was that ACL reconstructions performed at low-volume hospitals would be associated with higher failure rates than those performed at high-volume centres. This level-II cohort study included all patients from the Norwegian Knee Ligament Registry that underwent isolated primary autograft ACL reconstruction between 2004 and 2016. Hospital volume was divided into quintiles based on the number of ACL reconstructions performed annually, defined arbitrarily as: 1–12 (V1), 13–24 (V2), 25–49 (V3), 50–99 (V4), and ≥100 (V5) annual procedures. Kaplan-Meier estimated survival curves and survival percentages were calculated with revision ACL reconstruction as the end point. Mean change in Knee Injury and Osteoarthritis Outcome Score (KOOS) Quality of Life and Sport subsections from pre-operative to two-year follow-up were compared using t-test. 19,204 patients met the inclusion criteria and 1,103 (5.7%) underwent subsequent revision ACL reconstruction over the study period. Patients in the lower volume categories (V1-3) were more often male (58–59% vs. 54–55% p=<0.001) and older (27 years vs. 24–25 years, p=<0.001) compared to the higher volume hospitals (V4-5). Concomitant meniscal injuries (52% vs. 40%) and participation in pivoting sports (63% vs. 56%) were most common in V5 compared with V1 (p=<0.001). Median operative time decreased as hospital volume increased, ranging from 90 minutes at V1 hospitals to 56 minutes at V5 hospitals (p=<0.005). Complications occurred at a rate of 3.8% at low-volume (V1) hospitals versus 1.9% at high-volume (V5) hospitals (p=<0.001). Unadjusted 10-year survival with 95% confidence intervals for each hospital volume category were: V1 – 95.1% (93.7–96.5%), V2 – 94.1% (93.1–95.1%), V3 – 94.2% (93.6–94.8%), V4 – 92.6% (91.8–93.4%), and V5 – 91.9% (90.9–92.9%). There was no difference in improvement between pre-operative and two-year follow-up KOOS scores between hospital volume categories. Patients having ACL reconstruction at lower volume hospitals did not have inferior clinical or patient reported outcomes, and actually demonstrated a lower revision rate. Complications occurred more frequently however, and operative duration was longer. The decreased revision rate is an interesting finding that may be partly explained by the fact that patients being treated in these small, often rural hospitals, may be of lower demand as suggested by the increased age and decreased participation in pivoting sports. In addition, patients with more complicated pathology such as meniscal tears were more commonly treated in the larger volume hospitals. The most significant limitation of this study is that provider volume was not assessed, and the number of surgeons dividing up the surgical volume at each hospital is not known


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 104 - 104
1 May 2016
De Almeida S Chong M Board T Turaev A
Full Access

Background. KAR™ prosthesis was introduced following the success of Corail® femoral stem to tackle difficult revision cases (Paprosky type1, 2a, 2b and 3a). The ARTO group reported a success rate of 94% at 17 years follow-up. Only two independent studies reported similar success rate to date. Purpose. To analyse the short-term performance of the KAR™ prosthesis used in our unit. Methods. This was a retrospective study of all KAR™ prosthesis between 2005 and 2013. Basic demographic, stem size, indications, failures and complications were recorded. X-rays were analysed for evidence of implant failure and distal cortical hypertrophy. Results. A total of 83 cases were analysed. The mean age was 68 (range 38–88 years) with an average follow-up was 3 years (range 1–8 years). The main indications for revision were aseptic loosening (83.7%), and periprosthetic fractures (7%). Kaplan-Meier Survival Rate for ‘all reasons of failure’ and ‘stem loosening’ was 93.83% and 100% respectively at 3 years follow-up. The most common reason for failure following KAR™ revision was periprosthetic fracture (3 cases). All three cases had radiographic evidence of proximal bone loss prior to index revision. Two patients developed deep infection and one patient had stem subsidence requiring revision. One patient sustained dislocation but revision surgery was not required. When comparing the effect of cortical hypertrophy, there were no significant differences in the measured distal canal/cortical diameter over the entire period of follow-up. Discussion. KAR™ prosthesis offers respectable clinical performance over a short-term period. Revision rate for this system was comparable to other ‘independent non-designer’ study. The three patients that sustained periprosthetic fracture may have been better served with a distally locked stem revision system. We believe that this HA coated implant encourages consistent osseointegration around the metaphysis region when there is evidence of a sound distal fixation. Conclusion. This study confirms that this fully coated hydroxyapatite titanium stem offers reliable clinical performance in revision arthroplasty


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 81 - 81
1 Dec 2015
Born P Ilchmann T Zwicky L Graber P Ochsner P Zimmerli W Clauss M
Full Access

To report mid-term results of PJI treated with uncemented stems. : 80 hips of PJI after THA were treated with uncemented stems from 01/1993 to 12/2012 and followed prospectively. Selection occurred for one- (n=27) or two-stage (n=53) exchange according to the Liestal algorithm. Surgical approaches were transfemoral (n=58), transgluteal (n=9) or transtrochanteric (n=13). A monoblock (Wagner SL, n=58) or modular (Revitan, n=22) revision stem was implanted. On the acetabular side 44 Müller rings, 33 Burch-Schneider cages (combined with a cemented PE-cup) and 3 press-fit cups were used. Kaplan-Meier survival was calculated for endpoints (a) persistence of infection, (b) septic/aseptic stem loosening. Radiographs were analysed for (a) subsidence, (b) distal stem integration, (c) changes in cortical thickness, (d) proximal femur restoration, (e) radiolucency around stem/cup. Mean FU was 5.2 (2–15) years. PJI was eradicated in 77 of 80 hips (96%). 3 patients (all two-stage) had a treatment failure. 2 were treated successfully with an additional two-stage exchange. In the 3rd patient we were not able to control infection and exarticulation was performed. Furthermore, one stem was revised for aseptic loosening (5 years), 1 for a broken Wagner stem (7 years) and 1 for subsidence (8 months). Stem survival after 5 years was 93% (SD ±2.5 years). 2 cups were revised for aseptic loosening and 1 for recurrent dislocations. Subsidence ≥5mm was found in 6 hips and occurred always within 3 months after surgery independent of stem type (p=0.947) and approach (p=0.691). Proximal femoral remodelling after transfemoral approach was excellent or good in 71% (32 excellent, 9 good) with no difference between one-/two-stage exchanges (p=0.288). Initial distal stem integration was 65mm medial and 66mm lateral and increased to 8mm medial (p=0.716) and 10mm lateral (p<0.001). Cortical thickness was unchanged over the entire FU period (p=0.493). Radiolucencies were seen around 26 stems, only the stem revised after 5years was rated loose. Eradication of PJI was high using our established protocol even with uncemented revision stems. Mid-term survival was independent from one-/two-stage revision and comparable to results for aseptic loosening revision