Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 17 - 17
1 May 2018
Kontoghiorghe C Khaleel A
Full Access

Background

The circular Ilizarov frame is a well-established method of external fixation used in the acute treatment of fractures. In our unit, based on our experience, we have changed practice from an all-wire construct to a hybrid, incorporating one 5mm titanium half-pin in the distal reference construct. We were able to compare the all-wire construct against this hybrid in terms of time to union and complications.

Methods

All patients who underwent circular frame fixation between 2009 and 2016 for Schatzker IV-VI tibial plateau fractures at one district general hospital were included in the study. The date of union was noted and time to union was calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 563 - 563
1 Sep 2012
Petursson G Fenstad A Havelin L Gothesen O Röhrl S Furnes O
Full Access

Background. There are few studies of total knee replacements with cemented tibia and uncemented femur (hybrid). Previous studies have not shown any difference in revision rate between different fixation methods, but these studies had few hybrid prostheses. This study evaluates the results of hybrid knee replacements based on data from the Norwegian Arthroplasty Register (NAR). Patients and Methods. Primary total knee replacements without patella resurfacing, reported to the NAR during the years 1999–2009, were evaluated. Hinged-, posterior stabilized- and tumor prostheses were excluded. LCS- and Profix prostheses with conforming plus bearing were included. With the risk for revision at any cause as the primary end-point, 2945 hybrid knee replacements (HKR) were evaluated against 20838 cemented knee replacements (CKR). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex and preoperative diagnosis were used. Results. Kaplan-Meier estimated survival at 8 years was 94.0% (95% CI: 93.6–94.4) in the CKR group and 97.0% (95% CI: 96.0–98.0) in the HKR group. The HKR group was made op of three brands of prosthesis, LCS, LCS-complete and Profix. Profix was the only brand with a statistically significant difference between cemented and hybrid fixation. Kaplan-Meier estimated survival at 8 years was 97.7% (95% CI: 96.7–98.7) in hybrid Profix group (HPG) and 95.5% (95% CI: 94.7–96.3) in the cemented Profix group (CPG). The adjusted Cox regression analysis showed a statistically significantly lower risk for revision in the HPG group (relative risk=0.44, 95% CI: 0.39–0.59, p<0.001). Mean operating time was 15 minutes longer in the CKR group. Conclusion. Survivorship at 8 years of the hybrid primary total knee replacements was the same or superior compared to cemented total knee replacements depending on prosthesis brand Hybrid fixation seems to be a safe alternative to cemented fixation in total knee replacement surgery


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 217 - 224
1 Feb 2009
Rajasekaran S Dheenadhayalan J Babu JN Sundararajan SR Venkatramani H Sabapathy SR

Between June 1999 and May 2003 we undertook direct primary closure of the skin wounds of 173 patients with Gustilo and Anderson grade-IIIA and grade-IIIB open fractures. These patients were selected from a consecutive group of 557 with type-III injuries presenting during this time. Strict criteria for inclusion in the study included debridement within 12 hours of injury, no sewage or organic contamination, no skin loss either primarily or secondarily during debridement, a Ganga Hospital open injury skin score of 1 or 2 with a total score of ten or less, the presence of bleeding skin margins, the ability to approximate wound edges without tension and the absence of peripheral vascular disease. In addition, patients with polytrauma were excluded.

At a mean follow-up of 6.2 years (5 to 7), the outcome was excellent in 150 (86.7%), good in 11 (6.4%) and poor in 12 (6.9%). A total of 33 complications occurred in 23 patients including superficial infection in 11, deep infection in five and the requirement for a secondary skin flap in three. Six patients developed nonunion requiring further surgery, one of whom declined additional measures to treat an established infected nonunion.

Immediate skin closure when performed selectively with the above indications proved to be a safe procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 232 - 237
1 Feb 2006
Saridis A Panagiotopoulos E Tyllianakis M Matzaroglou C Vandoros N Lambiris E

We reviewed 13 patients with infected nonunion of the distal femur and bone loss, who had been treated by radical surgical debridement and the application of an Ilizarov external fixator. All had severely restricted movement of the knee and a mean of 3.1 previous operations. The mean length of the bony defect was 8.3 cm and no patient was able to bear weight.

The mean external fixation time was 309.8 days. According to Paley’s grading system, eight patients had an excellent clinical and radiological result and seven excellent and good functional results. Bony union, the ability to bear weight fully, and resolution of the infection were achieved in all the patients. The external fixation time was increased when the definitive treatment started six months or more after the initial trauma, the patient had been subjected to more than four previous operations and the initial operation had been open reduction and internal fixation.