Advertisement for orthosearch.org.uk
Results 1 - 20 of 523
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 11 - 11
1 Dec 2022
Upasani V Bomar J Fitzgerald R Schupper A Kelley S
Full Access

The Pavlik harness (PH) is commonly used to treat infantile dislocated hips. Variability exists in the duration of brace treatment after successful reduction of the dislocated hip. In this study we evaluate the effect of prescribed time in brace on acetabular index (AI) at two years of age using a prospective, international, multicenter database. We retrospectively studied prospectively enrolled infants with at least one dislocated hip that were initially treated with a PH and had a recorded AI at two-year follow-up. Subjects were treated at one of two institutions. Institution 1 used the PH until they observed normal radiographic acetabular development. Institution 2 followed a structured 12-week brace treatment protocol. Hip dislocation was defined as less than 30% femoral head coverage at rest on the pre-treatment ultrasound or IHDI grade III or IV on the pre-treatment radiograph. Fifty-three hips met our inclusion criteria. Hips from Institution 1 were treated with a brace 3x longer than hips from institution 2 (adjusted mean 8.9±1.3 months vs 2.6±0.2 months)(p < 0 .001). Institution 1 had an 88% success rate and institution 2 had an 85% success rate at achieving hip reduction (p=0.735). At 2-year follow-up, we observed no significant difference in AI between Institution 1 (adjusted mean 25.6±0.9˚) compared to Institution 2 (adjusted mean 23.5±0.8˚) (p=0.1). However, 19% of patients from Institution 1 and 44% of patients from Institution 2 were at or below the 50th percentile of previously published age- and sex- matched AI normal data (p=0.049). Also, 27% (7/26) of hips from Institution 1 had significant acetabular dysplasia, compared to a 22% (6/27) from Institution 2 (p=0.691). We found no correlation between age at initiation of bracing and AI at 2-year follow-up (p=0.071). Our findings suggest that prolonged brace treatment does not result in improved acetabular index at age two years. Hips treated at Institution 1 had the same AI at age two years as hips treated at Institution 2, while spending about 1/3 the amount of time in a brace. We recommend close follow-up for all children treated for dislocated hips, as ~1/4 of infants had acetabular index measurements at or above the 90th percentile of normal. Continued follow-up of this prospective cohort will be critical to determine how many children require acetabular procedures during childhood. The PH brace can successfully treat dislocated infant hips, however, prolonged brace treatment was not found to result in improved acetabular development at two-year follow-up


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 24 - 24
1 Apr 2013
Robertson CS Shardlow DL
Full Access

We Present the results of radiographic assessment of limb length and offset measurements of the first 50 Corin Mini Hips done at Yeovil District Hospital. All reconstructed Hips were compared with the contra lateral hip for leg length and offset restoration using the method of Murphy et al 2007. Excellent matching with the contralateral hip in terms of leg length and offset were found in 78% of hips and fair matching in 22%. The mean leg length discrepancy was 4 mm and mean offset discrepancy was 2 mm. Our results show that despite using a different paradigm to conventional hip replacements, this stem allows accurate restoration of hip geometry


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_6 | Pages 6 - 6
1 May 2015
Veettil M Ward A Smith E
Full Access

We report the medium term outcome of a 15 degrees face-changing acetabular cup in THA due to secondary OA in DDH. We analysed 28 Hips in 26 patients who underwent THA between May 2007and September 2009. There were 20 females and 6 males with a mean age of 52 yrs (range 33–68yrs). All patients received a cementless Exceed Advanced Bearing Technology 15° Face-changing cup (Biomet) with a ceramic liner through a posterior approach. A cementless or a cemented femoral stem, with 28 or 32mm Biolox Delta ceramic head, was used in all cases. All patients started full weight-bearing the next day. The average clinical and radiological follow-up was for 50 months (range 36–76 months). The mean Harris Hip Score improved to 94 and the Oxford Hip Score improved to 44. There was 100% survivorship of the hip joint for both components. Post-operative radiographs revealed integration of the cup with no signs of loosening or osteolysis. The mean covered acetabular lip inclination angle was 51 degrees (range 43–61)and the true inclination angle of the bearing was 36 degrees (range 28–46). The clinical results support the use of the cementless 15 degrees face-changing acetabular cup in the dysplastic acetabulum


