Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 387 - 391
1 Apr 2002
Sandén B Olerud C Petrén-Mallmin M Larsson S

We investigated the effects of hydroxyapatite (HA) coating on the purchase of pedicle screws. A total of 23 consecutive patients undergoing lumbar fusion was randomly assigned to one of three treatment groups. The first received uncoated stainless-steel screws, the second screws which were partly coated with HA, and the third screws which were fully coated. The insertion torque was recorded. After 11 to 16 months, 21 screws had been extracted. The extraction torque was recorded. Radiographs were taken to assess fusion and to detect loosening of the screws. At removal, the extraction torques exceeded the upper limit of the torque wrench (600 Ncm) for many HA-coated screws. The calculated mean extraction torque was 29 ± 36 Ncm for the uncoated group, 447 ± 114 Ncm for the partly-coated group and 574 ± 52 Ncm for the fully-coated group. There were significant differences between all three groups (p < 0.001). There were more radiolucent zones surrounding the uncoated screws than the HA-coated screws (p < 0.001). HA coating of pedicle screws resulted in improved fixation with reduced risk of loosening of the screws


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 70 - 70
1 Apr 2012
Mueller M Hoskinson S Shepperd J
Full Access

We have studied two matching cohorts of patients treated by Dynesys flexible stabilisation with and without hydroxyapatite (HA) coating of the pedicle screws. From our series of 570 Dynesys procedures, we studied patients with HA coated screws with a minimum one year follow-up. Patients were entered prospectively and followed up at 6 weeks, 3, 6, and 12 months and annually thereafter. Plain radiographs were obtained annually. 58 patients (26 males, 32 females, mean age 55 years at surgery) underwent Dynesys stabilisation with HA coated screws. The data was compared with 69 patients who underwent Dynesys stabilisation with non-coated pedicle screws between 2004 and 2006 (26 male, 53 female, mean age 54 years). Outcome measures were screw loosening, breakage, implant removal or revision. A total of 320 HA coated pedicle screws were inserted. 12 patients were lost to follow-up. 2 patients underwent subsequent level extension, and 2 had their implants removed. There were four screw breakages in three patients, all affecting S1 screws. There was no evidence of screw loosening in any patient. In the non-HA coated group 354 pedicle screws were inserted. 5 patients required revision or subsequent surgery. 12 patients had screw loosening and required implant removal. There was a significant improvement of anchorage of the HA coated screws. Change to HA coating was investigated because of high loosening in plain screws. The improvement has been highly significant. Flexible stabilisation is a better model than fusion because the implant remains under constant load. Disclosure: The authors did not receive any outside funding in support of preparation of this work


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 34 - 34
1 Jul 2012
Koroma KE Ding M Wendt D Martin I Martinetti R Jespersen S Overgaard S
Full Access

Background. For bone grafting procedures, the use of autologous bone is considered the gold standard, as it is has a better healing capacity compared to other alternatives as allograft and synthetic bone substitutes. However, as there are several drawbacks related to autografting (infection, nerve- or vascular damage, chronic pain problems, abdominal herniation), there has been a targeted effort to improve the healing capacities of synthetic bone substitutes. Aim. To evaluate the performance of a carbonated osteoionductive hydroxyapatite (CHA) scaffold of clinical relevant size (Ø=15mm, H=50mm) in a sheep model of multi level posterolateral intertransverse lumbar spine fusion after activation with autologous bone marrow nuclear cells (BMNC) in a flow perfusion bioreactor. Method. Two groups were included in the study, autograft (n=6) and CHA scaffold (n=6) CHA. A paired design was used between and within the groups as lumbar posterolateral arthrodesis was performed in sheep on two levels (L2-L3, L5-L6) +/− BMNC, respectively. Before implantation, the CHA scaffold was cultured in a flow perfusion bioreactor system with BMNC for 21 days, and the autograft group was supplemented with isolated BMNC during the procedure. Micro tomography was used to evaluate fusion rate and the microarchitectural properties of the explants after an observation period of four months. Results. In the autograft group, the healing rate was 83.3% irrespective of the presence BMNC, and in the CHA group, 66.7% fused in the presence of BMNC, and 33.3% without. The microarchitectural data suggested the autograft group to be superior to the CHA scaffold regarding mechanical properties, however porosity decreased significantly (p=0.001) in the CHA scaffold group suggesting deposition of mineralized bone matrix. Conclusion. Based on the fusion rate and micro architectural properties, we consider the CHA scaffold fully capable of new bone formation, and that the presence of BMNC has a positive effect on the fusion rate in a challenging model of bone healing


