Advertisement for orthosearch.org.uk
Results 1 - 20 of 22
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 39 - 39
1 Jul 2020
El-Bakoury A Parkar A Powell J
Full Access

Background. One of the potential complications of polyethylene liner (PL) is its dissociation from the metal shell. This is a rare but catastrophic complication of total hip replacement (THR). Objective. was to analyze the retrieved dissociated components (PL and shell) (Depuy Pinnacle, Warsaw, IN, USA) to evaluate the mechanism of failure. All these components were dissociated within four years of implantation. Methods. Components were retrieved from three different centers in Canada over the period from January 2011 to October 2016. The analysis was done at the Orthopaedic Innovation Centre (OIC) in Winnipeg Canada. Nine PLs were retrieved at the time of revision THR. Assessment using optical and scanning electron microscopies at magnification between 25× and 150× was performed. The following questions were asked: 1) were the liners correctly seated at the primary surgery? 2) Are there signs of impingement present which could have caused the liner to become dissociated? 3) Does the wear pattern indicate that the liner was failing prior to dissociation?. Results. All PLs dissociated in the inferior direction. Five PL were believed to have been seated properly at the time of indexed surgery. All PL displayed signs of post dissociation impingement. Only 1 PL had fractured resulting in failure prior to dissociation. Other PL showed signs of wear, however none of them reached thinness that would be a cause for concern. Eight PLs demonstrated shearing of the anti rotation tabs. Assessment of the anti rotation tabs revealed that a couple had sheared off suddenly while remaining anti rotation tabs sheared off in progressive fatigue resulting in the failure of the locking mechanism. Conclusions. Retrieval analysis was useful in identifying common patterns of failure such as anti-rotation tab damage. This was suggestive that the locking mechanism of the acetabular components has probably failed in 8 out of 9 of the retrieved liners


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 1 - 1
1 Oct 2020
Clohisy J Haddad FS
Full Access

