Advertisement for orthosearch.org.uk
Results 1 - 20 of 28
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims

The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate.

Methods

A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1207 - 1213
1 Sep 2014
te Stroet MAJ Bronsema E Rijnen WHC Gardeniers JWM Schreurs BW

In this retrospective study, we investigated the results of revision total hip replacement (THR) using a cemented long-stemmed Exeter femoral component, with a minimum length of 205 mm in patients with extensive femoral bone defects. The study included 37 consecutive patients with a mean age of 76 years (39 to 93) and a mean follow-up of nine years (5 to 16). A total of 26 patients (70%) had a pre-operative Endo-Klinik score of 3 or 4. Impaction bone grafting was used in 24 patients (65%). At the time of evaluation, 22 patients (59%) were still alive and were evaluated clinically and radiologically. A total of 14 patients died during follow-up and their data were included until the time of their death. One reconstruction failed after five years and five months owing to recurrent dislocation: the hip was converted to an excision arthroplasty. Intra-operative fractures or fissures were encountered in nine patients (24%), but none occurred during impaction of the bone graft. Post-operative peri-prosthetic fractures occurred in two patients (5%); both were treated with plate fixation. At nine years, survival with the endpoint of all-cause re-revision was 96.3% (95% CI 76.4 to 99.5); including re-operations for any reason, it was 80.7% (95% CI 56.3 to 92.3%). There were no re-revisions for aseptic loosening.

The survival of long stem cemented femoral components following revision THR is satisfactory in a fragile population with extensive femoral defects.

Cite this article: Bone Joint J 2014; 96-B:1207–13.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 212 - 220
1 Feb 2022
Fishley WG Selvaratnam V Whitehouse SL Kassam AM Petheram TG

Aims. Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique. Methods. We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases. Results. Seven patients (7.9%) required further revision for infection. Ten patients died of causes unrelated to their infection before their two-year review (mean 5.9 months; 0.9 to 18.6). One patient was lost to follow-up at five months after surgery, and two patients died of causes unrelated to their hip shortly after their two-year review was due without attending. Of the remaining patients, 69 remained infection-free at final review. Radiological review confirms the mechanical success of the procedure as previously described in aseptic revision, and postoperative Oxford Hip Scores suggest satisfactory functional outcomes. Conclusion. In conclusion, we found that retaining a well-fixed femoral cement mantle in the presence of infection and undertaking a cement-in-cement revision was successful in 82 of the patients (92.1%) in our series of 89, both in terms of eradication of infection and component fixation. These results are comparable to other more invasive techniques and offer significant potential benefits to the patient. Cite this article: Bone Joint J 2022;104-B(2):212–220


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 29 - 29
1 Aug 2021
Fishley W Selvaratnam V Carluke I Partington P Reed M Kramer D Wilson M Hubble M Howell J Timperley A Whitehouse S Kassam A Petheram T
Full Access

Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision necessitate removal of all bone cement from the femur. In our two institutions, we have been using a cement-in-cement technique, leaving the distal femoral cement in selected cases for septic hip revision surgery. Between February 2010 and September 2019, 89 patients with prosthetic hip infection underwent first or single stage procedures leaving the distal femoral cement in situ and performing a cement-in-cement revision. The mean patient age was 72.0 years (24–92). The median time from the last arthroplasty procedure was 29.0 months (1–294). 81 patients underwent revision using a cemented Exeter stem, 7 patients received an articulating spacer, and one patient underwent excision arthroplasty with the distal cement left in situ. Patients received clinical and radiographic follow-up with a mean of 42.8 months (range 11.0–120.1 months). Oxford hip scores were collected from each institution's existing databases. 9 patients (10.1%) died within one year of surgery. No deaths were directly related to joint infection or the surgery. One patient was lost to follow up before one year. Of the remainder, 7 patients (8.9%) required further procedures for infection and were therefore considered to be treatment failures. 6 patients (7.6%) underwent planned second stage procedures with no recurrence of infection. 7 patients (8.9%) had further surgery for non-infective reasons. The Kaplan-Meier estimate of infection free survival at one year was 93.7% (95% CI 88.4 to 99.0%). No patients underwent revision for stem loosening. Oxford hip scores were available at over one year postoperatively for 51 patients with a mean score of 30.6, and a mean gain of 11.9. In our combined cohort of patients, cement-in-cement revision had an infection eradication rate of 91.1%. Patient selection is crucial, and the procedure can only be performed when there is a well-fixed cement mantle. However, when strict criteria are followed, this technique offers potential significant benefits to surgeons performing this challenging surgery, and more importantly the patients undergoing them