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 59 - 59
1 Mar 2009
thambiraj S Vadivelu R Asirvatham R Hyde I Hogg C Abrams K
Full Access

Background and Aim: Developmental dysplasia of the hips covers a wide spectrum of hips scenario ranging from mild subluxation to frank dislocation. Sonographic examination has been a widely accepted method of screening and monitoring treatment. Graf IIa+ hips are believed to indicate physiological immaturity with alpha angles appropriate for age and are expected to develop normally without any treatment. The aim of this study was to assess the final outcome of sonographically proven Graf IIa+ hips and to identify any factors which may influence the progression of dysplasia in this group of children.

Materials and methods: Over a six year period, 19,170 new born babies were assessed for DDH. 393 infants with high risk factors and clinical abnormality of the hips underwent ultrasound examination. The scans were performed and reported according to Graf Technique. Pavlik harness treatment was instituted as indicated. Seventy four hips in 44 children were classified as Graf IIa+. Patients who had the hips scans before four weeks and those with incomplete medical records were excluded. All children had regular follow-up with a pelvic x-ray. Acetabular Index (AI), Reimers Index (RI) and Centre edge (CE) angle was measured. All children were followed up until their hips were clinically or radiologically satisfactory. The results were analysed using SPSS software.

Results: Thirty six children with 60 Graf IIa+ hips were eligible for this study. There were 28 girls with 46 hips and eight boys with 14 hips (Girls: Boys = 3.5:1). 29 Left hip and 31 right hip were involved. At a mean follow up of 13 months (range 6 – 41months), the AI was normal in 62%, mildly dysplastic in 30% and severly dysplastic in 8% of the hips. The Reimers Index was normal in 73%, sub-optimal in 24% and subluxated in 3% of the hips. The CE angle was normal in 65%, mildly pathological in 23% and moderately pathological in 12% of the hips. Limitation of abduction after 48hrs of birth appeared to have a direct effect on the development of dysplasia (p=0.02)

Conclusion: From our study, we believe that hips with Graf IIa+ scans are not as benign as they were thought to be. When associated with limited abduction after 48 hours of birth, a high index of suspicion and a long term follow up may be prudent.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 200 - 205
1 Feb 2022
Orita K Goto K Kuroda Y Kawai T Okuzu Y Matsuda S

Aims

The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA).

Methods

We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell’s Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 193 - 199
1 Feb 2022
Wang Q Wang H A G Xiao T Kang P

Aims

This study aimed to use intraoperative free electromyography to examine how the placement of a retractor at different positions along the anterior acetabular wall may affect the femoral nerve during total hip arthroplasty (THA) when undertaken using the direct anterior approach (THA-DAA).

Methods

Intraoperative free electromyography was performed during primary THA-DAA in 82 patients (94 hips). The highest position of the anterior acetabular wall was defined as the “12 o’clock” position (middle position) when the patient was in supine position. After exposure of the acetabulum, a retractor was sequentially placed at the ten, 11, 12, one, and two o’clock positions (right hip; from superior to inferior positions). Action potentials in the femoral nerve were monitored with each placement, and the incidence of positive reactions (defined as explosive, frequent, or continuous action potentials, indicating that the nerve was being compressed) were recorded as the primary outcome. Secondary outcomes included the incidence of positive reactions caused by removing the femoral head, and by placing a retractor during femoral exposure; and the incidence of femoral nerve palsy, as detected using manual testing of the strength of the quadriceps muscle.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 227 - 234
1 Feb 2022
Bettencourt JW Wyles CC Osmon DR Hanssen AD Berry DJ Abdel MP

Aims

Septic arthritis of the hip often leads to irreversible osteoarthritis (OA) and the requirement for total hip arthroplasty (THA). The aim of this study was to report the mid-term risk of any infection, periprosthetic joint infection (PJI), aseptic revision, and reoperation in patients with a past history of septic arthritis who underwent THA, compared with a control group of patients who underwent THA for OA.

