Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 46 - 46
1 Sep 2012
Fong J Dunbar MJ Wilson DA Hennigar A Francis P Glazebrook M
Full Access

Purpose

The purpose of this study was to assess the biomechanical stability of the a total ankle arthroplasty system using longitudinal migration (LM) and inducible displacement (ID) measures. This study is the first study of its kind to assess total ankle arthroplasty (TAA) implant micromotion using model-based radiostereometric analysis (MBRSA).

Method

Twenty patients underwent TAA that implanted the Mobility(TM) (DePuy, Warsaw IN). The mean (SD) age was 60.4 (12.5) and BMI was 29.1 (2.8) kg/m2. One surgeon performed all surgeries. All patients included in this study had given informed consent. Capital Health Research Ethics Board had approved this study.

Uniplanar medial-lateral RSA X-ray exams were taken postop (double exam), at six wk, three mth, six mth, one yr and two yr followup times using a supine, unloaded position. Standing medial-lateral exams were taken at three mth, six mth, one yr and two yr followup intervals.

LM and ID micromotions were assessed using Model-based RSA 3.2 software (Medis specials, Leiden, The Netherlands). Implant micromotions (x, y, z, Rx, Ry, Rz, MTPM) were determined and assessed for each subject using model-based pose estimation, and the implant-based coordinate system. The Elementary Geometric Shapes module from the Model-based RSA 3.2 software was used to assess the micromotion of the tibial component spherical tip due to implant symmetry.