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 44 - 44
1 Nov 2021
Zhou Y
Full Access

With the approval of our institute, we reviewed all the robot-assisted hip revision during October 2019 and August 2021. MAKO joint arthroplasty system was used to perform the hip revision surgery. Seventy-one robot-assisted hip revision cases were included. Cup revisions were carried out in 68 patients while stem revisions were also carried out in 68 patients. Three types of registration techniques (extra acetabular bone surface based, liner based, metal shell based or cage surface based) on the acetabular side. The extra acetabular bone surface was the commonest used for registration (48/70, 68.6%, mean accuracy 0.37mm), followed by liner surface (11/70, 15.7%, mean accuracy 0.36mm), acetabulum cup (10/70, 14.3%, mean accuracy 0.37mm), and cage surface (1/70, 1.4%, accuracy 0.40mm). We succeeded cup registration and robotic arm guided cup insertion in all the cases. The average cup inclination and anteversion after revision were 40.87°±4.39° and 13.87°±4.24°, respectively. Cups in 62 cases (62/68, 91.2%) were within the Lewinnek safe zone while in 55 cases (55/68, 80.9%) were within the Callanan safe zone. The Mako robot-assisted system could bring favorable cup reconstruction in hip revision with acceptable surgical time and blood loss. Accurate registration could be achieved by different methods


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 33 - 33
1 Oct 2020
Bostrom MPG
Full Access

Introduction. Patients with aseptic loosening, a cause of failure in uncemented total joint arthroplasty (TJA), often present with fibrous tissue at the bone-implant interface. 1. In this study, we characterize the presence of neutrophil extracellular traps (NETs) in the intramedullary fibrotic membrane of aseptic loosening patients. We further explore the role of NETs, mediated by peptidyl arginine deiminase (PAD4), in peri-implant fibrosis and osseointegration failure through a murine model of unstable tibial implantation. 2–4. Methods. Peri-implant membrane was retrieved from five patients during total hip revision surgery and analyzed for the presence of NETs (citH3+ with extracellular DNA) via immunofluorescence. A Ti-6Al-4V implant was inserted in an oversized drill-hole in the right proximal tibia of 8-week-old C57BL/6J and PAD4 knockout mice (n=3 per group). Fourteen days later, all mice were euthanized, and implanted tibias were dissected. Fibrosis and osseointegration at the bone-implant interface were assessed by micro-computed tomography (microCT) and hematoxylin and eosin (H&E) staining. H&E samples were scored blindly by the investigator and another observer for signs of poor (score=0) to excellent osseointegration (score=3) using a rubric established in our lab. Results. NETs were found in peri-implant membrane collected from aseptic loosening patients (Figure 1a) and at the bone-implant interface in a murine model (Figure 1b). Unstable implants in wild type mice failed to osseointegrate, indicated by presence of fibroblast-like cells (dashed arrow), immature bone matrix (Figure 1c), low bone volume fraction (BV/TV) and bone surface area (BS) (Figure 1e). Unstable implants in PAD4. −/−. mice showed signs of good osseointegration such as mature trabeculae (solid arrow) (Figure 1d), higher BV/TV (p<0.10) and BS (p<0.05) (Figure 1f). Histological osseointegration scoring indicated wildtype mice exhibited an average score of 0.83 and PAD4. −/−. exhibited an average score of 2.5 (p<0.05, weighted Cohen's kappa = 0.714) (Figure 1g). Conclusion. NETs were characterized in fibrotic tissue in both aseptic loosening patients and in a murine model of unstable tibial implantation. NET inhibition was able to successfully prevent peri-implant fibrosis and osseointegration failure, leading the way for a potential novel non-invasive therapeutic approach for the treatment of aseptic loosening. For any figures, tables, or references, please contact the authors directly


Bone & Joint Open
Vol. 3, Issue 11 | Pages 867 - 876
10 Nov 2022
Winther SS Petersen M Yilmaz M Kaltoft NS Stürup J Winther NS

Aims

Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS).

Methods

Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims

To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time.

Methods

We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims

Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon.

Methods

A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1223 - 1230
1 Nov 2024
Dugdale EM Uvodich ME Pagnano MW Berry DJ Abdel MP Bedard NA

Aims

The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following total hip arthroplasty (THA). We sought to evaluate trends in BMI and complication rates of obese patients undergoing primary THA over the last 30 years.