Methods

We retrospectively identified 256 THAs in 244 patients following septic arthritis of the native hip, which were undertaken between 1969 and 2016 at a single institution. Each case was matched 1:1, based on age, sex, BMI, and year of surgery, to a primary THA performed for OA. The mean age and BMI were 58 years (35 to 84) and 31 kg/m2 (18 to 48), respectively, and 100 (39%) were female. The mean follow-up was 11 years (2 to 39).


Bone & Joint Open
Vol. 3, Issue 1 | Pages 61 - 67
18 Jan 2022
van Lingen CP Ettema HB Bosker BH Verheyen CCPM

Aims

Large-diameter metal-on-metal (MoM) total hip arthroplasty (THA) has demonstrated unexpected high failure rates and pseudotumour formation. The purpose of this prospective cohort study is to report ten-year results in order to establish revision rate, prevalence of pseudotumour formation, and relation with whole blood cobalt levels.

Methods

All patients were recalled according to the guidelines of the Dutch Orthopaedic Association. They underwent clinical and radiographical assessments (radiograph and CT scan) of the hip prosthesis and whole blood cobalt ion measurements. Overall, 94 patients (95 hips) fulfilled our requirements for a minimum ten-year follow-up.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 59 - 59
1 Mar 2009
Pillai A Bramley D
Full Access

Background: DDH represents a spectrum of anatomical abnormalities in which the femoral head and the acetabulum are either in improper alignment or grow abnormally. Although screening leads to earlier identification, 60–80% of abnormal hips of newborns identified by physical examination resolve spontaneously by 2–8 weeks and 90% of the hips of newborns with mild dysplasia identified by ultrasound resolve spontaneously between 6 weeks and 6 months. Aims: To assesses accuracy of ultrasound screening of neonatal hip by the static technique of Graf. We attempt to answer the question whether routine radiological follow up of these children are indicated. Methods: Since 2001, we have performed selective ultrasound screening of over 600 neonates (1200 hips). The reasons for referral included, breech presentation, clicky hip, unstable hip, dislocation, foot deformity and family history of DDH. Clinical examination, followed by serial ultrasound examinations at presentation, 6 weeks and 3 months of age were carried out. A radiological examination and measurement of the acetabular index was performed at 6 months of age. Hips were classified according to the 4 Graf types. We compared the ultrasound findings with the acetabular index (AI) for individual patients. Results: All children were followed up prospectively from presentation to discharge. For neonates without any family history of DDH and normal clinical examination (symmetrical skin creases, equal limb lengths, unrestricted abduction and no instability demonstrated on the Ortolani and Barlow manoeuvres) the ultrasound classification according to Graf co-related with the acetabular index on 6 month radiographs. 100% of hips with normal scan (Graf I) both at 6 weeks and at 3 months of age had a normal AI. Discussion: The static technique of Graf is an accurate and reliable method of assessment of neonatal hips. In children with normal clinical examination, and no family history of dysplasia, scan findings are a good predictor of the AI. Routine radiological follow up in such patients is not necessary


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 3 - 3
7 Jun 2023
Verhaegen J Devries Z Horton I Slullitel P Rakhra K Beaule P Grammatopoulos G
Full Access

Traditional radiographic criteria might underestimate or fail to detect subtle types of acetabular dysplasia. Acetabular sector angles (ASA) can measure the degree of anterior and posterior coverage of the femoral head on computed tomography (CT). This study aims to determine ASA values at different axial levels in a cohort of (1) asymptomatic, high-functioning hips without underlying hip pathology (controls); and (2) symptomatic, dysplastic hips that underwent periacetabular osteotomy (PAO). Thereby, we aimed to define CT-based thresholds for hip dysplasia and its subtypes.

