Bone & Joint Research
Vol. 7, Issue 2 | Pages 187 - 195
1 Feb 2018
Ziebart J Fan S Schulze C Kämmerer PW Bader R Jonitz-Heincke A

Objectives. Enhanced micromotions between the implant and surrounding bone can impair osseointegration, resulting in fibrous encapsulation and aseptic loosening of the implant. Since the effect of micromotions on human bone cells is sparsely investigated, an in vitro system, which allows application of micromotions on bone cells and subsequent investigation of bone cell activity, was developed. Methods. Micromotions ranging from 25 µm to 100 µm were applied as sine or triangle signal with 1 Hz frequency to human osteoblasts seeded on collagen scaffolds. Micromotions were applied for six hours per day over three days. During the micromotions, a static pressure of 527 Pa was exerted on the cells by Ti6Al4V cylinders. Osteoblasts loaded with Ti6Al4V cylinders and unloaded osteoblasts without micromotions served as controls. Subsequently, cell viability, expression of the osteogenic markers collagen type I, alkaline phosphatase, and osteocalcin, as well as gene expression of osteoprotegerin, receptor activator of NF-κB ligand, matrix metalloproteinase-1, and tissue inhibitor of metalloproteinase-1, were investigated. Results. Live and dead cell numbers were higher after 25 µm sine and 50 µm triangle micromotions compared with loaded controls. Collagen type I synthesis was downregulated in respective samples. The metabolic activity and osteocalcin expression level were higher in samples treated with 25 µm micromotions compared with the loaded controls. Furthermore, static loading and micromotions decreased the osteoprotegerin/receptor activator of NF-κB ligand ratio. Conclusion. Our system enables investigation of the behaviour of bone cells at the bone-implant interface under shear stress induced by micromotions. We could demonstrate that micromotions applied under static pressure conditions have a significant impact on the activity of osteoblasts seeded on collagen scaffolds. In future studies, higher mechanical stress will be applied and different implant surface structures will be considered. Cite this article: J. Ziebart, S. Fan, C. Schulze, P. W. Kämmerer, R. Bader, A. Jonitz-Heincke. Effects of interfacial micromotions on vitality and differentiation of human osteoblasts. Bone Joint Res 2018;7:187–195. DOI: 10.1302/2046-3758.72.BJR-2017-0228.R1


Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims

Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.

Methods

This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 3 - 3
1 Feb 2021
Hwang E Braly H Ismaily S Noble P
Full Access

INTRODUCTION. The increasing incidence of periprosthetic femoral fractures (PFF) after total hip arthroplasty presents growing concerns due to challenges in treatment and increased mortality. PFF are often observed when the prosthesis is implanted in varus, especially with blade-type stems. To help elucidate its impact on the PFF risk, the specific research question is: What is the effect of misalignment of a blade-type stem (resulting in down-sized prosthesis) on 1)the distribution and magnitude of cortical stresses and 2)implant-bone micromotion. METHOD. We developed two finite element models consisting of an average female femur implanted within a generic blade-type stem prosthesis, (i)in neutral alignment, and (ii)oriented in 5° of varus, coupled with corresponding down-sizing of the prosthesis. Each model consisted of 1.1million elements, while the average mesh length at the implant-bone interface was 0.4mm. Elastic moduli of 15GPa(cortex), 150MPa(trabecular bone), and 121GPa(implant), and Poisson's ratio of 0.3 were assumed. The distal end was fixed and the interface was defined as a surface-to-surface contact with friction coefficients (dynamic 0.3; static 0.4). Walking and stair-climbing were simulated by loading the joint contact and muscle forces after scaling to the subjects’ body weight. The peak von Mises stress and the average stress within the surface having 1cm diameter and the center at where the peak stress occurred at each contacting area, the interfacial micromotion along medial, lateral side were analyzed. For statistical analysis, two-tailed t-test was performed between the neutral and varus cases over four loading cycles with significance level of p<0.05. RESULTS. Neutral alignment led to three areas of cortical/implant contact with focal load transfer via those areas, whereas varus placement limited to two areas (Figure 1). In both simulations, the greatest stress was observed at the proximal medial contact. With varus, average and peak stresses increased by 39% and 65% during walking and 28% and 35% during stair-climbing, respectively (Table 1). Micromotion was greatest over the proximal third of the interface, especially along lateral side (Figure 2). The 90. th. percentile values with the varus exceeded the neutral by 35% with walking and 28% with stair-climbing over the lateral interface. DISCUSSION. The proximal medial location of the greatest stress correlates well with clinical observations in PFF involving a posteromedial calcar fragment. Based on current lesser stress than the reported yield stress, loading during daily living activities may result in microdamage rather than an immediate PFF. However, impact loading such as hammering for stem insertion may introduce PFF at the location, especially with in varus. The increase in interfacial micromotion is expected to lead to increase in the risk for implant loosening, also leading to PFF. Further study is needed to confirm the validity and generalizability of these findings. SIGNIFICANCE/CLINICAL RELEVANCE. This study demonstrates the importance of proper alignment of femoral stems of a blade-type design. The misalignment (resulting in down-sizing) increased stress up to 65% and micromotion up to 35% around prosthesis, even during daily activities, thus increased attention to proper implant alignment and sizing is suggested when using components of this design. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 135 - 135
1 Jan 2016
Reimeringer M Nuno N
Full Access

