Olecranon Osteotomy is a common approach used in the management of intraarticular distal humerus fractures. Significant complication rates have been associated with this procedure, including non-union rates of 0–13% and
The treatment of fracture-related infections (FRI) focuses on obtaining fracture healing and eradicating infection to prevent osteomyelitis. Treatment guidelines include removal, exchange, or retention of the implants used according to the stability of the fracture and the time from the infection. Infection of a fracture in the process of healing with a stable fixation may be treated with implant retention, debridement, and antibiotics. Nonetheless, the retention of an intramedullary nail is a potential risk factor for failure, and it is recommended to exchange or remove the nail. This surgical approach implies additional life-threatening risks in elderly fragile hip fracture patients. Our study aimed to analyze the results of implant retention for the treatment of infected nails in elderly hip fracture patients. Our retrospective analysis included patients 65 years of age or older with an acute fracture-related infection treated with implant retention from 2012 to 2020 in 6 Spanish hospitals with a minimum 1-year follow-up. Patients that required open reduction during the initial fracture surgery were excluded. Variables included in our analysis were patient demographics, type of fracture, date of FRI diagnosis, causative microorganism, and outcome. Treatment success was defined as fracture healing with infection eradication without the need for further hospitalization.Aim
Methods
Aim. Following clean (class I, not contaminated) surgical procedures, the rate of surgical site infection (SSI) should be less than approximately 2%. However, an infection rate of 12.2% has been reported following removal of orthopedic implants used for treatment of fractures below the knee. The objective of this trial was to evaluate the effect of a single dose of preoperative antibiotic prophylaxis on the incidence of SSIs following removal of orthopedic implants used for treatment of fractures below the knee. Method. This multicenter, double-blind, randomized clinical trial included 500 patients from 19 hospitals with a follow-up of 6 months. Eligible were patients aged 18 to 75 years with previous surgical treatment for fractures below the knee who were undergoing removal of orthopedic implants. Exclusion criteria were an active infection or fistula, antibiotic treatment, reimplantation of osteosynthesis material in the same session, allergy for cephalosporins, known kidney disease, immunosuppressant use, or pregnancy. The intervention was a single preoperative intravenous dose of 1000 mg of cefazolin (cefazolin group, n = 228) or sodium chloride (0.9%; saline group, n = 242). Primary outcome was SSI within 30 days as measured by the criteria from the US Centers for Disease Control and Prevention. Secondary outcome measures were functional outcome, health-related quality of life, and patient satisfaction. Results. Among 477 randomized patients (mean age, 44 years [SD, 15]; women, 274 [57%]; median time from orthopedic implant placement, 11 months [interquartile range, 7–16]), 470 patients completed the study. Sixty-six patients developed an SSI (14.0%): 30 patients (13.2%) in the cefazolin group vs 36 in the saline group (14.9%) (absolute risk difference, −1.7 [95% CI, −8.0 to 4.6], P = .60). Conclusions. In patients undergoing surgery for removal of orthopedic implants used for treatment of fractures below the knee, a single preoperative dose of intravenous cefazolin compared with placebo did not reduce the risk of surgical site infection within 30 days following
To date, the value of culture results after a debridement, antibiotics and implant retention (DAIR) for early (suspected) prosthetic joint infection (PJI) as risk indicators in terms of prosthesis retention is not clear. At one year follow-up, the relative risk of prosthesis removal was determined for culture-positive and culture-negative DAIRs after primary total hip or knee arthroplasty. The secondary aim was to explore differences in patient characteristics, infection characteristics and outcomes between these two groups. A retrospective regional registry study was performed in a group of 359 patients (positive cultures: n = 299, negative cultures n = 60) undergoing DAIR for high suspicion of early PJI in the period from 2014 to 2019. Differences in patient characteristics, deceased patients and number of subsequent DAIRs between the positive and negative DAIR groups were analyzed using independent t-tests, Mann-Whitney, Pearson's Chi-square tests and Fisher's Exact tests.Aim