This is an IRB approved cross-sectional study of 51 high functioning, asymptomatic patients (102 hips) (Oxford Hip Score >43), without signs of osteoarthritis (Tönnis grade≤1), who underwent a CT scan of the pelvis (mean age: 52.1±5.5 years; 52.9% females); and 66 patients (72 hips) with symptomatic hip dysplasia treated with peri-acetabular osteotomy (PAO) (mean age: 29.3±7.3 years; 85.9% females). Anterior and posterior acetabular sector angles (AASA & PASA) were measured by two observers at three CT axial levels to determine equatorial, intermediate, and proximal ASA. Inter- and intra-observer reliability coefficient was high (between 0.882–0.992). Cut-off values for acetabular deficiency were determined based on Receiver Operating Characteristic (ROC) curve analysis, area under the curve (AUC) was calculated.

The dysplastic group had significantly smaller ASAs compared to the Control Group, AUC was the highest at the proximal and intermediate PASA. Controls had a mean proximal PASA of 162°±17°, with a cut-off value for dysplasia of 137° (AUC: 0.908). At the intermediate level, the mean PASA of controls was 117°±11°, with a cut-off value of 107° (AUC 0.904). Cut-off for anterior dysplasia was 133° for proximal AASA (AUC 0.859) and 57° for equatorial AASA (AUC 0.868). Cut-off for posterior dysplasia was 102° for intermediate PASA (AUC 0.933).

Measurement of ASA on CT is a reliable tool to identify dysplastic hips with high diagnostic accuracy. Posterior ASA less than 137° at the proximal level, and 107° at the intermediate level should alert clinicians of the presence of dysplasia.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 73 - 73
19 Aug 2024
Ganz R Blümel S Stadelmann VA Leunig M
Full Access

The Bernese periacetabular osteotomy (PAO) is not indicated for growing hips as it crosses the triradiate cartilage in its posterior branch, and experimental work has shown this can induce substantial deformations, similar to posttraumatic dysplasia, which is observed after pelvis crash injuries in childhood.

Upon examination, all injuries in the 19 cases of posttraumatic dysplasia described in literature plus 16 hips of our personal collection took place before the age of 6, which is striking as pelvic injuries in children increase with age.

Based on this observation, we started to extend the PAO indication to severe dysplasias in children with open growth plate, initially aged 9 years and older. Following the positive results, it was extended further, our youngest patient being 5 years old.

We retrospectively examined radiographic outcomes of 23 hips (20 patients), aged 10.6±1.8 years [range 5.0 – 13.2], operated by us in four centers. Pre- and 3-months postoperative, and the latest FUP radiograph at growth plate closure were measured. We evaluated the acetabular index (AI), lateral center-edge (LCE), ACM-value and compared them with reference values adjusted for age. The age at triradiate cartilage closure was compared with the non-operated side.

The follow-up time was 5.4±3.7 years [0.8 - 12.7]. In 5 hips, growth plate closure was delayed by a few months. All angles significantly normalized after PAO (LCE: 14±8° → 38±11°, AI: 20±8° → 7±4°, ACM: 53±5° → 48±4°), with >80% of them severe pathological pre-PAO, none afterwards. Acetabular molding was normal. Only few complications occurred; one had signs of coxarthosis, one sciatic nerve pain, one interfering osteosynthesis material that was removed, one had an additional valgus osteotomy, and all resolved.