Introduction. Typical failure of cementless total hip arthroplasty is the lack of initial stability. Indeed, presence of motion at the bone implant-interface leads to formation of fibrous tissue that prevents bone ingrowth, which in turn may lead to loosening of the implant. It has been shown that interfacial micromotion around 40 produces partial ingrowth, while micromotion exceeding 150 completely inhibits bone ingrowth. Finite element analyses (FEA) are widely used to evaluate the initial stability of cementless THA in pre-clinical validation. Untill now, most FE models developed to predict initial stability of cementless implants were performed based on static load, by selecting the greatest load at a particular time of the cycle activity, but in fact the hip is exposed to varied load during the activity. The aim of this study is to investigate the difference in the predicted micromotion induced by static, quasi-static and dynamic loading conditions. Materials & Methods. Finite element analysis (FEA) was performed on a Profemur®TL implanted into a composite bone. The implant orientation was validated in a previous study [3]. All materials were defined as linear isotropic homogeneous. Static and dynamic FEA was performed for the loading conditions defined by simulating stair-climbing. In the static analysis, the applied resultant force (calculated with a body weight of 836N) were 951N and 2107N to simulate the abductor muscle and the hip joint contact forces, respectively [4]. In the dynamic analysis, the applied resultant force can be seen on Fig. 1. The initial stability was extracted on 54 points (Fig. 2) located on the plasma spray surface by calculating the difference between the final displacement of the prosthesis and the final displacement of the composite bone. Results. The mean micromotion predicted with the static loading conditions is 32μm with a maximum of 76μm whereas the maximum micromotion predicted with dynamic loading conditions is 36μm with a maximum of 86μm. Micromotion predicted with dynamic load greater than the micromotion predicted with static load on 35 out of 54 points. In the superior portion of the prosthesis, micromotion predicted with static loading condition is greater on medial posterior and in lateral anterior faces. In the inferior portion, the micromotion. Discussion. Micromotion predicted by the dynamic loading condition is greater than that predicted with static loading condition. Moreover, 22 points are in the range of 50–150μm (range for partial osseointegration) with dynamic condition, whereas only 16 points are in this range with static condition. On the posterior inferior face, all points are in this range with the dynamic condition, whereas only 2 with static condition. However micromotion predicted at all points either by static or dynamic conditions are lower than 150μm, the threshold value with regard to osseointegration


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 43 - 43
1 May 2016
Bischoff J Wernle J Marra G Verborgt O
Full Access