The unparalleled events of the year 2020 continue to evolve and challenge the worldwide community on a daily basis. The COVID-19 pandemic has had a major impact on all aspects of our lives, and has caused major morbidity and mortality around the globe. The impact of COVID-19 on the practice of orthopedic surgery has been substantial with practice shutdowns, elective surgery restrictions, heightened utilization of telemedicine platforms and implementation of precautionary measures for in-person clinic visits. During this transition period the scholarly and educational pursuits of academic surgeons have been de-emphasized as the more immediate demands of clinical practice survivorship have been the priority. This unavoidable focus on clinical practice has heightened the importance of orthopedic subspecialty societies in maintaining an appropriate level of attention on research and educational activities. Under the outstanding presidential leadership of Robert Barrack, MD, The Hip Society adapted to the profound challenges of 2020, and maintained strong leadership in the realms of education and research. The recent 2020 summer meeting of the Hip Society was a testimonial to the resilience and dedication of the Society members to ongoing innovation in research and education. Due to travel and social distancing restrictions the 2020 summer meeting was transitioned from an in-person to a virtual meeting format. Dr Barrack and Program Chair Dr John Clohisy assisted with oversight of the meeting, while Olga Foley and Cynthia Garcia ensured the success of the meeting with remarkable planning and organization. These collaborative efforts resulted in an organized, well-attended, high level scientific meeting with engaging discussion and a remarkable virtual conference environment. The Bone & Joint Journal is very pleased to partner with The Hip Society to publish the proceedings of this very unique virtual meeting. The Hip Society is based in the United States and membership is granted to select individuals for leadership accomplishments in education and research related to hip disease. The Society is focused on the mission of advancing the knowledge and treatment of hip disorders to improve the lives of patients. The vision of the Hip Society is to lead in the discovery and dissemination of knowledge related to disorders of the hip. The annual closed meeting is one of the most important events of the society as this gathering highlights timely, controversial and novel research contributions from the membership. The top research papers from The Hip Society meeting will be published and made available to the wider orthopedic community in The Bone & Joint Journal. This partnership with The Bone & Joint Journal enhances the mission and vision of The Hip Society by international dissemination of the meeting proceedings. Given the far-reaching circulation of The Bone & Joint Journal the highest quality work is available to an expanding body of surgeons, associated healthcare providers and patients. Ultimately, this facilitates the overarching Hip Society goal of improving the lives of our patients. The 2020 virtual Hip Society meeting was characterized by outstanding member attendance, high quality paper presentations and robust discussion sessions. The meeting was held over two days and encompassed 58 open paper presentations divided into ten sessions with moderated discussions after each session. All papers will be presented in this issue in abstract form, while selected full papers passing our rigorous peer review process will be available online and in The Bone & Joint Journal in a dedicated supplement in 2021. The first session of the meeting focused on issues related to complex primary THA and osteonecrosis of the femoral head. Dr Gross presented on the conversion of hip fusion to THA in 28 patents at a mean 7 years. He reported a high clinical success rate, yet complications of heterotopic ossification and neurologic injury were relatively common. Consideration of heterotopic ossification prophylaxis and the selective use of a constrained liner were recommended. Dr Pagnano summarized the use of various contemporary porous acetabular components in 38 hips in the setting of prior pelvic radiation. The mean follow-up was 5 years and 10 year survivorship was 100% with all implants radiographically fixed. Dr Bolognesi's study demonstrated that THA in solid organ transplant patients is associated with higher risk for facility placement, transfusions and readmissions. This patient population also has increased mortality risk (4.3% risk at 1 year) especially lung transplant patients. The second group of papers focused on femoral head osteonecrosis. Dr Iorio presented single center data demonstrating that CT scan was a useful adjunct for diagnosis in the staging work-up for cancer, yet was not useful for ARCO staging and treatment decision-making. On the basic science side, Dr Goodman utilized a rabbit model of steroid-induced femoral head osteonecrosis to determine that immunomodulation with IL-4 has the potential to improve bone healing after core decompression. The session was concluded by Dr Nelson's study of ceramic-on-ceramic THA in 108 osteonecrosis patients. The median 12 year results were outstanding with marked increases in PROs, maintenance of high activity levels, and a 3.7% revision rate. In the second session attention was directed to THA instability and spinopelvic mobility. Dr Sierra presented a machine learning algorithm for THA dislocation risk. Two modifiable variables (anterior/lateral approach, elevated liner) were most influential in minimizing dislocation risk. Dr Taunton's study demonstrated a deep learning artificial intelligence model derived from postoperative radiographs to predict THA dislocation risk. High sensitivity and negative predictive value suggest that this model may be helpful in assessing postoperative dislocation risk. In reviewing a large single-center, multiple surgeon cohort of 2,831 DAA procedures, Dr Moskal noted a very low dislocation rate (0.45%) at minimum 2 years. Importantly, spinopelvic pathology or prior spinal instrumentation was not associated with an increased dislocation risk (0.30%). Dr Huo and colleagues analyzed pelvic tilt during functional gait in patients with acetabular dysplasia. They detected variable pelvic tilt on different surfaces with the data suggesting that patients with more anterior pelvic tilt while standing tend to have greater compensatory posterior pelvic tilt during gait. Dr Lamontagne reported on the sagittal and axial spinomobility in patients with hip OA, and highlighted reductions in pelvic tilt, pelvic-femoral-angle, lumbar lordosis and seated maximal trunk rotation when compared to controls. Dr Dennis showed that differences in spinopelvic mobility may explain the variable accuracy of acetabular version measurements on the cross-table lateral radiographs. Dr Gwo-Chin presented on a comprehensive functional analysis of 1,592 patients undergoing THA and observed that spinopelvic abnormalities are not infrequent (14%) in THA patients. Consistent with these findings Dr Murphy and collaborators identified a low prevalence of previous spinal instrumentation (1.5%), yet a high prevalence of spine stiffness (27.6%) in 149 patients undergoing THA. Session three highlighted various aspects of treating hip disease in young patients. Dr Peters investigated the need for