Based on 20 cases with follow-up until complete triradiate cartilage closure, we believe to have sufficient information to extend the PAO indication to growing hips of 9 years and older.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 17 - 17
19 Aug 2024
Treu EA Sato EH Omotowa OM Heaton TB Erickson JA Blackburn BE Anderson LA Peters CL
Full Access

Total hip arthroplasty (THA) is often performed in symptomatic patients with developmental dysplasia of the hip (DDH) who do not qualify for periacetabular osteotomy (PAO). The impact of osteoarthritis (OA) severity on postoperative outcomes in DDH patients who undergo THA is not well described. We hypothesized that DDH patients who undergo THA with mild OA have slower initial recovery postoperatively, but similar one-year patient reported outcome measures (PROMs) when compared to DDH patients with severe OA.

We performed a retrospective review at a single academic institution over a six-year period of patients with DDH who underwent primary THA and compared them to patients without DDH who underwent THA. Within the DDH cohort, we compared PROMs stratified by DDH severity and OA severity. Diagnosis of DDH was verified using radiographic lateral center edge angle (LCEA). Minimum one-year follow-up was required. PROMs were collected through one-year postoperatively. Logistic and linear regression models were used adjusting for age, sex, body mass index, and Charlson Comorbidity Index.

263 patients with DDH were compared to 1,225 THA patients without DDH. No significant differences were found in postoperative PROMs or revision rates (p=0.49). When stratified by DDH severity, patients with LCEA<10° had worse preoperative pain (p=0.01), mental health (p<0.01) and physical function (p=0.03) scores but no significant difference in postoperative PROMs. Within the DDH group, when stratified by OA severity, patients with Grade 3 Tonnis score had worse preoperative pain (p=0.04) but no significant difference in postoperative PROMs. Recovery curves in DDH patients based upon severity of DDH and OA were not significantly different at 2-weeks, 6-weeks and 1-year.

DDH patients who have mild OA have similar recovery curves compared to those with severe OA. THA is reasonable in symptomatic DDH patients who have mild arthritis and do not qualify for PAO.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 597 - 597
1 Oct 2010
Mavcic B Antolic V Iglic A Kralj-Iglic V Krizancic M Zupanc O
Full Access

Slipped capital femoral epiphysis is an important orthopaedic problem of early adolescence. Many hypotheses about its etiology have been proposed; still the underlying mechanisms are not clearly understood. The aim of our paper is to examine radiographic characteristics of hips at risk for slipped capital epiphysis. Two groups of hips were compared: a group of 100 asymptomatic hips contralateral to the slipped ones and a group of 70 age- and gender-matched healthy hips. The hips contralateral to the slipped ones were assumed to have identical morphology to the preslip-page morphology of the slipped hips. In each hip the following radiographic parameters were measured: the inter-hip distance, the femoral neck length/width, the pelvic height, the pelvic width, the femoral head radius, the coordinates of the abductor muscles trochanteric attachment, the inclination of the femoral epiphyseal growth plate, the femoral neck-shaft angle and the Wiberg center-edge angle. Subjects with hips at risk for slipping had significantly higher body weight (590 vs. 500 N; p < 0.001), larger diameter of the femoral neck (38.6 vs 37.3 mm; p = 0.027), higher (138.9 vs. 134.6 mm; p = 0.022) and wider pelvis (53.8 vs. 48.7 mm; p < 0.001) and more laterally placed abductor muscles trochanteric attachment. There were no significant differences in the inter-hip distance, the femoral head radius, the femoral neck length and the femoral neck-shaft angle angle. Hips contralateral to the slipped ones had a more vertically inclined physeal angle (55.4 vs. 63.2 degrees; p < 0.001) in comparison to the healthy hips. The Wiberg centre-edge angle of the hips contralateral to the slipped ones was on average 7% larger from the healthy group (34.7 vs. 32.2 degrees; p = 0.003). Children with hips at risk for slipping had larger pelvices and femora with more vertically inclined femoral epiphyseal growth plate. In addition, one cannot overlook the significant difference in the body weight between the age- and gender-matched groups of our study, confirming previous findings on the role of body weight in SCFE. It is therefore possible that anatomical changes may be a downstream effect of bone remodelling caused by altered loading during growth and development. This may suggest that the predisposition of the hip to slipping occurs earlier in the patient’s lifetime and that targeted radiographic examinations in obese individuals could reveal changes in pelvic geometry even before adolescence. Considering the high rates of bilateral involvement, our results could be used to predict the need for preventive fixation of asymptomatic hips after the capital femoral epiphysis has slipped in the contralateral hip


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 44 - 44
23 Jun 2023
Scholz J Perka C Hipfl C
Full Access

Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation.