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 72 - 72
1 Jun 2012
Mueller M Hoskinson S Shepperd J
Full Access

Objective

From our series of 570 Dynesys flexible stabilisation procedures, we studied two prospective series of patients with a minimum one-year follow-up comparing uncoated and hydroxyapatite-coated (HA) screws.

Methods

Patients were entered prospectively and followed up at 6 weeks, 3, 6, and 12 months and annually thereafter. Plain radiographs were obtained annually. 58 patients who underwent Dynesys stabilisation with HA coated screws (312 screws) were evaluated. The data was compared with 71 patients who underwent Dynesys stabilisation with non-coated pedicle screws (366 screws). Outcome measures were screw loosening, breakage, implant removal or revision. Follow up was 96 %.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 217 - 223
1 Feb 2013
Hwang CJ Lee JH Baek H Chang B Lee C

We evaluated the efficacy of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (E-BMP-2) in a mini-pig model of spinal anterior interbody fusion. A total of 14 male mini-pigs underwent three-level anterior lumbar interbody fusion using polyether etherketone (PEEK) cages containing porous hydroxyapatite (HA). Four groups of cages were prepared: 1) control (n = 10 segments); 2) 50 μg E-BMP-2 (n = 9); 3) 200 μg E-BMP-2 (n = 10); and 4) 800 μg E-BMP-2 (n = 9). At eight weeks after surgery the mini-pigs were killed and the specimens were evaluated by gross inspection and manual palpation, radiological evaluation including plain radiographs and micro-CT scans, and histological analysis. Rates of fusion within PEEK cages and overall union rates were calculated, and bone formation outside vertebrae was evaluated. One animal died post-operatively and was excluded, and one section was lost and also excluded, leaving 38 sites for assessment. This rate of fusion within cages was 30.0% (three of ten) in the control group, 44.4% (four of nine) in the 50 μg E-BMP-2 group, 60.0% (six of ten) in the 200 μg E-BMP-2 group, and 77.8% (seven of nine) in the 800 μg E-BMP-2 group. Fusion rate was significantly increased by the addition of E-BMP-2 and with increasing E-BMP-2 dose (p = 0.046). In a mini-pig spinal anterior interbody fusion model using porous HA as a carrier, the implantation of E-BMP-2-loaded PEEK cages improved the fusion rate compared with PEEK cages alone, an effect that was significantly increased with increasing E-BMP-2 dosage. Cite this article: Bone Joint J 2013;95-B:217–23


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 116 - 116
1 Apr 2012
Pickard R Sharma A Reynolds J Nnadi C Lavy C Bowden G Wilson-MacDonald J Fairbank J
Full Access