subsequent hip arthroscopy in 272 patients treated with an isolated PAO. Only 4.8% of these patients required subsequent arthroscopy calling into question the routine use of combined arthroscopy and PAO. Three papers addressed questions related to THA in young patients. Dr Berend's study of 2532 hips demonstrated that high activity level was not associated with an increased risk of midterm aseptic or all cause failure. Dr Nunley presented on 43 young patients with an average age of 52 years treated with a cementless stem and modular dual mobility articulation. Stress shielding was minimal and no concerning metal ion release detected. Dr Garvin summarized minimum 15 year data of THA with highly cross-linked polyethylene in patient less than 50 years. These hips performed exceptionally well with no mechanical loosening or radiographic osteolysis. Dr Engh examined 10 year results of the Birmingham Hip Resurfacing implant and reported a 92.9 % overall survivorship, with males less than 55 years achieving a 98.3% survivorship. The session was concluded by long-term data on the Conserve Plus hip resurfacing arthroplasty. Dr Amstutz presented an impressive dataset depicting an 83.1% 20 year survivorship for this early resurfacing cohort. Direct anterior approach total hip arthroplasty was the focus of session four. Dr Meneghini reported on the anesthesia and surgical times of direct anterior and posterior approaches from a large healthcare system database. These data suggested longer OR and surgical times for the DAA both in the inpatient and ASC environments. Dr Clohisy introduced the technique and early outcomes of lateral decubitus position DAA. In a learning curve experience of 257 hips. 96% of acetabular components were in the Lewinneck safe zone, the aseptic revision rate was 0.9% and there were no dislocations. Dr Beaule analyzed femoral stem cement mantle with the DAA and posterior approaches by comparing two matched cohorts. Stem alignment and cement mantle quality were equivalent with both approaches. Similarly, Dr Emerson demonstrated technical feasibility and fewer cemented femoral stem failures when compared to cementless stems in a series of 360 DAAs THAs. The final paper of the session presented by Dr Hamilton examined the impact of surgical approach on dislocation after isolated head and liner exchange. Neither the posterior nor the anterior approach was superior in reducing the dislocation rate for these high dislocation risk procedures. The fifth session explored contemporary topics related to anesthesia and pain management. Dr Byrd opened the session with a comparative study evaluating general versus spinal anesthesia for hip arthroscopy. This preliminary study was provoked by the desire to minimize aerosolized exposure early in the COVID-19 pandemic by transitioning to spinal anesthesia. Both anesthetic methods were effective. Dr Austin presented a randomized, double-blind controlled trial comparing spinal anesthetic with mepivacaine, hyperbaric bupivacaine and isobaric bupivacaine. Mepivacaine patients ambulated earlier and were more likely to be discharged the same day. Dr Mont provided a very timely study on the effects of “cannabis use disorder” and THA outcomes. This administrative database study of 44,154 patients revealed this disorder to be associated with longer hospital stays, increased complications rates and higher costs. Dr Bedair investigated whether a highly porous acetabular component submerged in an analgesic solution could enhance perioperative pain management. Interestingly, this novel strategy was associated with a reduction of postoperative pain scores and opioid consumption in 100 experimental patients compared to 100 controls. The concluding paper of the session by Dr Della Valle examined whether decreased discharge opioids led to increased postoperative opioid refills. A large single-center study of 19,428 patients detected a slight increase (5%) in opioid refills but a reduction in total refill morphine milligram equivalents. The final, sixth session of day one considered various challenging aspects of revision hip arthroplasty. Dr Nam started the session with review of preliminary results from a randomized control trial comparing closed incision negative-pressure therapy with a silver-impregnated dressing for wound management in 113 hips undergoing revision arthroplasty. Unlike previous reports, the negative pressure therapy was associated with a higher reoperation rate for wound-related complications. Dr Bostrom highlighted the potential clinical impact of basic biological interventions by establishing the presence of Neutrophil Extracellular Traps (NETS) in fibrotic tissue from human aseptic loosening specimens and in a murine model of unstable tibial implantation. NET inhibition in the murine model prevented the expected tibial implant osseointegration failure. Dr Lombardi presented early 3.3 year clinical results of a highly porous Ti6al4v acetabular component in complex primary and revision arthroplasty. Survivorship for aseptic loosening was 96.6 % and 95.3% for the primary and revision cases, respectively. Dr Schwarzkopf and colleagues explored the impact of time to revision arthroplasty on clinical outcomes. Analysis of 188 revision cases revealed early revisions (less than 2 years from primary) were associated with worse outcomes, longer hospitalizations and higher reoperation rates. Mid-term results for modular dual mobility implants in revision arthroplasty were reviewed by Dr Lachiewicz who reported on 126 hips at a mean 5.5 years. 11% of hips dislocated and the 6 year survival was 91%. An outer head diameter of 48mm or greater was associated with a lower risk of dislocation. Dr Berry concluded the session by discussing the outcomes of treating the challenging problem of interprosthetic femur fractures. A single-center study of 77 cases treated over 32 years demonstrated a 79% success rate free of reoperation at 2 years with 95% of patients being ambulatory. The second day commenced with the seventh session evaluating recent strategies to improve short-term THA outcomes. Dr Bozic and colleagues investigated the association of quality measure public reporting with hip/knee replacement outcomes. Annual trend data from 2010–2011 and 2016–2017 indicate that hospital-level complication and readmission rates decease after the start of public reporting, yet it is difficult to prove a direct effect. Dr Slover reviewed his institutions experience with the Comprehensive Care for Joint Replacement (CJR) model and emphasized that lower CJR target prices make it increasingly difficult for programs to meet target price thresholds. Cost saving strategies including same day discharge and reduction of home health services may result in smaller losses of positive margins. Dr Barsoum reported on the influence of patient and procedure-related risk factors of length of stay after THA. Patient-related risk factors provided substantial predictive value yet procedure-related risk factors (hospital site and surgical approach) remain the main drivers of predicting length of stay. Dr Hozack reviewed an impressive, single surgeon cohort of 3,977 DAA THAs and analyzed adverse events and 90 day perioperative outcomes. Simultaneous bilateral DAA THA was comparable with unilateral or staged bilateral procedures in regards to complications, readmission rate and home discharge rate but with an increased risk of