Wallace AL Walsh WR van Rooijen M Hughes JS Sonnabend DH

In severe forearm injuries, the diagnosis of disruption of the interosseous membrane is frequently delayed and sometimes missed, giving difficulties in the salvage of forearm stability. We studied the structure and function of the interosseous membrane in 11 cadaver preparations, using mechanical and histological analysis. Seven of the specimens tested in uniaxial tension sustained a mid-substance tear of the central band of the membrane at a mean peak load of 1038 ± 308 N. The axial stiffness was 190 ± 44 N/mm with elongation to failure of 10.34 ± 2.46 mm. These results provide criteria for the evaluation of reconstructive methods. A preliminary clinical investigation of the use of ultrasound suggests that this may be of value in the screening of patients with complex fractures of the forearm, and for investigating the natural history of tears of the interosseous membrane


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 522 - 529
1 Apr 2009
Ryzewicz M Morgan SJ Linford E Thwing JI de Resende GVP Smith WR

Nonunion of the tibia associated with bone loss, previous infection, obliteration of the intramedullary canal or located in the distal metaphysis poses a challenge to the surgeon and significant morbidity to patients. We retrospectively reviewed the records of 24 patients who were treated by central bone grafting and compared them to those of 20 who were treated with a traditional posterolateral graft. Central bone grafting entails a lateral approach, anterior to the fibula and interosseous membrane which is used to create a central space filled with cancellous iliac crest autograft. Upon consolidation, a tibiofibular synostosis is formed that is strong enough for weight-bearing. This procedure has advantages over other methods of treatment for selected nonunions. Of the 24 patients with central bone grafting, 23 went on to radiographic and clinical union without further intervention. All healed within a mean of 20 weeks (10 to 48). No further bone grafts were required, and few complications were encountered. These results were comparable to those of the 20 patients who underwent posterolateral bone grafting who united at a mean of 31.3 weeks (16 to 60) but one of whom required below-knee amputation for intractable sepsis. Central bone grafting is a safe and effective treatment for difficult nonunions of the tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1629 - 1633
1 Dec 2006
Jungbluth P Frangen TM Arens S Muhr G Kälicke T

The Essex-Lopresti injury is rare. It consists of fracture of the head of the radius, rupture of the interosseous membrane and disruption of the distal radioulnar joint. The injury is often missed because attention is directed towards the fracture of the head of the radius. We present a series of 12 patients with a mean age of 44.9 years (26 to 54), 11 of whom were treated surgically at a mean of 4.6 months (1 to 16) after injury and the other after 18 years. They were followed up for a mean of 29.2 months (2 to 69). Ten patients had additional injuries to the forearm or wrist, which made diagnosis more difficult. Replacement of the head of the radius was carried out in ten patients and the Sauve-Kapandji procedure in three. Patients were assessed using standard outcome scores. The mean post-operative Disabilities of the Arm, Shoulder and Hand score was 55 (37 to 83), the mean Morrey Elbow Performance score was 72.2 (39 to 92) and the mean Mayo wrist score was 61.3 (35 to 80). The mean grip strength was 68.5% (39.6% to 91.3%) of the unaffected wrist. Most of the patients (10 of 12) were satisfied with their operation and in 11 the pain was relieved. When treating the chronic Essex-Lopresti injury, we recommend accurate realignment of the radius and ulna and replacement of the head of the radius. If this fails a Sauve-Kapandji procedure to arthrodese the distal radioulnar joint should be undertaken to stabilise the forearm while maintaining mobility


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1385 - 1391
1 Oct 2014
Grassmann JP Hakimi M Gehrmann SV Betsch M Kröpil P Wild M Windolf J Jungbluth P

The Essex-Lopresti injury (ELI) of the forearm is a rare and serious condition which is often overlooked, leading to a poor outcome. . The purpose of this retrospective case study was to establish whether early surgery can give good medium-term results. . From a group of 295 patients with a fracture of the radial head, 12 patients were diagnosed with ELI on MRI which confirmed injury to the interosseous membrane (IOM) and ligament (IOL). They were treated by reduction and temporary Kirschner (K)-wire stabilisation of the distal radioulnar joint (DRUJ). In addition, eight patients had a radial head replacement, and two a radial head reconstruction. All patients were examined clinically and radiologically 59 months (25 to 90) after surgery when the mean Mayo Modified Wrist Score (MMWS) was 88.4 (78 to 94), the mean Mayo Elbow Performance Scores (MEPS) 86.7 (77 to 95) and the mean disabilities of arm, shoulder and hand (DASH) score 20.5 (16 to 31): all of these indicate a good outcome. In case of a high index of suspicion for ELI in patients with a radial head fracture, we recommend the following: confirmation of IOM and IOL injury with an early MRI scan; early surgery with reduction and temporary K-wire stabilisation of the DRUJ; preservation of the radial head if at all possible or replacement if not, and functional bracing in supination. This will increase the prospect of a good result, and avoid the complications of a missed diagnosis and the difficulties of late treatment. Cite this article: Bone Joint J 2014;96-B:1385–91


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 47 - 47
1 Sep 2012
Fontaine C Couturier-Bariatynski V Chantelot C Wavreille G
Full Access