Methods
Aims. Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. Methods. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages. Results. Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before
Ligament reconstruction following multi-ligamentous knee injuries involves graft fixation in bone tunnels using interference screws (IS) or cortical suspensory systems. Risks of IS fixation include graft laceration, cortical fractures, prominent hardware, and inability to adjust tensioning once secured. Closed loop suspensory (CLS) fixation offers an alternative with fewer graft failures and improved graft-to-tunnel incorporation. However, graft tensioning cannot be modified to accommodate errors in tunnel length evaluation. Adjustable loop suspensory (ALS) devices (i.e., Smith & Nephew Ultrabutton) address these concerns and also offer the ability to sequentially tighten each graft, as needed. However, ALS devices may lead to increased graft displacement compared to CLS devices. Therefore, this study aims to report outcomes in a large clinical cohort of patients using both IS and CLS fixation. A retrospective review of radiographic, clinical, and patient-reported outcomes following ligament reconstruction from a Level 1 trauma centre was completed. Eligible patients were identified via electronic medical records using ICD-10 codes. Inclusion criteria were patients 18 years or older undergoing ACL, PCL, MCL, and/or LCL reconstruction between January 2018 and 2020 using IS and/or CLS fixation, with a minimum of six-month post-operative follow-up. Exclusion criteria were follow-up less than six months, incomplete radiographic imaging, and age less than 18 years. Knee dislocations (KD) were classified using the Schenck Classification. The primary outcome measure was
Introduction. Approximately 2,000 Skeletal transcutaneous osseointegration (STOI) procedures have been performed worldwide as of 2020, more than half of which have been performed by the Osseointegration Group of Australia using a press-fit technique with either ILP or OPL implant designs. Despite the consistently demonstrated clinical benefits, concerns regarding potential complications following STOI have slowed its widespread adoption. As more patients are followed for a longer period of time, longitudinal studies have confirmed complication rates are very acceptable, similar to those of total ankle and total elbow replacements. One of the major risk category is
Aim. Treatment recommendations for periprosthetic joint infections (PJI) include surgical debridement, antibiotic therapy or staged revision. In surgical related foot and ankle infections (SR-FAI),
Aims. This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported. Methods. This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed. Results. Adjacent to the nail’s telescoping junction, osteolytic changes were observed in bi-planar radiographs of 20/57 segments (35%) after a mean of 9.5 months (95% confidence interval 7.2 to 11.9) after surgery. A total of 8/20 patients with osseous alterations (40%) reported rest and ambulation pain of the lengthened segment during consolidation. So far, 24 Stryde nails were retrieved and in 20 (83%) macroscopic corrosion was observed at the nail’s telescoping junction. Before
Aim. To determine mortality and outcomes of patients diagnosed with fracture-related infections (FRIs). Method. FRI patients treated at a trauma centre between 2001 and 2020 were analysed. The primary outcome was 1-year mortality; mortality associations with FRI organism, depth of involvement, and temporality were investigated with multivariable survival analysis. Healthcare-associated and serological outcomes were reported as secondary outcomes. Results. 311 FRIs with mean age of 67.0 and median Charlson comorbidity index of 0 were analysed. Methicillin-sensitive Staphylococcus aureus (MSSA) (29.9%) was the most frequently implicated organism. The majority of FRIs were deep infections (62.7%). FRIs were diagnosed at a median of 40 (IQR 15–200) days post index surgery. The mean follow-up was 5.9 years. One-year mortality amounted to 17.7%. MSSA FRIs were associated with better survival (adj HR 0.34, 95%CI 0.15–0.76, p=0.008). There was no difference in survivorship between deep or superficial FRI (adj HR 0.86, 95%CI 0.62–1.19, p=0.353) or in relation to onset time (adj HR 1.0, 95%CI 0.99–1.00, p=0.943).