transfusion. To examine the risk of complications with outpatient joint arthroplasty, Dr Della Valle performed a single-surgeon matched cohort analysis comparing outpatient and inpatient hip and knee arthroplasties. Outpatient procedures were not associated with an increased risk of any postoperative complications and actually experienced fewer emergency department visits. The eighth session covered various contemporary challenges in hip arthroplasty care. Dr Griffin began the session with an analysis of the timing of complications associated with two-stage exchange procedures for periprosthetic joint infection (PJI). Of the 189 hips included, 41.6% had a complication and the mortality was 14.1% at 2.5 years, highlighting the morbidity of this treatment method. Dr Fehring provided data assessing the fate of two-stage reimplantation after failed debridement, antibiotics and implant retention (DAIR) for a prosthetic hip infection. This analysis of 114 hips yielded concerning results demonstrating a 42.9% treatment failure of patients treated with a previous DAIR compared to a 12.3% failure rate in patients treated with an initial 2-stage procedure. Dr Jacobs reviewed the analysis of 106 femoral heads with severe corrosion and identified a chemically dominated etching process termed “column damage” to be a detrimental damage mode within CoCr femoral heads that is directly linked to banding within its microstructure. These data indicate that implant alloy microstructure must be optimized to minimize the release of fretting-corrosion products. Simon Mears presented retrospective data from 184 THAs with a dual modular femoral stem. A subgroup of hips with a modular, cobalt chromium femoral neck had a pseudotumor visualized in 15% with only 55% of these having elevated CoCr levels. These findings may support the use of routine follow-up MARS MRI for modular CoCr femoral neck prostheses. The final two studies explored timely issues related to viral illness and hip surgery. Dr Browne analyzed three large administrative databases to elucidate whether patients are at increased risk for viral illnesses following total joint replacement. The incidence of postoperative influenza after total joint replacement was not increased compared to patients not undergoing total joint replacement surgery suggesting that arthroplasty procedures may not heighten the risk of viral illness. In the final paper of the session Dr Haddad presented important data regarding perioperative complications in coronavirus positive patients undergoing surgical treatment of femoral neck fractures. In this multicenter cohort study from the United Kingdom 82 coronavirus positive patients were shown to have longer hospital stays, more critical care unit admissions, higher risk of perioperative complications and an increased mortality compared to 340 coronavirus negative patients. The eighth session had two papers on alternative femoral stem designs and three presentations more focused on femoral fracture treatments. Dr Mihalko focused on the European and US experiences with the Metha femoral neck retaining stem. The US experience mirrored the encouraging results from Europe with a 94% all cause femoral survivorship and a 99.1% femoral aseptic loosening survivorship at 5 years. Dr Kraay summarized dual energy x-ray absorptiometry (DEXA) evaluation of 16 low modulus composite femoral components at long-term follow-up of a mean 22 years. The bone mineral density associated with the implant increased in Gruen zones 2–6 and showed limited decreases in zones 1 and 7. These data support the concept that a low modulus femoral stem may more effectively load the proximal femur. Dr Springer provided data from the American Joint Replacement Registry (AJRR) and by evaluating outcomes of exact matched cohorts of 17,138 patients treated with cementless or cemented femoral implants for femoral neck fractures. Cemented implants were associated with marked reduction in early revision and periprosthetic fractures. However, cemented fixation was associated with an increased mortality at 90 days and 1 year. Additional data from the AJRR was presented by Dr Huddleston who investigated the risk factors for revision surgery after arthroplasty in a cohort of 75,333 femoral neck fractures. THA when compared to hemiarthroplasty was associated with higher early and overall revision rates. Cementless femoral fixation and increased age were also associated with higher rates of any revision. Both of these studies from the AJRR suggest that further consideration should be given to femoral fixation preferences in the femoral neck fracture population. Dr Vail summarized his institution's experience with an interdisciplinary hip fracture protocol for patients undergoing arthroplasty for acute femoral neck fractures. His study compared 157 cases prior to protocol implementation with 114 patients treated after the protocol was established. The impact of the interdisciplinary protocol was impressive as evidenced by a reduced time to operative treatment, length of stay, complication rate and one-year mortality. All being achieved without an increase in readmissions or facility discharges. The final session of the meeting addressed innovations in perioperative care of THA patients. Dr Barrack started the session with an interesting study examining the feasibility and patient preferences regarding telemedicine. A cross-sectional telephone survey of 163 arthroplasty patients indicated that 88% of patients use the internet and 94% own a device capable of videoconferencing. Nevertheless, only 18% of patients preferred a video visit over an in-person clinic visit due to concerns of inferior care. Dr Barnes quantified preoperative optimization work in 100 arthroplasty patients by using EMR activity logs and determined the surgical team spends an average 75 minutes per case on preoperative work activities. Dr Duwelius reported the early outcomes of primary THA with a smartphone-based exercise and educational platform compared to standard of care controls. A randomized control trial design with 365 patients demonstrated similar outcomes and non-inferiority of the smartphone platform relative to complications, readmissions, emergency room/urgent care visits. The association of controlled substance use with THA outcomes was assessed by Dr Higuera Rueda. A quantitative assessment using the NarxCare score identified 300 and above as a score associated with adverse outcomes after THA. Dr Macaulay reviewed data from a large retrospective study of 1,825 THAs indicating that discontinuation of intermittent pneumatic compression devices does not increase the risk of venous thromboembolism in standard risk patients being treated with 81mg ASA BID as prophylaxis. Dr Antoniou presented the final paper of the meeting investigating potential changes in patient health status as an indication for surgery over time. Data from this large systematic review of the literature found patients undergoing THA at similar health status to the past with no influence form patient age, gender, year of enrollment or geographic region. As summarized above, the 2020 virtual Hip Society Summer Meeting was rich in scientific content, productive discussion and a collaborative spirit. This collective body of work will result in impactful scientific contributions and will serve as a foundation for future innovation and advancements in the treatment of hip disease


Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims

Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.

Methods

Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m2 (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 67 - 67
1 Oct 2018
Goldman AH Berry DJ Lewallen DG Trousdale RT Sierra RJ Abdel MP
Full Access

Introduction. Historically, the most common indications for re-revision of a total hip arthroplasty (THA) have been aseptic loosening, instability, infection, and peri-prosthetic fracture. As revision implants and techniques have evolved and improved, understanding why contemporary revision THAs fail is important to direct further improvement and innovation. As such, the goals of this study were to determine the implant survivorship of contemporary revision THAs, as well as the most common indications for re-revision. Methods. We retrospectively reviewed 2568 aseptic revision THAs completed at our academic institution between 2005 and 2015 through our total joint registry. There were 34% isolated acetabular revisions, 18% isolated femoral revisions, 28% both component revisions, and 20% modular component exchanges. The mean age at index revision THA was 66 years, and 46% were males. The most common indications for the index revision THA were aseptic loosening (21% acetabular, 15% femoral, 5% both components), polyethylene wear and osteolysis (18%), instability (13%), fracture (11%), and other (17%). Mean follow-up was 6 years. Results. There were 211 re-revision THAs during the study period in this cohort. The overall survivorship free of any re-revision at 2, 5, and 10 years was 94%, 92%, and 88%, respectively. The most common reasons for re-revision were hip instability (52%), peri-prosthetic fracture (11%), femoral aseptic loosening (10%), acetabular aseptic loosening (8%), infection (6%), polyethylene wear (3%), and other (10%). A pre-revision diagnosis of instability had the worst survivorship free of revision at 10 years (79%). Conclusion. Compared to historical series, the 88% survivorship free of any re-revision at 10 years in a difficult revision cohort is notably improved. As implant fixation has improved, aseptic loosening has become much less common after revision THA, and instability has come to account for more than half of re-revisions. Methods to further mitigate this risk may be emphasized during index revision THA


Bone & Joint Research
Vol. 1, Issue 12 | Pages 324 - 332
1 Dec 2012
Verhelst L Guevara V De Schepper J Van Melkebeek J Pattyn C Audenaert EA

The aim of this review is to evaluate the current available literature evidencing on peri-articular hip endoscopy (the third compartment). A comprehensive approach has been set on reports dealing with endoscopic surgery for recalcitrant trochanteric bursitis, snapping hip (or coxa-saltans; external and internal), gluteus medius and minimus tears and endoscopy (or arthroscopy) after total hip arthroplasty. This information can be used to trigger further research, innovation and education in extra-articular hip endoscopy