Methods

Through our institutional total joint registry, we identified 15,455 primary THAs performed for osteoarthritis from 1990 to 2019. Patients were categorized according to the World Health Organization (WHO) obesity classification and groups were trended over time. Cox proportional hazards regression analysis controlling for confounders was used to investigate the association between year of surgery and two-year risk of any reoperation, any revision, dislocation, periprosthetic joint infection (PJI), venous thromboembolism (VTE), and periprosthetic fracture. Regression was stratified by three separate groups: non-obese; WHO Class I and Class II (BMI 30 to 39 kg/m2); and WHO Class III patients (BMI ≥ 40 kg/m2).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 27 - 27
1 Aug 2018
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E
Full Access

Leukocyte esterase (LE) has shown to be an accurate marker of prosthetic joint infections and has been proposed as an alternative to frozen section (FS) for intra-operative diagnosis. In this study, intra-operative determination of LE was compared with FS for the diagnosis of periprosthetic hip infections. One hundred and nineteen patients undergoing hip revision surgery due to prosthetic joint failure from June 2015 to December 2017 were considered. Joint fluids were collected before the arthrotomy for determination of LE which was performed by using enzymatic colorimetric strips. Four to six samples were stained with hematoxylin eosin for FS and considered suggestive for infection when at least 5 polymorphonuclear leukocytes in 5 fields at high power fields were found. Sensitivity and specificity of LE were 100% and 93.8 %, respectively. The positive predictive value was 79.3 %, while the negative predictive value was 100%. Time from collection to response was 20.1 ± 4.4 minutes. Sensitivity and specificity of FS were 83.3 % and 92.1 %, respectively. The positive and negative predictive values were 84.6 % and 97.1%. Time from sample collection response was 27.2 ± 6.9 minutes. LE showed a higher sensitivity and a slightly lower specificity and the same diagnostic accuracy of intraoperative FS. The faster turnaround time (about 20 minutes from receiving of sample by the laboratory), its ease of use and the low costs make this test a valuable alternative to frozen sections and is going to replace FS in our clinical practice


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 820 - 825
1 Jul 2022
Dhawan R Baré JV Shimmin A

Aims

Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA.

Methods

A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 69 - 69
1 Oct 2018
Muratoglu OK Chaudhary M Varadarajan KM
Full Access

Introduction. Ceramic heads are used in hip revision surgery to mitigate corrosion concerns. Manufacturers recommend using a pristine titanium sleeve in conjunction with a well-fixed metal stem to prevent early failure of the ceramic head. However, the influence of impact force, head size, and sleeve offset on pull-off strength and seating displacement of a revision head assembly is not fully understood. Therefore, the purpose of this study was to investigate the pull-off strength and displacement of commercially available revision ceramic heads and titanium taper sleeve offsets (BIOLOX OPTION, CeramTec GmbH, Plochingen, Germany) while covering a range of clinically relevant impaction forces. Methods. Two head sizes (28 mm, n = 12 and 36 mm, n = 12) and two taper adapter sleeve offsets (small, n = 12 and extra-large, n = 12) were tested in this study. A dynamic impaction rig was constructed to seat the head, sleeve, and stem assembly (Fig. 1). Consistent impaction forces were achieved by dropping a hammer fixed to a lever arm from a pre-determined height onto a standard impactor instrumented with a piezoelectric force sensor (PCB Piezotronics Inc.). Axially applied forces of 2 kN and 6 kN were used to cover a range of typical impaction forces. Three non-contact differential variable reluctance transducers (LORD Sensing Systems) were used to track the displacement of the head relative to the stem. Subsequently, samples were transferred to a servo hydraulic testing machine, and a pull-off test was carried out per ISO 7206–10 to measure the disassembly force. Results. For all head and sleeve combinations assembled at 6 kN, pull-off forces and assembly displacements were over two times the values measured at 2 kN. As expected, an increased assembly force resulted in increased pull-offs and displacements. Head size did not play a significant role on measured outcomes. Regarding sleeve offsets, at assembly of 6 kN mean pull-off forces for extra-large sleeves were reduced by approximately 25% relative to small sleeves (Fig 2). However, at a 2 kN assembly, sleeve offsets did not appear to influence pull-off forces. Discussion. This study assessed the effect of impact assembly force, head size, and sleeve offset on pull-off strength and seating displacement of revision ceramic heads. The data suggests assembly force and sleeve offset may influence the pull-off strength and seating displacement of modular heads used in revision hip arthroplasty. Mean pull-off forces for revision heads were comparable in magnitude and trend to previous studies assessing the linear relationship between assembly force and pull-off force in primary heads (Krull et al., 2017, Rehmer et al., 2012). Lower pull-off forces were observed for extra-large sleeves when compared to small sleeves, indicating, decreased contact at the sleeve and stem interface for extra-large offsets may play a role in reducing pull-off forces. Acknowledgment:. The authors would like to thank CeramTec GmbH (Plochingen, Germany) for providing the head, sleeve, and stem implants. For any figures or tables, please contact authors directly