We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103).

DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup retention (HR 8.23; p=0.022) were associated with re-dislocation. Radiological analysis did not reveal a relationship between restoration of hip geometry and re-dislocation. mHHS significantly improved from 43.8 points to 65.7 points (p<0.001) with no differences among bearing types.

Our findings suggest that DM bearings do not sufficiently prevent dislocation in revision THA for recurrent dislocation. Reconstruction of the abductor complex may play a key role to reduce the burden in these high-risk patients.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 314 - 314
1 May 2006
Jones DG Vane A Coulter G Herbison P Dunbar J
Full Access

The aim of this study was to determine the inter and intra observer reliability of ultrasound measurements in treated unstable neonatal hips and whether ultrasound measurements correlate with radiological outcome at 6 months. Sixty-four babies treated from birth with a Pavlik harness for neonatal hip instability were scanned at 2 and 6 weeks. The α and β angles of Graf, the combined (H) angle of Hosny and the femoral head coverage (FHC) were measured by 3 observers and inter-observer and intra-observer repeatability co-efficients calculated using 95% confidence limits. Hips were categorized as normal, abnormal or borderline for each parameter and Kappa values calculated. A stepwise linear regression analysis was performed to assess any relationship between ultrasound measurements at 2 or 6 weeks and outcome as determined by acetabular index at 6 months. Seven hundred and ninety two sets of measurements were made from 248 scans. The α angle had the smallest interobserver range (17°), the H angle range was 21°and the β angle 28°. Kappa values showed good agreement for FHC and β angle. The mean acetabular index of all hips at 6 months was 26° (sd 4.9). The acetabular index was 30° or greater in 24 hips (18 babies) despite prolonged splintage in 9 hips (6 babies). The FHC at 6 weeks was predictive of acetabular index at 6 months (regression coefficient −0.27, 95% CI −0.42 to −0.12, p< 0.001). We recommend the FHC as being reproducible, useful and predictive of outcome in neonatal hips treated for instability


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 29 - 29
23 Jun 2023
Briem T Stadelmann VA Rüdiger HA Leunig M
Full Access

Femoroacetabular impingement is a prearthritic deformity frequently associated with early chondral damage. Several techniques exist for restoring larger cartilage defects. While AMIC proved to be an effective treatment in knee and ankle, there are only short-term data available in hip. This study aimed to investigate the mid-term clinical outcome of patients with chondral lesions treated by AMIC and evaluate the quality of repair tissue via MRI.

This retrospective, single center study includes 18 patients undergoing surgical hip dislocation for FAI between 2013 and 2016. Inclusion criteria were: cam or pincer-type FAI, femoral or acetabular chondral lesions > 1 cm2, (IRCS III-IV). Due to exclusion criteria and loss-to-follow-up 9 patients (10 hips) could be included. Patient reported outcome measures included Oxford Hip Score (OHS) & Core Outcome Measure Index (COMI)). MRIs were evaluated using the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) score.

None of the patients underwent revision surgery except screw removals from the greater trochanter. Followup data indicate a satisfactory to good hip function at 5 years: PROMS improved from pre- to postop at 5 years: OHS from 38.1 to 43.4, COMI from to 1.8 and UCLA from 4 to 8.1 respectively. MOCART score was 67.5 postoperatively. Subgrouping showed slightly better results for acetabular defects (Ø 69.4) compared femoral defects (Ø 60).