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 6 - 6
1 Oct 2018
Naudie DD Paish AD Nikolov HN Chmiel T El-Warrak AO Welch ID Teeter MG Holdsworth DW
Full Access

Introduction. As new innovations are developed to improve the longevity of joint replacement components, preclinical testing is necessary in the early stages of research into areas such as osseointegration, metal-cartilage wear and periprosthetic joint infection (PJI). Large-animal studies that test load-bearing components are expensive, however, requiring that animals be housed in special facilities that are not available at all institutions. Comparably, small animal models, such as the rat, offer several advantages including lower cost. Load-bearing implants remain difficult to manufacture via traditional methods in the sizes required for small-animal testing. Recent advances in additive manufacturing (3D metal-printing) have allowed for the creation of miniature joint replacement components in a variety of medical-grade metal alloys. The objective of this work is to create and optimize an image-based 3D-printed rat hip implant system that will allow in vivo testing of functional implant properties in a rat model. Methods. A database of n=25 previously-acquired, 154μm micro-CT volumes (eXplore Locus Ultra, GE Medical) of male Sprague-Dawley rats (390–610g) were analyzed to obtain spatial and angular relationships between several anatomical features of the proximal rat femora. Mean measurements were used to guide the creation of a femoral implant template in computer-aided design software (Solidworks, Dassault Systemes). Several different variations were created, including collarless and collared designs, in a range of sizes to accommodate rats of various weights. Initial prototypes were 3D-printed 316L stainless steel with subsequent iterations printed in Ti6Al4V titanium and F75 cobalt-chrome. Implants were post-processed via sandblasting, hand-polishing, ultrasonic bath, and sterilization in an autoclave. Innate surface texturing was left on manufactured stems to promote osseointegration. Surgical implantation was performed in three live Sprague-Dawley rats (900g, 500g, 750g) with preservation of muscle attachments to the greater trochanter. Micro-CT imaging and X-ray fluoroscopy were performed post-operatively on each animal at 1 day, and 1, 3, 9 and 12 weeks to evaluate gait and component positioning. Results. Implantation of components was successful and each animal was observed to ambulate on its affected limb immediately following recovery from surgery. The 900g rat, given a collarless 316L stainless steel component, was kept for 11 months post-implantation before succumbing to old age. Micro-CT and fluoroscopic findings revealed no evidence of implant subsidence. The 500g animal, given a collarless 316L stainless steel implant, showed evidence of implant subsidence at 3 weeks, with full subsidence and hip dislocation at 12 weeks. The 750g rat, given a collared F75 cobalt-chrome implant, was observed ambulating on its affected limb, but experienced implant rotation and failure at 9 weeks. Conclusions. We report the first hip hemi-arthroplasty in a rat using a 3D-printed metal implant. This model aims to provide a low-cost platform for studying osseointegration, metal-cartilage interactions, and PJI using a functional, loaded implant. Efforts to further optimize the surgical approach will be made to reduce early implant loosening. A study with larger sample sizes is needed to determine if implants can be installed repeatedly, without complications, before the utility of this approach can be validated. Future work will include surface preparations on implant stems, with micro-CT to longitudinally track changes at the bone-metal interface, and gait analysis on a radiolucent treadmill to quantify post-operative kinematics


Bone & Joint Open
Vol. 5, Issue 9 | Pages 742 - 748
10 Sep 2024
Kodumuri P Joshi P Malek I

Aims

This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices.

Methods

Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 260 - 268
1 Apr 2024
Broekhuis D Meurs WMH Kaptein BL Karunaratne S Carey Smith RL Sommerville S Boyle R Nelissen RGHH

Aims

Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions.

Methods

A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 765 - 772
14 Sep 2021
Silitonga J Djaja YP Dilogo IH Pontoh LAP

Aims

The aim of this study was to perform a cross-cultural adaptation of Oxford Hip Score (OHS) to Indonesian, and to evaluate its psychometric properties.

Methods

We performed a cross-cultural adaptation of Oxford Hip Score into Indonesian language (OHS-ID) and determined its internal consistency, test-retest reliability, measurement error, floor-ceiling effect, responsiveness, and construct validity by hypotheses testing of its correlation with Harris Hip Score (HHS), vsual analogue scale (VAS), and Short Form-36 (SF-36). Adults (> 17 years old) with chronic hip pain (osteoarthritis or osteonecrosis) were included.