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 492 - 499
1 Mar 2021
Garcia-Rey E Saldaña L Garcia-Cimbrelo E

Aims

Bone stock restoration of acetabular bone defects using impaction bone grafting (IBG) in total hip arthroplasty may facilitate future re-revision in the event of failure of the reconstruction. We hypothesized that the acetabular bone defect during re-revision surgery after IBG was smaller than during the previous revision surgery. The clinical and radiological results of re-revisions with repeated use of IBG were also analyzed.

Methods

In a series of 382 acetabular revisions using IBG and a cemented component, 45 hips (45 patients) that had failed due to aseptic loosening were re-revised between 1992 and 2016. Acetabular bone defects graded according to Paprosky during the first and the re-revision surgery were compared. Clinical and radiological findings were analyzed over time. Survival analysis was performed using a competing risk analysis.


Bone & Joint Research
Vol. 1, Issue 10 | Pages 258 - 262
1 Oct 2012
Keurentjes JC Fiocco M Schreurs BW Pijls BG Nouta KA Nelissen RGHH

Objectives. The Kaplan-Meier estimation is widely used in orthopedics to calculate the probability of revision surgery. Using data from a long-term follow-up study, we aimed to assess the amount of bias introduced by the Kaplan-Meier estimator in a competing risk setting. Methods. We describe both the Kaplan-Meier estimator and the competing risk model, and explain why the competing risk model is a more appropriate approach to estimate the probability of revision surgery when patients die in a hip revision surgery cohort. In our study, a total of 62 acetabular revisions were performed. After a mean of 25 years, no patients were lost to follow-up, 13 patients had undergone revision surgery and 33 patients died of causes unrelated to their hip. Results. The Kaplan-Meier estimator overestimates the probability of revision surgery in our example by 3%, 11%, 28%, 32% and 60% at five, ten, 15, 20 and 25 years, respectively. As the cumulative incidence of the competing event increases over time, as does the amount of bias. Conclusions. Ignoring competing risks leads to biased estimations of the probability of revision surgery. In order to guide choosing the appropriate statistical analysis in future clinical studies, we propose a flowchart


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1319 - 1323
3 Oct 2020
Khatun F Gill DF Atrey A Porteous M

Aims

We present the results, in terms of survival, clinical outcome, and radiological appearance at 20 years, in a cohort of 225 cemented Exeter Universal femoral components (Stryker, Newbury, UK) implanted in 207 patients, at a district general hospital.

Methods

All patients in this study had a total hip arthroplasty (THA) using an Exeter Universal femoral component with a cemented (n = 215) or cementless (n = 10) acetabular component. Clinical and radiological data were collected prospectively at one year, five years, and every five years thereafter. Patients lost to radiological and clinical follow-up (five) were cross-referenced with National Joint Registry (NJR) data and general practitioner (GP) records to assess whether they had undergone revision for any reason.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 901 - 909
1 Jul 2016
Amstutz HC Le Duff MJ

Aims. Hip resurfacing arthroplasty (HRA) is an alternative to conventional total hip arthroplasty for patients with osteonecrosis (ON) of the femoral head. Our aim was to report the long-term outcome of HRA, which is not currently known. Patients and Methods. Long-term survivorship, clinical scores and radiographic results for 82 patients (99 hips) treated with HRA for ON over a period of 18 years were reviewed retrospectively. The mean age of the 67 men and 15 women at the time of surgery was 40.8 years (14 to 64). Patients were resurfaced regardless of the size of the osteonecrotic lesion. Results. The mean clinical follow-up was 10.8 years (2 to 18). The mean University of California, Los Angeles hip scores at the last follow-up were 9.3, 9.4, 9.2 and 6.8 for pain, walking, function and activity, respectively. A total of six hips underwent revision surgery, four for loosening of the femoral component and two for loosening of the acetabular component. Using any revision as an end point, the 15-year Kaplan-Meier survivorship was 90.3%. There were no wear-related failures. There were no femoral failures among the hips reconstructed with a cemented metaphyseal stem. A total of five hips showed narrowing of the femoral neck; all stabilised and remain asymptomatic, 21 showed signs of femoral neck impingement. Conclusion. To our knowledge, this is the first report of a series of HRA performed for ON with 15-year survivorship. Our data confirm that patients with advanced stages of ON of the femoral head are excellent candidates for HRA. Cite this article: Bone Joint J 2016;98-B:901–9