Introduction. Good outcomes in reverse shoulder arthroplasty (RSA) rely in part on stability of the humeral component. Traditionally humeral components have been cemented, however there has been recent interest in press-fit fixation of humeral components in RSA. Lateralization of the head center in RSA can impart larger moments on the humeral component than for anatomic reconstructions, increasing the importance of distal humeral canal preparation for implant stability. To date, the primary stability of any type of press-fit humeral prosthesis has been largely unexplored. The goal of this study is to evaluate the effect of over-reaming the distal humeral canal in a press-fit humeral component in RSA. Methods. Computed tomography (CT) data of the shoulder were obtained from 55 shoulders. Images were segmented to produce digital models of the humerus. Humeral components for RSA (2mm diameter size increments) were sized and placed per the surgical technique, including preparation of the humerus with the appropriate reamers (1mm increments). Finite element models for each specimen were created with heterogeneous bone properties derived from the CT scan. Pressfit between the bone and stem was resolved to quantify the initial contact pressure on the stem; each stem was then loaded at 566N oriented 20° lateral and 45° anterior. Overall motion of the stem was measured, as well as interfacial micromotion in the porous coating region (Fig. 1). The effect of line-to-line (L2L) reaming and over-reaming by 1 mm was evaluated using an unpaired Student's t-test, with significance defined at p<0.05. Results. Across all specimens, stem sizes 8 (n=3), 10 (n=25), 12 (n=20), 14 (n=2), and 16 (n=1) were used. Stem motion ranged from approximately 250–750μm; micromotion remained under 300μm (Fig. 2). Stem motion was significantly less for L2L reaming as compared to over-reaming for both size 10 (p=.008) and size 12 (p=.002) stems; micromotion was significantly less for size 12 (p=.002) stems. L2L reaming to a larger diameter stem resulted in significantly reduced stem motion (average 390μm versus 530μm, p<.001) and micromotion (average 53μm versus 135μm, p=.001) than over-reaming and using a smaller diameter stem. Stem rotation following L2L reaming was generally below 0.5°, and exceeded 0.75° when over-reaming. Discussion and Conclusion. Reaming of the humeral canal directly impacts the stability of humeral stems in RSA. Even with satisfactory proximal press-fit, over-reaming enables increased rotation of the stem under functional loading prior to cortical engagement, and results in increased micromotion. In cases in which the reamer and stem offerings result in over-reaming, L2L reaming to the next larger stem significantly reduces stem motion and micromotion. However, reaming up also removes distal cortical bone, and thus the strength of the prepared humerus must be considered. In conclusion, line-to-line reaming significantly reduces the micromotion of humeral stems as compared to over-reaming


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 155 - 155
1 Jan 2016
Ghosh R Paul S Rubel YSA Paul A Saha D
Full Access

Introduction. Long-term success of the cementless acetabular component has been depends on amount of bone ingrowth around porous coated surface of the implant, which is mainly depends on primary stability, i.e. amount of micromotion at the implant-bone interface. The accurate positioning of the uncemented acetabular component and amount of interference fit (press-fit) at the rim of the acetabulum are necessary to reduce the implant-bone micromotion and that can be enhancing the bone ingrowth around the uncemented acetabular component. However, the effect of implant orientations and amount of press-fit on implant-bone micromotion around uncemented acetabular component has been relatively under investigated. The aim of the study is to identify the effect of acetabular component orientation on implant-bone relative micromotion around cementless metallic acetabular component. Materials and Method. Three-dimensional finite element (FE) model of the intact and implanted pelvises were developed using CT-scan data [1]. Five implanted pelvises model, having fixed antiversion angle (25°) and different acetabular inclination angle (30°, 35°, 40°, 45° and 50°), were generated in order to understand the effect of implant orientation on implant-bone micromotion around uncemented metallic acetabular component. The CoCrMo alloy was chosen for the implant material, having 54 mm outer diameter and 48 mm bearing diameter [1]. Heterogeneous cancellous bone material properties were assigned using CT-scan data and power law relationship [1], whereas, the cortical bone was assumed homogeneous and isotropic [1]. In the implanted pelvises models, 1 mm diametric press-fit was simulated between the rim of the implant and surrounding bone. Six nodded surface-to-surface contact elements with coefficient of friction of 0.5 were assigned at the remaining portion of the implant–bone interface [1]. Twenty-one muscle forces and hip-joint forces corresponds to peak hip-joint force of a normal walking cycle (13%) were used for the applied loading condition. Fixed constrained was prescribed at the sacroiliac joint and pubis-symphysis [1]. A submodelling technique was implemented, in order to get more accurate result around implant-bone interface [1]. Results and Discussions. The peak implant-bone sliding interfacial micromotion was observed around 75 microns around superior and supero-posterior regions of the acetabulum, whereas, micromotion was below 50 microns around other regions (area). As compared to other regions, less implant-bone micromotions were observed at the central region of the acetabulum and anterior part of the acetabulum, where micromotions were varied in the range between 5 microns to 30 microns. Although, the generated peak implant-bone sliding micromotion around the uncemented acetabulum was not vary notably due to change in inclination angle of the acetabular component, changes in patterns of implant-bone micromotions were observed and as shown [Fig.1]. Results of the present study indicated that the positioning of the uncemented acetabular component have influence on patterns of implant-bone micromotion and that might have influence on bone ingrowth and long-term success of uncemented acetabular component