A literature review of bone graft substitutes for spinal fusion was undertaken from peer reviewed journals to form a basis for guidelines on their clinical use. A PubMed search of peer reviewed journals between Jan 1960 and Dec 2009 for clinical trials of bone graft substitutes in spinal fusion was performed. Emphasis was placed on RCTs. Small and duplicated RCTs were excluded. If no RCTs were available the next best clinical evidence was assessed. Data were extracted for fusion rates and complications. Of 929 potential spinal fusion studies, 7 RCTs met the inclusion criteria for BMP-2, 3 for BMP-7, 2 for Tricalcium Phosphate and 1 for Tricalcium Phosphate/Hydroxyapatite (TCP/HA). No clinical RCTs were found for Demineralised Bone Matrix (DBM), Calcium Sulphate or Calcium Silicate. There is strong evidence that BMP-2 with TCP/HA achieves similar or higher spinal fusion rates than autograft alone. BMP-7 achieved similar results to autograft. 3 RCTs support the use of TCP or TCP/HA and autograft as a graft extender with similar results to autograft alone. The best clinical evidence to support the use of DBMs are case control studies. The osteoinductive potential of DBM appears to be very low however. There are no clinical studies to support the use of Calcium Silicate. The current literature supports the use of BMP-2 with HA/TCP as a graft substitute. TCP or HA/TCP with Autograft is supported as a graft extender. There is not enough clinical evidence to support other bone graft substitutes. This study did not require ethics approval and no financial support was received


Bone & Joint Research
Vol. 5, Issue 4 | Pages 145 - 152
1 Apr 2016
Bodalia PN Balaji V Kaila R Wilson L

Objectives

We performed a systematic review of the literature to determine the safety and efficacy of bone morphogenetic protein (BMP) compared with bone graft when used specifically for revision spinal fusion surgery secondary to pseudarthrosis.

Methods

The MEDLINE, EMBASE and Cochrane Library databases were searched using defined search terms. The primary outcome measure was spinal fusion, assessed as success or failure in accordance with radiograph, MRI or CT scan review at 24-month follow-up. The secondary outcome measure was time to fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 68 - 72
1 Jan 2011
Motosuneya T Maruyama T Yamada H Tsuzuki N Sakai H

We reviewed 75 patients (57 men and 18 women), who had undergone tension-band laminoplasty for cervical spondylotic myelopathy (42 patients) or compression myelopathy due to ossification of the posterior longitudinal ligament (33 patients) and had been followed for more than ten years. Clinical and functional results were estimated using the Japanese Orthopaedic Association score. The rate of recovery and the level of postoperative axial neck pain were also recorded. The pre- and post-operative alignment of the cervical spine (Ishihara curve index indicating lordosis of the cervical spine) and the range of movement (ROM) of the cervical spine were also measured.

The mean rate of recovery of the Japanese Orthopaedic Association score at final follow-up was 52.1% (sd 24.6) and significant axial pain was reported by 19 patients (25.3%). Axial pain was reported more frequently in patients with ossification of the posterior longitudinal ligament than in those with cervical spondylotic myelopathy (p = 0.027). A kyphotic deformity was not seen post-operatively in any patient. The mean ROM decreased post-operatively from 32.8° (sd 12.3) to 16.2° (sd 12.3) (p < 0.001). The mean ROM ratio was 46.9% (sd 28.1) for all the patients. The mean ROM ratio was lower in patients with ossification of the posterior longitudinal ligament than in those with cervical spondylotic myelopathy (p < 0.001). Compared to those with cervical spondylotic myelopathy, patients with ossification of the posterior longitudinal ligament had less ROM and more post-operative axial neck pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 785 - 789
1 Jun 2007
Ross R Mirza AH Norris HE Khatri M

Between January 1990 and December 2000 we carried out 226 SB Charité III disc replacements for lumbar disc degeneration in 160 patients. They were reviewed at a mean follow-up of 79 months (31 to 161) to determine the clinical and radiological outcome. The clinical results were collected by an independent observer, who was not involved in patient selection, treatment or follow-up, using a combination of outcome measures, including the Oswestry Disability Index. Pain was recorded using a visual analogue score, and the most recent radiographs were reviewed.

Survival of the device was analysed by the Kaplan-Meier method and showed a cumulative survival of 35% at 156 months when radiological failure was taken as the endpoint. The mean improvement in the Oswestry disability index scores after disc replacement was 14% (6% to 21%) and the mean improvement in the pain score was 1.6 (0.46 to 2.73), both falling below the clinically significant threshold. Removal of the implant was required in 12 patients, four because of implant failure.