Dynamometric measurement of the grasp strength is commonly used in wrist assessment. On the other hand measurement of the pronation-supination (PS) strength has been few studied. The longitudinal forearm rotation needs integrity of the two radioulnar joints and of the antebrachial interosseous membrane. The strength developed during PS assesses also trophicity of pronator and supinator muscles. A PS dynamometer (Baseline ®, AREX) is now available for such measurements. The aims of this study were: 1) to study the best way to neutralize the shoulder movements of abduction-adduction, 2) to find the values of PS Strength in a healthy population, and 3) to study correlations between this PS force and several biometric items. A first series of measurements des PS strength was performed thanks to the Baseline dynamometer in 8 people, in association with two devices neutralizing the shoulder movements of abduction-adduction, in repeated campaigns allowed the authors to determine and keep the better one for optimal measurements following campaigns. To assess the normal values of PS Strength in a healthy population, 38 healthy volunteers from both genders and different ages, classified according their age class, from three different forearm position: neutral, from 90 ° of supination and 90 ° of pronation. Finally, statistical analysis looked for correlations between PS strength and some biometric data. Manipulations beginning from a neutral position of forearm were the most reliable. The mean strength within the whole studied sample (76 wrists, 17 male, 21 female) was 10.6 N.m (standard deviation SD 3.26) for the supination and 13.9 N.m (standard deviation 4.19) for the supination. The dominant side exhibited a PS strength superior by 7.5% to that of the non-dominant side. Male gender, the height and weight of the body, forearm circumference displayed positive relationships with PS strength. Mean values of PS strength, measured from a neutral forearm rotation and with the best device to neutralize the shoulder movements, in a healthy population of 38 volunteers, allowed the authors establishing reference values. They will allow precise comparisons between the values found in patients suffering from forearm and/or wrist pathology and the healthy population, taking into account the age, gender and hand dominance


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 645 - 648
1 May 2006
Jepegnanam TS

Four men who presented with chronic dislocation of the radial head and nonunion or malunion of the ulna were reviewed after open reduction of the radial head and internal fixation of the ulna in attempted overcorrection. Their mean age was 37 years (28 to 46) and the mean interval between injury and reconstruction was nine months (4 to 18).

The mean follow-up was 24 months (15 to 36). One patient who had undergone secondary excision of the radial head was also followed up for comparison.

The three patients who had followed the treatment protocol had nearly normal flexion, extension and supination and only very occasional pain. All had considerable loss of pronation which did not affect patient satisfaction.

Preservation of the radial head in chronic adult Monteggia fractures appears to be a promising mode of treatment.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 385 - 389
1 Mar 2014
Attal R Maestri V Doshi HK Onder U Smekal V Blauth M Schmoelz W

Using human cadaver specimens, we investigated the role of supplementary fibular plating in the treatment of distal tibial fractures using an intramedullary nail. Fibular plating is thought to improve stability in these situations, but has been reported to have increased soft-tissue complications and to impair union of the fracture. We proposed that multidirectional locking screws provide adequate stability, making additional fibular plating unnecessary. A distal tibiofibular osteotomy model performed on matched fresh-frozen lower limb specimens was stabilised with reamed nails using conventional biplanar distal locking (CDL) or multidirectional distal locking (MDL) options with and without fibular plating. Rotational stiffness was assessed under a constant axial force of 150 N and a superimposed torque of ± 5 Nm. Total movement, and neutral zone and fracture gap movement were analysed.

In the CDL group, fibular plating improved stiffness at the tibial fracture site, albeit to a small degree (p = 0.013). In the MDL group additional fibular plating did not increase the stiffness. The MDL nail without fibular plating was significantly more stable than the CDL nail with an additional fibular plate (p = 0.008).

These findings suggest that additional fibular plating does not improve stability if a multidirectional distal locking intramedullary nail is used, and is therefore unnecessary if not needed to aid reduction.

Cite this article: Bone Joint J 2014;96-B:385–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 354 - 360
1 Mar 2007
Konrad GG Kundel K Kreuz PC Oberst M Sudkamp NP

The objective of this retrospective study was to correlate the Bado and Jupiter classifications with long-term results after operative treatment of Monteggia fractures in adults and to determine prognostic factors for functional outcome. Of 63 adult patients who sustained a Monteggia fracture in a ten-year period, 47 were available for follow-up after a mean time of 8.4 years (5 to 14). According to the Broberg and Morrey elbow scale, 22 patients (47%) had excellent, 12 (26%) good, nine (19%) fair and four (8%) poor results at the last follow-up. A total of 12 patients (26%) needed a second operation within 12 months of the initial operation. The mean Broberg and Morrey score was 87.2 (45 to 100) and the mean DASH score was 17.4 (0 to 70). There was a significant correlation between the two scores (p = 0.01). The following factors were found to be correlated with a poor clinical outcome: Bado type II fracture, Jupiter type IIa fracture, fracture of the radial head, coronoid fracture, and complications requiring further surgery.

Bado type II Monteggia fractures, and within this group, Jupiter type IIa fractures, are frequently associated with fractures of the radial head and the coronoid process, and should be considered as negative prognostic factors for functional long-term outcome. Patients with these types of fracture should be informed about the potential risk of functional deficits and the possible need for further surgery.