Based on the reported mid-term results, we consider AMIC as a valuable treatment option for larger chondral defects of the hip.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 113 - 113
2 Jan 2024
García-Rey E Gómez-Barrena E
Full Access

Pelvic bone defect in patients with severe congenital dysplasia of the hip (CDH) lead to abnormalities in lumbar spine and lower limb alignment that can determine total hip arthroplasty (THA) patients' outcome. These variables may be different in uni- or bilateral CDH.

We compared the clinical outcome and the spinopelvic and lower limb radiological changes over time in patients undergoing THA due to uni- or bilateral CHD at a minimum follow-up of five years.

Sixty-four patients (77 hips) undergoing THA due to severe CDH between 2006 and 2015 were analyzed: Group 1 consisted of 51 patients with unilateral CDH, and group 2, 113 patients (26 hips) with bilateral CDH. There were 32 females in group 1 and 18 in group 2 (p=0.6). The mean age was 41.6 years in group 1 and 53.6 in group 2 (p<0.001). We compared the hip, spine and knee clinical outcomes. The radiological analysis included the postoperative hip reconstruction, and the evolution of the coronal and sagittal spinopelvic parameters assessing the pelvic obliquity (PO) and the sacro-femoro-pubic (SFP) angles, and the knee mechanical axis evaluating the tibio-femoral angle (TFA).

At latest follow-up, the mean Harris Hip Score was 88.6 in group 1 and 90.7 in group 2 (p=0.025). Postoperative leg length discrepancy of more than 5 mm was more frequent in group 1 (p=0.028). Postoperative lumbar back pain was reported in 23.4% of the cases and knee pain in 20.8%, however, there were no differences between groups. One supracondylar femoral osteotomy and one total knee arthroplasty were required. The radiological reconstruction of the hip was similar in both groups. The PO angle improved more in group 1 (p=0.01) from the preoperative to 6-weeks postoperative and was constant at 5 years. The SFP angle improved in both groups but there were no differences between groups (p=0.5). 30 patients in group 1 showed a TFA less than 10º and 17 in group 2 (p=0.7).

Although the clinical outcome was better in terms of hip function in patients with bilateral CDH than those with unilateral CDH, the improvement in low back and knee pain was similar. Patients with unilateral dysplasia showed a better correction of the PO after THA. All spinopelvic and knee alignment parameters were corrected and maintained over time in most cases five years after THA.


Securing the osteotomized greater trochanter (GT) during total hip arthroplasty (THA) for dislocated dysplastic hips (DDH) poses a significant challenge. This study evaluates the union rate and effectiveness of a 2-strand transverse wiring technique utilizing the lesser trochanter for wire anchorage and tensioning.

A digastric anterior slide trochanteric osteotomy was performed in 106 patients (118 hips) undergoing THA for DDH. Following uncemented stem insertion, the GT was transferred and fixed to the lateral cortex of the proximal femur using monofilament stainless steel wires. In 72 out of 106 patients (80 hips), the GT was fixed with 2 transverse wire cerclages threaded through 2 drill holes in the base of the lesser trochanter, spaced vertically 5–10 millimeters apart. The wires were wrapped transversely over the GT and tightened, avoiding contact with its tendinous attachments. Patients were regularly monitored, and GT union was assessed clinically and radiographically.

Patient ages ranged from 20 to 57 years (mean 35.5), with a follow-up period ranging from 1.5 to 12 years (mean 6.2). The mean union time was 3.3 months (range 2–7). Among all hips, two developed stable nonunion and single wire breakage, but no fragment displacement (2.5%). Two hips exhibited delayed union, eventually healing at 6 and 7 months after surgery.

Reattachment of the greater trochanter utilizing a 2-strand transverse wire cerclage anchored at the base of the lesser trochanter demonstrated a high rate of union (97.5%) following THA in dislocated DDH cases.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 38 - 38
23 Jun 2023
Karachalios T Varitimidis S Komnos G Koutalos A Malizos KN
Full Access

Local anatomical abnormalities vary in congenital hip disease patients. Authors often present early to mid-term total hip arthroplasty clinical outcomes using different techniques and implants randomly on patients with different types of the disease, making same conclusions difficult.