Abstract. Introduction. Displaced olecranon fractures in the elderly are challenging due to associated comorbidities, poor tissue quality, high risk of complications, and the possible need for
Abstract. Background. Aim of this study is to determine the difference between re-operation rates after conventional Methods of fixation of patella fractures using Metallic implants and novel technique of all suture fixation using Ethibond or fiber tape. Methods. This is a retrospective comparative analysis involving 62 patients who had a transverse patellar fracture and underwent surgery between January 2013 to December 2021. Selected patients were divided, based on different fixation methods used, into four groups - TBW group, CC screw group, Encirclage group and Suture Fixation Group. Patients were followed till bone union was evident on radiographs. Number of patients in Metallic implant group undergoing repeat operation were compared with the patients who underwent patella fracture fixation using all suture technique. Mean and standard deviation (SD) were calculated for all continuous variables. Mean of the two groups was compared using unpaired t-test. Results. TBW was the most common method of fixation used in 41(66.1%) patients. 7 patients each underwent surgery using CC screw, Encirclage +/− TBW, and suture fixation respectively. Bone union was seen in about 85% of patients in all the groups suggesting all treatment modalities lead to good fracture healing. 15 patients(36.6%) of patients in TBW group and 3 patients(42.9%) in encirclage group had
Complications such as implant loosening, infection, periprosthetic fracture or instability may lead to revision arthroplasty procedures. There is limited literature comparing single-stage and two-stage revision shoulder arthroplasty. This study aims to compare clinical outcomes and cost benefit between single-stage and two-stage revision procedures. Thirty-one revision procedures (mean age 72+/-7, 15 males and 16 females) performed between 2016 and 2021 were included (27 revision RSA, 2 revision TSA, 2 failed ORIFs). Two-stage procedures were carried out 4-6 weeks apart. Single-stage procedures included debridement,
Aim. Late acute prosthetic joint infections (PJI) treated with surgical debridement and implant retention (DAIR) have a high failure rate. The aim of our study was to evaluate treatment outcome in late acute PJIs treated with DAIR versus
Aim. The number of operatively treated clavicle fractures has increased over the past decades. Consequently, this has led to an increase in secondary procedures required to treat complications such as fracture-related infection (FRI). The primary objective of this study was to assess the clinical and functional outcome of patients treated for FRI of the clavicle. The secondary objectives were to evaluate the healthcare costs and propose a standardized protocol for the surgical management of this complication. Method. All patients with a clavicle fracture who underwent open reduction and internal fixation (ORIF) between 1 January 2015 and 1 March 2022 were retrospectively evaluated. This study included patients with an FRI who were diagnosed and treated according to the recommendations of a multidisciplinary team at the University Hospitals Leuven, Belgium. Results. We evaluated 626 patients with 630 clavicle fractures who underwent ORIF. In total, 28 patients were diagnosed with an FRI. Of these, eight (29%) underwent definitive
Traditional socket prosthesis (TSP) rehabilitation for amputees is associated with substantial dissatisfaction due to poor mobility and pain from soft tissue squeezing. Osseointegration (OI), eliminates skin compression and prosthesis fit issues, providing superior mobility and quality of life (QOL) for most amputees. The potential for OI to benefit patients with exceptionally poor mobility is understudied. To address this knowledge gap, this project investigated the mobility and QOL changes. A retrospective review was performed to identify transfemoral amputees who presented with wheelchair-bound mobility (K0) and had at least five years of post-osseointegration follow-up. Outcome measures included changes in mobility (K-level, daily prosthesis wear hours, Timed Up and Go (TUG), 6 minute walk test (6MWT)) and QOL (Questionnaire for persons with a Transfemoral Amputation (QTFA); Short Form Health Survey 36 (SF36). Adverse events recorded included debridement for infection, implant revision surgery, fractures, and implant failures. 9 patients with mean age 48.2±7.7 (range 34-59) years were included. The proportion of patients achieving K-level >2 improved from 0/9=0% to [9/9=100%], p<0.001. The 6MWT improved from 0±0 to 320.65±57 meters (p<0.001). The TUG improved from incapable to 10.68±2.7 seconds (p<0.001). Statistically significant QOL metrics included QTFA global score (33.33±31 vs 68.52±21, p=0.039), SF36 physical component score (30.03±6.3 vs 42.34±12, p=0.023) and the SF36 mental component score (47.89±8.8 vs 51.95±10.4, p=0.332). Six patients required operative intervention to address complications. Five developed infections: three had debridement, and 2 required