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1278 - 1283
1 Oct 2008
Eswaramoorthy V Moonot P Kalairajah Y Biant LC Field RE

We report the clinical and radiological outcome at ten years of 104 primary total hip replacements (100 patients) using the Metasul metal-on-metal bearing. Of these, 52 had a cemented Stuehmer-Weber polyethylene acetabular component with a Metasul bearing and 52 had an uncemented Allofit acetabular component with a Metasul liner. A total of 15 patients (16 hips) died before their follow-up at ten years and three were lost to follow-up. The study group therefore comprised 82 patients (85 hips). The mean Oxford score at ten years was 20.7 (12 to 42). Six of 85 hips required revision surgery. One was performed because of infection, one for aseptic loosening of the acetabular component and four because of unexplained pain. Histological examination showed an aseptic lymphocytic vasculitis associated lesion-type tissue response in two of these. Continued follow-up is advocated in order to monitor the long-term performance of the Metasul bearing and tissue responses to metal debris


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 190 - 194
1 Mar 2004
Bizot P Hannouche D Nizard R Witvoet J Sedel L

Between 1990 and 1992, we implanted 71 hybrid alumina-on-alumina hip arthroplasties in 62 consecutive patients under the age of 55 years, with a mean age of 46 years at surgery. There were 56 primary and 15 secondary procedures. The prostheses involved a cemented titanium alloy stem, a 32 mm alumina head, and a press-fit metal-backed socket with an alumina insert. Three patients (four hips) died from unrelated causes. Four hips had revision surgery for either deep infection, unexplained persistent pain, fracture of the alumina head, or aseptic loosening of the socket. The nine-year survival rate was 93.7% with revision for any cause as the end-point and 98.4% with revision for aseptic loosening as the end-point. The outcome in the surviving patients (50 patients, 57 hips) with a minimum five-year follow-up (mean eight years) was excellent in 47 hips (82.5%), very good in eight (14%), good in one and fair in one. A thin, partial, lucent line, mainly in zone III was present in 38% of the sockets and one socket had a complete lucency less than 1 mm thick. One stem had isolated femoral osteolysis. There was no detectable component migration nor acetabular osteolysis. This hybrid arthroplasty gave satisfactory medium-term results in active patients. The press-fit metal-backed socket appeared to have reliable fixation in alumina-on-alumina hip arthroplasty. The excellent results using cemented fixation of the stem may be related to the low production of wear debris


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 380 - 388
1 Apr 2003
Tidermark J Ponzer S Svensson O Söderqvist A Törnkvist H

The treatment algorithms for displaced fractures of the femoral neck need to be improved if we are to reduce the need for secondary surgery. We have studied 102 patients of mean age 80 years, with an acute displaced fracture of the femoral neck. They were randomly placed into two groups, treated either by internal fixation (IF) with two cannulated screws or total hip replacement (THR). None showed severe cognitive dysfunction, all were able to walk independently, and all lived in their own home. They were reviewed at four, 12 and 24 months after surgery. Outcome measurements included hip complications, revision surgery, hip function according to Charnley and the health-related quality of life (HRQoL) according to EuroQol (EQ-5D). The failure rate after 24 months was higher in the IF group than in the THR group with regard to hip complications (36% and 4%, respectively; p < 0.001), and the number of revision procedures (42% and 4%, p < 0.001). Hip function was significantly better in the THR group at all follow-up reviews regarding pain (p < 0.005), movement (p < 0.05 except at 4 months) and walking (p < 0.05). The reduction in HRQoL (EQ-5D . index. score) was also significantly lower in the THR group than in the IF group, comparing the pre-fracture situation with that at all follow-up reviews (p < 0.05). The results of our study strongly suggest that THR provides a better outcome than IF for elderly, relatively healthy, lucid patients with a displaced fracture of the femoral neck