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 158 - 158
1 Dec 2013
Reimeringer M Nuño N
Full Access

Introduction. Modeling the press-fit that occurs in Total Hip Arthroplasty (THA) cementless implants is crucial for the prediction of micromotion using finite element analysis (FEA). Some studies investigated the effect of the press-fit magnitude and found a direct influence on the micromotion [1,2]. They assumed in their model that press-fit occurs throughout the prosthesis. However [3] found using computed tomography measurement that only 43% of the stem-bone interfaces is really in contact. The aim of this study is to investigate the press-fit effect at the stem-bone interface on the implant micromotion. Methods. Finite element analysis (FEA) was performed on a Profemur® TL implanted into a Sawbones®. The implant orientation was validated in a previous study [4]. All materials were defined as linear isotropic homogeneous. FEA was carried out for the static loading conditions defined by [5] simulating walking fastly. Frictional contact between the bone and the prosthesis was assumed all along the prosthesis with a coefficient μ set to 0, 63 for the plasma spray (Fig. 1a) and 0,39 for the polished surface (Fig. 1b) [6]. Firstly, FEA was performed without press-fit (Fig. 2a) and then press-fit was simulated with an interference of 0,05 mm [2] between stem and bone in specific areas: superior (Fig. 2b), intermediate (Fig. 2c), inferior (Fig. 2d), and cortical alone (Fig. 2e) and finally over the entire surface in contact with the bone. The press-fit effect at the stem-bone interface on the micromotion was investigated. Measurement of the micromotion was realised on different points located on the plasma spray surface by calculating the difference between the final displacement of the prosthesis and the final displacement of the bone. Results. When press-fit is applied along the entire stem-bone interface, micromotion is lower than 10 μm. In the case when no press fit is simulated, micromotion is in the range of 11 μm and 48 μm. When press-fit is included where only cortical bone is (small areas mid-way proximal and medial part), micromotion is in the range of 17 μm and 30 μm. When the press-fit is included where inferior cancellous bone is (more distal), micromotion is between 9 μm and 38 μm. When the press-fit is included in the intermediate cancellous bone (mid-way), micromotion is between 1 μm and 47 μm. Finally, when press-fit is involved in the superior cancellous bone (more proximal) alone, micromotion is in the range of 4 μm and 12 μm. The results are shown on Fig. 3. Discussion. The maximum stem-bone interface micromotions calculated in this study always remain lower than 50 μm. [7] shows that interfacial micromotion greater than 40 μm produces only partial ingrowth. This indicates that in our study, in all cases investigated the primary stability was not compromised. In general, press-fit increased the primary stability. Our results indicate that press-fit in the proximal area improves widely the primary stability of this prosthesis, especially if the implant is in direct contact with cortical and cancellous bone


Bone & Joint Research
Vol. 13, Issue 4 | Pages 193 - 200
23 Apr 2024
Reynolds A Doyle R Boughton O Cobb J Muirhead-Allwood S Jeffers J

Aims

Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.

Methods

Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.