Aim. Prosthetic joint infection (PJI) due to Candida spp. is a severe complication of arthroplasty but is little reported. This study describes Candida PJI epidemiology, management, and outcome. Method. We performed a retrospective, observational multinational study with support of the European Society of Clinical Microbiology and Infectious Diseases (ESCMID). Patients diagnosed with PJI due to Candida spp. between 1990 and 2021 were included. Demographic, clinical, laboratory, imaging, medical/surgical treatment, and outcome data were collected within a standardized database. Treatment failure was defined either as a Candida infection recurrence, superinfection, or death due to infection. Results. Data from 151 patients across 18 centers were analyzed. Mean age was 69.5 ± 13.1yo, 78 (51.7%) patients were male, and 21 (13.9%) were immunosuppressed. Site of infection included hip (55.0%), knee (41.7%), shoulder (2.6%), and femur (0.7%). Twenty-five (16.6%) patients were febrile, and 58 (38.4%) had fistula. Mean number of previous surgeries on the same anatomical site was 3.3±2.3. Surgeries were DAIR (33.8%), one-stage exchange (19.9%), two-stage exchange (39.1%), and
Aim. The time to onset of symptoms after fracture fixation is still commonly used to classify fracture-related infections (FRI). Early infections (<2 weeks) can often be treated with debridement, systemic antibiotics, irrigation, and implant preservation (DAIR). Late infections (>10 weeks) typically require
Aim. There are no studies in literature that analyze the effectiveness of closed-incisional negative pressure wound therapy (ciNPWT) in the treatment of bone and joint infections (BJI). The aim of the study was to evaluate the efficacy and the safety of the application of ciNPWT in the postsurgical wound management of patients with osteoarticular infections. Method. We conducted a perspective single-center study on patients with BJI treated between 01/2022 and 10/2022 with ciNPWT dressing application at the end of the surgical procedure. All patients were treated by a multidisciplinary team (MDT) approach and operated by the same surgical equipe. Inclusion criteria were: presence of periprosthetic joint infection (PJI), fracture-related infection (FRI), osteomyelitis (OM), septic arthritis (SA) surgically treated, after which ciNPTW was applied over the closed surgical wound. 30 patients (19M, 11F) have been analyzed with mean age of 56,10±17,11 years old; BJIs were all localized in the lower limb (16 PJI, 12 FRI, 1 SA, 1 OM). Results. We considered the following clinical local pre-operative parameters: presence of fistula (10 patients, 33,33%), presence of erythema (18 patients, 60%), presence of previous flap in the incisional site (7 patients, 23,33%). In 11 cases (36,67%) more than 3 previous surgical procedures were performed in the surgical site. The following surgical procedures were performed: 8 debridement and
Aim. Treatment algorithms for fracture-related nonunion depend on the presence or absence of bacterial infection. However, the manifestation of septic nonunion varies. Low-grade infections, unlike manifest infections, lack clinical signs of infection and present similarly to aseptic nonunion. The clinical importance of low-grade infection in nonunion is not entirely clear. Therefore, the aim of this study was to evaluate the clinical relevance of low-grade infection in the development and management of femoral or tibial nonunion. Method. A prospective, multicenter clinical study enrolled patients with nonunion and regular healed fractures. Preoperatively, complete blood count without differential, C-reactive protein (CRP), and procalcitonin were obtained, clinical signs of infection were recorded, and a suspected septic or aseptic diagnosis was made based on history and clinical examination. During surgical nonunion revision or routine