Bone & Joint Open
Vol. 1, Issue 10 | Pages 653 - 662
20 Oct 2020
Rahman L Ibrahim MS Somerville L Teeter MG Naudie DD McCalden RW

Aims

To compare the in vivo long-term fixation achieved by two acetabular components with different porous ingrowth surfaces using radiostereometric analysis (RSA).

Methods

This was a minimum ten-year follow-up of a prospective randomized trial of 62 hips with two different porous ingrowth acetabular components. RSA exams had previously been acquired through two years of follow-up. Patients returned for RSA examination at a minimum of ten years. In addition, radiological appearance of these acetabular components was analyzed, and patient-reported outcome measures (PROMs) obtained.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1654 - 1661
1 Dec 2020
Perelgut ME Polus JS Lanting BA Teeter MG

Aims

The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach.

Methods

Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 78 - 84
1 Jul 2020
Roof MA Feng JE Anoushiravani AA Schoof LH Friedlander S Lajam CM Vigdorchik J Slover JD Schwarzkopf R

Aims

Previous studies have reported an increased risk for postoperative complications in the Medicaid population undergoing total hip arthroplasty (THA). These studies have not controlled for the surgeon’s practice or patient care setting. This study aims to evaluate whether patient point of entry and Medicaid status plays a role in quality outcomes and discharge disposition following THA.

Methods

The electronic medical record at our institution was retrospectively reviewed for all primary, unilateral THA between January 2016 and January 2018. THA recipients were categorized as either Medicaid or non-Medicaid patients based on a visit to our institution’s Hospital Ambulatory Care Center (HACC) within the six months prior to surgery. Only patients who had been operated on by surgeons (CML, JV, JDS, RS) with at least ten Medicaid and ten non-Medicaid patients were included in the study. The patients included in this study were 56.33% female, had a mean age of 60.85 years, and had a mean BMI of 29.14. The average length of follow-up was 343.73 days.


Bone & Joint Research
Vol. 9, Issue 4 | Pages 182 - 191
1 Apr 2020
D’Ambrosio A Peduzzi L Roche O Bothorel H Saffarini M Bonnomet F

Aims

The diversity of femoral morphology renders femoral component sizing in total hip arthroplasty (THA) challenging. We aimed to determine whether femoral morphology and femoral component filling influence early clinical and radiological outcomes following THA using fully hydroxyapatite (HA)-coated femoral components.

Methods

We retrospectively reviewed records of 183 primary uncemented THAs. Femoral morphology, including Dorr classification, canal bone ratio (CBR), canal flare index (CFI), and canal-calcar ratio (CCR), were calculated on preoperative radiographs. The canal fill ratio (CFR) was calculated at different levels relative to the lesser trochanter (LT) using immediate postoperative radiographs: P1, 2 cm above LT; P2, at LT; P3, 2 cm below LT; and D1, 7 cm below LT. At two years, radiological femoral component osseointegration was evaluated using the Engh score, and hip function using the Postel Merle d’Aubigné (PMA) and Oxford Hip Score (OHS).


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims

Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years.

Patients and Methods

A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 31 - 36
1 Jun 2019
Nam D Nunley RM Clohisy JC Lombardi AV Berend KR Barrack RL

Aims

Whether patient-reported pain differs among surgical approaches in total hip arthroplasty (THA) remains unclear. This study’s purposes were to determine differences in pain based on surgical approach (direct anterior (DA) vs posterolateral (PL)) and PL approach incision length.

Patients and Methods

This was a retrospective investigation from two centres and seven surgeons (three DA, three PL, one both) of primary THAs. PL patients were categorized for incision length (6 cm to 8 cm, 8 cm to 12 cm, 12 cm to 15 cm). All patients had cementless femoral and acetabular fixation, at least one year’s follow-up, and well-fixed components. Patients completed a pain-drawing questionnaire identifying the location and intensity of pain on an anatomical diagram. Power analysis indicated 800 patients in each cohort for adequate power to detect a 4% difference in pain (alpha = 0.05, beta = 0.80).


Bone & Joint Research
Vol. 8, Issue 6 | Pages 275 - 287
1 Jun 2019
Clement ND Bardgett M Merrie K Furtado S Bowman R Langton DJ Deehan DJ Holland J

Objectives

Our primary aim was to describe migration of the Exeter stem with a 32 mm head on highly crosslinked polyethylene and whether this is influenced by age. Our secondary aims were to assess functional outcome, satisfaction, activity, and bone mineral density (BMD) according to age.

