Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 9 - 9
1 Mar 2020
Gannon M Downie S Aggarwal I Parcell B Davies P
Full Access

Gram staining is used as an initial indicator of synovial joint infection but has widely varied false negative rates in the literature. Clinical decisions are often made on the basis of gram stain results, such as whether a patient requires urgent surgery, and therefore it is important to understand the tests efficacy. A retrospective review of synovial fluid aspirates in NHS Tayside for the years 2017 and 2018 was performed from the departmental microbiology database. Aspirates of large joints were included (hip, knee, shoulder, wrist, elbow, ankle). Any joints with prosthesis were excluded, including fixation metalwork. Any abscess overlying a joint that was not proven to penetrate the joint was also excluded. Initial gram stain results and formal culture results were reviewed. Final culture results were considered to be the gold standard to compare gram stain results to. 2167 samples were reviewed. Of these 1552 were excluded base on inclusion criteria. Of the remaining 615, 120 (19.5%) were culture positive. There were 33 positive gram stain results, 1 false positive and 32 true positive results. The sensitivity was 26.67% with a specificity of 99.80% (p=0.0001). The negative predictive value is 84.88% (CI 83.44% – 86.21%). These results show that gram stain tests of native joints have a low sensitivity and poor negative predictive value. This is reflected in the current literature with prosthetic joints. Based on this study caution should be used when interpreting a negative gram stain result with appropriate safety netting and follow up required alongside clinical assessment


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 310 - 310
1 Sep 2012
Savadkoohi D Siavashi B Rezanezhad SS Seifi M Savadkoohi M
Full Access

Aim. To analyse our results after en-block resection of aggressive GCT during 20 years period. Methods. We review 86 patients with skeletal GCT during the last 20 years, from 1990 until 2009, retrospectively. In the cases of latent and active type, extended curettage and bone graft or cement were our treatment of choice, while in aggressive ones we performed en block resection and reconstruction by fibular autograft (e.g. in distal part of radius) or fusion/hinge joint prosthesis (e.g. in GCT around the knee joint). We describe the recurrences, metastases and complications according to treatment. Results. There was no recurrence in 18 cases of en block resection and segmental bone defects were reconstructed with fibular autograft (5), joint fusion (4) and hinge joint arthroplasty (9). We had 2 cases of pulmonary metastasis that underwent resection of the metastasis. In one case, internal fixation failed and the graft broke; thus revision was performed. The rest 68 cases underwent extended curettage and bone graft (51) or cement (17). We had 7 cases of recurrence, 6 treated with repeated curettage and bone cement and one with en lock resection. No death or major complication was reported. Conclusions. In comparison of en block resection with extended curretage, the recurrence rate is greater with the latter; however it results in good control of the disease with less morbidity. In recent years, the invention of hinge knee prosthesis has increased the quality of patients' life in whom we could not preserve the involved joint


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 527 - 527
1 Sep 2012
Borgwardt A Borgwardt L Ribel Madsen S Borgwardt L Zerahn B Borgwardt A
Full Access

In a randomized study of 60 patients allergic reactions are evaluated in three joint prosthesis groups, a resurfacing arthroplasty (ReCap), a non-cemented, large metal-on-metal head (Bimetric Magnum) and a non-cemented, alumina ceramic-on-ceramic bearing in a titanium shell (Bimetric C2a). The inclusion criteria were osteoarthritis, ASA I–II, MRI-scan without caput necrosis, DXA-scan without osteoporosis. The exclusion criteria were short neck (<2cm.), large cysts (>1cm.), medical treatment affecting the bone metabolism, severe deformity of the femoral head, impaired kidney function and inability to co-operate. Blood samples were drawn prior to and 6 weeks, 6 months, 1 year, and 3 years after surgery; two tubes from which plasma was prepared, and two tubes for serum. From the last included 20 patients in each group was also taken blood one and three years after surgery for an in vitro lymphocyte assay for scoring of possible hypersensitivity to prosthesis metals. The isolated lymphocytes were subjected to measurement of proliferation and expression of CD69 by flow cytometry and measurement of the Migration Inhibitory Factor (MIF) by ELISA. Plasma concentrations of the cytokines IL-1, IL-4, IL-6, IL-8, IL-12p70, IL-15, interferon-and osteoprotegerin were determined by multiplex-immunoassay. Serum concentrations of chromium and cobalt were determined by graphite furnace atomic absorption spectrometry. The serum concentrations of chromium and cobalt were lowest in patients with the C2a implant and highest with Magnum, some of these differences were significant at 6 weeks, 6 months, and 1 year after surgery. No patient had a very high serum metal concentration. The values of the variables measured in the in vitro lymphocyte assay mainly changed in the expected direction depending on the concentration of the same metal in the serum sample drawn at the same time, but no significant correlation was seen. One patient had uncertain symptoms of metal hypersensitivity and relatively high serum metal concentrations 3 years after arthroplasty with a Magnum prosthesis and was assessed extraordinarily, and elicited the marginally highest MIF responses in the lymphocyte assay. A strong correlation was found between the plasma concentrations of most cytokines, but the cytokine concentrations were not correlated to contemporary metal concentrations