We report long term outcomes (13 to 23 years) of the treatment of low and high dislocation cases (separately) with total hip arthroplasty using TM technology acetabular cups (Implex initially and then Zimmer) and short fluted conical (Zimmer) femoral stems.

From 2000 to 2010, 418 congenital hip disease hip joints were treated in our department with total hip arthroplasty. According to Hartofilakidis et al's classification, 230 hips had dysplasia, 101 low dislocation, (group A) and 87 high dislocation (group B). Pre-operative and post-operative values, at regular intervals, of HHS, SF-12, WOMAC, OHS and HOOS were available for all patients. Patient, surgeon and implant related failures and complications were recorded for all patients.

In all cases an attempt was made to restore hip center of rotation. In group A the average lengthening was 2.8 cm (range: 1 to 4.2) and in group B 5.7 cm (range: 4.2 to 11). In both groups, no hips were revised due to aseptic loosening of either the acetabular cup or the femoral stem. In group A, a cumulative success rate of 95.6% (95% confidence interval, 92.7% – 97.4%) and in group B a cumulative success rate of 94.8% (95% confidence interval, 92.6%–96.9%) was recorded, at 20 years, with revision for any reason as an end point. No s.s. differences were found between groups when mean values of HHS, SF-12, WOMAC and OKS were compared.

Satisfactory long-term clinical outcomes can be achieved in treating different types of congenital hip disease when appropriate surgical techniques combined with “game changing” implants are used.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 42 - 42
1 Dec 2022
Fransen B Howard L MacDonell T Bengoa F Garbuz D Sheridan G Neufeld M
Full Access

Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the long-term survival and revision rates of HXLPE liners in primary THA, as well as the effect of liner thickness on these outcomes. We hypothesized that there would be no significant differences between the different liner thicknesses.

We performed a retrospective database analysis from a single center of all primary total hip replacements using HXLPE liners from 2010 and earlier, including all femoral head sizes. All procedures were performed by fellowship trained arthroplasty surgeons. Patient characteristics, implant details including liner thickness, death, and revisions (all causes) were recorded. Patients were grouped for analysis for each millimeter of PE thickness (e.g. 4.0-4.9mm, 5.0-5.9mm). Kaplan-Meier survival estimates were estimated with all-cause and aseptic revisions as the endpoints.

A total of 2354 patients (2584 hips) were included (mean age 64.3 years, min-max 19-96). Mean BMI was 29.0 and 47.6% was female. Mean follow-up was 13.2 years (range 11.0-18.8). Liner thickness varied from 4.9 to 12.7 mm. Seven patients had a liner thickness <5.0mm and 859 had a liner thickness of <6.0mm. Head sizes were 28mm (n=85, 3.3%), 32mm (n=1214, 47.0%), 36mm (n=1176, 45.5%), and 40mm (n=109, 4.2%), and 98.4% were metal heads. There were 101 revisions, and in 78 of these cases the liner was revised. Reason for revision was instability/dislocation (n=34), pseudotumor/aseptic lymphocyte-dominant vasculitis associated lesion (n=18), fracture (n=17), early loosening (n=11), infection (n=7), aseptic loosening (n=4), and other (n=10). When grouped by liner thickness, there were no significant differences between the groups when looking at all-cause revision (p=0.112) or aseptic revision (p=0.116).

In our cohort, there were no significant differences in all-cause or aseptic revisions between any of the liner thickness groups at long-term follow-up. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA does not lead to increased complications or liner failures at medium to long term follow-up. As such, orthopedic surgeons can consider the use of larger heads at the cost of liner thickness a safe practice to reduce the risk of dislocation after THA when using HXLPE liners.