Patients and Methods

A prospective cohort study was conducted. Patients were recruited into three age groups: less than 65 years (n = 65), 65 to 74 years (n = 68), and 75 years and older (n = 67). There were 200 patients enrolled in the study, of whom 115 were female and 85 were male, with a mean age of 69.9 years (sd 9.5, 42 to 92). They were assessed preoperatively, and at three, 12 and, 24 months postoperatively. Stem migration was assessed using Einzel-Bild-Röntgen-Analyse (EBRA). Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), EuroQol-5 domains questionnaire (EQ-5D), short form-36 questionnaire (SF-36,) and patient satisfaction were used to assess outcome. The Lower Extremity Activity Scale (LEAS), Timed Up and Go (TUG) test, and activPAL monitor (energy expelled, time lying/standing/walking and step count) were used to assess activity. The BMD was assessed in Gruen and Charnley zones.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 27 - 32
1 Apr 2017
Cnudde PHJ Kärrholm J Rolfson O Timperley AJ Mohaddes M

Aims

Compared with primary total hip arthroplasty (THA), revision surgery can be challenging. The cement-in-cement femoral revision technique involves removing a femoral component from a well-fixed femoral cement mantle and cementing a new stem into the original mantle. This technique is widely used and when carried out for the correct indications, is fast, relatively inexpensive and carries a reduced short-term risk for the patient compared with the alternative of removing well-fixed cement. We report the outcomes of this procedure when two commonly used femoral stems are used.

Patients and Methods

We identified 1179 cement-in-cement stem revisions involving an Exeter or a Lubinus stem reported to the Swedish Hip Arthroplasty Register (SHAR) between January 1999 and December 2015. Kaplan-Meier survival analysis was performed.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 379 - 386
1 Sep 2016
Pahuta M Smolders JM van Susante JL Peck J Kim PR Beaule PE

Objectives

Alarm over the reported high failure rates for metal-on-metal (MoM) hip implants as well as their potential for locally aggressive Adverse Reactions to Metal Debris (ARMDs) has prompted government agencies, internationally, to recommend the monitoring of patients with MoM hip implants. Some have advised that a blood ion level >7 µg/L indicates potential for ARMDs. We report a systematic review and meta-analysis of the performance of metal ion testing for ARMDs.

Methods

We searched MEDLINE and EMBASE to identify articles from which it was possible to reconstruct a 2 × 2 table. Two readers independently reviewed all articles and extracted data using explicit criteria. We computed a summary receiver operating curve using a Bayesian random-effects hierarchical model.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 754 - 760
1 Jun 2016
Malek IA Royce G Bhatti SU Whittaker JP Phillips SP Wilson IRB Wootton JR Starks I

Aims

We assessed the difference in hospital based and early clinical outcomes between the direct anterior approach and the posterior approach in patients who undergo total hip arthroplasty (THA).

Patients and Methods

The outcome was assessed in 448 (203 males, 245 females) consecutive patients undergoing unilateral primary THA after the implementation of an ‘Enhanced Recovery’ pathway. In all, 265 patients (mean age: 71 years (49 to 89); 117 males and 148 females) had surgery using the direct anterior approach (DAA) and 183 patients (mean age: 70 years (26 to 100); 86 males and 97 females) using a posterior approach. The groups were compared for age, gender, American Society of Anesthesiologists grade, body mass index, the side of the operation, pre-operative Oxford Hip Score (OHS) and attendance at ‘Joint school’. Mean follow-up was 18.1 months (one to 50).


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1031 - 1037
1 Aug 2015
da Assunção RE Pollard TCB Hrycaiczuk A Curry J Glyn-Jones S Taylor A

Periprosthetic femoral fracture (PFF) is a potentially devastating complication after total hip arthroplasty, with historically high rates of complication and failure because of the technical challenges of surgery, as well as the prevalence of advanced age and comorbidity in the patients at risk.

This study describes the short-term outcome after revision arthroplasty using a modular, titanium, tapered, conical stem for PFF in a series of 38 fractures in 37 patients.

The mean age of the cohort was 77 years (47 to 96). A total of 27 patients had an American Society of Anesthesiologists grade of at least 3. At a mean follow-up of 35 months (4 to 66) the mean Oxford Hip Score (OHS) was 35 (15 to 48) and comorbidity was significantly associated with a poorer OHS. All fractures united and no stem needed to be revised. Three hips in three patients required further surgery for infection, recurrent PFF and recurrent dislocation and three other patients required closed manipulation for a single dislocation. One stem subsided more than 5 mm but then stabilised and required no further intervention.

In this series, a modular, tapered, conical stem provided a versatile reconstruction solution with a low rate of complications.

Cite this article: Bone Joint J 2015;97-B:1031–7.