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 467 - 467
1 Sep 2012
Ding M Overgaard S
Full Access

Introduction. Osteoporosis (OP), osteoarthrosis (OA), and rheumatoid arthritis (RA) are the most common age-related degenerative bone diseases, and major public health problems in terms of enormous amount of economic cost. RA is considered as a major cause of secondary osteoporosis. At late stage, OP often leads to skeletal fractures, and OA and RA result in severe joint disability. Over the last a few decades, much significant research on the properties has been carried out on these diseases, however, a detailed comparison of the microarchitecture of cancellous bones of these diseases is not available. In this study, we investigated three-dimensional (3-D) microarchitectural properties of OP, OA and RA cancellous bone. We hypothesized that there were significant differences in microarchitecture among OP, OA and RA bone tissues that might lead to different bone quality. Materials and Method. Twenty OP, fifty OA, and twelve RA femur heads were harvested from patients undergone total hip replacement surgery. Cubic cancellous bone samples (8∗8∗8 mm3) were prepared and scanned with a high resolution microtomographic system (vivaCT 40, Scanco Medical AG., Brüttisellen, Switzerland). Then micro-CT images were segmented using individual thresholds to obtain accurate 3-D data sets. Detailed microarchitectural properties were evaluated based on novel unbiased, model-free 3-D methods. For statistical analysis, one-way ANOVA was used, and a p<0.05 was considered significant. Results. Significant differences in the microarchitecture of cancellous bone were observed among the OP, OA and RA groups. Compared with the other groups, OP cancellous bone had lowest density, thinner, typical rod-like structure and less connectivity (all p<0.01). Interestingly, there were no significant differences in the microarchitectural properties measured between the OA and RA cancellous bones. Both OA and RA cancellous bones had significant higher bone volume fraction and were thicker, typical plate-like structure compared with the OP group (all p<0.01), even though there was clearly bone erosion observed in RA cancellous bone. Discussion. Quantification of the alterations in bone properties and quality will help to gain more insights into the pathogenesis of degenerative bone diseases and to target and develop novel approaches for the intervention and treatment, and for the design, fixation and durability of total joint prosthesis. Our study demonstrated that there were significant differences in the microarchitecture of the OP, OA and RA femur head cancellous bone. The OA and RA cancellous bone had similar bone density and microarchitecture despite apparent bone erosion in the RA cancellous bone. These results from femur head did not support the traditional notion that RA and OP had similar low bone density. Thus, whether femur head bone tissues from these diseases have similar bone collagen, mineral and mechanical properties, more importantly bone quality, should be clarified in the future


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1262 - 1269
1 Sep 2016
Pinder EM Bottle A Aylin P Loeffler MD

Aims

To determine whether there is any difference in infection rate at 90 days between trauma operations performed in laminar flow and plenum ventilation, and whether infection risk is altered following the installation of laminar flow (LF).

Patients and Methods

We assessed the impact of plenum ventilation (PV) and LF on the rate of infection for patients undergoing orthopaedic trauma operations. All NHS hospitals in England with a trauma theatre(s) were contacted to identify the ventilation system which was used between April 2008 and March 2013 in the following categories: always LF, never LF, installed LF during study period (subdivided: before, during and after installation) and unknown. For each operation, age, gender, comorbidity, socio-economic deprivation, number of previous trauma operations and surgical site infection within 90 days (SSI90) were extracted from England’s national hospital administrative Hospital Episode Statistics database. Crude and adjusted odds ratios (OR) were used to compare ventilation groups using hierarchical logistic regression. Subanalysis was performed for hip hemiarthroplasties.